Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.5 L+₹62,709 (3.52%)Rejected-Finance 24 A RAGHBIR MARG NEAR 22 NO PHATAK PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.3 L+₹3.5 L (19.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
9 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Patiala
Sh Anup Gupta SE IDSE CWE HQ CWE Patiala Building No 26 New Lal Bagh Patiala PIN 147001
REPAIR MAINTENANCE AND COMPLAINTS OF HV LV ELECTRICAL SYSTEEM AT PATIALA MIL STN UNDER GE NORTH PATIALA
2021_MES_487123_1
CWE/PAT/68/2021-22
Open Tender
Civil Works
Item Rate
180 days
Patiala Mil Station under GE North Patiala
As per NIT
7 documents required · 7 mandatory
₹500
Yes
₹50,000
Yes
12 Jan 2022
9 Nov 2021
11 Dec 2021
9 Nov 2021
9 Dec 2021
3 Dec 2021
9 Nov 2021 - 25 Nov 2021
60 days
Amount
Schedule 'A' (External Electrification Works)
providing labour transport and T&P for locating the fault in Ht/LT line in OH/UG Line/cable by visual inspection recce of faulthy area and repairs to the fault by means of replacement of Unservicible Jumpers /Fuse wires /Burnt lugs /MCCB etc. inclusive of ,restraing of broken ACCR counductures /Earth wire for taking cable and relay the same after defects neat upto 5 M length . Note : Materials requried for fault repairs will be measured under relevant items included in BOQ.
Replacement of HT fuse wire of all size , Fuse wires will be provided on requirement basis under relevent sch of BOQ all as directed and specified by Engr in Charge.
Supply only the HT fuse wire of size 5 Amps of capacity.
Supply only the HT fuse wire of size 10 Amps of capacity.
Supply only the HT fuse wire of size 20 Amps of capacity.
Supply only the HT fuse wire of size 32 Amps of capacity.
Supply only the HT fuse wire of size 40 Amps of capacity.
Supply only the HT fuse wire of size 63 Amps of capacity.
Supply only the HT fuse wire of size 100 Amps of capacity.
Replacement of HT Pin/Disc insulator all as directed and specified by Engr in Charge
Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed
Supply only Disc type porcelain insulator, vitreous 145mm height and 255 dia ball and socket type, white, brown and green " Two in series" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade complete all as specified and directed
Replacement of HT Jumper all as directed and specified by Engr in Charge Note : Materials requried for fault repairs will be measured under relevant items included in BOQ.
Supply only multi-jointed ACSR jumpers of HT over head lines with and incl XLPE/PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed .(Length of one jumper not exceeding more than 3.0 mtrs .
All as per item No15.00. above but of size 240 Sqmm.
Laying only HT/LT cable for providing temporory supply to feeder of various sizes from MES store and deposited back to store yard after permanent rectification of fault. All as directed and specified by Engr in Charge(Cost inclusive of transport of cables from stores to fault sites ,fixing arrangement /dismantling of old cables/refixing of new cables as required at site )
Supply and Fix cable lugs aluminium any type suitable for cable up to 10 sqmm including necessary crimping with crimping tool complete all as specified and directed .
.-ditto-all as per item 18.00 but of size up to 16 sqmm
.-ditto-all as per item 18.00 but of size up to 25 sqmm -
.-ditto-all as per item 18.00 but of size up to 35 sqmm
.-ditto-all as per item 18.00 but of size up to 50 sqmm
.-ditto-all as per item 18.00 but of size up to 70 sqmm
.-ditto-all as per item 18.00 but of size up to 95 sqmm
.-ditto-all as per item 18.00 but of size up to 120 sqmm
.-ditto-all as per item 18.00 but of size up to 150 sqmm
.-ditto-all as per item 18.00 but of size up to 185 sqmm
.-ditto-all as per item 18.00 but of size up to 240 sqmm
.-ditto-all as per item 18.00 but of size up to 300 sqmm
.-ditto-all as per item 18.00 but of size up to 400 sqmm
Repair/replacement of LT Jumper all as directed and specified by Engr in Charge
Connecting /disconnecting of air-conditioner in married officers quarters, OTM, offrs Mess from the existing over head lines all as directed and specified by Engr in Charge.(Cables and materials for connection will be provided by occupant /user of the accn)
Fixing only of wornout/damaged MCCB of any rating as directed and specified by Engr in Charge. MCCB will be provide by the contractor or from MES store for fixing and replacement.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 25 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 3 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
Supply only MCCB with adjustable thermal and magentic setting type Release Range 630 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed. Special Notes:- (a) Contractor will provide all T & P, communication device (Mobile Phone) to deployed persons to all deployed electrcian team for each sub station required for repair of HT/LT Electrical switch gear including safety equipment such as All type of T&Ps (Bamboo ladders, screw drivers, wire/cable cutters with blades, multi meters, cutting plairs, tourch lights etc) for routine maintenance and protection of the trademan incl safety equipment such as Hand gloves, Rubber boots, Sefety belt and helmets etc. (b) On intimation of any type of repair/maintenance work of HT/LT switch gear incomer as well as out going feeder the contractor is responsible to locate the fault by the dedicated team comprising tradesman helpers required numbers as per the gravity /nature of the work involved to restore the power supply and communicate with SBA on duty and getting permit card for working on HT lines and deposit the permit card after rectification of fault, all the activities shall be carried out with in reasonable time as given by the Engineer-in-Charge. (c) Contractor will provide necessary complaint slip, complaint boook & permit book, contractor will direct the instructions to indls for lodgging the complaints duly marked the location, time and date for earlier rectifications. (d) After getting the complaints, team deployed by the contractor will rectify the complaints within stipulated time i.e within 2 hours from the time of receiving of complaints. (e) Contractor shhould also provide a dedicated supervisor for collection of complaints from SBA, JE, USER etc. He would be held responsible in case complaints are not collected timely
MAHESH KUMAR SINGLA CONTRACTOR
AR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .