Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC being Lowest Bidder | |
| 2 | L2₹19.2 L+₹24,321.50 (1.28%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹20.6 L+₹1.6 L (8.48%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹46,544
Closing Date
13 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Himanshu, IDSE
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2023_MES_623367_1
GE(S)/PAT/T-52/N/2023-24
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (South) Patiala
₹46,544
Yes
29 Dec 2023
16 Oct 2023
15 Nov 2023
16 Oct 2023
13 Nov 2023
30 Oct 2023
16 Oct 2023 - 23 Oct 2023
Amount
Taking down cement plaster on walls built in cement mortar etc including racking out joints, hacking for key. Scrubbing down with water etc.complete all as specified and directed by Engr-in-charge
M&L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed by Engr-in-charge Note : Water proofing compound shall be measured and paid saparately .
M&L 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
Complete removal of existing treatment of any type/description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed by Engr-in-charge
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits(thickness vary from1.5to2.5mm as required for desired smoothness and levelling of surfaces in two or more layers)by us ingready made wall careputty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engr-in-charge
M&L Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint all as specified.complete all as specified and directed by Engr-in-charge
M&L Preparation of old plastered or unplastered surfaces of walls and applying one coats of cement base paint.complete all as specified and directed by Engr-in-charge
Supply only integral water proofing compound ISI marked.
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-charge
All as per srl item No 9 hereinbefore but n. exc 1.5 sqm each.
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed by Engr-in-charge ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with single rebate including necessary fixing lugs, hinges, lock strike plate, hold fasts ,filling PCC (1:3:6 Co) in chowkhats , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 105x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed by Engr-in-charge ( Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item )
S&F 35mm thick plain framed (Factory made) Panelled shutters of 2nd class HW with lock rail and panels of 9mm B.W.P commercial ply including beading on the facing side of shutters as per SSR Part I clause No 8.17.5. The size of rail and stiles as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-charge
S&F 35mm Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed by Engr-in-charge
S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed complete all as specified and directed by Engr-in-charge
S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 16mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed by Engr-in-charge
S&F MS pressed handles of size 125mm oval type stove enamelled black.complete all as specified and directed by Engr-in-charge
S&F Mild steel butt hinges of size 100mm medium weight cold rolled.complete all as specified and directed by Engr-in-charge
S&F 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified and directed by Engr-in-charge
S& F Factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as shown on drawing noTD-219(c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete all as specified and directed by Engr-in-charge
S&F Steel ventilators fixed type with glazing bars complete all as specified and directed by Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description from metal/wooden frame including punching or drilling out glazing pins/spring clips.complete all as specified and directed by Engr-in-charge
S&F Sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-charge
S&F in stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized wire staples or with wooden beads, screws and nuts botls etc. all as directed.
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed by Engr-in-charge
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed by Engr-in-charge
M&L 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed by Engr-in-charge
Dismantling of floor or wall tiling including cement mortar bedding but not backing and removing the rubbish off the premises complete all as specified and directed by Engr-in-charge
M&L for ceramic floor tiles of minimum size 600X600 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over complete all as specified and directed by Engr-in-charge
M&L for anti skid coloured pressed ceramic floor tiles of minimum size 300X300 mm 8 to 10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid over in complete all as specified and directed by Engr-in-charge
M&L Coloured glazed ceramic tiles (300 x 600 mm) x 7mm or (450X350 mm)X7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), in complete all as specified and directed by Engr-in-charge
Taking up or down steel tubing of size15mm bore and removal to store complete all as specified and directed by Engr-in-charge
Taking up or down steel tubing of size 20mm bore and removal to store complete all as specified and directed by Engr-in-charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 20 mm bore GI tubing.complete all as specified and directed by Engr-in-charge
S&F medium grade galvanised steel tubing with all fittings fixed to wall or laid in floors for 15 mm bore GI tubing.complete all as specified and directed by Engr-in-charge
S&F 20 mm bore ,1 mm wall thickness MS chromium plated curtain rods incl. brackets, stap rollerss fixed in repairs.complete all as specified and directed by Engr-in-charge
Dismantling of wrought timber truss scantling 40Sq.cm and over in section framed work, complete all as specified and directed by Engr-in-charge
Dismantling of wrought timber scantling as in fillets, post rafter , purlins etc under 40Sq.cm in section framed work, complete all as specified and directed by Engr-in-charge
M&L for rectangle / Squar /circular hollow section as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165) complete all as specified and directed by Engr-in-charge
S&F mild steel plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed by Engr-in-charge
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed by Engr-in-charge
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed by Engr-in-charge
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-charge
Demolition of brick work built in cement mortar.complete all as specified and directed by Engr-in-charge
M&L Brick work, with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, using old size bricks complete all as specified and directed by Engr-in-charge
S&F 30mm thick PVC door factory made solid panell shutters concisting of frame made out of MS tubes for top and bottom rails, MS frames shall be covered with hit moulded plain coulour PVC 'C' chanel having a PVC sheet strip of 20mm width stuck in side with screws. complete all as specified and directed by Engr-in-charge
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, fixed in opening as per specification and drawing complete all as specified and directed by Engr-in-charge
M&L Granite (of any type) 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over and including 15mm thick screeed bed or bedding layer in CM (1:4), in complete all as specified and directed by Engr-in-charge
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes icluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm.complete all as specified and directed by Engr-in - charge.
S & F Stainless steel wall mounted kitchen dish rack plate of size 900mm X750mm X 250 mm complete all as specified and directed by Engr-in-charge
S&F 100 mm size PVC butt hinges complete all as specified and directed by Engr-in-charge
S&F 125MM PVC handles complete all as specified and directed by Engr-in-charge
S&F 200mm long PVC tower bolt complete all as specified and directed by Engr-in-charge
S&F PVC(SWR) Floor trap 100mm plain with CP grating including jointing to wate pipe with solvent cement complete all as specified and directed by Engr-in-charge
S&F PVC ( SWR) 110 mm bore single socketed in any length with rubber ring joints fixed to walls or Ground complete all as specified including taking out old damaged water pipes.complete all as specified and directed by Engr-in-charge
S&F PVC (SWR) bends of any radius for 110 mm dia rain water pipes with rubber ring joints a complete all as specified and directed by Engr-in-charge
Dismanteling 1000ltr water storage tank and removing to store, complete all as specified and directed by Engr-in-charge
Rotational moulded polythene water storage tank cylindrical vertical with closed top 1000ltr capacity hoisted and fixed in position incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1.complete all as specified and directed by Engr-in-charge
S & F 125mm Brass chromium plated shower rose complete all as specified and directed by Engr-in-charge
S&F Bib taps for 15 mm dia bore pipe cast copper alloy cromium plated with capstain head screwed down for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-charge
S&F Pillar taps hot and cold Mixer Cast copper alloy fancy type 15mm bore , with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold mixer with long screwed shanks and fly nuts scrrewed for iron pipe and fixed. complete all as specified and directed by Engr-in-charge
S&F stop cock cast copper alloy chromium plated fancy type ,high pressure with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule for 15 mm bore pipe after taking down old stop cock of any description complete all as specified and directed by Engr-in-charge
S&F Angle stop valve(Concealed type) cast copper alloy chromium plated with capstan head , long shank and cup screwed down screwed for iron pipe or for brass ferrule for 15 mm bore pipeafter taking down old stop cock of any description complete all as specified and directed by Engr-in-charge.
S&F 450 mm long PVC connection with brass nuts on both ends for 15mm bore pipes of approved quality complete all as specified and directed by Engr-in-charge
S&F Viterous china, wash hand basin, white, flat back, size 550x400mm including PVC waste pipe 32mm bore and mild steel brackets, fixed all in repairs, including cutting for or pinning in brackets complete all as specified and directed by Engr-in-charge
S&F Tubular towel rail, CP 20mm dia, 60cm long between flanges fixed in repairs.complete all as specified and directed by Engr-in-charge
S/F in repairs low level flushing cistern of PVC 10 ltr capicity incl 45cm long PVC connection with brass nut at both ends, 15 dia stop cock cast copper alloy,screwed both ends , high pressure(wt not less than as specified in SSR), PVC flush pipe 32 mm bore complete all as specified and directed by Engr-in-charge
S&F Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, complete jointing, connecting and making good the disturbed, complete all as specified and directed by Engr-in-charge
M&L Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-charge
M&L PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement, complete all as specified and directed by Engr-in-charge
M&L for chequered cement concrete tiles with grey cement and pigment 20cmX 20cmX25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, over 15 mm thick cement screed bedding layer in cem,ent mortar 1:6, complete all as specified and directed by Engr-in-charge
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring.complete all as specified and directed by Engr-in-charge
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge
S&F Providing and fixing Gypsum Board 12mm thcik in ceiling fixed with screw with 6mm GI wire suspended grid as per manufactures instructions complete all as specified and directed by Engr-in-charge
S&F PVC enclosed case (cabin type) with cover and looking mirror over it with two shelves in it fixed with screws on wall. complete all as specified and directed by Engr-in-charge
Demolition of reinforced cement concrete of any description (Reinforecement cut as required to facilitate demolition ) complete all as specified and directed by Engr-in-charge
M & L for precast RCC 1:2:4, type B-1 as in man hole cover slabs using 20mm graded stone aggregate and set in CM 1:4 including necessary form work complete all as specified and directed by Engr-in-charge Note : Reinforcement shall be measured and paid separately under item No. below
M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified. complete all as specified and directed by Engr-in-charge
M & L for150mm bore, cement concrete bed 1:3:6 type C2, using 40mm graded stone aggregate to drain pipes including packing under and haunching against the sides of pipes after they are laid and fitted complete all as specified and directed by Engr-in-charge
Excavation in trenches not exc 1.5m wide and not exc 1.5m in deep and getting out in soft and loose soil for foundations, etc or for shafts, wells, cesspits, manholes, pier holes, etc complete all as specified and directed by Engr-in-charge
Removing excavated material(soil) to a distance not exc 50mtr and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed by Engr-in-charge
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soils complete all as specified and directed by Engr-in-charge
Reinforced concrete pipes, class NP2 laid and jointed complete with collars bore in pipes 150mm complete all as specified and directed by Engr-in-charge
M&L for cement concreate 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channel and drain complete all as specified and directed by Engr-in-charge
Surface dressing not exc 15 cm deep in soft/loose soil.complete all as specified and directed by Engr-in-charge
M&L PCC 1:4:8, type D-2 using 40mm graded stone aggregate, as in foundation etc. complete all as specified and directed by Engr-in-charge
M&L 40mm thick 1.2.4 type B-0 Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engr-in-charge
M&L for reinforcement cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate) in lintels beams, cantilevers, bressummers complete all as specified and directed by Engr-in-charge
M&L for RCC 1:2:4 type B-1, using 20mm graded crushed stone aggregate as in sun shades/Chajjas/ Fascias/ Lintelbeams/etc including necessary form work and complete all as specified and directed by Engr-in-charge
Use and wste of formwork to edges of concrete flats, floor and roofs n exc 20 cm wide complete all as specified and directed by Engr-in-charge
Use & waste of formwork to sides and soffits of floor and roof beams ,lintels beam ,cantilevers ,shelves including supports ,overhangs and similar work , for rough finished flat surfaces complete all as specified and directed by Engr-in-charge
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surface of concrete.complete all as specified and directed by Engr-in-charge
M&L for Formwork to side of pillars ,post, struts,piers, columns and stanchions complete all as specified and directed by Engr-in-charge
M&L for Mild steel TMT round bars (Fe-500) 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion over all as specified.complete all as specified and directed by Engr-in-charge
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base,complete all as specified and directed. complete all as specified and directed by Engr-in-charge
M&L 100 mm thick (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate as in hard standing etc finished with without using extra cement , .complete all as specified and directed by Engr-in-charge
M&L Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engr-in-charge
M&L PCC (1:3:6), 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement, complete all as specified and directed by Engr-in-charge
S&F Rolled sections as in framing for grills, glazing and the like fixed with angle cleats and connecting plates, etc grade Fe-410 w (Gde-E-250 ) Quality -A , complete all as specified and directed by Engr-in-charge
S&F 4mm dia steel wire, 20x20mm mesh, made up into mattresses or cages, lapped, wired and laid in position, complete all as specified and directed by Engr-in-charge
S&F Fe290 (Gde E-165) Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening.complete all as specified and directed by Engr-in-charge
M&L for reinforcement cement concrete (Normal mix )1:2:4 Type B1 (20mm graded aggregate) as in slab support on wall , beams and collums in floor roof landing balconies deck slab and in shelves and the like.complete all as specified and directed by Engr-in-charge
Dismantling of brick tiles or terracing tiles single layar on roofs complete all as specified and directed by Engr-in-charge
Demolation of mud puska and removing any thickness as directed.complete all as specified and directed by Engr-in-charge
M&L PCC 1:3:6, type B-0 using 12.5 mm graded stone aggregates as in padding over roof ,minimum thickness at khurra as 50mm maintain a slope of 1:100 using water proofing compound finish even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L PCC 1:2:4, type B-0 using 12.5 mm graded stone aggregates as in roof kerbs or mud stops/ coping etc including weathering slightly rounded or chamferred finish even and smooth without using extra cement complete all as specified and directed by Engr-in-charge
M&L for the following roof treatment. (a) 15 mm thick (average) cement screed/plaster in CM 1:4 on roof ( concrete surfces) finishing even and fair all as specified. (b) Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick weight not less than 3.60kg/Sqm water proofing membrane, black finished reinforced with non woven polyester matt, fixed as per manufacturer’s instructions complete all as specified and directed. (c) Applying one coat of bituminous primer confirming to IS-3384 @ 0.3 Ltr/Sqm. (d) Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed. (e) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per square metre including cleaning the surfaces complete all as specified and directed by Engr-in-charge
S&F PVC ( SWR) rain water pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete as as specified complete all as specified including taking out old damaged AC rain water pipes.complete all as specified and directed by Engr-in-charge
M&L Rotational moulded polythene water storage tank cylindrical vertical with closed top 500ltr capacity hoisted and fixed in position incl demolition of exisiting Rcc tank and incl 20 mm bore ball brass valves high pressure with polythene float and fly nut all as specified in SSR Part-1 complete all as specified and directed by Engr-in-charge
Rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement all as specified. complete all as specified and directed by Engr-in-charge
M&L Preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces complete all as specified and directed by Engr-in-charge
M&L Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams, ceilings and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcher with cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including cutting grooves in brick /concrete wall and preparation of surfaces to receive finishes complete all as specified and directed by Engr-in-charge.
M&L for Reinforced cement concrete (Normal mix) , using 20 mm graded stone aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, Footings complete all as specified and directed by Engr-in-charge
M&L Reinforced Cement Concrete(Normal mix) using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job.
All as per item No 119 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 119 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 119 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
S & F Modular switch 1 way 6A, 1 module type all as specified and directed.
S&F Modular Socket, 6A - 5 pin 2 module type all as specified and directed.
S&F Modular switch 1 way 16A, 1 module type all as specified and directed.
S&F Modular Socket 6A/16A - 2/3 pin 2 module type all as specified and directed.
Supply & Fix of modular type, Bell push 1 way, 6 Amps, 1 module complete all as specified and directed by Engineer-in-Charge.
S & F LED light fittings 1 x 20 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete.
S & F in replacement of Exhaust fan metal body AC single phase 230/ 240 V of size 300 mm sweep with louver . Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt all as specified and directed.
S & F Fan step regulator, 120W - 1 module
S & F ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
S & F LED night lamp decorative, wall mounting, with white diffuser with polycarbonate body, holder type suitable for 5 W LED lamp incl cost of warm white Lamp complete all as specified and directed by Engineer-in-Charge.
S & F lamp holder, PVC/ polycarbonate type with back plate suitable for upto 18 watts LED Bulb complete all as specified.
S & F LED Lamp 12 W Warm White Ball Lamp.
S & F LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified by Engr-in-Charge.
M&L for refixing of Ceiling Fan duly painted with 2 coat of paint over one coat of primer all as directed by engr-in-charge.
S & F ceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
M&L for refixing of Geyser 25 Ltr cap incl cleaning of water storage tank of geyser, replacement of Steel flexible Hot & cold water pipe, Plug Top all as directed by engr-in-charge.
Supply & fix in replacement of Bell, ding Dong AC 230 volt single pole complete all as specified and directed by Engineer-in-Charge.
S & F new generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP-65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed.
S & F Post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug, SPN 20 Amps for ACs. Model No. - DHDPHSN020, Make-Havells or equivalent mentioned hereinafter complete all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size. (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
M&L for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x6 sqmm ( line conductor) & 1x6 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size. (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only.
S & F Vertical load line type VTPN DB, 4 way 415 V, double door as per IS - 8623, IP-54 protection, universal mounting with suitable capacity copper bus bar with nuetral bus bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for accomodate MCCB TPN 100 Amp as incomer and TP&SP MCCB/MCBs as outgoing complete & making necessary electrical connection for incoming and outgoing cables, with copper lugs, crimpped with crimping tool complete all as specified and directed. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing shall be part of job.
S&F in replacement of existing MCCB TPN, 63 Amps, 415 volts, 16 KA complete fixing in DBs including proper thimbles connections all as specified and directed.
S & F SPN DB suitable for MCBs of single pole and neutral 12 way as per IS - 8623, IP-54 protection,double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) Dismantling of existing sheet metal box will be deposited to MES. (iii) Masonry work to fill the space of iron sheet box will be part of the job. (iv) Energy Meter will be refixed & connected after fixing of new DB. (v) MCB'S shall be fixed with copper wires FRLS 1.5/2.5 Sqmm incl appropriate size of brass/Cooper thimbles.
S & F SPN DB suitable for MCBs of single pole and neutral 8 way as per IS - 8623, IP-54 protection,double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) Dismantling of existing sheet metal box will be deposited to MES. (iii) Masonry work to fill the space of iron sheet box will be part of the job. (iv) Energy Meter will be refixed & connected after fixing of new DB. (v) MCB'S shall be fixed with copper wires FRLS 1.5/2.5 Sqmm incl appropriate size of brass/Cooper thimbles.
S & F in replacement of MCB SP up to 6-32 Amp all as specified.and directed.
S & F in replacement of MCB SPN 40 Amp complete all as specified and directed.
M & L for replacement of existing earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm, 4 core laid in trenches /on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm, 4 core laid in trenches /on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as apecified and directed.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified.
Returning filling in including, spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying GI tube 40 mm light grade as in cable protection pipe including all fittings & taking down / taking out from trench complete all as directed.
M&L for laying of well burnt Brick 23 cm x11.5 cm x7.5 cm for cable protection complete all as directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, PVC hot & cold water connection pipes etc. all as specified and directed.
S & F Steel water tubing, 15 mm bore, medium grade, galvanised with all fittings and fixed to walls and ceiling or laid in floors for providing water supply connection to the Geyser inlet and out let including extented connection to Kitchen complete concealed or surface run as per site requirement all as specified and directed.
S & F Steel water tubing, 25 mm bore, medium grade, galvanised with all fittings and fixed to walls and ceiling or laid in floors for providing water supply connection to the PVC water storage tank complete concealed or surface run as per site requirement all as specified and directed.
PVC Tank heavy duty 250 Ltr Capacity includingmaiking connections of PVC/GI pipes as per site requirement all as specified and directed by Engr-in-Charge.
S&F heavy duy PVC Tap of 15 mm dia including fittings such as socket, nipple, elbow complete all as specified and directed.
Supply and fix desert cooler electric driven (single phase), 1500 rpm, having nominal air flow capacity of 5000 CuM per hour (or nearest size).(Steel body) duly painted with two coates of enamel paint over one coat of primer with Iron Stand of suitable size and weight including masonary work and grout the stand in wall all as directed by Engr-in-Charge. Note :- (i) Grill will be steel made, (ii) Regulator, Pump Motor, switches will be of good quality. (iii) Water storage capacity 40-50 ltrs.
LM CONSTRUCTIONS
AGGARWAL & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .