Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Performance security Rs. 1,60,500.00 shall be submitted before 28 days from the acceptance of the contract as per Condition 19 of IAFW2249 otherwise necessary action will be taken against your firm | |
| 2 | L2₹38.4 L+₹5.3 L (16.1%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹41.2 L+₹8.1 L (24.3%)Rejected-Finance 301 TULSI TOWER KHADAKPADA KALYAN THANE MAHARASHTRA 421301 | THANE | MAHARASHTRA | 421301 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹41.3 L+₹8.2 L (24.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹41.4 L+₹8.3 L (25.1%)Rejected-Finance 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | M/S MALHOTRA ENGINEERING WORKS L4 | M/S R S Traders L7 | K R GUPTA AND SONS L8 | M/S VIJAY SINGH L1 | Diamond Electric Co. L3 | Krishna Enterprises L6 | M/S SHIV BALLABH MISHRA L5 | SUNILENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Fabrication, supply, installation, testing and commissioning CPRI approved electrical cubical control panel board (in replacement) factory assembled made outdoor type feeder pilar box double door type wheather and vermin proof fabricated of 3.15 mm CRCA MS Sheet of suitable size, 3 phase 4 wire 415 V AC 50Hz complete duly painted with powder coating complete with locking arrangement, earthing termimal with suitable rating copper strips for incoming/outgoing MCCB's including and mounting measuring instrument such as Volt meter, Ammeter, selector switch, CTs phase indicator lamp with holder, toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands and end termination including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded onall four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed by the Engr-in-Charge (Feeder piller box shall be consisting the following:-) | 8 | Each | 1,10,000 ₹8,80,000 | 1,30,000 ₹10,40,000 | 1,01,000 ₹8,08,000 | 97,000 ₹7,76,000 | 1,05,000 ₹8,40,000 | 1,13,000 ₹9,04,000 | 90,000 ₹7,20,000 Lowest | 1,02,000 ₹8,16,000 |
| 1.01(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 400 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. | |||||||||||
| 1.02(b) Phase indication lamp, LED type (set of 3) -1 Set | |||||||||||
| 1.03(c) Ammeter anolog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each phase. | |||||||||||
| 1.04(d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B. | |||||||||||
| 1.05(e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4) cement sand etc complete all as specified and directed. | |||||||||||
| 1.06(f) Incoming : MCCB 4 Pole 250 Amp 415 volt thermal adjustable, type with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. | |||||||||||
| 1.07(g) Outgoing: MCCB 4 Pole 125 Amp 415 volt thermal adjustable, type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. | |||||||||||
| 1.08(h) MCCB 4 Pole 63 Amp 415 volt thermal adjustable, type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. | |||||||||||
| 2.00 | Supply, fixing ( in replacement ), connecting to electrical system & testing of Busbar panel board, cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs, duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set. (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase.
(d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B. (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm graded crushed stone aggregate & plastering with (1:4) cement sand etc complete all as specified and directed. | 4 | Each Job | 32,500 ₹1,30,000 | 22,000 ₹88,000 | 41,000 ₹1,64,000 | 17,400 ₹69,600 | 37,200 ₹1,48,800 | 15,000 ₹60,000 Lowest | 37,000 ₹1,48,000 | 26,000 ₹1,04,000 |
Tender Value
₹49.8 L
EMD Value
₹99,700
Closing Date
5 Jul 2025, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIRS/ REPLACEMENT OF UNSERVICEABLE LT PANELS ALONG WITH CONNECTED ITEMS AT NEW PROJECT, MAP AND PROVISION OF HIGH SPEED PEDESTAL FANS AND WALL MOUNTED FAN AT CERTAIN LOCATION OF HQ CAC AT AF STN BAMRAULI
2025_MES_714840_1
8974/E8
Open Tender
Civil Works - Others
Works
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹99,700
Yes
2 Sept 2025
16 Jun 2025
7 Jul 2025
16 Jun 2025
5 Jul 2025
30 Jun 2025
Amount
(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 400 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set.
(b) Phase indication lamp, LED type (set of 3) -1 Set
(c) Ammeter anolog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each phase.
(d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B.
(e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4) cement sand etc complete all as specified and directed.
(f) Incoming : MCCB 4 Pole 250 Amp 415 volt thermal adjustable, type with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos.
(g) Outgoing: MCCB 4 Pole 125 Amp 415 volt thermal adjustable, type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos.
(h) MCCB 4 Pole 63 Amp 415 volt thermal adjustable, type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos.
Supply, fixing ( in replacement ), connecting to electrical system & testing of Busbar panel board, cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900x600x500mm and supported with 4 Nos MS Angle legs, duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 300 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set. (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase. (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B. (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm graded crushed stone aggregate & plastering with (1:4) cement sand etc complete all as specified and directed.
Supply, fixing & testing of LT distribution panel board (in replacement), made out of 2 mm thick MS sheet of size not less than 600x450x200mm duly painted with two coats of synthetic enamelled paint over one coat of red oxide primer wall mounted/semi-grouted in wall with locking arrangement, double door type, compartmentalised and provision for tapping incoming & outgoing electric connections with suitable size of lugs, glands, one MCCB will be mounted on proper din railes and comprising of the followings :- (a) Aluminium busbar chamber TPN of 200 amps rating (set of 4 strips). (b) Phase indication lamp-set of 3. (c) MCCB 4 pole 415 Volts, 50 Hz, 100 amps rating, 25 KA breaking capacity - 01 No (Incomming). (d) MCB TPN 63 A -2 No and MCB SPN 32 A -3Nos as out going cotrol.
S&F in replacement of following items in the existing out door/ indoor LT panels and connection with using aluminum lugs/ferruls incl disconnection & connection of cable and making necessary alteration in panel/door using welding wk and cutting as required for proper fixing & connection complete all as specified and directed as below :-
(a) MCCB 4 pole 125 amps rating, 16 KA breaking capacity with spreader at both side.
(b) MCCB 4 pole 150/160 amps rating, 36 KA breaking capacity with spreader at both side.
(c) MCCB 4 pole 200 amps rating, 36 KA breaking capacity with spreader at both side.
(d) MCCB 4 pole 250 amps rating, 36 KA breaking capacity with spreader at both side.
(e) MCCB 4 Pole 100 amps rating, 16 KA breaking capacity, 415 Volt.
(f) MCB TPN 100 amps, 'C' series, 415 volt.
(j) CTs of existing ratio and capacity fixed in LT panels and connect with ammeter.
(k) Microprocessor based MCCB 4pole 250 amps rating, 36 KA breaking capacity with spreader at both side.
(l) Microprocessor based MCCB 400 amps rating, 36 KA breaking capacity with spreader at both side.
(m) Indicator lamp, LED type incl 1.5 sqmm wire for connection to desired point of bus bar.
(n) MCB TPN 100 amps, 'C' series, 415 volt.
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core aid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 Core aid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Supply, laying, jointing and testing in replacement of underground LT cable XLPE insulated, screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core laid in trenches/ducts/along poles/ through pipe under road etc complete all as specified and directed by Engr-in-Charge
Excavation in trenches not exceding 1.5m wide and noe exceding 1.0 sqm on plan and not exceding 1.5m depth and getting out soft soil complete all as specified and directed
Returing filling in including spreading leveling watering and well ramming in layer not exceding 25 cm as in soil complete all as specified and dirceted
Removing excavated material not exceding 50 m and deposting where directed at a level not exceding 1.5 m above the starting point complete all as specified and directed
Supply and laying sand dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and directed (Note - Only punned thickness will be measured for payment purpose)
Supply and laying bricks (old size) for cable protection by using common burnt clay building bricks, sub-class 'B' of size 230x11.5x7.5 cm having crushing strength not less than 75 Kg/sqcm, laid dry flat across length of the cable with width of the trenches equal to length of bricks, all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 80 mm light grade for protection of cable complete all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 50 mm light grade for protection of cable complete all as specified and directed
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 40 mm light grade for protection of cable complete all as specified and directed
M&L for boring holes (manually) under road, hard standing without damaging surface for 80/50/40 mm dia GI pipe etc complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised strip 32x6mm as earth lead by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade,40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection complete all as specified and testing on completion.
M&L for heavy duty air circulator pedestal fan 24 inch (size 600mm), speed 1440 RPM, 180 watt, No of 3 blades metal body one year warranty complete all as specified and directed by Engr-in-Charge.
S&F wall mounted fan 400mm sweep, 230 volts, 50Hz 1420 RPM with 90 degree oscillation and having speed control by two pull cord system complete all as specified and directed.
M&L for providing flexible copper cable 3 core, PVC insulated of 2.5 sqmm, 30m in length and connected with 15 Amp suitch, socket combination alongwith PVC Box & Plug Top including making connections, complete all as specified & directed by Engr-in-Charge.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
SUNILENTERPRISES (BID ID -3346207)
Diamond Electric Co. (BID ID -3348091)
M/S MALHOTRA ENGINEERING WORKS (BID ID -3346511)
M/S SHIV BALLABH MISHRA (BID ID -3347762)
Krishna Enterprises (BID ID -3348370)
M/S R S Traders (BID ID -3347584)
K R GUPTA AND SONS (BID ID -3347692)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .