Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BID | |
| 2 | L2₹7.0 L+₹24,340 (3.60%)Rejected-Finance | L2 | Rejected-Finance L1 BID HIGHER THAN | |
| 3 | L3₹7.2 L+₹42,720 (6.32%)Rejected-Finance 51 1 FULBAGAN ROAD BAGHAJATIN KOLKATA 700086 WEST BENGAL | KOLKATA | WEST BENGAL | 700086 | L3 | Rejected-Finance L1 BID HIGHER THAN | |
| 4 | L4₹7.3 L+₹55,692 (8.24%)Rejected-Finance 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L4 | Rejected-Finance L1 BID HIGHER THAN |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
11 Dec 2021, 6:00 pmClosed
GE
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR MAINTENANCE OF SEWAGE LINE AREA DRAIN ROOF TREATMENT WATER STORAGE TANK AND MISC SERVICES TO P128 JAMUNA BLDG AT BM CAMP UNDER GE I CG N KOLKATA
2021_MES_468158_3
8945/E8
Open Tender
Civil Works
Item Rate
180 days
GE I CG AND N KOLKATA
AS PER NIT
10 documents required · 10 mandatory
₹500
GE I CG N KOLKATA
₹14,000
Yes
29 Dec 2021
20 Nov 2021
18 Dec 2021
20 Nov 2021
11 Dec 2021
27 Nov 2021
Amount
Cleaning of drain pipe (SGSW/hume pipe) upto 150 mm dia by rodding from manholes and well flushing with water after cleaning the same all as directed and including disposing off the deposited sludge inside pipes from manholes to a distance n. exc. 200 mtr burried under ground (minimum 30 cm below ground level) including necessary excavating of pits and returning filling in sprinkling of bleaching powder and dressing of surplus soil around slope if any complete all as specified & directed.
Cleaning and removing all debris/vegetation from roof surfaces of any height and cleaning the mouth of rain water pipe and removal of material outside MOD land complete all as specified & directed.
Taking up deposited silt / earth from existing brick drain and culverts to clean the water ways and removing to a distance not exc. 50 m complete all as specified and directed
Cleaning of RCC roof tank of capacity more than 25000 ltrs by taking down existing inlet and outlet pipes and cleaning, rubbing down and removing all scales and dirt, mud and any other foreign materials etc from inside complete incl writing letter on RCC tank as TANK CLEANED ON ____ (Dt, Month and year) complete all as specified and as directed.
S&F 50mm thik precast RCPC cover slab of 2MT load bearing capacity with embosing RCPC 2MT set in collers complete all as specified and as directed including taking out old one.
Scrapping worn out tarfelt and bituminous compound of water proofing treatment over RCC roof by using wire brush and blow lamps including dismantling cracked/broken PCC (if required sweeping, cleaning washing down to remove dust etc and removing rubbish debris etc to a distance n.exc 50 m from the site (s) complete all as specified & directed.
M&L water proofing treatment on cleaned RCC roof comprising with the following operation and as specified here-in-below :- (a) 20 mm thick (av. mimimum thickness) plastering in cement mortar 1:3 with integral WPC, finishing the plastered surfaces even and smooth over cleaned RCC roof. The plastered surface shall be cured properly for ten days by ponding of water over roof. (b) Applying bitumen primer over the plastered surface @ 0.40 Ltr / Sqm by the same membrane manufacturer of density at 25°C, 0.87 to 0.89 kg / Liter and viscosity 70-160 cps. (c) Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 3.6 kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt make as approved over the primer coat. Membrane shall be laid using butane torch and sealing all joints etc all as per Para 11.44.5 of SSR Part I. (d) Applying one coat of Aluminium paint @ 0.1 ltr per Sqm over APP based polymetric membrane complete all as per manufacturer's instruction.
Taking down loose/damaged concrete and cement plaster of any description from columns, facias, fins, chajjas, beams, walls, roof slabs and similar items etc. by hammering wooden mallets carefully, chipping of old concrete surfaces including cutting of corroded reinforcement as required with necessary scaffolding and protection upto any floor and removal of debris to a distance n exc. 100 m from the starting point complete all as specified and as directed.
M&L for providing RCC 1:1.5:3 using 12.5mm graded crushed stone aggregate mixed with plasticiser(Conplast SP-337) as per manufacturer's instruction as in lintels, beams, columns, chajja etc. with necessary scaffolding and protection as required at site up to 4th story complete all as specified and as directed.
M&L for providing RCC 1:1.5:3 using 12.5mm graded crushed stone aggregate mixed with plasticiser(Conplast SP-337) as per manufacturer's instruction as in lintels, beams, columns, chajja etc. with necessary scaffolding and protection as required at site from 5th storey to 8th story complete all as specified and as directed.
M&L for providing RCC 1:1.5:3 using 12.5mm graded crushed stone aggregate mixed with plasticiser(Conplast SP-337) as per manufacturer's instruction as in lintels, beams, columns, chajja etc. with necessary scaffolding and protection as required at site from 9th storey to 12th story complete all as specified and as directed.
M&L for providing RCC 1:1.5:3 using 12.5mm graded crushed stone aggregate mixed with plasticiser(Conplast SP-337) as per manufacturer's instruction as in lintels, beams, columns, chajja etc. with necessary scaffolding and protection as required at site above 12th story complete all as specified and as directed.
Use and waste of form work to sides of column soffits and sides of beam, chajja, railing slab etc as in fair finished surfaces complete all as specified and directed for portion of bldg upto 4 storied (rough finish surfaces)
Use and waste of form work to sides of column soffits and sides of beam, chajja, railing slab etc as in fair finished surfaces complete all as specified and directed for portion of bldg from 5th storey to 8th storey. (rough finish surfaces)
Use and waste of form work to sides of column soffits and sides of beam, chajja, railing slab etc as in fair finished surfaces complete all as specified and directed for portion of bldg from 9th storey to 12th storey. (rough finish surfaces)
Use and waste of form work to sides of column soffits and sides of beam, chajja, railing slab etc as in fair finished surfaces complete all as specified and directed for portion of bldg above 12th storey. (rough finish surfaces)
M&L for removal of rusted particle from reinforcement of any diameter using wire brush/emery paper or by grinding and applying two coats of NITOZINC primer for protection of corrosion to old and new reinforcement as per manufacturer's instructions complete all as specified and as directed.
M&L for applying NITOBOND EP for bonding of new concrete with old concrete surfaces complete all as per manufacturer's instructions complete all as specified and as directed.
M&L surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed.
Demolition of unreinforced concrete in ground floors and pavings exc 15 cm thickness above ground level complete all as specified and directed.
Removing excavated material for each additional 50 m or part thereof beyond 50 m and upto a total distance of 250 m.
M&L 50mm thick sand filling under floors or in foundations including watering and consolidation completed all as specified and directed.
M&L 75mm thick Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M&L cement concrete type 'C' 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed.
M&L 50 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in floor and finishing the surfaces fair and even without using extra cement all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all specified and as directed.
M&L providing cement concrete type B0, 1:2:4 (12.5 mm gredded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Taking down cement plaster on internal/external brick or concrete wall etc including racking out joint hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 20 mm thick on brick or concrete surfaces in two coats, first coat 10 mm thick in CM 1:4 and final coat 10 mm thick in CM 1:4 mixed with & including WPC @ 2% by weight of cement or as per manufacturer instructions for final coat, finished surface even and smooth without using extra cement complete all as directed upto 4th storey.
All as per item No 29 here in before but from 5th to 8th storey.
All as per item No 29 here in before but from 9th to 12th storey.
All as per item No 29 here in before but from 13th to 16th storey.
M&L for preparation of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
All as per item No 33 here in before, but for 5th to 8th storey.
All as per item No 33 here in before, but for 9th to 12th storey.
All as per item No 33 here in before, but for 13th to 16th storey.
Supplying and laying of 25mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors at any level of height in high raised bldg etc, complete all as specified including taking down old pipe.
M&L UPVC Brass fittings like Brass elbow / Tee / Sockets / Reducing sockets / MBTA / FBTA / Union / Adaptor etc. suitable for fixing with steel pipe 25 mm dia CPVC pipe fixed in wall / floor complete all as specified and directed.
M&L cast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length, with or without ears, with cement joints, fixed with stack clamps out of 50x5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed including taking down old pipe upto 4th storey.
All as per item No 39 here in before, but for 5th to 8th storey.
All as per item No 39 here in before, but for 9th to 12th storey.
S&F 100 mm dia CI branch piece double, (equal or unequal) ordinary or inverted spigot or socketed type with oval access doors all as specified and directed including taking down old one.
S&F 100 mm bore CI bends (any radius) diminishing pieces or tapers complete all as specified and directed including taking down old one.
M&L preparation of new steel surfaces of eaves gutter and pipes any description, n. exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends in PPR pipe line and fixed including taking down old one.
S C ROY AND CO
NUPUR CONSTRUCTION
SPECIAL CONCRETE AND CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .