Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 1ST FLOOR HAQUE MARKET BV COLLAGE RAJA BAZAR BAILLY ROAD PATNA BIHAR 800014 | PATNA | BIHAR | 800014 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.0 L
EMD Value
₹3,964
Closing Date
13 Sept 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HOD(IWD)
IWD, IIT Patna
Electrical works to provide power to several machine in the department of MME at IIT Patna
2023_IITP_765798_1
IITP/IWD/Elect./A/NIT-01/23-24
Open Tender
Electrical Works
Works
15 days
IIT Patna
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹3,964
Yes
14 Sept 2023
8 Aug 2023
14 Sept 2023
8 Aug 2023
13 Sept 2023
8 Aug 2023
8 Aug 2023 - 7 Sept 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C) Polycab/RR Kabel/KEI
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. Polycab/RR Kabel/KEI
Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.Polycab/RR Kabel/KEI
Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 10 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.Polycab/RR Kabel/KEI
Wiring for circuit/ submain wiring alongwith earth wire with the 4 X 6 sq. mm + 2 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.Polycab/RR Kabel/KEI
Providing and fixing 100 A,36KA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Legrand/ABB/L&T
Providing and fixing 200 A,36KA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Legrand/ABB/L&T
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Legrand/ABB/L&T
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of four poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Legrand/ABB/L&T
Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of triple poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Legrand/ABB/L&T
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).Lrgrand Mylink/Equivalent
Supplying and fixing metal sheet enclosure suitable for four pole including connection etc. as required.Legrand/ABB/L&T
Supplying and fixing suitable size PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 70 sq. mm (38 mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
SONA ENTERPRISES
jayaa enterprises
AARYA ELECTRICAL ENGINEERING WORKS
M/S POWER SYSTEM SERVICE
GRAND MARKETING CO.
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .