Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DARJEELING WEST BENGAL 734201 | DARJEELING | WEST BENGAL | 734201 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹9.8 L+₹42,023 (4.50%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹10.2 L+₹84,231 (9.03%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹10.3 L+₹94,231 (10.1%)Rejected-Finance | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹10.3 L+₹97,133 (10.4%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
| Sl No | Description | Qty | Unit | Darjeeling Enterprises L6 | JALAPAHAR HARDWARE L7 | HIRA SINGH L2 | REEMA TAMANG AND SONS L1 | BHASKAR PRADHAN L5 | RAI CONSTRUCTION L3 | THUKKEPA & PANGDOK L4 | Damdoo Bhutia L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc, complete all as per specified and as directed by Engineer-in-charge. | 183 | Per Point | 112 ₹20,496 | 147 ₹26,901 | 115 ₹21,045 | 105 ₹19,215 Lowest | 134 ₹24,522 | 127 ₹23,241 | 125 ₹22,875 | 116 ₹21,228 |
| 2.00 | Taking down DB's including MCB's etc., complete all as per specified and as directed by Engineer-in-charge. | 19 | Each | 76 ₹1,444 | 73 ₹1,387 | 56 ₹1,064 | 48 ₹912 | 82 ₹1,558 | 69 ₹1,311 | 76 ₹1,444 | 44 ₹836 Lowest |
| 3.00 | Taking down carefully unserviceable sub main wiring of any size / core / type including making good the disturbed surfaces, complete all as specified and as directed by Engineer in Charge. | 200 | RM | 56 ₹11,200 | 44 ₹8,800 | 49 ₹9,800 | 35 ₹7,000 | 67 ₹13,400 | 34 ₹6,800 Lowest | 60 ₹12,000 | 38 ₹7,600 |
| 4.00 | M&L for point wiring with PVC un-sheathed and PVC insulated cable with stranded FRLSH copper conductor cable 1.5 Sqmm size in and including PVC Conduit medium grade ISI marked of required size including PVC fittings like elbow, bends, etc. and factory made PVC surface modular/ non modular box as per site for installation of switch/sockets etc ISI mark incl screw and rawa plug etc and also one No. of 1.5 Sqmm single core PVC FRLSH insulated copper cable for continuous earth wire connected to earth dolly for one light /Bell point controlled by one 5 Amp switch one way & and making good disturbed surface of walls & floors etc, complete all as specified and as directed by Engineer in Charge.
Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code. | 10 | Per Point | 1,450 ₹14,500 | 1,293 ₹12,930 Lowest | 1,425 ₹14,250 | 1,325 ₹13,250 | 1,447 ₹14,470 | 1,393 ₹13,930 | 1,347 ₹13,470 | 1,440 ₹14,400 |
| 5.00 | M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLSH cable 1.5 Sq mm size 1100V grade in and including PVC casing caping double lock type of size not less than 25X16mm including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for one light /Bell point controlled by one 5 Amp switch one way including factory made PVC modular/ non modular box sutaible for switch/sockets etc ISI marked and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer in Charge.
Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code. | 96 | Per Point | 1,350 ₹1,29,600 | 1,631 ₹1,56,576 | 1,320 ₹1,26,720 | 1,250 ₹1,20,000 Lowest | 1,520 ₹1,45,920 | 1,331 ₹1,27,776 | 1,320 ₹1,26,720 | 1,360 ₹1,30,560 |
| 6.00 | All as per serial item No. 05 above but for one light pointcontrolled by Two 2-way switches. | 1 | Per Point | 1,451 ₹1,451 | 1,453 ₹1,453 | 1,350 ₹1,350 | 1,300 ₹1,300 Lowest | 1,490 ₹1,490 | 1,543 ₹1,543 | 1,500 ₹1,500 | 1,505 ₹1,505 |
| 7.00 | All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps on same Board. | 20 | Per Point | 410 ₹8,200 | 413 ₹8,260 | 335 ₹6,700 | 303 ₹6,060 | 195 ₹3,900 Lowest | 403 ₹8,060 | 315 ₹6,300 | 360 ₹7,200 |
| 8.00 | All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps, independent Board. | 20 | Per Point | 1,542 ₹30,840 | 1,523 ₹30,460 | 1,324 ₹26,480 | 1,257 ₹25,140 Lowest | 1,427 ₹28,540 | 1,432 ₹28,640 | 1,327 ₹26,540 | 1,435 ₹28,700 |
| 9.00 | All as per serial item No. 05 above but for Two socket outlet, 3 pin 5/6 Amps, independent Board. | 10 | Per Point | 1,350 ₹13,500 | 1,421 ₹14,210 | 1,350 ₹13,500 | 1,299 ₹12,990 Lowest | 1,420 ₹14,200 | 1,324 ₹13,240 | 1,320 ₹13,200 | 1,565 ₹15,650 |
| 10.00 | All as per serial item No. 05 above but for four socket outlet, 3 pin 5/6 Amps, independent Board with 2.5 sqmm copper wire. | 6 | Per Point | 1,650 ₹9,900 | 1,620 ₹9,720 | 1,700 ₹10,200 | 1,588 ₹9,528 Lowest | 1,710 ₹10,260 | 1,675 ₹10,050 | 1,610 ₹9,660 | 1,755 ₹10,530 |
Tender Value
₹9.2 L
EMD Value
₹18,400
Closing Date
18 Aug 2025, 6:00 pmClosed
AGE I DARJEELING
AGE I DARJEELING JALAPAHAR CANT DIST - DARJEELING
REPAIR/MAINT OF INTERNAL ELECTRIFICATION AND ALLIED WORKS IN VARIOUS STORES AND OFFICE ETC AT LEBONG UNDER AGE (I) DARJEELING
2025_MES_721605_1
8144/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
LEBONG
AS PER NIT
9 documents required · 9 mandatory
₹500
AGE I DARJEELING
₹18,400
Yes
15 Sept 2025
21 Jul 2025
20 Aug 2025
21 Jul 2025
18 Aug 2025
5 Aug 2025
Amount
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc, complete all as per specified and as directed by Engineer-in-charge.
Taking down DB's including MCB's etc., complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable sub main wiring of any size / core / type including making good the disturbed surfaces, complete all as specified and as directed by Engineer in Charge.
M&L for point wiring with PVC un-sheathed and PVC insulated cable with stranded FRLSH copper conductor cable 1.5 Sqmm size in and including PVC Conduit medium grade ISI marked of required size including PVC fittings like elbow, bends, etc. and factory made PVC surface modular/ non modular box as per site for installation of switch/sockets etc ISI mark incl screw and rawa plug etc and also one No. of 1.5 Sqmm single core PVC FRLSH insulated copper cable for continuous earth wire connected to earth dolly for one light /Bell point controlled by one 5 Amp switch one way & and making good disturbed surface of walls & floors etc, complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLSH cable 1.5 Sq mm size 1100V grade in and including PVC casing caping double lock type of size not less than 25X16mm including one No. 1.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for one light /Bell point controlled by one 5 Amp switch one way including factory made PVC modular/ non modular box sutaible for switch/sockets etc ISI marked and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code.
All as per serial item No. 05 above but for one light pointcontrolled by Two 2-way switches.
All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps on same Board.
All as per serial item No. 05 above but for One socket outlet, 3 pin 5/6 Amps, independent Board.
All as per serial item No. 05 above but for Two socket outlet, 3 pin 5/6 Amps, independent Board.
All as per serial item No. 05 above but for four socket outlet, 3 pin 5/6 Amps, independent Board with 2.5 sqmm copper wire.
M&L for Point wiring with PVC un-sheathed and PVC insulated cable with stranded copper conductor FRLSH cable 2.5 Sq mm size 1100V grade in and including PVC casing caping double lock type of size not less than 25X20mm including one No. 2.5 Sq mm single core PVC insulated copper cable for continuous earth wire (green coloured) connected to earth dolly complete for socket outlet 15/16 Amps on independent board including factory made PVC modular/ non modular box sutaible for switch/sockets etc ISI marked and making good disturbed surface of walls & floors etc., complete all as specified and as directed by Engineer in Charge. Note - Wiring shall be circuit type and Nos of conductor in conduit shall be taken as per relevant IS Code.
M&L for modular switch one way 6/10 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular switch two way 6 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular bell push 6 Amps 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
S&F Switch Piano flush button single pole one way 5 Amp, 240 volt, complete all as specified and as directed by Engineer in Charge.
M&L for modular socket, 6 Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
S&F Socket outlet 2 in 1, 3 pin, 5 Amp, flush type, universal, 240 volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular socket, 6 Amps / 16 Amps - 2/3 pin combined 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular switch one way 16 Amps, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
S&F Switch Socket Combination 5 in 1, 5 and 15 Amp flush type universal, 240 volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular blank plate, 1 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 2 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 3 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 4 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 6 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 8 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
M&L for modular white cover plate with frame, 12 module, 240 Volts, complete all as specified and as directed by Engineer in Charge.
S&F Bell Ding-Dong, AC, 230 V, Single Pole, complete all as specified and as directed by Engineer in Charge.
M&L for Ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts, complete all as specified and as directed by Engineer in Charge.
S&F in repair wall mounted LED Tube light fitting 20 watt surface mounted general purpose LED Batten in Extruded Aluminium housing including making connections with 2 core flexible copper wire 0.50 sqmm from ceiling rose after fixing fitting in position at site on 02 Nos new PVC blocks, complete all as specified and as directed by Engineer in Charge. Make - Havells Cat part No. - LUMILINEPLUSNEOBS20WLED865SPCSSIND or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
S&F in repair wall mounted LED Tube light fitting 10 watt surface mounted general purpose LED Batten in Extruded Aluminium housing including making connections with 2 core flexible copper wire 0.50 sqmm from ceiling rose after fixing fitting in position at site on 02 Nos new PVC blocks, complete all as specified and as directed by Engineer in Charge. Make - Havells Cat part No. - LUMILINEPLUSNEOBS10WLED865SPCSSIND or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
Supply and fixing in repair lamp holder, PVC/Polycarbonate type with back plate suitable for batten/angular fitting, complete all as specified and as directed by Engineer in Charge.
Supply and fix in repair switch piano flush type, 5 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair socket outlet, 3 pin, 6 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair socket outlet, 5 in 1, 15/16 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
S& F in repair of Decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser/ acrylic diffuser suitable with 9 W LED lamp B22 base complete including dismantling the old one, complete all as specified and as directed by Engineer in Charge. Make : Cat Part No. LHFOAJE1Z1I060 of Havells or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
S&F in repair of LED surface mounted decorative Bulk Head fittings 10 watts duly fixed on suitable PVC/ wooden Box and connection, complete all as specified and as directed by Engineer in Charge. Make : Cat Part No. RUGBYGENXFTS10WLED865SSYMBOPC of Havells or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
S&F in repair of Bed side light fittings white or black/ white in colour 7 watt, lumen output 400 lm/3000K minimum with inbuilt switches two nos including suitable mounting box, complete all as specified and as directed by Engineer in Charge. Make : Cat Part No. 31437 of Philips or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
S&F in repair of bluiding security light new generation energy saving & enviornmental friendly, long life, versatile pressure die-cast aluminium, IP66 with high power LED as light source with acrylic cover of LED 30 Watt luminaire and suitable size of bracket, clamping with nut & fastener, complete all as specified and as directed by Engineer in Charge. Make - CAT Part No. -ENDURASUNDOWNSL30WLED757PASYBOPC of Havells or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
M&L for sub-main wiring with two single core 4.0 Sqmm PVC (FRLSH) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non-metalic PVC casing caping (25x20 mm) with and including PVC insulated 4.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and as directed by Engineer in Charge. Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
M&L for sub-main wiring with two single core 6.0 Sqmm PVC (FRLSH) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through non-metalic PVC casing caping (32x16 mm) with and including PVC insulated 6.0 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, complete all as specified and as directed by Engineer in Charge. Note : Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid as one unit.
S&F in repair/replacement of MCB DB, TPN 4 way, 415 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB DB, SPN 12 way, 240 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB DB, SPN 8 way, 240 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB DB, SPN 4 way, 240 volts, double door type with sheet metal enclouser suitable for mounting incoming and outgoing MCBs, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB, Single Pole, 240 volts of capacity 6-32 Amps, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB, SPN, 240 volts, 50 Hz of capacity 40-63 Amps, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
S&F in repair/replacement of MCB, TPN, 240 volts, 50 Hz of capacity 40-63 Amps,'C' curve, 10 KA rupturing capacity, complete all as specified and as directed by Engineer in Charge. Note - Taking down of old DB incl MCBs shall be measured and paid under serial item No. 02.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Taking down seviceable light fittings of any description, keep in safe custody for refixing and refixing to existing/ new position incl all allied accessories, complete all as specified and as directed by Engineer in Charge.
Taking down seviceable distribution boxes, keep in safe custody for refixing and refixing to existing/ new position duly fixed on new wooden boxes of suitable size incl all allied arrengements, complete all as specified and as directed by Engineer in Charge.
Taking down seviceable MCBs of any capacity, keep in safe custody for refixing and refixing to existing/ new position incl all allied arrengements, complete all as specified and as directed by Engineer in Charge.
Taking down seviceable switch/ socket/ holder/ ceiling roses etc keep in safe custody for refixing and refixing to existing or new position incl all allied arrengements, complete all as specified and as directed by Engineer in Charge.
S&F in repair of LED surface/recess mounted 2x2 ft luminaire 36 Watt with high performance LEDs and made out of sheet steel housing suitable for armstrong/ grid/ pop ceiling etc incl all allied accessories and connection, complete all as specified and as directed by Engineer in Charge. Make : Cat Part No. VENUSTREND2X2PLR36WLED857SWH of Havells or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents.
S&F in repair of LED surface/recess mounted 1x1ft luminaire 18W with high performance LEDs and made out of pvc/ sheet steel housing suitable for various type ceiling etc incl all allied accessories and connection , complete all as specified and as directed by Engineer in Charge. Make - Cat Part No. PLUTO1X1PLR18WLED857SG2/ PLUTO1X1PLS18WLED857SG2 of Havells or equivalent model of makes as mentioned in "List of Makes" of Particular Specification of the Tender Documents. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
HIRA SINGH (BID ID -3396600)
RAI CONSTRUCTION (BID ID -3397722)
THUKKEPA & PANGDOK (BID ID -3393999)
BHASKAR PRADHAN (BID ID -3396221)
Darjeeling Enterprises (BID ID -3393338)
JALAPAHAR HARDWARE (BID ID -3398156)
Damdoo Bhutia (BID ID -3397343)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .