Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹8.7 Cr | L1 | Accepted-AOC Being Lowest Tender |
| 2 | L2₹8.8 Cr+₹8.9 L (1.02%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹8.8 Cr+₹8.9 L (1.02%) | L2 | Rejected-Finance Higher than Lowest Tender |
| 3 | L3₹8.9 Cr+₹20.9 L (2.40%)Rejected-Finance | ₹8.9 Cr+₹20.9 L (2.40%) | L3 | Rejected-Finance Higher than Lowest Tender |
| 4 | L4₹10.1 Cr+₹1.4 Cr (16.2%)Rejected-Finance | ₹10.1 Cr+₹1.4 Cr (16.2%) | L4 | Rejected-Finance Higher than Lowest Tender |
Tender Value
Refer Docs
EMD Value
₹8.6 L
Closing Date
22 Feb 2021, 6:00 pmClosed
CE KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
ADDN ALTN AND SPL REPAIRS TO CERTAIN JCOs AND ORs MD ACCN AT KOLKATA
2020_MES_396957_1
89029/E8
Open Tender
Civil Works
Item Rate
700 days
KOLKATA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE CENTRAL KOLKATA
₹8.6 L
Yes
5 Mar 2021
20 Nov 2020
24 Feb 2021
20 Nov 2020
22 Feb 2021
8 Feb 2021
Amount
SCHEDULE 'A' PART I (B/R WORKS)
Chipping of unsound /weak concrete materials from slabs , beams, columns ,lintel,chajja, fin , facia etc. by any means including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed by Engr-in-Charge. for 25mm average thickness for slabs/Chajja/beams (upto 04 storied of building).
ditto all as per item No. 1.01 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.01 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
ditto all as per item No. 1.01 here-in-before but for 50mm average thickness for beam/lintel (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.04 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.04 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
ditto all as per item No. 1.01 here-in-before but for 60mm average thickness for column (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.07 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Add or deduct for every 10 mm thickness extra (upto 4 storey of building) complete all as specified and as directed.
ditto all as per item No. 1.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.10 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical as per manufacturer's instruction followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed. upto 12 mm dia bar (upto 4 storey of building)
ditto all as per item No. 1.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.13 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge above 12 mm dia bar (upto 4 storey of building)
ditto all as per item No. 1.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.16 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material and labour for providing single coat epoxy bond adhesive on prepared non metallic surface (existing surface) and applying by brush as per manufactureres instruction/ specifications. The bonding agents shall have minimum compressive strength of 40N/mm² upto 4 storiey of building complete all as specified and as directed.
ditto all as per item No. 1.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.19 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimum specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. (upto 4 storey of building)
ditto all as per item No. 1.22 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.22 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for introducing new reinforcement bars upto 12mm dia bars Fe 550CRS for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges or welding to existing reinforcement steel etc all as specified and directed. (upto 4 storey of building)
ditto all as per item No. 1.25 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.25 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges or welding to existing reinforcement steel etc all as specified and directed. Above 12 mm dia bar Fe 550 CRS (upto 4 storey of building)
ditto all as per item No. 1.28 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.28 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed by Engr-in-charge for 60 mm average thickness of Column (upto 4 storey of building).
ditto all as per item No. 1.31 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.31 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as spd and dir by Engr-in-charge. 50 mm average thickness of Beam/Column (upto 4 storey of building)
ditto all as per item No. 1.34 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.34 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and as directed. Add or deduct for every 10 mm thickness extra (upto 4 storey of building)
ditto all as per item No. 1.37 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.37 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply, mixing and laying of shrinkage controlled, polymer modified, fiber rainforced cementitious moarter as per manufacturer's instruction after application of bonding agent mixing with water as per manufacturer instruction. Mortar is properly compected in the area of rainforcement and finishing it to bring in line with contact with the exesting concrete surface or RCC wall. The mortar should have a minimium compressive strength 20N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 7 N/mm2 in 28 days, minimum tensile strength should be 2.5N/mm2 and water cement ratio of 0.18. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2, complete all as specified and directed. upto 25 mm average thickness and (upto 4 storey of building) NOTE:- Cement and sand mortar in proportion of 1:2 graded coarse sand with polymer admixed in proportions approved.
ditto all as per item No. 1.40 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.40 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and as directed. (upto 4 storey of building).
ditto all as per item No. 1.43 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 1.43 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of bldg / structure, upto 15 meter height, above GL, of incl addl rows of scaffolding in stepped manner as per requirement of site, made with minimum 40 mm dia MS Tube, placed 1.5 meter C/C (maximum), horizontal & vertical tubes joint with cup & lock system with MS Tubes, MS Tube challis, MS clamps and stair case system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of wk and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with bldg etc wherever reqd, if feasible, for inspection of wk at reqd locations with essential safety features for workmen etc complete as per dirns and approval of GE.
Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of bldg / structure, above 15 m to remaining bldg height, above GL, incl addl rows of scaffolding in stepped manner as per requirement of site, made with minimum 40 mm dia MS Tube, placed 1.5 meter C/C (maximum), horizontal & vertical tubes joint with cup & lock system with MS Tubes, MS Tube challis, MS clamps and stair case system in the scaffolding for working platform etc and maintaining it in a serviceable condition for execution of wk and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with bldg etc wherever reqd, if feasible, for inspection of wk at reqd locations with essential safety features for workmen etc complete as per dirns and approval of GE. Note for items No 1.46 & 1.47:- (1) The elevation area of structure (length X breath of building X height of bldg) cover with scaffolding shall be measured for payment purpose. (2) The payment shall be made one time only for execution of all items each face of bldg / structure. (3) After completion of work al scaffolding mtrls shall be removed from bldg / structure by the contractor and the same shall be the property of the contractor and rate to be quoted by the bidder accordingly.”
M&L for providing and inserting 12mm dia aluminium/ GI injection nipples along crack line honey combed area including drilling holes as required diameters upto depths from 40mm to 80mm or half the thickness of member (whichever is less) at required spacing as approved by GE for the concrete work surface upto 12 storey of building complete all as specified and as directed.
M&L for making groove of size 12 mm X 12 mm along the crack line on concrete surface, removing dust, foreign mtrls from crack line by blowing compressed air or other technology as approved by manufacturers and washing of crack line with water and including inserting 12 mm dia aluminium / GI injection nipples along crack line honey combed area including drilling holes as reqd diameters upto depths from 40 mm to 80 mm of half the thickness of member (whichever is less) at reqd spacing as approved by GE and including injection with approved putty (polymer modified cement mortar / polyester putty) and injected cementitious expanding grout admixture mtrls on washing and saturating the cracked surface by gun pumping from top most nipple and down wards and curing of putty completed as per manufactures instruction all as specified and as directed. (Any storey / height of bldg / structure) Note: Cementitious expanding grout admixture mtrls with PVC nozzles shall be measured and paid under respective Sch A item.
Supply & application cementitious expanding grout admixture with the cement slurry at a dosage 225 ml per bag cement and injecting with high pressure grouting pump through non return PVC nozzles prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left with in the old concrete mass. When the flow of grout stops or shows refusals or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface, complete as per manufacturer’s instruction as specified and as directed. (Any storey / height of bldg / structure).
Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm (upto 04 storey of building).
ditto all as per item No. 2.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for 50mm bore GI pipe 500mm length as in Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement and complete all as specified and as directed (upto 04 storey high building).
ditto all as per item No. 2.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F shear connector of 8mm dia Fe 550 CRS & requisite length on the surface to be repaired for the bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertically followed by coat of epoxy Zinc primer as per the specification mentioned in complete all as specified and as directed. (upto 04 Storey of Building).
ditto all as per item No. 2.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for. (upto 04 storey of building).
ditto all as per item No. 2.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.09 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Used and waste of steel formwork to sides of column, pillars, posts, stanchions for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.12 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Used and waste of steel formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed. (upto 04 storey of building)
ditto all as per item No. 2.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.15 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Used and waste of steel formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing horizontal or sloping and similar work exe 5 cm but not exe 10 cm thick complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.18 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Used and waste of steel formwork to chullah hoods, chajjas, troughs, parapets and similar items including edges for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.21 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.21 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for RCC for M 30 (Design Mix) using 20 mm graded crushed stone aggregate as in parapets, balcony, chajjas and similar work all as specified and directed (upto 04 storey of building).
ditto all as per item No. 2.24 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.24 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F TMT bars 10mm dia Fe 550 CRS and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.27 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.27 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. (upto 04 storey of building).
ditto all as per item No. 2.30 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.30 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.complete all as specified and as directed. (upto 04 storey of building)
ditto all as per item No. 2.33 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.33 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.36 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.36 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Demolition of Brickwork quoins, arches, pillars etc but excluding ashlar facings, dressed all store work and precast concrete articles built in cement mortar complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.39 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.39 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.(upto 04 storey High of building).
ditto all as per item No. 2.42 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.42 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for brick work withwith sub-class `B’ bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius and all as directed. (upto 04 storey of building).
ditto all as per item No. 2.45 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.45 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 2.48 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 2.48 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Rendering 15mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Rendering 20mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound applied as per manufacturers instructions shall be laid over 10mm thick plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and as directed. (upto 04 storey of building). (Note: WPC shall be measured and paid separately).
ditto all as per item No. 3.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for Rendering 5mm thick with CM (1:3) on or concrete surfaces and finished the surface even and smooth as in ceiling complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for prepration of new/old plastered surfaces and applying two coats of weather proof exterior emulsion paint (any colour/tint) with approved colour and pattern over a coat of approved alkali primer incl wall care putty as on walls of buildings complete all as specified and directed. (upto 04 storey of building) complete all as specified and as directed.
ditto all as per item No. 3.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.09 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M/L preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed.(upto 04 storey of building).
ditto all as per item No. 3.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.12 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M/L preparation for old surface and applying one coat of white wash on ceiling to match with the new one complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.15 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of acrylic distemper over a coat of primer with 3mm thick wall care putty. complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.18 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coat of oil emulsion distemper over a coat of primer and one coat of wall care putty to match with the new surface on wall. complete all as specified and as directed. (upto 04 storey of building) .
ditto all as per item No. 3.21 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.21 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L Preparing new plastered surfaces of wall and applying 3 coats of white wash on walls surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.24 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.24 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L preparation of old surface and applying one coat of white wash on wall surface complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 3.27 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 3.27 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply only Integral water proofing compound (ISI MARK). (upto 12 storey of building).
Dismantling of floor hearth or wall tiling including cement mortar and backing coat, and rubbish off the premises (out of MOD land), complete all as specified and as directed. (upto 12 storey of building).
Roughening of surface of old concrete floor by picking , sweeping clean and washing down with water to remove dust etc complete all as specified and as directed (upto 12 storey of building).
M & L joint free non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular)made out from cutting of tiles of area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed by Engineer-in-charge. (Note:- Backing coat/Screed bed shall be measured and paid Seperately under respective items of Sch "A") (upto 12 storey of building).
M & L non - skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed by Engineer-in-charge. (Note:- Backing coat/Screed bed shall be measured and paid Seperately under respective items of Sch "A") (upto 12 storey of building).
M&L backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:3) as in dado/skirting complete all as specified and as directed. (upto 12 storey of building).
M&L Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. (upto 12 storey of building).
M&L Non-skid coloured ceramic floor tiles 7 to 8 mm thick area of each tile exc .06 sqm but n exc 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to to match the shade of tiles complete all as specified and as directed. (Note:- Screed bed shall be measured and paid separately under respective items of Sch "A') (upto 12 storey of building).
M&L Glazed ceramic coloured wall tiles in vertical surface of size 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles overall including 10 mm thick rendering in CM (1:3) for recieving tiles complete all as specified and as directed. (upto 12 storey of building)
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling complete all as specified and as directed. (upto 12 storey of building).
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. (upto 12 storey of building)
Taking up or down 15mm steel tubing and connections, including removal from site complete all as specified and as directed.. (upto 12 storey of building).
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 including fittings as in walls, ceiling, floor, etc.complete all as specified and as directed (upto 12 storey of building).
Taking up or down 20mm steel tubing and connections, including removal from site complete all as specified and as directed.. (upto 12 storey of building) .
S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 including fittings as in walls, ceiling, floor, etc.complete all as specified and as directed (upto 12 storey of building).
Taking up or down 25mm steel tubing and connections, including removal from site complete all as specified and as directed.. (upto any height of building) .
S&F CPVC pipes 32 mm outer diameter of SDR 11 & plain CPVC SDR 11 including fittings as in walls, ceiling, floor, etc.complete all as specified and as directed (upto any height of building).
S&F in repair 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. (upto 12 storey of building).
S&F in repairs 15mm bore Brass CP bib cock fancy type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-JAGUAR Cat No CON 037KN or PARRYWARE Cat No- G1804AI
S&F in repair 15mm bore Brass CP two way bib cock fancy type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002163 or HINDWARE Cat No- F73004 or PRAYAG Cat No 8312.
S&F 15mm bore Brass CP angular stopcock concealed type with crutch or butterfly handle complete all as specified and as directed. (upto 12 storey of building). MAKE-CERA Cat No F3002201 or HINDWARE Cat No- F730039 or PRAYAG Cat No 8310.
S&F in repair PVC connection 15 mm size pipe with PTMT nut of Length 600mm complete all as specified and as directed. (upto 12 storey of building).
S&F in repair brass CP shower roses with or without swivel joints, with shower arm, 125mm size, including fixing to steel pipes or union complete all as specified and as directed. (upto 12 storey of building).
S&F Vitreous China wash basin (colour white), angle back, size 550X400 mm,waste,chain and plug and porcelain stopper but including cutting for and pinning in ends of and brackets, waste pipe & CP Brass waste coupling of 32mm dia and cast copper alloy pillar tap etc. complete all as specified and directed. (upto 12 storey of building). MAKE-HINDWARE Cat No 11008 or PARRYWARE Cat No- C0404 Note : Rate quoted under this item deemed included fixing of taps, plug and chain and connecting up to supply pipes, wastes or traps etc.
S&F 40mm bore UPVC pipe with fittings complete fixed in wall/laid in floor complete all as specified and as directed. (upto 12 storey of building) .
S&F 40 mm bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed. (upto 12 storey of building).
S & F in repair vitreous china squatting pan of Orissa pattern long pan of size 580 mm x 440mm with integral foot rest white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as specified and as directed by Engineer-in-Charge. (upto 12 storey of building). MAKE-PARRYWARE Cat No C0117 (WHITE) or HINDWARE Cat No 20042 (WHITE)
Supplying and fixing in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building). MAKE-PARRYWARE Cat No E8303 or HINDWARE PVC SLEEK SMART or PRAYAG Cat No 501S
S&F Stainless steel kitchen rack / plate rack of size 31"x36"x10", made of stainless steel sheet 0.63 mm thick etc complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F in repair CI Nahani trap of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F PTMT grating of 100mm dia, fixed with cement mortar (1:3).complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F Sinks made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm without draining board (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and as directed by Engineer-in-charge (upto 12 storey of building).
M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
M&L 25mm thick PCC 1:2:4 Type B-1 (using 20 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
M&L 40 mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) and concrete surface is to be finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each and refixing in the same opening complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube (size 19 Sqmm MS tube of 19 gauge),fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame (size 15 sqmm MS tube of 19 gauge) welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004),complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F 125 mm long Aluminium anodised, barrel tower bolts of extruded section all as specified and as directed.(upto 12 storey of building).
S&F 125 mm long Aluminium handles, cast type, anodised complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building)
S&F 100 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S & F Fixed type partly glazed, partly gauged. Solid PVC ventilator including 3mm thick frosted glass pane, 0.36mm dia & 1.4mm aperture stainless steel wire net, glazing clip, fastener etc complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.22 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.22 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F Steel window box type using ERW 'P' section comprising double frame for gauged and glazed skeleton shutter jointed internally with flat iron 40x3mm complete including hinges, handle tower bolts stops, lugs including stainless steel wire cloth meshing etc all as shown on drawing complete all as specified and as directed by Engineer-in-charge. Note:- (i) For the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) Unit are quoted against this items also include the iron mongeryas shown on drgs. (iii) Guard bars are included in the rate spacing of 12 mm square bar will be 10 cm centre to centre handle to opening will be provided. (iv) Glazing shall be measured and paid separately. (upto 04 storey of building).
ditto all as per item No. 4.25 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.25 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and fixing 3.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 4.28 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.28 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply & fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples complete, all as specified and directed. Complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.31 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.31 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supplying and fixing Mild Steel framed work such as grills, gratings, etc. with ends of bars soldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, railings and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed and design/shape approved by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.34 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.34 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material & labour preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.37 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.37 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for cement concrete ( 1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.40 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.40 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.43 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.43 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F CI spun pipes with out ears in any length fixed to wall with brackets of 100mm bore including bituminous paints both side complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.46 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.46 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F CI bend diminishing piece with door of 100mm bore with duct, foot and heel rest complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 4.49 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 4.49 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F CI branch pieces single equal or unequal with door of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.02 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.02 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S/F CI cowl of 100mm bore complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.05 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.07 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.10 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.10 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material & labour for preparation of old painted steel surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.13 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Material & labour for preparation of old painted wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.16 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 5.16 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and fixing in repairs 3.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.19 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.19 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply & fixing in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples and directed complete all as specified and as directed by Engineer-in-charge. (upto 04 Story of building).
ditto all as per item No. 5.22 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.22 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L welding 50 mm D type steel hinges to existing steel windows shutter and frame incl two coats of synthetic enamel paint over a coat of red oxide primer complete including making good all damages and all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
Taking down chowkat with shutter (without taking off shutters from the frame) area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.26 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.26 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F 2nd Class HW Plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chanfered, put together with glue pinned at joints complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.29 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.29 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F 35 mm thick 2nd class hard wood rail and style factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.32 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.32 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood gauged & skleaton shutter, open rebated & prepared to receiv e gauged, ( without sash bar ) eadge of framing plain, chamford or rounded, fitted with cut & mitred beads for securing gauged etc complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
ditto all as per item No. 5.35 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 5.35 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L for 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, articles n exc 200 Cubic cm each complete all as specified and as directed by Engineer-in-charge. (upto 12 storey of building).
S& F 50 mm long butt hinges medium weight cold rolled mild steel and fixed , complete all as specified and as directed. (upto 12 storey of building).
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section , complete all as specified and as directed. (upto 12 storey of building).
S&F mild steel Butt hinges 100 mm size,cold rolled mild steel, medium weight , complete all as specified and as directed. (upto 12 storey of building).
S&F 150 mm long Aluminium handles, cast type, anodised , complete all as specified and as directed. (upto 12 storey of building).
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast al alloy , complete all as specified and as directed. (upto 12 storey of building).
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete all as specified and as directed. (upto 12 storey of building).
M&L for 25x4mm size mild steel flat iron as in hold fast conforming to Fe-290 Gde E-165 complete all as specified and as directed. (upto 12 storey of building).
M&L PCC 1:2:4 Type B0 (using 12.5mm graded crushed stone aggregate) for fixing hold fasts, angle etc complete all as specified and as directed. (upto 12 storey of building).
S & F second class hard wood Beads, straight (n exe 3 Sqcm ) for glazed or gauzed joinery, renewed, including mitres etc complete all as specified and as directed. (upto 12 storey of building).
Taking down door shutter exe 1 Sqm and n exe 2 Sqm each after resecuring or easing and adjusting including refixing in same opening complete all as specified and as directed. (upto 12 storey of building).
Taking down Shutters of any description exc 2 Sqm each complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.00 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 6.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Taking down shutters of any description exceeding 1 Sqm and not exc 2 Sqm each complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.03 here-in-before but from 05 storied to 08 storied of building complete all as specified and as directed.
ditto all as per item No. 6.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M & L for Cub-boards shutters made with 19mm thick prelaminated particle board with decorative lamination on one side and other side balancing white lamination medium density, interior grade including 6mm teakwood lipping complete all as specified and as directed. (upto 12 storey of building).
S & F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm , complete all as specified and as directed. (upto 12 storey of building).
S & F 100 mm long Extruded Aluminium alloy handles, fabricated type, anodised , complete all as specified and as directed. (upto 12 storey of building).
S & F Aluminium Anodised Hasp and Staple, including bolt to hing plate and fixed with screws 100 mm size , complete all as specified and as directed. (upto 12 storey of building).
S&F 100mm long aluminium anodised barrel tower bolts of extruded section , complete all as specified and as directed. (upto 12 storey of building).
M&L for water proofing treatment to surfaces of roof slab of building in following sequence including demolition and removal of existing surfaces, including 20 mm thick plaster in CM (1:3 ) incl WPC (2% by weight of cement) complete all as specified and as directed by the Engr-in-Charge:-Supply and laying 3mm thick non woven polyester reinforced APP modified WP membrane (as per manufacturer's instruction) of 160 GSM spun bonded material in core and weighing not less 3.6 kg/sqm. One coat of bituminous primer shall be applied to the newly prepared concrete surface @ 0.3 Ltr/sqm overlaid by APP membrane using LPG torch application method and applying uniform pressure with a roller/wet cloth to remove entrapped air, if any. The overlap joint shall be 100mm in transverse direction and 75 mm in longitudinal direction. The membrane shall be finally painted on top with using Super Silver Shield @ 0.10 ltr/sqm complete all as directed. (upto 12 storey of building).
M&L RCC Type B1 (1:2:4) (20 mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.12 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.12 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
M&L Formwork flat fair finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.15 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Taking down Steel window and Ventilators of n.exc 1.5 Sqm including Grill/Guard Bars etc. complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.18 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with ( 2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with glazing and including 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter:- (A) Sections for shutter (i) 'H' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick (B) Section for frame (i) Top & Sides 123 X 29.70X 1.50mm not less than 1.30 Kg /RM (ii) Bottom 123 X 29.70 X 1.50mm not less than 1.502 Kg /RM complete all as specified and directed . (upto 04 storey of building).
ditto all as per item No. 6.21 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.21 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F flush shutter 30mm thick solid core construction with block board core and ply wood face pannel on both sides complete all as specified and directed . (upto 04 storey of building).
ditto all as per item No. 6.24 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.24 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, but partly gauzed i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be both side Prelam PVC sheet suppling & fixing in the frame at site as per specification & drawing. (upto 04 storey of building).
ditto all as per item No. 6.27 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.27 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Supply and fix stainless steel butt hinges medium weight,100mm long complete all as specified and as directed. (upto 12 storey of building).
S&F 150 mm extruded Aluminium handles fabricated type complete all as specified and as directed. (upto 12 storey of building).
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.32 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.32 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Taking up or down 40mm bore steel tubing of any grade and connections including fittings complete all as specified and as directed. (upto 12 storey of building).
Supply and fixing of Chlorinated polyethelene chloride ( CPVC) pipes 50mm out side dia , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings ( such as bend , elbow Tees , short pieces , connectors , Back - Nuts caps , plugs , union , flange , ( core ) and flange ( ring ) reduction Tee , reducing socket , Male & female threaded socket , tank connector etc ) fixed /laying walls , ceiling or in floors etc with suitable size MS clamp of spacing 1.00 mtr etc pipe line complete all as specified and as directed. (upto 12 storey of building).
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass of size 12 cm wide with CP bracket guard and railing 60 cm long complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.37 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.37 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F PVC soap tray with PTMT fixed to walls with screws complete all as specified and as directed. (upto 12 storey of building).
S&F in repair CP tubular towal rail 20mm dia, 'D' type 60 cm long between flanges fixed in wall etc complete all as specified and as directed. (upto 12 storey of building). MAKE-JAGUAR Cat No ACN1111NM or PARRYWARE Cat No- T6401A1
M & L for 75mm thick PCC 1:3:6 type C2(40mm graded stone agg) and finished the concrete surface even and smooth without using extra cement for plinth protection and filling the joints with bitminous joint filler in bitumen sand ratio 1:2 complete all as specified and as directed.
Supply and fixing of Cast iron floor trap with grating 100 mm outlet including jointing to waste pipe fixed in plain cement concrete type B1 ( 1:2:4) using 20 mm graded stone aggregate complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.43 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.43 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S & F rotational moulded polythene water storage tanks, three layered 2000 ltrs capacity(cylindrical, vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling old unserviceable one and removing out side of premises complete all as specified and as directed. (upto 12 storey of building).
S & F 20 mm ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed(minium weight 15 mm - 210 gms) including taking down old one complete all as specified and as directed. (upto 12 storey of building).
S&F in repair 75 mm dia PVC(SWR) pipes, single socketed, in any length, with rubber rings joints fixed to walls complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 6.48 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 6.48 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F in repair 75 mm PVC(SWR) junction/branches equal or unequal complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 7.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 7.00 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
S&F in repair 75 mm PVC(SWR) bend any radius complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 7.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 7.03 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Refixing existing old serviceable cast iron soil, waste/vent pipes of 100 mm dia in old position in cement joints after trhough cleaning of pipes complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 7.06 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 7.06 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. (upto 04 storey of building).
ditto all as per item No. 7.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
ditto all as per item No. 7.09 here-in-before but from 9 storied to 12 storied of building complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.00 kg of cement per sqm complete all as specified and directed. (upto any height of the building).
M & L (fixed in repairs) 12 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work etc complete all as specified and as directed. (upto any height of the building).
S & F aluminium alloy handles size 150mm fabricated type anodised complete all as specified and as directed. (upto any height of the building).
Material & labour flat iron mild steel for hold fast size conforming to Fe-410-0 or Fe-310-0. complete all as specified and as directed. (upto any height of the building).
S & F in repair helical door spring 300mm long incl roller and roller plate complete all as specified and as directed. (upto any height of the building).
S & F in repair tubular 20mm curtain rod chromium plated complete all as specified and as directed. (upto 12 storey of building).
S&F in repair brackets chromium plated for curtain rod in any size complete all as specified and as directed. (upto 12 storey of building).
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks, three layers (Cylindrical verticle with closed top) noisfed and fixed in position including taking down old one,complete all as specified and as directed.
uprooting of tree from walls of the buildings upto extranded root and spraying of acid of required quantity, complete from any location of building & upto any height of building and making good disturbed surfaces with cement mortar (1:4) or cement concrete type C1(1:3:6) using 20mm graded aggregate for tree of girth up to 5 to 10 CM.complete all as specified and as directed.
S&F in PVC ball valve 25mm high pressure of PTM with epoxy coated aluminium rod and high density plastic ball serewed for iron pipe fixed in repair. complete all as specified and as directed.
S&F in repairs of stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed.
M&L for 125x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plate, etc complete all as specified and as directed.
M&L for 105x60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strikes plate, etc complete all as specified and as directed.
S & F in repairs polycarbonate cabinet with mirror of size 450mmx450mm fixed with screw complete all as specified and as directed.
M & L for water proofing treatment with APP modified membrane 3mm thick consisting of the following for RCC Roof:- (a) dismantaling/demolition of roof treatment as directed. (b) cleaning plastered roof surface and applying a coat of oxidised bitumin based primer @ 0.3kg/sqm of approved make on top of dry surface of RCC roof complete all as specified and directed. (c) M & L for app modified polymeric water proofing membrane weight not less than 3.0kg/sqm with centre core as 100 micorne hmhdpe film. the centre core is sand wiched on both side by high quality polymeric mix with property of high softening point. the polymeric mix is protected on both side with 20 microne hmhdpe film with lap of 100mm and the overlap shall be sealed by flame complete all as per manufacturer's instructions and as directed by Engr-in-Charge. (d) M & L for applying a tack coat of industrial bitumen 85/25 @ 1.2kg/sqm including cleaning surface. (e) Brushing neat cement slurry with 3kg of cement per sqm. (f) M & L cement concrete roof tile 25 x 25 x 20mm thick machine pressed set, jointed and pointed in neat cement slurry in roof over 15mm thick screed bed in cm 1:4.
SCHEDULE 'A' PART-II (ELECTRICAL WORKS)
Disconnecting the electrification and taking down DBs (any type of SPN DBs) and making good to the disturbed surfaces to match the existing surface and complete all as specified and as directed. Note: Temporary Power supply by temporary connection from nearby sources shall be provided by contractor at own source.
Taking down unserviceable submain wiring any type and size etc and making good distrubed surfaces of walls, floors, etc matching the existing surface and complete all as specified and as directed.
M&L Sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 4 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 4 Sqmm as earth lead drawing into rigid non metalic PVC conduit of size 20mm diaand complete all as specified and as directed. Note:Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length.
ditto all as per item No. 8.03 here in before but with two run of single core 6 sqmm and one run of 6 sqmm cable and complete all as specified and as directed.
Taking down carefully unserviceable copper / aluminium point wiring (light, fan, socket or power) including all fittings such as switches, socket, ceiling roses and fittings complete and making good the disturbed surfaces with all as directed by Engineer-in-Charge.
M&L for point wiring with PVC insulated unsheated stranded copper conductor cable of size 1.5 sq mm in and including PVC cassing caping of required width with all necessary fittings with sunk cast iron /pressed steel terminal box of 1.6mm wall thickness and 3 mm thick laminated sheet top cover for mounting switches including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan/bell controlled by one switch complete all as specified and directed by Engineer incharge. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No. 8.06 here-in-before but for one light point controlled by two switches, complete all as specified and as directed.
All as per item No. 8.06 here-in-before but for one ceiling fan controlled by one switch , complete all as specified and as directed.
All as per item No. 8.06 here-in-before but for one exhaust fan controlled by one switch, complete all as specified and as directed.
All as per item No. 8.06 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switch, complete all as specified and as directed.
All as per item No. 8.06 here-in-before but for one bell/buzzer point controlled by one push button, complete all as specified and as directed.
All as per item No. 8.06 here-in-before but for one 3 pin socket outlet 5 Amps on the idependent board, complete all as specified and as directed.
All as per item No. 8.06 here-in-before but using 2.5 Sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board, complete all as specified and as directed.
S&F stepped type (0-4) electronic requlator for ceailing fan 1200 mm , 240 Volts, 100 Watts, single pole, including connecting, testing complete all as specified and as directed.
S&F door bell, AC,230 Volts, single pole complete all as specified and as directed.
S&F bell push switch,single pole, one way flush type, 05 Amps, 240 Volts complete all as specified and as directed.
S&F socket outlet, flush type , 3 pin, 6 Amps, 240 Volts complete all as specified and directed.
S&F switch piano flush button single pole one way 5 Amps 240 Volts complete all as specified and as directed.
S&F switch piano flush button single pole two way 5 Amps 240 Volts complete all as specified and as directed.
S&F socket combination, flush type multipurpose, 3 pin, 6 Amps, 240 Volts complete all as specified and directed.
S&F switch socket combination multi - purpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch shutter type, complete all as specified and as directed.
S&F Polycarbonate/PVC ceiling rose, surface Bakelite, 65x50 mm three terminals, complete all as specified and as directed.
M&L for lamp holder insulated body with back plate for batten fittings, complete all as specified and as directed.
S & F MCB TPN DB made up with sheet metal, phosphorised, powder coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 240 volts and complete all as specified and directed.
S&F isolator 63 Amps 415 Volts triple pole and neutral with rapturing capacity 10KA and complete all as specified and directed.
S&F Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar and complete all as specified and directed.
S & F in repairs MCB SPN DB made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 12 way with 200 amps rated bus bar, 240 volts and complete all as specified and directed.
M & L Sheet Metal enclosures for DB's for MCBs Single pole & neutra 2 way with out bus bar single door and complete all as specified and directed.
S&F "C" series RCBO, 32 Amps, current rating, residual rated current 30 mA, 240 Volts, 10 KA, AC type and complete all as specified and directed.
Material and labour for PVC insulated armoured heavy duty electric cable with aliminium conductor 1100 volts grade cross sectional area 16 sqmm 4 Core fixing in PVC conduit including of all accessories complete and complete all as specified and as directed by the Engr-in-Charge.
Supply and fix pressure die cast aluminum housing LED Building security light luminaries 20 Watts with and including Electronic driver and 1 x20 Watt LED lamp and 50 mm dia light grade GI pipe bent to shape of 45 degree, pre-wired including necessary electric connection copper flexible PVC cable of 0.50 sq. mm three core not more than one metre in length from ceiling rose/connector to light fitting, conforming to the following specifications: - (i) System Watts/lumens: - Max 20 W/Total system lumen not less than 2400 Lumens,Voltage Range: 140 to 270 Volts, Continuous operation of 2 Hours at 320 Volts. (ii) Housing: - High pressure die cast aluminium body (iii) IP rating: - Minimum IP 65 (iv) Mounting: - Suitable for pole mounting with bracket arm 40-50 mm die, mounting height 5.50 M to 6.50 M from GL(v) Finish: - Epoxy powder coated with additional treatment for smooth and anti corrosive finish (vi) Lamp: - High bright LED with lens (vii) System Efficacy of Luminaire (lumens/Watt): - Not less than 120 lumens/watt (viii) Colour temperature: - Not less than 5700 degree K (ix) Colour rendering index (CRI): - Not less than 70 (x) Life: - Not less than 50000 hrs of operation (xi) Optics: - spread (Beam angle along the driveway) 120 Degree, through (Beam angle across the driveway)-120 degree, Beam Pattern-Symmetrical. (xii) Control gear: - Inbuilt electronic driver with APFC, PF not less than 0.95, and THD not more than 20% of the standard operating voltage 180-270V Ac, 50 Hz (xiii) Surge protection: - Inbuilt surge protection minimum 2.5 KV (xv) Heat sink: - As per OEM's design.
S&F MCB double pole 20-32 Amps, 240 Volts, 50 Hz, "C" Curve including necessary incomming and outgoing electric connection with suitable size of copper lugs and complete all as specified and directed.
S&F MCB SP, 6 to 32 Amps, 240 Volts, 50 Hz, "C" Curve including necessary incomming and outgoing electric connection with suitable size of copper lugs and complete all as specified and directed.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal of excavated soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Taking down old unserviceable existing service/UG cable complete all as specified and as directed.
M&L for brush less DC(BLDC) ceiling fan with following specification:- (i) Motor:- Brushless DC Maximum 26 W, with operating voltage 140V-240V AC,50Hz. (ii) Max RPM:-360 RPM (iii) Sweep:- 1200mm (iv) Colour:- White (v) Remote control operated. (vi) 5 Star energy saving rating. NOTE:-Old unserviceable fan shall be taking down and to be deposited to E/M store yard by the contractor.
S&F exhaust fan 250 mm sweep heavy duty complete with blades and louvers and making connection with copper flexible PVC cable of 0.50 sq mm twin core not more than one meter in length complete all as specified and as directed by the Engr-in-Charge. NOTE:-Old unserviceable fan shall be taking down and to be deposited to E/M store yard by the contractor.
S&F exhaust fan 300 mm sweep heavy duty complete with blades and louvers and making connection with copper flexible PVC cable of 0.50 sq mm twin core not more than one meter in length complete all as specified and as directed by the Engr-in-Charge. NOTE:-Old unserviceable fan shall be taking down and to be deposited to E/M store yard by the contractor.
Supply and fixing 5 star rated water heater(geyser) storage type Ennergy effient SPHP Technology inner container ,A.C single phase 230 Volt,50 Hz of storage capacity 15 ltrs Vertical type complete connecting upwater heater/geyser , including reqd hold fast 10cm long including washers and complete all as specified and as directed by the Engr-in-Charge
S& F for DLP 80x50mm plastic trunking cable tray riser DB to DB for sub main wiring including making good surface and completed all as specified and as directed by the Engr-in-Charge
Taking down carefully the exixting FTL/LED light fittings of any wattage and any size by unscrewing from wall/outlet boxes and fixtures and keeping in safe custody for reuse at site and refixing the same after completion of new wiring work in same location, complete all as specified and as directed by the Engr-in-Charge. (Note:- Any breakage/damage of light fitting during taking down /re-fixing shall be make good by the contractor with his own cost).
Hindustan Traders
DNS CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .