Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹22.7 L+₹1.2 L (5.53%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹19.8 L
EMD Value
₹39,640
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Rahul Rawat
GE Utility Bathinda Mil stn
PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE ELECT OF GE UTILITY BATHINDA MIL STN
2021_MES_424539_1
8542/2020-21/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda MIil Stn
class E cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹39,640
Yes
27 Mar 2021
22 Feb 2021
24 Mar 2021
22 Feb 2021
22 Mar 2021
8 Mar 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches or for manholes etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified. Make :- Topaz / Mehtab/ Shino (Sunshine Industries)
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer / cable cover of any type of cable protection complete all as specified and as directed by Engineer-in-Charge. Note :-Excavation and earth work shall be measured and paid for separately.
Supply and laying or fixing GI tubing light grade 100 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers complete fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench all as specified and directed by Engineer-in charge
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 185 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe of 100 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge.Note : The rate of Galvanised steel light grade pipe of 100 mm dia is included in this item and nothing shall be paid extra on this account.
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe of 80 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge.Note : The rate of Galvanised steel light grade pipe of 80 mm dia is included in this item and nothing shall be paid extra on this account.
Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply and fixing steel tubular swaged pole Single type 410 SP-55 (11 mtr long) conforming to IS - 2713 (Part - I & II) including base plate, Final taper plug, bolts,nuts and screws with two coat of aluminium paint over a coat of red oxide primer and bitumen paint of complete pole upto embedded length and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. Note:- Necessary earthwork and cement concrete work shall be measured and paid seperately in respective items of schedule.
Supply and fixing energy efficient LED Flood light fitting of 120 Watt including No. of LED Flood light bulbs as per manufacturers instructions for light of 120 watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection for connection of cable complete all as specified and directed by Engineer in charge. Make - Phillips BVP130 LED 160-45/740 A or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- For connection of LED light fittings cable from junction box to LED light fittings shall be measured and paid seperately under appropriate item of BoQ.
Supply and laying or fixing GI tubing light grade 40 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers complete fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench all as specified and directed by Engineer-in charge
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4.00 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Supply and laying best quality , locally available well burnt clay brick old size class B laid dry flat for protection over the cable, width equal to the length of cable complete all as specified.
Supply and fixing junction box ,size not less than 200mm x 160mm x 98mm, insulated type , made out with Polycarbonate with glass fiber reinforced. Cat Part No. KF5255 Make of Hensel / Siemens / GE Power / Rittal with MCB SP'C'Curve 2.5 Amp complete as per manufacturers instructions Note :-1.Manufacturer should submit routine test certificate for CJB/PJB 2.The Polycarbonate Junction Box shall be environment friendly, recyclabe, UV resistant, halogen & silicon free, anti acid & anti corrosive. 3. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529. 4.The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. 5.The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60988 - 2 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. 6. The Junction Box color according to RAL 9011. 7.The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For beter safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechnical load shall be in accordance with EN 50298 - 98 for IK 08. 8. The rate of MCB SP'C'Curve 2.5 Amp is included in this item and nothing shall be paid extra on this account.
Material and Labour Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-charge. Note :- 1. The rate of one primer coat, one under coat and one finishing coat of paint is included in this item and nothing shall be paid extra on this account. 2. Payment shall be measured and paid only as per actual weight of Mild steel items. The weight of primer and paint shall not be considered duing measuerment and payment for this item.
Material and Labour for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of poles etc, filling and mass concrete including necessary form work complete all as specified.
Supply and fixing PVC insulated stranded aluminium conductor cable sheathed of Size 6 Sqmm twin core flat, 1100 volts , connection for street light fitting from junction box to LED Fitting complete all as specified and directed by Engineer-in charge.
Material & Labour for distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting, dust and vermin proof , IP-43 protection TPN 2 way 415 volts with bus bar rating 200 Amps including one No MCB triple pole and Neutral 16 Amps 10KA 415 Volt 'C' series, fixing on pole/panel with clamps, nut bolts as specified and direced by Engineer-in-Charge.
Material and Labour Pre Stressed concrete Pole 11 Mtr long 152mm x 152 mm at top 152mm x 260 mm at bottom class 9 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30 cm wide each up to 1.5 mtr height from top of PCC foundation block and numbering of poles complete all as specified and directed by Engineer-in-charge. (PCC for foundations and earth work shall be measured and paid for separately)
Material and Labour PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in coping, foundation of poles/struts etc including necessary form work complete all as specified and directed by Engineer-in-charge.
Supply and fixing Energy efficient LED street light fitting of 60 Watt seasonal LDR with RTC control with dimmable type, including No. of LED bulbs as per manufacturers instructions for lighting of 60 watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 110 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, with auto cut OFF above 300 V & auto switch ON normal voltage, short circuit and over voltage protection facility for Driver should be potted with electrolytic capacitor of 105 degree also with auto cut OFF above 300 V & auto switch ON normal voltage and fitting incluing making electrical connection for cable connection all as directed by Engr-in-Charge. Make HALONIX CAT NO. HLSLD-ML04-60-CWL-DIM / WIPRO LR0260W/HPL CCMSSL60W/HAVELLS CCMSLS60W/C&S INDUS-S60W/PHILIPS CCMSSL60W/CROMPTON SMARTSL60W or equivalent cat part of makes as specified in Appendix ‘A’ approved list of makes / manufacturers here-in-after and approved by GE. Note :- Cable for connection of LED light fitting shall be measured and paid under appropriate item of BoQ.
Supply and fixing Pole mounted ,Hot Press Moulded SMC junction box with side Hinged door,100 % weather proof, Tamper proof, Pilferage proof, Restricts unauthorised tapping, maintenance free, fire retardant, size 250mm x 200mm x 100mm with one number MCB SP 10 Amp , 10KA 'C' series , along with and including GI clamps , nuts, bolts and washers of required size and fixed on pole complete all as manufacturers instructions and directed by Engineer - in - charge. Make Sintex Industries Limited Cat Part No.GSGB-2520 or equivlaent make and cat part as approved by GE. Note : The rate of one number MCB TPN 32 Amp , 10KA 'C' series , along and GI clamps , nuts, bolts and washers of required size is included in this item and nothing shall be paid extra on this account.
Supply and fixing Street light bracket made out of 40mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangement for LED fitting duly painted with two coats of synthetic aluminium paint over a coat of primer including MS clamps and back plates fabricated from steel section including nuts, bolts, washer etc complete all as specified and directed by Engineer-in-charge.
Supply, installation,testing and commissioning of 40 KVA 3 phase AC supply with 300 to 440 V output On-line UPS cum inverter PWM IGBT BASED with inbuilt isolation transformer 3 phase input, 3 phase output including Battery system of sufficient size having atleast 30 min backup including stand for UPS and Battery of suitable size and strenght. of make: Sukam/ABP Power/ Aplab/ Microtek/Luminous. Battery rating - 12 V, 42 Ah- 30 Nos. Battery make - Amaron, Exide, Luminious or equivalent Note:-The rate of 30 Nos. Batteries -12V ,42Ah is included in this item and nothing shall be paid extra on this account.
Supply and fixing of MCCB, 3 phase, 4 pole, 415 volts of capacity 160 Amps, breaking capacity not less than 25 KA, adjustable thermal and fixed magnetic setting, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc making incoming, outgoing connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting , Dust and vermin proof , IP-43 protection , TPN 4 way, 415V, complete all as specified and dircted by Engr in Charge
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Material and labour for 10 sqmm single core x 4 Run sub main 3 phase wiring FRLSH PVC insulated multi stranded copper conductor through and including PVC casing and caping pipe of suitable size as per wiring norms (Heavy duty, ISI marked) on indepent circuit from TPN DB including 6 sqmm single core x two run of FRLSH PVC insulated multi stranded copper conductor as earth wire connected to earth dolly including all fitting arrengement complete all as specified and directed by Engineer- in charge.Notes:-(a) Cost of PVC casing and caping pipe of suitable size and accessories and earth wire included in sub main wiring. (b) 10 sqmm single core x 4 Run , 6 sqmm single core x two run and PVC casing and caping pipe of suitable size as per wiring norms (Heavy duty ) will be measured as one length) (c) Wire , PVC casing and caping pipe & accessories such as Tee , Elbow, junction box, reducer etc.shall be procured from one of the manufacturer as specifed in Appendix'A' here-in- after.
S&F MCB TPN, 100A, 415 V outgoing complete all as specified and dircted by Engr in Charge
Material and Labour for wiring of street light circuit on steel tubular pole / PCC pole with 2 x 2.5 Sqmm + 1 x 1.5 Sqmm earth wire of PVC (FRLS) insulated stranded copper conductor, single core, 1100 Volt grade cable in and including GI pipe light grade 15 mm bore fixed to PCC/steel tubular street light pole with 25 x 3 mm Flat Iron clamps, nuts, bolts & washers complete all as specified and as directed by Engineer-in-Charge. Notes:- (a) 2 x 2.5 Sqmm + 1 x 1.5 Sqmm earth wire of PVC (FRLS) insulated stranded copper conductor, single core, 1100 Volt grade and GI pipe light grade 15 mm bore will be measured as one length. (b) The rate of 25 x 3 mm Flat Iron clamps, nuts, bolts & washers and wiring circuit deemed to be included in this item and nothing shall be paid extra on this account..
Aman Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .