Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | ₹2.2 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹2.2 LRejected-AOC | ₹2.2 L | L2 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | G R RAJASEKAR L2 | NARPAVI TRADERS L1 |
|---|---|---|---|---|---|
| 1.00Name of Work:Repair and Renovation of Panchayat Union Primary school at Ammanpuram in Ammanpuram Panchayat. | |||||
| 2.00 | Dismantling of damaged Clean removal of cement plaster from walls and racking out joints 20mm deep including cost and conveyance of all labour charges etc and conplete | 31.76 | Sqm | 7.97 ₹253.13 | 7.97 ₹253.13 |
| 3.00 | Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work. | 26.62 | Sqm | 271.7 ₹7,232.65 | 271.79 ₹7,235.05 |
| 4.00 | Distmantling of Existing damaged Floor finish and dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs including cost and conveyance of all labour charges etc and complete | 82.24 | Sqm | 57.69 ₹4,744.43 | 57.69 ₹4,744.43 |
| 5.00 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data) | 4.55 | Sqm | 1,291.73 ₹5,877.37 | 1,291.73 ₹5,877.37 |
| 6.00 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M.Sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. | 93.43 | Sqm | 1,321.89 ₹1.2 L | 1,321.89 ₹1.2 L |
| 7.00 | Distempering the old walls and ceiling one coat with best oil bound distemper of approved quality including preparation of surfaces (the colour and quality should be got approved by the Executive Engineer before use) the rate includes cost of brushes, high scaffolding charges, neat finishing, cost of brushes etc., complete complying with standard specification and as directed by the Departmental Officer | 26.62 | Sqm | 132.37 ₹3,523.69 | 64.38 ₹1,713.80 |
| 8.00 | Wiring with 2 × 4 sq. mm PVC insulated SC unsheathed FRLS copper conductor cable of 1100 V grade in suitable pipe on wall and ceiling with PVC accessories, with 150 mm × 100 mm × 113 mm TW switch box for 15 A 3-pin non-interlocking wall socket with 15 A flush type switch, with painting of suitable colour, with continuous earth wire connection of 4 sq. mm copper wire for open PVC .plug point SD 39 | 8 | No | 1,554.08 ₹12,432.64 | 1,554.08 ₹12,432.64 |
| 9.00 | Wiring with 2 × 1.5 sq. mm PVC insulated unsheathed FRLS SC copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories, with TW switch box with 5 A FT switch in flush with wall, covered with hylum sheet of 3 mm thickness, with painting of suitable colour, for open PVC light / fan point (for electronic regulator) (5 points per coil). SD 22 | 13 | No | 1,444.08 ₹18,773.04 | 1,444.08 ₹18,773.04 |
| 10.00 | Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. SD 110 | 3 | No | 2,030.16 ₹6,090.48 | 2,030.16 ₹6,090.48 |
Tender Value
₹2.6 L
EMD Value
₹2,580
Closing Date
18 Feb 2026, 3:00 pmClosed
Block Developmenet officer (VP)
Block Developmenet officer (VP)
Repair and Renovation of Panchayat Union Primary school at Ammanpuram in Ammanpuram Panchayat.
2026_RDTN_654572_1
T2/0361/2026
Open Tender
Civil Works - Buildings
60 days
Tiruchendur Union
As per Tender Schedule
4 documents required · 4 mandatory
₹0
₹2,580
Panchayat Union office, Tiruchendur
22 Apr 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
18 Feb 2026
10 Feb 2026
17 Feb 2026
Dismantling of damaged Clean removal of cement plaster from walls and racking out joints 20mm deep including cost and conveyance of all labour charges etc and conplete
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothy with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The Surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (waterproof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. [ The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (waterproof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coat of putty, scrapping the putty area to level the surface smooth, etc., complete]. The Putty shoule be got approved by the Executive Engineer before use on work.
Distmantling of Existing damaged Floor finish and dadooing walls in cement mortar with Mosaic Tiles / Glazed Tiles / Clay Tiles / Cuddapah Slabs including cost and conveyance of all labour charges etc and complete
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data)
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M.Sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Distempering the old walls and ceiling one coat with best oil bound distemper of approved quality including preparation of surfaces (the colour and quality should be got approved by the Executive Engineer before use) the rate includes cost of brushes, high scaffolding charges, neat finishing, cost of brushes etc., complete complying with standard specification and as directed by the Departmental Officer
Wiring with 2 × 4 sq. mm PVC insulated SC unsheathed FRLS copper conductor cable of 1100 V grade in suitable pipe on wall and ceiling with PVC accessories, with 150 mm × 100 mm × 113 mm TW switch box for 15 A 3-pin non-interlocking wall socket with 15 A flush type switch, with painting of suitable colour, with continuous earth wire connection of 4 sq. mm copper wire for open PVC .plug point SD 39
Wiring with 2 × 1.5 sq. mm PVC insulated unsheathed FRLS SC copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories, with TW switch box with 5 A FT switch in flush with wall, covered with hylum sheet of 3 mm thickness, with painting of suitable colour, for open PVC light / fan point (for electronic regulator) (5 points per coil). SD 22
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. SD 110
Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting SD 88
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_784867.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
TechnicalBidsinglecoverRenovationofPanchayatUnionPrimaryschoolatAmmanpuramPanchayat.pdf
Tender Documents • 0.58 MB
BOQ_784867.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid