| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹27.5 L+₹2.6 L (10.3%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹30.8 L+₹5.9 L (23.7%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹34.4 L+₹9.5 L (38.2%)Rejected-Finance | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹28.4 L
EMD Value
₹56,800
Closing Date
24 Jul 2023, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR C/O 56APO
PROVN OF SCURITY LIGHTS AND SPECIAL REPAIR TO STREET LIGHTS AND SOLAR STREET LIGHTS WITHIN AOR OF AGE E/M UNDER GE (SOUTH) AKHNOOR.
2023_MES_605679_1
GES/AKH-14/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS D AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹56,800
29 Aug 2023
26 Jun 2023
26 Jul 2023
26 Jun 2023
24 Jul 2023
10 Jul 2023
Amount
Dismantling of ACSR or AAC conductors, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of insulators of any type and any description, complete all as specified and as directed by Engineer-In-Charge.
Dismantling of old LT panels alongwith all accessories and fittings of any type and any description, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old stay strand of any specification with new stay strand galvanised, 7/4mm, complete all as specified and as directed by Engineer-In-Charge.
S&F LED Post Top with a system lumen output of 1625 lumens and a minimum system efficacy of 70 lm/W. The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 18W (including driver) and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make : Bajaj Cat Part No BJCPTI 118 Opal or Equivalent makes in Havells/Crompton
PVC insulated FRLS cable, unsheathed, multi-stranded aluminium conductor 1100 volt grade, size 6.0 Sqmm, twin core for connection from overhead line to junction box including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, complete all as specified and as directed by Engineer-In-charge.
Factory made junction box/ cut-out box Water proof, made with 3.15mm thick CRCA mild steel sheet, vermin proof, dust proof, for outdoor use, having internal dimensions 280x170x130, painted externally & and internally, front openable, suitable for pole mounting, having one No MCB of 6 Amps, Single Pole, including aluminium bus bars of 200 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing on poles, complete all as specified and directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and not exceeding 1.50mtr in depth; not exceeding 10 Sqm on plan and getting out, in any type of soil, for foundations/ laying of cables/pipes, complete all as specified and as directed by Engineer-In-Charge.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning filling in incl spreading watering and well ramming in layers in hard/dense soil each not exceeding 25cm thick complete all as specified.
Removing excavated materials/ soils, to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed by Engineer-In-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified.
GI pipes/ Tubes, 'light grade', galvanised, 50mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete Nominal Mix M-7.50(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, complete all as specified and as directed by Engineer-In-Charge.
Tubes, Light grade' galvanised, 50mm bore, ISI marked with all fittings and fixed to walls or laid in floors for lightening conductor/ as in post top lanterns or as directed, complete all as specified and as directed. Note: Cost of cutting/ chasing for pipe line making concealed in surfaces shall be deemed included in quoted rates.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filling with fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe of GI tubing light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates reduced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
S&F/laying in replacement of LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note : - (Earth work, brick protection and sand cushioning shall be measured and paid for separately).
1100V Grade L.T. Aerial Bunched Cable of size 3x70 + 1x16 + 1x50 sq.mm (Phase Wire + Neutral Wire + Insulated Messenger Wire) having three Power Core & One insulated Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. Neutral Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments, if any, composition of phase wire, neutral wire and messeanger wire all shall conform to manufacturer instructions subject to compliance with Electricty manual /Indian Electricity Act -2003, and there by changes in the size of messeanger and neutral wire, nothing shall be admissible on this ground, including necessary connecting accessories like Anchor Clamps (3 Bolt and 2 Bolt Type), Eye hook with Suspension Clamp Assembly, PCC Pole Clamp, Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover,Water Proof pre-insulated Hexagonal Compression Connectors & Lugs etc , complete all as specified and as directed by Engr-in-Charge. Make: Havells/ Poycab/ Finolex/ Gloster Cables Ltd/KEI.
1100V Grade L.T. Aerial Bunched Cable of size 3x16 + 1x16 + 1x16 sq.mm (Phase Wire + Neutral Wire + Insulated Messenger Wire) having three Power Core & One insulated Messenger Core of stranded compacted circular Aluminium Black coloured XLPE insulated & Core identification by ridges, one, two and three & four respectively. Neutral Wire should be of stranded compacted Circular Aluminium Alloy Conductor conforming to IS 8130/1984, IS-398(Part-IV)/1979 and IS-14255/1995 with upto date amendments, if any, composition of phase wire, neutral wire and messeanger wire all shall conform to manufacturer instructions subject to compliance with Electricty manual /Indian Electricity Act -2003, and there by changes in the size of messeanger and neutral wire, nothing shall be admissible on this ground, including necessary connecting accessories like Anchor Clamps (3 Bolt and 2 Bolt Type), Eye hook with Suspension Clamp Assembly, PCC Pole Clamp, Insulation Piercing Connectors with cover or P.G.Connectors with insulation cover,Water Proof pre-insulated Hexagonal Compression Connectors & Lugs etc , complete all as specified and as directed by Engr-in-Charge. Make: Havells/ Poycab/ Finolex/ Gloster Cables Ltd/KEI.
Replacement of old damaged, PCC poles with new steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of poles including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-7.50 (1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Plain cement concrete M-10 (1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as in or as mass concrete in foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged Mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge.
Supply, installation, testing and commissioning of solar street light, all in one type , system voltage 12V, capacity not less than 30 W, Li-Fe Solar Street Light system mentioned below includes LED street Light with in-built SCC, SPV Panel, LiFeP04 Battery, HDG Tubular Pole not less than 125 Lum/Watt system level and rating voltage 12.8 volt DC, solar panel type mono crystaline panel, Lithium Ferro Phosphate (LiFEPo4) Battery and current capacity not less than 36 Ah with colour temperature 5350-7000K (Say cool white), PWM/MPPT charge controller and including fixing and any other necessary connected items for mounting on solar street light poles as per Munufacturer's instructions including taking down of existing solar street light of any type and wattage and all as specified and directed by Engineer in charge. Make: Havells Cat part No LHSTAPU7AAAI030/ CG Cat Part No. CSADSMP30CDL-NC, or equivalent in Philips/. Note : All necessary Earth work as in excavation, returing filling and removal and PCC work with form work and other allied items to complete the Job in all respect shall be deemed to have included in quoted rates and nothing extra shall be paid extra on this aspect.
Replacement of old unserviceable/ damaged battery with new storage cell lead acid type, rechargeable lead, environmental friendly, long life, 12 Volts, 150 AH with higher efficiency >90% and WH efiiciency > 80% float vent plug for electrolyte level indicator covered HDPE material caps, C10 rated solar battery, including lead terminals and copper thimble for making necessary connections, complete all as specified and as directed by Engineer-In-Charge. Make - Exide/ AMCO Insta Power/ Amaron Quanta as approved
Replacement of old unserviceable/ damaged loop type with new loop type insulator, vitreous porcelain, white, brown or green, with overall dimensions 65x90mm, clearance of hole 16mm, for 1100 volts grade, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged stay assembly with new stay assembly, galvanised iron, complete with accessories as shown in electrical plate No-1, diameter of stay rod 20mm dia, including galvanised iron stay plate 300x300x6mm, galvanised iron thimble, 14mm dia 400mm long stay bow and galvanised iron nuts bolts, washers including loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 65x90mm, clearance of hole 16.0mm, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and PCC shall be measured and paid separately under relevant item of Schedule ‘A’/ BOQ.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 7700 Lm and system wattage not exceeding 70W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection including House service bracket for mounting light fittings House service bracket any type complete with 1.50mtr long galvanised iron pipe 40mm dia medium grade, bent to required shape including mild steel clamps of flat iron 40x6mm, hook, stay, nut, bolt and washer including painting with two coats of synthetic enamel paint over one coat of red oxide primer , complete all as specified, complete all as specified. Make :Havells cat part No ENDURAOMNIPLUSSL70WLED757SASYTOPC or Equivalent makes in Wipro/Philips/CG/Crompton.
Amount of Schedule of credit of for Rs 1,48,890.00 shall be deducted from quoted amount.
MAMTA ENTERPRISES
Usha Engineering Co.
CHOPRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .