Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest and Quoted rates are reasonable | |
| 2 | L2₹48.1 L+₹4.6 L (10.5%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹51.7 L+₹8.2 L (18.9%)Rejected-Finance PULGAON | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹52.8 L+₹9.3 L (21.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹52.9 L+₹9.4 L (21.5%)Rejected-Finance 58 CHANDRALOK BUILDING MAYO HOSPITAL ROAD NAGPUR 440 018 | NAGPUR | MAHARASHTRA | 440018 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
1 Apr 2024, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP PULGAON PIN 442303
REPAIR / REPLACEMENT STREET LIGHTS AND OTHER MISC WORK AT PERIMETER AND DEPOT AREA UNDER GE PULGAON
2024_MES_645833_1
8109/PUL/E8
Open Tender
Civil Works
Item Rate
270 days
GE PULGAON
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE PULGAON
₹90,000
Yes
7 May 2024
9 Mar 2024
8 Apr 2024
9 Mar 2024
1 Apr 2024
27 Mar 2024
9 Mar 2024 - 26 Mar 2024
Amount
Disconnecting and taking down exiting unserviceable Street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. Repairing/replacing unserviceable parts refixing the same on pole/wall after testing and removing of carbon from line jumpers/Tightening of jumper/alligment of fitting defective street light/security light/flood lights fitting/LED light from electric pole complete all as directed by EIC. Note: Spare parts and accessories such as LED Driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included under this item.
Supply only LED street light Driver for 45 Watts LED Street light complete all as specified and directed.
Supply only LED street light Driver for 60 Watts LED Street light/ Flood light type complete all as specified and directed.
Supply and fix in repair LED streetlight of 45 Watt comprises of pressure die cast Aluminium housing & having system efficiency>123 lumens/Watt i.e 5570 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K,PF>0.9,Driver efficiency>85%,LM79 report require from NABL Accediated lab including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge. Make : Havells cat part No ENDURASUNBEAMSL45LED757SASYTOPC or equivalent make in Wipro/Phillips
Supply and fix in repair LED streetlight of 60 Watt comprises of pressure die cast Aluminium housing & having system efficiency>110 lumens/Watt i.e 6670 lumns,All LEDs should be highpower LEDs of 1W to 3W Only with moduler lens for batwin shape distribution of 30 degree & 60 degree,Input voltage working range is 140 Vac to 270 Vac,Brand name should be emoboised,Potted Driver is used with 4KV internal & external 5KV Potted surge protection,Short Circuit Protection,Open Circuit Protection,High & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,IP66 Protected,THD<10%,CRI>70CCT 5700+/-300K, PF>0.9, Driver efficiency>85%,LM79 report require from NABL Accediated lab including taking down old unserviceable fittings complete all as specified and directed by Engr-in-Charge. Make : Havells cat part No ENDURASUNBEAMSL60LED757SASYTOPC or equivalent make in Wipro/Phillips
Supply and fixing in repair LED flood light 100 watt 230 V AC, 3000K outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down old unserviceable fittings complete all as directed by EIC. Make : Havells cat part No JETAADORNFLS100WLED757PR1SYMTOTG or equivalent make in Wipro/Phillips/ Havells
S&F in repair 1100 volts grade 2.5 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC shathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm dia GI suspension wire including disconnection and removing the unserviceable cable.
Supply only 1100 volts grade 4 Sqmm twin core flat heavy duty cable PVC insulated,PVC sheet with aluminium conductors, multistranded served with an inner sheathing of PVC tape and overall PVC sheathed complete all as specified and as directed.
S&F in repair street light bracket made out of 25mm dia light grade pipe 1.2 mtr long bend to shape along with two FI clamp made out of 20mmx3mm including nut, bolt, washers all as directed and taking down the existing bracket.
M & L Earthing complete with galvanised earth plate electrode 60cmx60cmx6.3 mm thick buried directly in ground nut less then 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead 32 x6 mm iron strip by means of bolts, nut check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to main switch distribution board complete and testing on completion all as specified and directed by Engr-in-charge. Note : The unit rate shall also includes for excavation and earth work, in/any type of soil, pit in PCC 1:3:6 type C1 funnel with watering pipe 20mm bore GI medium grade, earth lead protection pipe 40mm bore GI medium grade, RCC 1:2:4 type B1 cover for earrth chamber, 50mm thick with 8mm dia TMT bar 150mm C/C both ways & 6mm dia MS round bars as handles of cover slab all as specified.
Supply & Fix in repair steel tubing GI light grade 50mm bore for cable protection passing under Road/Floor or for fixing to poles all as specified and directed.
M&L for Preparation of old painted surfaces of steel tubular poles 9/11 Mtr long including cross arms protection pipe and painting one coat of aluminium paint from 2.1 mtr above ground level to top of pole and cross arms and protection pipe and painting of bottom area of pole upto 2.1 mtr from ground level with synthetic enamel paint in alternate bay ( 30 cm wide) with black and yellow paint including writing poles numbers in white letter on black ground complete all as specified and directed by Engr-in-Charge.
Taking out LT XLPE/PVC insulated armoured cable alongwith all joints of any size from trenches wall/roof/trenches complete all as directed by Engr-in-Chrage.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 2 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 25 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 16 Sqmm including laying, testing and commissioning complete all as specified and directed.
Supply and laying XLPE LT 1100 volts underground earthed cable, PVC bedded, galvanized steel strip or wire armoured, electric power cable heavy duty 1100V with multi stranded, aluminum conductor of cross sectional area 4 core x 10 Sqmm including laying, testing and commissioning complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engr-in-charge.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, watering, and well ramming complete all as directed by Engr-in-Chrage.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point all as directed by Engr-in-Chrage.
Supply and fixing Double wall Corrugated High Density Polymer Ethylene (HDPE) pipe of size 50 mm diameter as per IS 14930 (Part-2):2001, Laid in trenches/floors and fixed on walls/poles, with and including neccessary fittings such as bends, sockets and other connected accessories etc., for laying of electric cables, complete all as specified and as directed.
S&F MCB TPN 63 amps 415 volts Complete all as specified and directed including taking out old one.
S&F MCB SPN 32 amps 230 volts Complete all as specified and directed including taking out old one.
Supply and fix Galvanised steel tubes, light grade of 40 mm dia fixed with Clamp in PCC pole including Cement work all as directed BY Engr-in-Charge.
Road cutting for laying UG cable under road /railway crossing, pavement, hardstanding by mannually means, protection GI pipe for cable of required dia and making it good to match with the adjoining surfaces/structure for after cable passing including PCC 1:3:6 complete all as specified and directed. Note :- GI Pipe will be measured and paid against respective item.
Supply and fixing in repair 1100 volts grade 0.75 Sqmm three core FR PVC round sheathed copper conductors (flexible) industrial cable confirming to IS694suitable for connection street lights all as directed by Engr-in-Charge, .
Supply and fixing in repair loop in / loop out box of internal size 250 x 210 x 115mm made out of FRP (Hot moulded type) with weather proof canopy and locking screws alongwith 5/6 Amps MCB-01 No, 15 Amps rated 3 pole connector - 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector complete in the box, duly fixed to steel tubular pole using 25 x 3mm FI clamp with suitable gland and lugs for connecting cable including taking down old one complete all as specified and as directed.
Repair/Replacement of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure with hinged Enclosure conforming to IP-66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option).Two-phase load of 2x8 kw (Swadeep-66-16 kw 3P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm with two nos Contactors,two nos.Incoming MCBs & 2 nos.Outgoing MCBs of 40-63 Amps each & Circuit wiring (Copper) of min.10 sq.mm.
Repair/Replacement of Automatic Street light Control Switch using Infrared Sensor based Nature Switch for automatic switching of street lights. Nature Switch operation should be based on Natural light Lux level.Required illumunance Level for Switching ON is<30 Lux and for Switching OFF >10 lUX.The sensor should also have part night operation facility of min .4 hrs to max.12 hrs .The sensor along with suitable power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Rust proof,Electric shock proof,Termite proof and FR grade thermoplastic polycarbonate Enclosure conforming to IP66 protection class 2. The Circuit should also have provision for Manual Operation(i.e sensor By -pass option) Single-phase load of 8 kw(Swadeep-66-8kw 1P) with Contactor,Incoming MCB & Outgoing MCB rating of 40-63 Amps & Main load Circuit Wiring(Copper) of min.16 sq .mm
MAHARASHTRA ENTERPRISES
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S. ELECTROPOWER TECHNOLOGIES
SHUBHAM SALES
SHREE SIDDHIVINAYAK TRADERS
Bidder Name
SHRI RANI SATI TRADERS
SHREE SIDDHIVINAYAK TRADERS
MAHARASHTRA ENTERPRISES
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S. ELECTROPOWER TECHNOLOGIES
SHUBHAM SALES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .