Executive Engineer Const.Div.Leh.
Office of the Exe.Engineer Const.Div.Leh
Electrification of Manager Quarter set at ZEBF Chuchot Leh
2022_PWD_8340_4
104 of CDL leh of 2022-23
Open Tender
Electrical Works
Item Rate
15 days
Leh
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Payable To Ex.Engineer const.Div.leh
₹5,540
Yes
6 Dec 2022
5 Nov 2022
28 Nov 2022
6 Nov 2022
26 Nov 2022
6 Nov 2022
Amount
Wiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required (for invator 1 x 1.5 sq. mm
1x 2.5 sq.mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
TV antenna socket outlet
Bell push
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 Amps modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6/16 Amp.
Single pole and neutral 32 amp
Supply and fixing of following sizes of PVC conduit alongwith accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. (for telephone, TV, Internet) 25 mm
Supplying and fixing following size/ modules ,GI box on surface in recess along with modular base & cover plate for modular switches in recess etc as required
4 Module
6 Module
8 Module
12Module
Supply, installation, testing & commissioning of GI Electrode Earthing with 84mm dia and 3 meter length, with 40mm x 6mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact between the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water. The earthing pit should be covered with PVC cover.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or recess for connections etc as required
Supplying and fixing MCCB in cubical panel board Providing and fixing following rating and breaking capacity MCCB FP in existing cubical panel board including drilling of holes cubical panel and making connections etc.As required (Make as per annexure enclosed) MCCB FP 63 Amp 16 KA
Change over Switch 63 Amp.FP
Fabrication, supplying, installation testing and commissioning of following pannel made out of 2mm thick M.S sheet, wall mounted, vermin & dust proof, outdoor type with suitable size of angle iron legs fro grounting in the ground, with lockable type hinged doors, duly painted with provision for fixing of 1 no incomer MCCB, 1No outgoing MCCB, MCCB type change over switch 1 no. including supply and fixing 2 sets of Aluminium Bus Bar, and strips for housing MCB's 12 Nos, MF Digital Meter and other allied accessories etc. as required (Make as per annexure).
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning (Above to 32 Amp.) TPN 63 Amp
SPN 40Amp
Supplying and fixing of 1.1 KV PVC insulated and PVC sheathed XLPE Aluminium Power Cable of following sizes on surface/surface cable tray/0.50 mtr below ground level etc. as required including carriage upto site of work. (Make as per annexure enclosed). 25 sqmm 3.5 core-Armoured
Supplying and fixing of 45 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet/wall. Wipro LR02-501-XXX-57-G1 or equivalent approved make.
Supplying & fixing following luminaries as required 10 watt LED tube light fitting. LL20-111-XXX-65 NE3 wipro or equivalent.make and modal Philips / Crompton Greaves
20 watt LED tube light fitting.Model /make or equivalent make model Philips/Crompton Greaves
Supplying and fixing of Musical Bell including making complete connections etc as required .(Make as per annexure)
Supplying and fixing of Angle /Baten Holder with 9 watt LED Lamp polycarbonate including making complete connections etc as required
Exhaust fan 300 mm size (Heavy duty CG transair or equivalent approved make
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conuctor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/ PVC conduit as required.
M/S TSERING GYALTSAN GOVT CONTRACTOR
M/S HOR CONSTRUCTION COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .