Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹14.2 L+₹1.2 L (9.19%)Rejected-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹14.5 L+₹1.5 L (11.5%)Rejected-Finance 9TH FLOOR ABHIJEET MITHAKALI SIX ROADS MITHAKALI AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹15.9 L+₹3.0 L (22.9%)Rejected-Finance | L4 | Rejected-Finance that the bid is not L1 | |
| 5 | Rejected-Technical SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | - | Rejected-Technical due to insufficient amount of credential |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
29 Oct 2019, 11:30 amClosed
EE NKHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of AIR conditioning system and allied EI works at ENT Department at RG Kar Medical Colleage Hospital Part A SITC of Airconditioning System
2019_PWDE_245924_1
WBPWD/EE/NKHED/NIQ-52/19-20
Open Tender
A/C ORG
Item Rate
90 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹26,000
17 Mar 2020
23 Sept 2019
31 Oct 2019
25 Sept 2019
29 Oct 2019
25 Sept 2019
Amount
SITC of 1.5 TR capacity Concealled Split type Air Conditioner of rated cooling capacity of 18000 BTU/hr. with 1No. Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 650CFM. ( Make: Hitachi/Mitsubishi/O-General) The OD Unit on prelaid fabricated structure Alloca tion :- Cabin-1,Cabin-2, 2 nd Fllor OT Complex Utility Rooom , Bone disection Room Area of Flowing Rooms Inbetween 125 Sq. Ft- 150 sq. Ft)
SITC of 2 TR capacity Concealled Split type Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1No. Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz. Air-flow/per IDU:- 900 CFM. ( Make: Hitachi/Mitsubishi/O-General) Allocation:-Room No-61 ,62,63,53,52 Ward Office , Minor OT,Asst. Professor Room /Doctors Room =3 Nos Room Area of Flowing Rooms Inbetween (180 Sq. Ft- 210 sq. Ft)., Clinic Room(2x2TR) ,
Copper Refrigeration pipe line for Liquid Line, Suction Line (1/4" OD with 0.6 mm thick) supports & brackets for Concealed Split AC Machine
Copper Refrigeration pipe line for Suction Line (5/8" OD with 0.7mm thick)) supports & brackets for Concealed Split AC Machine
Supply & Fixing Pipe Insulation in suction line (5/8")with 9mm nitrile rubber tube for Concealed Split AC Machine
Supply & Fixing Pipe Insulation in Liquid line (1/4")with 9mm nitrile rubber tubefor Concealed Split AC Machine
Control Cabling from Condensing Unit to Control Panel 4 Core 2.5sq. mm. Communication Cable for Concealed Split AC Machine
Supply & laying PVC Drain Pipe 25mm dia
FRAME BASE :-Supplying, fabrication & fixing 2 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) of( 1.2m widh x Lenghth )for making Base Frame for installation of outdoor unit of4.0 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with 2 Nos. horizontal angle of 50 mm x 50 mm x 6 mm of 1.2m length. of several no individual units of structure at different location which rest two or more Outdoor units at a time . with 2 coat RO Primer & Paints
Additional Support :- The additional support with MS angel of size 50x50x6 mm from the bottom average lenth is 5' of arm support ,at least three for each Base struture . with 2 coat RO Primer & Paints SIDE RALING :-Side railing to be done eith 20x20x5 mm MS angel iron along with 3 side of above MS iron structure at the hight of 2' & 4' .with inter midiate vertical support at an average gap of 3.5' . with 2 coat RO Primer & Paints
ACP Boxing & Trapdoor Arrangemernt :- i) Supply & Errction of aluminium composit panels (ACP). Interior grade of thickness 3.00 mm comprising of protective flim, polyester coating. Finally service as per manufacture specification finished withaluminium screw and silicon sealent complete in all respect including all incidental charges etc. as per direction . The colour is Off White colour ACP Combination as per direction of EIC.( Make-Aludecor or as directed by EIC) ii) Frame & Structure :- The structure should be made of 1.5"x1", 16 SWG aluminium Angel . The grid (2'x2') of aluminium preperation in such way that it rest the ACP ducting .
Supply & Return Grill :- Supply & fixing of Aluminium Mouth grill . Make-dynacraft or as directed by EIC
Special Terms & Conditions :- i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / Support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. ii) Documents that authenticates such procurement form the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM /authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. iii) If any refurbished material is supplied and installed, panel action will be taken as per existing rules.
Rate should be quoated including all taxes and duties
SKY DECORATIONS PRIVATE LIMITED
JOHNSON CONTROLS HITACHI AIR CONDITIONING INDIA LTD.
EVAC ENGINEERING PROJECTS PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .