| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹4.7 L+₹12,173.60 (2.66%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹7.0 L+₹2.4 L (52.1%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹7.2 L+₹2.6 L (57.0%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | Vishav Karma Refrigeration and Electric Work L4 | M/S SAROOP ELECTRICAL & MECHANICAL WORKS L2 | VIRAT CONSTRUCTIONS L1 | Dhani Builders L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage room unit by leak testing with N- 2 gas under constant pressure of 250 PSI after complete transfer of refrigerant gas from the entire system, rectification of leakage by cutting and brazing the refrigeration system wherever required. Replacement of 'O' Ring tefflon washer of valves copper tubing, safety valves, flare nuts etc. Neutralising after the pressure hold good for atleast 24 hours vaccumisation, charging the system with refrigerant gas including complete testing at site all as specified and directed. Note:- Gas charging including in the quoted rate and no extra payment to be made. | 1 | Each Job | 24,999 ₹24,999 | 5,000 ₹5,000 | 4,500 ₹4,500 Lowest | 22,000 ₹22,000 |
| 2.00 | M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by tightening / rectification of electric circuit of all units and controll wiring , phase seqquence, including replacement of fused indication lamp, cleaning of all power contacts, rectification of minor defects complete testing at site all as specified and directed. | 1 | Each Job | 9,999 ₹9,999 | 6,000 ₹6,000 | 2,000 ₹2,000 Lowest | 20,000 ₹20,000 |
| 3.00 | M&L for Temprature controller unit range -40 degree to 50 degree temp auto cutup system and maintain suitable tempratue in cold storage room with complete wiring and connection and testing complete all as specified and directed. | 2 | Each | 10,999 ₹21,998 | 7,000 ₹14,000 | 1,050 ₹2,100 Lowest | 25,000 ₹50,000 |
| 4.00 | M&L for ML-2 contactor single phase 40 amps with complete fixing and connection for evaporater unit of cold stroage room and testeing all as specified and directed. | 2 | Each | 10,999 ₹21,998 | 4,000 ₹8,000 | 1,050 ₹2,100 Lowest | 4,500 ₹9,000 |
| 5.00 | M&L for cut out fuse 32 Amps baklite with suitable size fuse complete all as specified and directed . | 4 | Each | 9,999 ₹39,996 | 3,000 ₹12,000 | 200 ₹800 Lowest | 850 ₹3,400 |
| 6.00 | M&L for general servicing/ repair and maintenance of window type AC's of capacity 1.5/2.0 TR comprising of the following tasks at different location of any condition & and transporting to contractor workshop to carry out necessary repair including refixing at site, commissioning, testing, painting of AC's and writing of MES Number complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any part found unserviceable / defective shall be measured and paid separately under respective item here-in-after. (ii) Make of parts shall be as per original window type AC. | 6 | Each Job | 999 ₹5,994 | 1,000 ₹6,000 | 80 ₹480 Lowest | 1,000 ₹6,000 |
| 7.00 | S&F in replacement of air filter of window type AC 1.5/2.0 TR capacity asper existing Make & Model as required at site complete all as specified and directed. Make: - Coir foam or equivalent make ISI marked. | 6 | Each Job | 449 ₹2,694 | 300 ₹1,800 Lowest | 300 ₹1,800 Lowest | 450 ₹2,700 |
| 8.00 | S& F in replacement of cooling coil as per existing Make and Model suitable for 1.5/2.0 TR capacity window air conditioner commissioning & testing complete all as specified and directed. | 5 | Each Job | 1,999 ₹9,995 | 1,300 ₹6,500 Lowest | 3,500 ₹17,500 | 2,500 ₹12,500 |
| 9.00 | S&F in replacement of fan & blower motor as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specfied and directed. | 2 | Each Job | 1,999 ₹3,998 | 1,800 ₹3,600 | 1,550 ₹3,100 Lowest | 2,000 ₹4,000 |
| 10.00 | S&F in replacement of fan blade as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specified and directed | 6 | Each Job | 449 ₹2,694 | 570 ₹3,420 | 210 ₹1,260 Lowest | 1,000 ₹6,000 |
Tender Value
₹7.5 L
EMD Value
₹14,500
Closing Date
11 Jun 2025, 6:00 pmClosed
AGE(I) DALHOUSIE PIN-176305
AGE(I) DALHOUSIE
CERTAIN MAINT WORK TO REFRIGERATOR AC PLANT AND OTHER APPLIANCES WORK AT DALHOUSIE BAKLOH AREA
2025_MES_707973_1
9110/2025-26/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) DALHOUSIE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹14,500
Yes
AGE(I) DALHOUSIE
12 Sept 2025
15 May 2025
18 Jun 2025
15 May 2025
11 Jun 2025
29 May 2025
15 May 2025 - 24 May 2025
24 May 2025
Amount
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage room unit by leak testing with N- 2 gas under constant pressure of 250 PSI after complete transfer of refrigerant gas from the entire system, rectification of leakage by cutting and brazing the refrigeration system wherever required. Replacement of 'O' Ring tefflon washer of valves copper tubing, safety valves, flare nuts etc. Neutralising after the pressure hold good for atleast 24 hours vaccumisation, charging the system with refrigerant gas including complete testing at site all as specified and directed. Note:- Gas charging including in the quoted rate and no extra payment to be made.
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by tightening / rectification of electric circuit of all units and controll wiring , phase seqquence, including replacement of fused indication lamp, cleaning of all power contacts, rectification of minor defects complete testing at site all as specified and directed.
M&L for Temprature controller unit range -40 degree to 50 degree temp auto cutup system and maintain suitable tempratue in cold storage room with complete wiring and connection and testing complete all as specified and directed.
M&L for ML-2 contactor single phase 40 amps with complete fixing and connection for evaporater unit of cold stroage room and testeing all as specified and directed.
M&L for cut out fuse 32 Amps baklite with suitable size fuse complete all as specified and directed .
M&L for general servicing/ repair and maintenance of window type AC's of capacity 1.5/2.0 TR comprising of the following tasks at different location of any condition & and transporting to contractor workshop to carry out necessary repair including refixing at site, commissioning, testing, painting of AC's and writing of MES Number complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any part found unserviceable / defective shall be measured and paid separately under respective item here-in-after. (ii) Make of parts shall be as per original window type AC.
S&F in replacement of air filter of window type AC 1.5/2.0 TR capacity asper existing Make & Model as required at site complete all as specified and directed. Make: - Coir foam or equivalent make ISI marked.
S& F in replacement of cooling coil as per existing Make and Model suitable for 1.5/2.0 TR capacity window air conditioner commissioning & testing complete all as specified and directed.
S&F in replacement of fan & blower motor as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specfied and directed.
S&F in replacement of fan blade as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specified and directed
M&L for charging of Refrigerant (R-22) to 1.5/2.0 TR Air conditioner up to maintain reqd temperature as per site condition complete all as specified and directed. Note :- (i) Refrigernat (R-22) shall be deemed to be included in the quoted rate. (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be including in the quoted rate.
S&F in repair compressor Hermatically sealed unit suitable for 1.5/2.0 TR AC window type ISI marked suitable for working on 230 volts single phase including filling of gas R-22 of required quantity including testing on full load complete all as specified and as directed. make- Emerson copland or equivalent approved make.
S& F in replacement of Running capacitor 36/45 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S& F in replacement of Starting capacitor 80/100 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S&F in replacement of Electronic circuit board for window type air conditioners suitable for 1.5 Ton AC window type ISI marked as per the existing make complete all as specified and directed..
S&F in replacement of Gas filter for 1.5/2.0 Ton AC make: Vijay /Goldstar
S&F in replacement of Thermostat switch for 1.5/2.0 Ton AC make: Renutrol/Indfoss complete all as specified and directed.
S&F in replacement of Front grill suitable size Make: Gem/Usha/Fedferlloyed/ Carrier air conditioner.
M&L for general servicing/repair & maintenace of Refrigerator 165 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the refrigerator after repairing and testing complete including welding / Brazing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/ detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory funtioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat (vi) Inspection of all electrical parts (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unservicable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Refrigerator.
Supply and fixing in replacemrn of old unserviceable spare parts of Refrigeratator for capacity 180 ltr to 310 ltr and fixing new spare partrs with complete testing after completion of work complete suitable for make (Whirlpool/ classic/Godraj/LG) and list of items for PTC relay OLP HE 48/115 (Make: Whirlpool / Classic / Godrej / LG)
PTC relay OLP HE 48/115 (Make: Whirlpool / Classic / Godrej / LG)
Door handle suitable for 165 - 310 Ltrs capacity refrigerators.
Overload protector for refrigerator 1/6 HP (Make: Whirlpool / Classic / Godrej / LG)
Overload protector for refrigerator 1/8 HP (Make: Whirlpool / Classic / Godrej / LG)
Thermostat suitable for 165-310 Ltr refrigerator (Make: Ranutrol /Indfoss)
Vibration Pad for AC Compresssor of Refrigerator any capacity
Water waste tray for Refrigerator suitable for 310/315 Ltr capacity
Section pipe insulator for Refrigerator suitable for 310/315 Ltr capacity
Stand Shoe for Refrigerator
Freezer Door frame for Refrigerator suitable for 310/315 Ltr capacity
Bulb holder for Refrigerator
Bulb Cover for Refrigerator suitable for 310/315 Ltr capacity
Vegitable Tray glass for Refrigerator suitable for 310/315 Ltr capacity
Vegitable Tray glass for Refrigerator suitable for 180/190 Ltr capacity
Freezer Hings
Healing Condenser for Refrigerator suitable for 310/315 Ltr capacity
Base Plate for Refrigerator suitable for 310/315 Ltr capacity
Door lock for Refrigerator 310/190 Ltr capacity
Door switch for Refrigerator 310/190 Ltr capacity
Heating condeser for Refrigerator 190 Ltr capacity
Compressor guard plate for Refrigerator suitable for 310/315 Ltr capacity
Freezer door Frame for Refrigerator suitable for 180/190 Ltr capacity
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 165-190 Ltr complete all as specified and directed. Gas charging will be measured and paid saparately.
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 215-315 Ltr complete all as specified and directed. Gas charging will be measured and paid saparately.
Disconnecting and taking down refrigerator (165 to 320 Ltr Cap) of any make and size for repairs & including detecting of leakage in the system rectifying the same, dehydration & recharging of gas (R-134a) & testing the refrigerator for smooth & satisfactory operation complete all as specified and directed .NOTE:- (i) Filling / recharging of gas (R-134a) shall be deemed to be included in the quoted rate (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate.
S&F in repair ice chamber (Freezer) for 165 / 175 /285 /300 /315 Ltr refrigerator surrounded by frezzer pipes complete all as specified and as directed . Make : Whirlpool / Kelvinator / Godrej /LG
Supply and fixing in replacement of cooling coil for 285 / 300 / 310 Ltr of any make refrigerator. Make: Whirlpool / Godrej/LG
Supply and fixing in replacement of cooling coil for 165/175 Ltrs of any make refrigeratror. Make: Whirlpool/Godrej/LG
Supply & fixing in replacement of single phase, wall mounted copper wound, air cooled type with digital display of output voltage 220V ± 9% and calibration accuracy ± 3% Voltage stablizer 5 KVA, range of 170-260V all as specified and directed by Engr-in-Charge. Make:- Volina / V Guard / Aplab
M&L for opening of the stablizer/A/C protectors, removing of the all internal parts, replaceing of the unserviceable PCB, rewidning of T/F replacement of indicating lamp, volt meter fuse cutout, relay reconnecting back and testing complete of the following size all as specified and directed. (a) 0.5 KVA capacity
As per ser items No 50, 1 KVA capacity
As per ser items No 50, 5 KVA capacity
M&L for general servicing/repair & maintenace by authroised dealer/ representative of Deep Freezer 300 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc. including fixing new parts with new parts with new nut bolt and washers etc reassembling the Deep Frezzer after repairing and testing complete including welding / Brezing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system (iv) check and correct all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning (ix) Testign of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Deep Freezer.
S&F in repair compressor Hermatically sealed unit suitable for 320 Ltr deep freezer of existing make suitable for working on 230 volts single phase with filling of gas R-22 of required quantity including testing on full load complete all as specified and directed.
Supply and replacing old u/s cable and fixing of PVC cooper cable 4 sqmm 3 core for all connection with stablizer, refrigerator, deep freeaers all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure with single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB of capaicty, 20 Amps 230 Volts including removing of the old U/S all as directed Make:- Stanard.
S&F plug top 3 pin 5 Amps 230 Volts including removing of the old U/S all as directed.
All as per item No.33 above but 15 Amps
M&L for writing SM No. MES No. etc. on Refrigerator, Deep freezer & AC at site approved shade/color of synthetic enamel paint , hight of letter 20/40 mm and up to 20 Nos in words/Figures complete all as specified and directed
M&L for servicing of waterpurification system with replacement of choked filter, memberan, pvc pipe, UV protection memberan with complete cleaning and proper testing of water after complete replacement of all unserviceable items inside the waterpruification system for capacity of 8 Ltr to 14 Ltr for make of Kent/ Aquaguard or equivalent other make all as specified and directed by Engineer-in-Charge
M&L for servicing of water Dispenser system with replacement of water guard, up middle plate, switch plate, hot thermostat, drier filter, hot taps, drain box with fillign of refregent ges R-134a with complete testing of Cold and Hot water system and proper testing of all electrical wiring after complete replacement of all unserviceable items inside the Water Dispenser system for capacity of 20 Ltr for make of VOLTAS or equivalent other make all as specified and directed by Engineer-in-Charge
Supplying, fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as in repairs/replacement of old unserviceable cable of following sizes all as specified and directed.(a) 2 core 10 Sqmm
All items as per ser No 62, 4 core 16 Sqmm
M&L for sand cushioning for cable protection 8 cm below the cable and 15 cm above the cable complete all as specified and directed
Supply and lay burnt bricks sub class `B’ of size 230x115x75mm laid dry over sand cushioning in trenches as protection on the cable all as directed
Excavation in trenches in any type of soil n. exc 1.5mtr wide and n. exc 1.5mtr depth for GI tubing and getting out in Hard/dense soil all as specified.
M&L for returning, filling in including sperading, leveling watering and well ramming in layers n. exc 25 cm thick each layers in soil all as specified and directed.
M&L for removal of surplus soil to a distance not exceeding 50 mtr and deposting where directed and at a level not exceeding 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground any type of soil including rock soil alos (earth pit not less than 2.25 Mtr below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron lead wire 4.0 mm as earthing lead by means of bolts, nuts, check nuts, as earth lead complete including 40mm bore dia protection pipe GI medium grade upto 7.5 mtr length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part-I and connected to earthing test point, main board including testing on completion all as specified and as directed by Engr-in-charge.
Repair of door of cold storage room with replacement of hinges, door handle, rubbered Door Gasket along with supporting strip, Alumimium plain sheet of thickness as per exisiting sample for Cold room Plant and repaired door fixed on cold storage room complete all as specified and directed.
S & F LED Bulb 12 Watt rechargeable emergenc inverter LED bulb, cool day light, white upto 4 hours backup and auto cut-off after full charge Model: Bajaj/Phillips/ Havells/Crompton/Wipro all as specified and as directed.
MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps Cat ref no. 4200 53 of make Legrand or equivalent in M/s Schenider/M/s Siemens – 03 No.
Supply and fixing in replacement of old MCB Triple pole and nuetral 63 Amps, 240 volts, 50 Hz Make: Havells/Schinder, Legrand incl replacement of old u/s MCB complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC, White recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and direcred.
Supply and fix LED batten fitting 20w with engineering plastic housing mounted on wall/surface connecting with all required accessories like square box for mounting on wall, flexible cable from ceiling rose etc as directed and specified by engr-in-charge. Havells cat part No Havells cat part No LUMILINEBS10WLED865SPCWH or equivalent in Bajaj, CG.
M/S SAROOP ELECTRICAL & MECHANICAL WORKS (BID ID -3309889)
Dhani Builders (BID ID -3320107)
Vishav Karma Refrigeration and Electric Work (BID ID -3313372)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .