Capital (Works)
18 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
With the submission of the certificate/affidavit as mentioned, the practice of verification of tenderer's documents by the Railway dispensed with. Instruction for bidders, in this regards are:
Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification of lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway thereunder.
In case of any wrong information submitted by tenderer, the contract shall be terminated, Earnest Money Deposit (EMD),Performance Guarantee (PG) and Security Deposit (SD) of contract forfeited and agency barred for doing business on entire Indian Railways for 5 (five) years.
With such a system of self-certification of credentials, tender finalization should also be speeded up. The Tenderer(s) shall keep the offer open for a minimum period of 60 days (in case of two packet system of tendering 90days) from the date of closing of the Tender.
143 conditions · 1 needing a document upload
Any payment required for E-Tendering is accepted through Net Banking or Payment Gateway only.
Credentials in support of fulfillment of eligibility criteria ( Without these documents the offer is liable to be rejected) as per details stipulated in Tender documents. Each and every pages of the supporting documents should be signed with proper seal and date.
Details of technical personnel with qualification and experience employed by the firm.
Details of special equipments , tools and plants, machinery etc available with the firm for execution of contract works.
If working through contract labour , the contractor must resgister with Labour Commissioner and necessary license to be submitted with tender or to be produced before signing of contract agreement.
Partnership deed, if any, constitution of the firm and copies of power of attorney and other connected legal documents to be submitted.
Submission of requisite information for Financial Eligibility criteria as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
All required documents duly attested as per Para 14.0 of IRGCC must be submitted.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Execution of Signaling & Telecommunication work in connection with: (1) Through Turn out renewal 86 Sets [BMY-76 Set (CS+CMS) and Durg-DRZ - 10 Sets (TWS+WCMS)], (2) Through Rail Renewal (Primary) - 64.595 Kms.
SNT-R-2026-01~SECR
SNT-R-2026-01
Open
Works - General
12 Months
Raipur, Chhattisgarh
₹0
₹6.3 L
13 Feb 2026
17 Jan 2026
30 Jan 2026
203 items across 4 schedules · ₹9,68,82,702.63 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Excavation of trench Depth 1.0 Mtr. & width 0.3 Mtr and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil in all soils including soft rocky area. | Kilometre | 20.00 | 76,590 | 15,31,800 |
| 2 | Excavation of trench in all kinds of soils including softrockyarea and clearing of roots of trees, bushes, rocks,ballastetc., to a depth of 1 Mtr. & width 0.3M for track/puccaroad/Platform crossing/ level crossing and any other placeasadvised by the Engineer-incharge includingsupply,transportation and laying of RCC pipe with collars(forjointing pipe) 150mm nominal dia to Spec.No:IS-458intrench and drawing of Signalling/ Power/ Quadcablesthrough pipe including back filling and ramming aftercablelaying as specified in Technical Circular No.2 of1988issued by CSTE/S.E.Rly. This includes repairingandplastering of platform/pucca road after cable laying.RCCpipe shall be inspected by the Rep.of Sr. DSTE /Rbeforelaying. NOTE:-Power cable,signalling cable, Quadcable asmentioned above,where required shall be laid in thesame trench as signalling cable but in a separate pipe. | Metre | 350.00 | 1,008.8 | 3,53,080 |
| 3 | Laying and Fixing of galvanised iron pipe (GI Pipe) withthreadedcollars (for jointing pipe) of 80 mm nominal diaSpec.No.IS-1239medium grade, on bridges, culverts, drainsincluding supply andtransportation of GI pipes and all othermaterials required forfixing the pipe to Drg.No.Con/SK/T/2and drawing ofSignal/Power/Quad cables inside the pipewith masonary worksover the entire length of the bridge andat entry and exit of theculvert and curing for 72 hrs, drillingof holes on the pipe at 10 cmapart to be clamped 2 Mtrsapart on culvert, for the Signalling,quad, power cable. | Metre | 500.00 | 761 | 3,80,500 |
| 4 | Excavation of trench and clearing of roots of trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil in Hard rocky area includingconcreting. Chase cuttingand smoothening of inside surfaceof sizes 0.08 m deep and 0.17m width at platform andcemented floor area. | Metre | 300.00 | 115 | 34,500 |
| 5 | Excavation of trenches including clearing of roots oftreesetc. in hard rocky soil by chiseling up to a depth of0.5m to0.8 Mtr. At the bottom, supply and placing half roundRCCpipe on sieved soil of 30 mm over cable andconcretingthroughout the lenght upto a layerof 75 mmapproximately(1:2:4) , as advised by the site engineer &Guide lines onSignalling cable Laying issued by SignalDirectorateResearch,Design & Standards organisationMinistry ofRailways Manak Nagar Lucknow- 226011,Version-1.0,Effective from dt 31.10.2011 . Thendigging and backfillingthe trench by digging and carryingearth from a lead ofmaximum 30Mtrs and then ramming thesoil after cablelaying. This includes supply of half round RCCpipe. | Metre | 3100.00 | 372 | 11,53,200 |
| 6 | Excavation of trench and clearing of roots of trees, bushes,ballastand reconditioning etc., including bailing out waterand disposal ofextra soil. Track crossing, Road Crossing bypushing method(HDD method) at culverts/ track / puccaroad crossing at a depthnot less than 1 meter with referenceto bottom of rail/road surfaceincluding supply of GI pipe with76 mm dia, Spec. No. - 1239medium grade (for the length ofpushing more than 05 meters). | Metre | 850.00 | 2,246 | 19,09,100 |
| 7 | Fixing of concrete cable route marker at 30-40 meter andatdiversion point including supply & transportation ofcableroute marker at site. Detail size & fixing of cableroute marker should be followed as per drawing no.SDO/Cablelaying/020. | Numbers | 180.00 | 415 | 74,700 |
| 8 | Laying of Signalling Cable/Power/Quad cable / PIJF cableinthe excavated trench toDrg.No:CON/SK/T/5.Transportation,supply of 'U' clampsand anchoring of cable at every 10 Mtrswith 'U' clamp toDrg.No:CSTE/C/Cable/81 including backfilling withexcavated earth and ramming of trenches aftercablelaying. Note: The contractor has to conduct detailedsitesurvey of the cable route, prepare a plan to get approvalofthe Railway, putting white lime powder markingbeforeexcavation of earth under supervision ofrailways authorised representative. | Kilometre | 69.00 | 16,740 | 11,55,060 |
| 9 | The excavation of pit, casting of concrete foundationincludingsurrounding earthwork along the foundation,erection, installationand wiring of steel appartus case, fixingof terninals, fuse blocks,signal transformer, currenttransformer, filament switching unit,track battery chargers,adjustable/fixed resistances, choke coils,Fuses, Relays, Etype locks , termination of cables, cableinsertion, wiring todraw 110V AC therefore in the new apparatuscase asrequired, testing, commissioning includingsubsequentalterations (if required), bunching of cables,earthing of cable,armours etc. Painting of the apparatuscase inside and outsideafter clearing the surface thoroughlyand first coating of anti -corrosive paint and subsequent twocoatings of Alluminium paintoutside and Red Oxide insideand lettering. 18 mm Hylum sheetfor location box shelf and12 mm for cable termination in locationbox.Steel appartus case (Large) to Drg.No. CON/SK/T/8 with 4Nos. of foundation bolts 20mm x 460mm to Drg.No. SA- 112 A/M or latest. | Numbers | 25.00 | 17,067 | 4,26,675 |
| 10 | Alteration/ Modifications in the existing location boxes, fixingofequipments, cable insertion, termination, wiring, testing&commissioning, two coat painting, lettering to suit thecircuits asper approved wiring diagrams. This includes fillingwith sand and plastering the same. | Numbers | 58.00 | 2,548 | 1,47,784 |
| 11 | Transportation & Execution of following kinds of joints on Quad Cable using thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing. (b) straight through joint on Quad cable/10-20-50 pairs PIJF Cable. | Numbers | 14.00 | 1,385 | 19,390 |
| 12 | Installation, testing and commissioning of Permanent andMaintenance Free Earth pits.Installation charges : Earthpit(1 Set) It includes: (1) Civil works related to earth pitdigging, PMF earth pit installation,,backfilling and chamber making, (2) Materials for chamber including Chamber Cover. | Numbers | 50.00 | 5,882 | 2,94,100 |
| 13 | Excavation of earth pit, transportation, placing and fixing ofearth electrode with construction of cement encloser toDrg.No.CON/SK/T/9 and CON/SK/T/9A and drawal of GIwire wrapped on MS strip (35 x 6 mm) from earth electrodeto all signalling equipments, including fixing and soldering oflugs at both end of the wire. | Each | 180.00 | 1,941 | 3,49,380 |
| 14 | Transportation, installation of Point machine Junction Box along with lead wires for replacement / lifting as advised by Railway representative. All materials like Point JB, angles, lead wires, channel pins, ARA terminals as may be required shall be supplied by the Railways. The nut & bolts & washer shall be supplied by contractor. | Numbers | 90.00 | 617 | 55,530 |
| 15 | Alteration of existing Q-series/Composite Relay Racks and cable termination racks. | Numbers | 12.00 | 19,785 | 2,37,420 |
| 16 | Execution to be made by the contractor in Autocad as perfollowing :-1. SECRailwayPractice in conformity with GR,SR& SEM. 2 . As per latest typicalcircuit diagram andguidelinesof SEC railway. Design &Preparation ofCircuits and drawingsDesign,Preparation & checking of documents and Circuit diagram and drawings(a) Design and development of Circuit Diagram in size B(A3) as per SEM sheet including contact analysis. | Sheet | 120.00 | 1,004 | 1,20,480 |
| 17 | Installation (including over hauling) of Electric pointmachines on MS plate fixed on wooden/PSC sleeperscomplete with crank handle key Interlocking arrangementas per the drawing approved by Railways, junction boxes(as suggested by the railway) with 1 ½'' dia G.I.pipe/HDPEpipe of required length up to point machine, groundconnections, including smithy works involved, insulation ofMS plate on which the point machine is to be fixed from thegauge tie plate involving revetting/welding of angle, cleats,termination of cables, wiring, preliminary adjustment foroperation of point by crank handle and subsequent finaladjustment, painting and lettering as required, testing andcommissioning of the same. | Each | 150.00 | 12,859 | 19,28,850 |
| 18 | Dismantling of point machine and stacking as per instruction of Rep.of Sr.DSTE/R. | Numbers | 90.00 | 603 | 54,270 |
| 19 | Charging and installation of secondary cell 2V-80AH/120AH/200AH (lead acid type) , and preparation of electrolyte for lead acid cells. If power is not available at site of work, charging may be done at nearby location as per convenience of the Railway. Initial Charging to be done in presence of Rlys representative from executive agency as well as maintenance org,with uninterrupted supply. | Each | 830.00 | 310 | 2,57,300 |
| 20 | Transportation of released materials from site to the stores ofSSE(Sig/Tele)/R or BIA or BYT or DRZ or to GSD. This includesloading, unloading and stacking of materials. | Per Trip | 14.00 | 3,661.1 | 51,255.4 |
| 21 | Dismantling & Installation and fixing of Ground connectionof point machine for replacement / repairing of existingGround connection as advised by Rep.of Sr.DSTE/R. ItIncludes smithy works involved, drilling of holes in TongueRail / Stock Rail LH or RH or both site asper siterequirement if required, preliminary adjustment foroperation of point by crank handle and subsequent final adjustment, painting and lettering as required, testing and commissioning of the same. ( any type of IRS Point machine) | Numbers | 200.00 | 4,899.6 | 9,79,920 |
| 22 | Transportation, installation of Track Lead Junction Boxalong with lead wires for replacement / lifting as advised byRep.of Sr.DSTE/R. All materials like TLJB, angles, leadwires, channel pins, ARA terminals as may be requiredshall be supplied by the Railways. The nut & bolts & washershall be supplied by contractor. | Numbers | 150.00 | 271.6 | 40,740 |
| 23 | Strengthening of foundation of full/half location boxes, by carrying out the earth work around the foundation, ramming of the earth carrying out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. All the material for masonry work to be supplied by the contractor. | Numbers | 15.00 | 5,405.1 | 81,076.5 |
| 24 | Transportation, installation, testing & commissioning of fuse indication cum monitoring and automatic changeover system. | Numbers | 3.00 | 9,469 | 28,407 |
| 25 | Cement Concrete of proportion 1:3:6 with graded aggregate of size 25mm. and below. | cum | 15.00 | 2,943 | 44,145 |
| 26 | Deployment of Prokline/ Hydra operation at site forexposingthe burried cables or relocation the Location Box/SignalPost with foundation or shifting of heavy materials as per the advice of Railway site engineer. | Hour | 200.00 | 603 | 1,20,600 |
| 27 | Physical tracing and opening/locating of existing workingcables by precession digging for diversion of cables inconnection with cable clearance for engineering earth workwithout interfering the circuits as per the advice of Railwaysite engineer. | Metre | 870.00 | 241 | 2,09,670 |
| 28 | Painting of full size location box with alluminium paint andnomenclature as of location with black/Yellow paint asadvised by Railway engineer. This includes supply ofrequired quantity of paint for lettering & background paintof complete location box (Make: Burger/Asian) for thiswork & letter size should be as per instructions of site-incharge.This also includes cleaning of dust, mud, rust etc,rubbing with sand paper, wiping out of old letters written on the concerned equipment. Equipments shall be painted in accordance with signal engineering manual.The colours to be used are as given in SEM. | Numbers | 530.00 | 396.73 | 2,10,266.9 |
| 29 | Painting with nomenclature of signal post in Alluminiumand black paint as advised by Railway engineer. (IncludingCLS, unit, ladder, base & post). This includes supply ofrequired quantity of paint for lettering & background paintof complete signal post, base, ladder (Make:Burger/Asian) for this work & letter size should be as perinstructions of site-incharge. This also includes wiping outof old letters written on the concerned equipment.Equipments shall be painted in accordance with signal engineering manual. The colours to be usedare as given in SEM. | Numbers | 370.00 | 844.72 | 3,12,546.4 |
| 30 | Installation of signal posts for Multiple Aspect Colour LightSignals complete with signal units, bases, LED unit, fixingand wiring of current transformers of LED units, ladders &other fittings, excavation of pit, casting of cement concretefoundations with necessary water outlets, erection andfixing of complete fittings of the signal/signal post withnecessary earthed screen protection arrangement,including drawing of cable through signal posts,termination of cables, wiring, testing and commissioning,two coat painting and lettering, supply and fixing of speedboards if required for the following:- NOTE:- Thefoundation for Multiple Aspect Colour Light Signal Postdrg. No. Con/SK/T/12 and and the foundation bolts shallbe of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M andbolts for each foundation for above shall be of size 20 mmx 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) withtwo nuts and two washers each per bolt. (a) 3 ASPECT/4ASPECT | Numbers | 10.00 | 19,551 | 1,95,510 |
| 31 | Installation of signal posts for Multiple Aspect Colour Light Signals complete with signal units, bases, LED unit, fixing and wiring of current transformers of LED units, ladders &other fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M and bolts for each foundation for above shall be of size 20 mmx 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. (b) 2 ASPECT | Numbers | 2.00 | 17,378 | 34,756 |
| 32 | Fixing of calling-on signals/dependent shunt signals with enameled markers including drawing of cable through the signal post, termination of cables, wiring, fixing of calling- on/dependent shunt signal legend board, LED, two coat painting and lettering, testing and commissioning as required. | Numbers | 10.00 | 4,629 | 46,290 |
| 33 | Installation, testing and commissioning of Position Light shunt signal (Independent), posts complete with lamps/LED lamps, LED units, Bases and other fittings, excavation of pit, casting of cement concrete foundation, fixing of complete fittings of signal, LED lamps, current regulator including foundation bolts, washers, nuts, termination of cables, wiring, painting and lettering as required. NOTE:- The foundation for position light shunt signal Drg. No. Con/SK/T/13 and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA-110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. Note: Payment can be released in a part for the above said works after completion of- (i) Foundation- 30%, (ii) Erection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate. | Numbers | 4.00 | 3,856 | 15,424 |
| 34 | Supply and provision of Perimetric/Ring Earth with Maintenance Free Earth arrangement as per RDSO TAN No. STS/E/TAN/3006 Ver.3.1 dated 25.06.2025 or Latest. Supply of all requites material as per latest RDSO Guide Line. Earthing shall comply all guidelines (arrangement, parameters, pre-commissioning check list, warranty of 60 months etc.) specified in RDSO TAN no. STS/E/TAN/3006 Ver.3.1 dated 25.06.2025. NOTE: (1) The overall Earth resistance value for the earth connected with MEEB shall be less than 1 ohm, (2) The earth pits shall be interlinked using a 25 x 2 mm copper tape /Solid copper round conductor of 8mm dia/GI tape of 50X6mm (for theft prone areas only) with proper exothermic welding, (3) The interconnecting conductor shall be buried at a depth of not less than 500 mm below the ground level. This conductor shall also be covered with approximately 30 kg of earth enhancement compound for every 3 meters of its length, (4) PVC insulated multi-strand single core 4 X 35 sq. mm copper cable or 2nos of 25 X 2 mm copper tape to be used for connecting MEEB to nearest earth electrode, (5) Provision of Bonding Ring Conductor (BRC)of 25 x 2 mm copper tape shall be provided at Relay Room & IPS Room and all equipments & racks should be connected to BRC as per RDSO TAN, (6) All the required Materials for providing Earthing & Bonding as per schedule will be supplied by Contractor and from RDSO approved firm only. Materials to be inspected by RDSO. | Station | 2.00 | 2,46,283.63 | 4,92,567.26 |
| 35 | Supply of Unskilled labour for immediate restoration of normal traffic by jointing Signalling/Telecom/Power cables of damaged during excavation of earth work of engineering department or for shifting, stacking of stores materials. Unskilled staff will remain available in working hours. | Man- Days | 200.00 | 266 | 53,200 |
| 36 | Supply of active lightening arrester of Class A for building protection as per NBC 2016. Non resettable type counter shall also be supplied to count the number of lightening occurrences. It also includes supply of 50 sq mm copperbonded steel conductor for connecting Class A device to the earth pit. This include installation, testing and commissioning of Class A device on the top of the building. This device shall be installed at suitable height on the roof of the building using a GI mast as per instructions of Railway engineer at Site. The device shall be connected to earth pit using a 50 sq mm copper-bonded steel conductor. This shall be run firmly only the site of the mast with the help of spacers. It shall also be ensured that the down conductor shall not touch the building throughout. the down conductor shall be connected to the earth electrode using exothermic welding. A counter shall be installed at appropriate space to count the number of occurrence. All the material & accessories like spacers, welding material etc. required for installation shall be supplied by the contractor. Isolated Spark Gap (ISG) of rating 100 KA shall be used to interconnect lightning arrestor earth pit to signal ring earth as per RDSO TAN No. STS/E/TAN/3006 Ver.3.1 dated 25.06.2025 or Latest. Materials to be inspected by RDSO. | Numbers | 1.00 | 66,992.1 | 66,992.1 |
| 37 | Provision of cement concrete enclosure for earth electrodes as per DRG. NO. S&T/C- 36(NKG). This includes supply of all materials by the contractor duly inspected by representative of SrDSTE/R. | Numbers | 100.00 | 481.35 | 48,135 |
| 38 | Supply & installation of Fencing (Picket Type Tie Bar fencing) work around S&T apparatus case or building/office etc. as per instruction of Railway representative. | Kg | 2000.00 | 199.05 | 3,98,100 |
| 39 | Transportation, installation, fixing &commissioning of MS Flat on existing conventional earth. This includes cutting, making holes, welding etc. of MS flat as per site requirement. This also includes supply of SS nut& bolt as per requirement. Note: Unit Numbers stands for per earth. | Numbers | 350.00 | 1,217.7 | 4,26,195 |
| 40 | Installation testing and commissioning of Distilled water plant/Demineralized plant as per instruction of railway representative. | Numbers | 2.00 | 3,309 | 6,618 |
| Schedule total | ₹1,43,45,533.56 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .