Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.8 LAccepted-AOC 0 GHULAM MOHAMMAD AND CO 0 GURUDAWARA II RAWALPORA SRINAGAR JAMMU AND KASHMIR RAWALPORA SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹28.0 L+₹1.8 L (6.96%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹29.2 L+₹3.1 L (11.7%)Rejected-Finance KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹31.4 L+₹5.2 L (19.8%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹33.5 L+₹7.4 L (28.1%)Rejected-Finance | L-5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | M/S NAZIR CONSTRUCTION L5 | M/S GHULAM MOHAMMAD AND CO. L1 | M/s GHULAM NABI HAJAM L6 | M/s Jaipal Associates L4 | M/S ZAHOOR ENTERPRISES L7 | M/S RATHER CONSTRUCTION CO L3 | M/S NEW FAROOQ TRADERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces as per existing, complete all as specified and directed. | 846 | Per Point | 10 ₹8,460 | 1 ₹846 Lowest | 5 ₹4,230 | 5 ₹4,230 | 10 ₹8,460 | 20 ₹16,920 | 6 ₹5,076 |
| 2.00 | M&L for Point wiring for one light controlled by one way switch 6 Amps 240 volts with 1.5 sqmm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed copper wire 1100 volt grade in and including concealed / surface, non metalic rigid PVC medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unsheathed FRLSH copper wire cable 1100 volts grade of size 1.5 sqmm copper conductor as earth wire to common earth dolly including concealed in wall / ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets, fan regulator etc for the following :- Note - Colour code of cable Phase-Red, Neutral- Black and Earth -Green) | 401 | Per Point | 300 ₹1,20,300 | 325 ₹1,30,325 | 380 ₹1,52,380 | 400 ₹1,60,400 | 380 ₹1,52,380 | 320 ₹1,28,320 | 255 ₹1,02,255 Lowest |
| 3.00 | All as per Ser item No 2.00 here in above but One light point controlled by one switch through MS ERW conduit not less than 20 mm dia | 40 | Per Point | 400 ₹16,000 | 320 ₹12,800 | 400 ₹16,000 | 490 ₹19,600 | 370 ₹14,800 | 310 ₹12,400 Lowest | 400 ₹16,000 |
| 4.00 | All as per Ser item No 2.00 here in above but ceiling /exhaust fan point controlled by one switch and regulator | 85 | Per Point | 300 ₹25,500 | 320 ₹27,200 | 300 ₹25,500 | 400 ₹34,000 | 370 ₹31,450 | 310 ₹26,350 | 250 ₹21,250 Lowest |
| 5.00 | All as per Ser item No 2.00 here in above but 3 pin 6 Amps switch socket outlet point on same board. | 75 | Per Point | 80 ₹6,000 Lowest | 185 ₹13,875 | 350 ₹26,250 | 100 ₹7,500 | 170 ₹12,750 | 305 ₹22,875 | 80 ₹6,000 Lowest |
| 6.00 | All as per Ser item No 2.00 here in above but 3 pin 6 Amps switch socket outlet point on independent Board. | 80 | Per point | 300 ₹24,000 | 330 ₹26,400 | 300 ₹24,000 | 450 ₹36,000 | 370 ₹29,600 | 105 ₹8,400 Lowest | 270 ₹21,600 |
| 7.00 | All as per Ser item No 2.00 here in above but 3 pin 5 amps socket out let point on independent board through MS ERW conduit not less than 20mm dia | 50 | Per Point | 500 ₹25,000 | 330 ₹16,500 | 600 ₹30,000 | 520 ₹26,000 | 370 ₹18,500 | 300 ₹15,000 Lowest | 450 ₹22,500 |
| 8.00 | All as per Ser item No 2.00 here in above but light / fan point controlled by two way switch 6 amps 240 volts | 5 | Per Point | 300 ₹1,500 | 335 ₹1,675 | 350 ₹1,750 | 550 ₹2,750 | 370 ₹1,850 | 280 ₹1,400 | 270 ₹1,350 Lowest |
| 9.00 | All as per Ser item No 2.00 here in above but bell point controlled by one bell push switch 6 amps 240 volts | 15 | Per Point | 300 ₹4,500 Lowest | 335 ₹5,025 | 350 ₹5,250 | 390 ₹5,850 | 370 ₹5,550 | 320 ₹4,800 | 300 ₹4,500 Lowest |
| 10.00 | All as per Ser item No 2.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point. | 95 | Per point | 400 ₹38,000 | 435 ₹41,325 | 400 ₹38,000 | 480 ₹45,600 | 450 ₹42,750 | 320 ₹30,400 Lowest | 320 ₹30,400 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Jul 2025, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
REPAIR / REPLACEMENT OF INTERNAL WIRINGS, SOCKETS SWITCHES AT TECHNICAL AREA AND EARTHING PITS, LIGHTENING ARRESTOR, FLAME PROOF FITTINGS AND OTHER MISC WORKS UNDER GE (AF) SRINAGAR
2025_MES_718116_1
GE (AF)/SGR-39/2025-26
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (AF) Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹90,000
Yes
7 Aug 2025
2 Jul 2025
1 Aug 2025
2 Jul 2025
30 Jul 2025
16 Jul 2025
Amount
Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point including fixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces as per existing, complete all as specified and directed.
M&L for Point wiring for one light controlled by one way switch 6 Amps 240 volts with 1.5 sqmm copper conductor FRLSH (multistrand) PVC insulated ISI marked unsheathed copper wire 1100 volt grade in and including concealed / surface, non metalic rigid PVC medium grade ISI marked conduit not less than 19 mm with all fittings & other accessories and also including PVC insulated ISI marked unsheathed FRLSH copper wire cable 1100 volts grade of size 1.5 sqmm copper conductor as earth wire to common earth dolly including concealed in wall / ceiling, modular MS box with modular cover plate with frame suitable for modular switches, sockets, fan regulator etc for the following :- Note - Colour code of cable Phase-Red, Neutral- Black and Earth -Green)
All as per Ser item No 2.00 here in above but One light point controlled by one switch through MS ERW conduit not less than 20 mm dia
All as per Ser item No 2.00 here in above but ceiling /exhaust fan point controlled by one switch and regulator
All as per Ser item No 2.00 here in above but 3 pin 6 Amps switch socket outlet point on same board.
All as per Ser item No 2.00 here in above but 3 pin 6 Amps switch socket outlet point on independent Board.
All as per Ser item No 2.00 here in above but 3 pin 5 amps socket out let point on independent board through MS ERW conduit not less than 20mm dia
All as per Ser item No 2.00 here in above but light / fan point controlled by two way switch 6 amps 240 volts
All as per Ser item No 2.00 here in above but bell point controlled by one bell push switch 6 amps 240 volts
All as per Ser item No 2.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point.
All as per Ser item No 2.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 Amps power point through MS ERW conduit not less than 20mm dia
S&F in repairs piano type one way switch 6 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type two way switch 6 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type one way bell push 6 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type one way switch 16 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type 6 Amp socket suitable for 240 volts, complete all as specified and directed.
S&F in repairs piano type 16 Amp socket suitable for 240 volts, complete all as specified and directed.
S&F in repairs piano type step type fan regulator suitable for 120 watt 250 volts, complete all as specified and directed.
S&F in repairs flame proof rotary type switch with termination box in LM6, 16A single pole 250V, complete all as specified and directed.
S&F in repairs flame proof rotary type switch with termination box in LM6, 25A single pole 250 V, complete all as specified and directed.
S&F in repairs lamp holder / batten holder Polycorbonate type with back plate suitable for batten fitting, complete all as specified and directed.
S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed.
Supply only 10 Watt LED bulb, complete all as specified and directed.
S&F in repairs LED baton fitting 4' length including drivers having energy consumption, 18/20W (White/warm white), 230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs light fitting 9W/ 10W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ, complete all as specified and directed.
S&F in repairs Energy efficient surface mounted 2'X2' grid Ceiling LED fitting 36/40W rated voltage 240 V, 50Hz combination with profiled and flat diffuse, complete all as specified and directed.
S&F in repairs LED baton fitting 2' length including drivers having energy consumption, 10/11W (White/warm white) ,230 V, 50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs building security light LED 25W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc., complete all as specified and directed.
S&F in repairs call bell ding dong type 230 Volts 50 Hz, complete all as specified and directed.
S&F in repairs sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral (VTPN) with MCCB 100 amps ICs=ICu,for 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 8 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified andas directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 12 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified and directed.
S&F in repairs MCB triple pole and neutral ISI marked, C series, working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps, 10 KA breaking capacity, complete all as specified and directed.
S&F MCB of single poles and current carrying capacity 6 to 32 Amp, 240V, 10 KA 'C' curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed.
S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40 Amps 10 KA breaking capacity etc all as specified and directed.
S&F MCB single pole and neutral ISI marked `C' series working on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacity etc all as specified and directed.
S&F in repairs metal clad plug & socket board single pole and neutral enclosure with 3 pin and earth plugs and socket complete with one single pole 20 Amps MCB, 415 Volts, C type, complete all as specified and directed.
Sub main wiring with three runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note : 3 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit.
Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 4.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 4 sqmm copper cable & 1 run of 4 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit.
Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 25 Sqmm 4 core, conforming to IS 1554 Part I / ISI marked, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc. including taking out unserviceable cable, complete all as speccified and directed.
Supply, laying, jointing, testing XLPE insulated PVC sheathed with stranded aluminium conductor heavy duty, size of cable 16 Sqmm 4 core, conforming to IS 1554 Part I / ISI marked, including cable glands , cable lugs etc, to suitable the cable size, cables to be laid in trenches, fixed along the poles bare or through GI pipe laid under floors road etc fixed concealed in walls encased in GI pipe etc. including taking out unserviceable cable, complete all as speccified and directed.
S&F in repairs high bay light LED type 120 Watt, complete all as specified and directed by Engr-in-Charge.
S&F in repairs of flameproof cum waterproof LED bulkhead light fitting of 120 Watt, IP 66 protection of cast aluminium alloy material and heat and impact resistance toughen 'A' clear glass having anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed.
S&F in repairs LED light fitting 2x16 watt flameproof, CMRI certified and recommended for gas/vapour group of IIA & IIB, Zone 1&2 and IP65 protection with die cast aluminium housing with heat resistant toughend glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper condutor cable with suitable size, complete all as specified and directed.
S&F in repairs LED light fitting 20 Watt, flameproof, CMRI certified and recommended for gas/vapour group of IIA & IIB, Zone 1&2 and IP65 protection with die cast aluminium housing with heat resistant toughend glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper condutor cable with suitable size, complete all as specified and directed.
S&F in repairs LED flood light 150 Watt, flameproof, CMRI certified and recommended for gas/vapour group of IIA & IIB, Zone 1&2 and IP65 protection with die cast aluminium housing with heat resistant toughend glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper condutor cable with suitable size, complete all as specified and directed.
S&F in repairs GI bracket 32/40 mm dia suitable for mounting the building security light, complete all as specified and directed.
S&F of LED pillar lights 20 watts of height 2100mm made out of him 1.5mm and base plate of 450X450mm thickness 3.0mm and logo of Indian air force or as directed, complete all as specified and directed.
Disconnecting of any type of earthing strips /earth wire leads of any size, any description and in any position from test point carefully and testing the earth resistance of any type of earthing with the help of digital earth tester of make WACO/or equivalent of suitable capacity maintaining record duly signed by users / JE E/M including carrying out periodical maintinance of joints of earthing strip, by opening, proper cleaning, rubbing the surface by sand paper/ file / tightening / replacement of nuts, bolts & washers of GI / brass and reconnecting of earthing strip/wire lead after test on original position, complete all as specified and directed. NOTE :- (i). The contractor will arrange digital Earth Tester, all T&P & accessories for recording the reading.Testing shall be done as per method shown and described in instruction booklet of manufacturer of digital earth resistance tester. (ii). The record of resistance value of each earthing alongwith date of testing shall be maintained. (iii) Contractor will get the testing of earthing in such a way that each earthing shall be tested & maintenance repeately untill total qty covered on the working days. Hence contractor is advice to quote the rate accordingly. (iv)Testing of earthing shall be paid as one unit per earthing.
M&L for reconditioning of high resistance earthing by watering in the earth pit through watering pipe mixed with common salt minimum 10 Kg for each earthing pit to improve the resistance and filled/dropped in earthing through de-watering pipe as per site condtion, de-watering pipe to be clean by means of appropriate size rod/steel wire, complete all as specified and directed. Note:- The water for this purpose shall be supplied by the deptt at the nearest available source but contractor shall make his own arrangement for drawing water from approved source.
Labour only for repeair /maintenance of of existing tilted /embeded earth pit by digging not exceeding 3 feet deep around earth pit, filling by nearby soil & re-adjusting the earth pit in proper manner, complete all as specified and directed.
Disconnecting and taking up or down existing unserviceable / deshaped, aluminium / GI earth strip or taking down conductors of any size and in any position, stacking properly the serviceable strips for re-use in the work including making good the distrurbed surfaces to match with the existing surfaces, complete all as specified and directed.
S&F in repairs 40mm dia GI tubing, light grade, with all fittings fixed on walls / poles/ in trenches as in earth lead protection pipe, complete all as specified and directed.
S&F in repairs test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal head screws, complete all as specified and directed. Note : - The following items also included and rate to be quoted accordingly. (a) Taking up or down GI socket 40mm / reducer socket 50x 40mm bore including aluminium gutaka. (b) Fixing only GI socket 40mm bore , on vertical pipe post / stand. (c) Old retrieved GI socket obtained in serviceable condition shall be re-used in the work.
M&L in repairs of earth pit of internal size 300mmx300mmx300mm with wall thickness 100mm casting at site with and including PCC base 500x 500x100mm made of PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast 40mm thick RCC cover of (1:2:4) type B-1 (using 20mm graded crushed stone aggregate), rainforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle etc. including removal of old broken unserviceable earth pit from site, complete all as specified and directed. Note : - Excavation, returning filling and removal of soil deemed included in quoted rate.
S&F in repairs earth pit cover, pre-cast RCC, 1:2:4, type B-1 (using 20mm graded crushed stone aggregate), 320mm x 320mm x 40mm thick, cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle with and including necessary form work complete all as specified and directed. Note : - Excavation, returning filling and removal of soil deemed included in quoted rate.
S&F in repairs GI funnel with wire mesh for watering the earth pit made to shape and size with using PGI sheet minimum 1.0mm thick and fixed in position, complete all as specified and directed.
S&F in repairs marker fabricated with 14 gauge MS sheet of size 300mmx180mm rectangular with 20 mm square hollow bar 60 cm long duly painted of colour as directed for writing ER value, date of testing and due date for testing, Earth pit No etc., complete all as specified and directed.
M&L for painting one coat of synthetic enamel paint on earth pit and cover complete job with approved colour, complete all as specified and directed.
S&F in repairs HDPE DWC flexible pipe of Size 40mm external & 33 mm internal dia (ISI marked) including required clamps/couplers to be fix at 1.5 m interval on wall to fix the pipe properly and smooth suitable for insulation & protection of GI strip of any size, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
All as per Ser Item No 61.00 here in above but earth strip 25 x 4 mm (main earthing lead).
All as per Ser Item No 61.00 here in above but earth wire 4 mm dia (main earthing wire).
M&L for copper earthing complete with 600mm × 600mm × 3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 3 connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, complete all as specified and directed. NOTE : (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall be measured and paid for separately under appropriate item of Schedule `A’/BOQ. (ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted.
M&L in repair for chemical earthing complete with copper earth plate electrode 900mmx600mmx5mm thick placed horizontally and buried directly in ground (earth pit not less than 4.75 mtr deep below ground level) with top edge of the plate not less than 4.00 mtr below normal ground connected with coppert strip 32x6mm by means of brazing, providing and filling of charcoal dust and common salt in 150mm alternate layer at least 150mm around and bottom edge of earth plate, providing and filling 500mm layer of magnisium suphate from top edge of earth plate, watering pipe of 50mm bore galvanised light grade with funnel and 50mm bore galvanised iron light grade for earth strip protection, including all excavation/earth work in any type of soil, PCC pit (size as per electrical plate No3 SSR part-1) in PCC 1:2:4 type B-1 and RCC 1:2:4 type B-1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 KG/Sqm), including testing on completion, complete all as specified and directed.
S&F in repairs 40mm dia aluminium gutka having internal thread of 12mm dia and external thread of 40mm dia and fixed on GI socket with air termination rod 300 / 1200mm long of suitable size, complete all as specified and directed.
S&F in repairs 4mm dia galvanised iron or steel wire earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and directed.
S&F in repairs 25x4mm galvanised iron strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and directed.
S&F in repairs 32 x 6mm copper strip earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and directed.
S&F in repairs 20 x 3mm copper strip earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., complete all as specified and directed.
S&F in repairs 25 x 3mm aluminium strip with apoxy insulator earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of suitable size of fixing on walls/floors, complete all as specified and directed.
S&F in repairs air termination single pointed aluminium rod 12 mm dia and 300mm long lightening arrestor, screwed for easy fitment and fixing with base plate with 10mm holes on four corners for necessary fixing arrangement on top of PCC block (15cmx15cmx20cm), complete all as specified and directed.
S&F in repairs air termination single pointed copper rod 12 mm dia and 300mm long lightening arrestor, screwed for easy fitment and fixing with base plate with 10mm holes on four corners for necessary fixing arrangement on top of PCC block (15cmx15cmx20cm) ,complete all as specified and directed.
S&F in repairs 25 mm size epoxy type insulator suitable for fixing earthing strip of all sizes including screw etc., complete all as specified and directed.
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismantling / taking down items) worth Rs 1,34,945.00 during AOC. (Note :- Tenderers shall not quote for this Schedule)
M/S NEW FAROOQ TRADERS (BID ID -3368819)
M/S RATHER CONSTRUCTION CO (BID ID -3376687)
M/s Jaipal Associates (BID ID -3368882)
M/S NAZIR CONSTRUCTION (BID ID -3368630)
M/s GHULAM NABI HAJAM (BID ID -3368900)
M/S ZAHOOR ENTERPRISES (BID ID -3368628)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .