Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC BALLAVPUR BOLPUR BIRBHUM | BOLPUR | BIRBHUM | WEST BENGAL | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹9.9 L+₹20,101.82 (2.06%)Rejected-AOC LOHABAZAR MD BAZAR BIRBHUM PIN 731127 | MD BAZAR | BIRBHUM | WEST BENGAL | 731127 | L2 | Rejected-AOC Being L2 bidder | |
| 3 | L3₹10.0 L+₹21,687.87 (2.23%)Rejected-Finance DANGALPARA P O P S SURI BIRBHUM PIN 731101 | SURI | BIRBHUM | WEST BENGAL | 731101 | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹10.0 L+₹21,915 (2.25%)Rejected-Finance SEHARAPARA DHARAMTALA P O SURI DIST BIRBHUM | SURI | BIRBHUM | WEST BENGAL | 731101 | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹19,600
Closing Date
15 Jul 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Installation of Compounds and security Illumination across the perifary, both internal and external to the boundary wall of the C. Home.
2022_WBPWD_387683_1
BIRED/09/e-NIQ (1st call) of 2022-2023
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
suri
Please refer Tender documents.
8 documents required · 8 mandatory
₹19,600
O/O Exe Eng, Birbhum Elec Divn,PWD
1 Sept 2022
29 Jun 2022
18 Jul 2022
29 Jun 2022
15 Jul 2022
4 Jul 2022
4 Jul 2022
Amount
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ 1(a) i / E-14]
Supply of following PVC/XLPE insulated & Sheathed cables for Working Voltage up to 1100 Volts of following sizes [Make- Havells / Polycab /KEI or As per choice of EIC] 4 core 10 sq. mm. multy stranded alluminium conductor Armoured cable. [NS]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 Core 10 Sq. mm [7(c)/F-4 & 8-b(xi)/F-5]
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire as per GS 1 No Cable up to 4 core 10 sqmm [ 2(b)/ F- 1 ]
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre Incl. following size 1.1 Kv single core stranded 'FR' PVC insulated & unsheathed copper wire as Earthing as per GS. 1 No Cable of 4 core 10 or 35 sqmm incl earthing attachment in 2x 10 SWG GI [Hot Dip] Wire [ 1(a)/ F- 2 & 118/K-3]
Laying of two cables upto 35 sqmm in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed 4C10 Sqmm [5(i)/F-3 & 118/K-3]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. 32 mm dia, [ 11(b)/ F- 6 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5 sq.mm [NS]
S&F Timer DB for intermittent operation of Compound Lights Consisting of following accessories : Double Door IP30-IK08 DB [2 row of 14 M] (Make-Legrand Cat No.-507705) - 1 Nos, Astronomical Digital Time Switch (L&T, Cat No. Astro Mini T2DDT7 1CO) - 1 Nos, 25A FP Contactor having Manual override operation for test & Repair - 1 Nos (Make-Legrand Cat No.-412551) - 1 Nos, FP Isolator 63A- 1Nos, SPMCB 6-32A - 18 Nos.
Charges for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base of pole incl. S&F Section Pipe for cable entry from UG to Loop Box, S&F 3mtr long Earth spike with S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat upto 2 mtr on muffing with GI saddles as required and connection to pole incl. bolts, nuts, washers etc. for street light wiring [NS]
Distribution wiring for street light on pole for outdoor light fitting with 3x1/1.5sqmm PVC FR insulated and unsheathed wire(brand approved by EIC) in 25 mm dia Schedule 40 PVC Pipe, elbow, jointer etc(brand approved by EIC) to be fixed using resibond type glue with suitable metal Clamps 1 mtr apart for holding the pipe with pole, without control switch, incl. fixing the light fitting by providing 32 mm dia GI Pipe steering type bracket having 1M dia on pole incl. S&F suitable MS flat clamps with bolts, nuts etc. as required. [NS]
S&F GI waterproof type PVC cable loop box[Syntex/similar] having 4 mm thick comprising Neutral Link on DIN rail, 4Pole 32 A Stud having lined with rubber gasketted, metalic hinged PVC Door or cover with brass machine screws etc., earthing terminal with lug, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint as required / As per Choice of EIC. (300x250x100)mm (NS)
(200x150x100)mm (NS)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics as per GS[Make-Legrand] 6-32 A SP [ 7 / D- 6 ]
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. [Upto 9.0 mtr. long pole] One coat of red lead/Zinc chromate priming [7A(a)(i) /H-2]
1st coat of synthetic enamel paint over the primer [7A(a)(ii) /H-2]
2nd coat of synthetic enamel paint over the 1st coat [7A(a)(iii) /H-2]
S & F of Out Door LED Flood Light fittings complete with all accessories on existing arm bracket. 100W (Cat no:-FWZP100C0835/Similar Model) [NS]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil. For 2 set dual earthing
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By Tata-Medium GI pipe. For 2 set dual earthing [ 2(a)/G-1 ]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 8 SWG GI Wire for 2 set earthing [ 5a(iii)/G-2 ]
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. For 2 set dual earthing [ 5(d)/G-3 ]
Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per GS by one electrician, one mason and one helper for two days.
Note:- Labour welfare Cess @ 1% and GST @ 12% on Bill amount will be deduct.
M/S SWAPAN KUMAR CHOWDHURY
RIK ENTERPRISE
M/S DAS LIGHT
technical_758578.pdf
PDF • 0.03 MB
techsummary_758578.pdf
PDF • 0.24 MB
finance_758578.pdf
PDF • 0.20 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_758578.pdf
PDF • 0.40 MB
20220901172637968.pdf
PDF • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .