Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC | L1 | Accepted-AOC reasonable rate | |
| 2 | L2₹31.6 L+₹1.3 L (4.43%)Rejected-Finance | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | L3₹31.9 L+₹1.6 L (5.28%)Rejected-Finance | L3 | Rejected-Finance Quoted amount higher than L1 | |
| 4 | L4₹32.7 L+₹2.4 L (7.89%)Rejected-Finance | L4 | Rejected-Finance Quoted amount higher than L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not having requisite category |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Amit Chaubey
HQ 137 Wks Engr PIN 914137 c/o 99 APO
REPAIRS / MAINT OF HT UG CABLES AT VARIOUS LOCATION IN DISTRIBUTION SYSTEM, REPAIRS GODS, OH LINES AND CONNECTED ACCESSORIES AT RMS AND DIMAPUR
2024_MES_675958_1
8977/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Rangapahar
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 868 EWS
₹60,000
Yes
7 Jan 2025
23 Sept 2024
28 Oct 2024
23 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 120 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 complete all as specified and as directed. Note : Earth work, sand cushioning, Precast Cable cover will be measured and paid separately under respective item.
Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 185 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 complete all as specified and as directed. Note : Earth work, sand cushioning, Precast Cable cover will be measured and paid separately under respective item.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including testing on completion complete all as specified and as directed.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm including testing on completion complete all as specified and as directed.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) gradecable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including testing on completion complete all as specified and as directed.
Supply and fixing in repair Cable jointing kit for 11 KV (Earthed) gradecable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm including testing on completion complete all as specified and as directed.
Supply and fixing in repair Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 to 240 sqmm including testing on completion complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for foundation of poles, cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed.
Supply and fixing expulsion type drop out fuse unit suitable for 11000 volts and current rating upto 400 Amps shall be mounted on pole and including MS channel complete with 02 Nos. post insulator for 11000 volts including necessary clamps, nuts, bolts, washers and the exposed steel surfaces shall be painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply and fixing in repair triple pole mechanically operated air break isolator (GOD), polymer type vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz with 9 insulator of rating upto 400 Amps complete all as specified and as directed.
Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity minimum 65 KA suitable for working voltage of 11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 including dismantling of old unserviceable lightening arrester complete all as specified and as directed.
Supply and fixing in repair Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
Shifting of transformer 11/0.433 KVA to a distance not more than 5.00 Kms from power house/ any other place to required place, including disconnecting and neccesaary connection and testing after shifting complete all as directed. Note : Required T& P, vehicle, labours and techenician deemed to be included in the quoted rate.
Supply and fixing in repair male contact for air break switch complete all as specified and as directed.
Supply and fixing in repair female contact for air break switch complete all as specified and as directed.
Supply and fixing in repairs parallel groove bimettalic PG clamp to hold transmission conductors in parallel of dia uo to 80mm complete all as specified and directed.
Disconnecting all electrical connection from Air Break Switch (GOD) vertical/ Horizontal Type of any capacity, cleaning all parts and applying jelly/ greasing to all moving parts for smooth functioning including replacement of unserviceable parts like Pin/Post Insulator, Male/ Female contact, DO fuses, GOD handles, Nut, bolts & washers etc. complete all as specitfied and as directed. Note: The spare parts reqd for repair/replacement shall be measured and paid as supply only under relavant items and fixing of the same is deemed to be inclusive in this Item.
Supply only brass terminal plate for mounting male contact of air break switch insulator including GI nuts, bolts and washers etc as required complete all as specified and directed.
Supply only pin/ post insulator for air break switch of capacity 400 Amp with hardware suitable for HT 11 KV conforming to IEC-62217-2012 complete all as specified and directed.
Supply only high conductivity copper wire mesh jumper 400 Amps rating for air break switch 11 KV complete all as specified and directed.
Supply and fixing in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for upto 400 KVA , 11 KV rating transformer complete all as specified and as directed.
Supply and fixing drop out fuse top/bottom contact suitable for 11 KV complete all as specified and directed.
Supply only new transformer oil of dielectric strength not less than 60 KV and conforming to IS-335 of 1993 for filling / topping up of transformer up to desired level including core washing complete all as specified and directed.
M & L for purification, filtration and Dehydration of transformer oil of transformer installed at various outdoor/indoor substation by ultra high vacuum filtration machine with strem line filtration plant at temperature 60 to 70 degree celcius and achieving minimum dielectric strength of 60 KV for 1 minute in 2.5mm gap setting complete all as specified and directed. Note: (a) Contractor shall ensure no wastage of transformer oil. (b) Transformer oil required extra for refilling / topping up shall be measured and paid separately under the relevant item of this schedule. (c) Cost for testing of oil including T&P shall deemed to be included in the quoted rate. (d) Contractor shall be ensure that the conservator tanks are full to its level before starting its dehydration.
Material and Labour for replacement of cable lugs with aluminium alloy tubular bimettalic terminals of size 120 sqmm incl crimping with help of crimping tools complete all as specified and directed.
Disconnecting electrical connection, dismantling and taking down old unserviceable ACSR jumpers (PVC insulated / bare conductor) any size and type including supply and fixing of new jumpers with PVC insulated 12 KV volt grade ACSR upto 1.5 metre length and winding with insulators or ACSR conductor with suitable size wire complete all as specified and directed.
Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for PCC (1:2:4), type B1, (using 20mm graded stone aggregate), as in coping including necessary formwork complete all as specified and as directed.
Removal of unwanted grass, plants and vegetations from E/M installations including surface dressing and removal of grass, plants and vegetations from site not less than 50 mtr from starting point complete all as specified and directed.
PERFECT BUILDERS AND SUPPLIERS (BID ID -3144980)
M/S Lucky Builders (BID ID -3145800)
M/S PIJUSH BHATTACHARJEE (BID ID -3143691)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .