| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-Finance | ₹7.3 L | L1 | Accepted-Finance L1 |
| 2 | L2₹7.4 LRejected-Finance | ₹7.4 L | L2 | Rejected-Finance L2 |
| 3 | L3₹7.8 LRejected-Finance | ₹7.8 L | L3 | Rejected-Finance L3 |
| 4 | L4₹8.0 LRejected-Finance F 1 1ST FLOOR EAST JYOTI NAGAR SHAHDARA DELHI DELHI 110093 | NORTH EAST | DELHI | 110093 | ₹8.0 L | L4 | Rejected-Finance L4 |
| 5 | L5₹8.1 LRejected-Finance R 40 VIKAS MARG SAKAR PUR DELHI 92 | ₹8.1 L | L5 | Rejected-Finance L5 |
Tender Value
₹9.3 L
EMD Value
₹19,600
Closing Date
2 Feb 2026, 10:45 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Provision of 3 SHML and street lights to improve Lighting Arrangement at various locations in Darya Ganj Ward no 142, Under Central Zone.
2026_MCD_263713_1
EE(Elect.)/CNZ/2025-26/52-01
Open Tender
Electrical Works
30 days
Ward no 142
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹19,600
5 Mar 2026
26 Jan 2026
2 Feb 2026
26 Jan 2026
2 Feb 2026
26 Jan 2026
Earthing with GI earth pipe 4.5 metre long ,40 mm dia including accessories,and providing massonary encloser with cover plate having locking arrangement and watering pipe etc. (with charcoal /cock and salt as required.)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirming to IS-7098 of following Size (a) 2 X 10 Sq. mm
Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Supplying and fixing of light class GI pipe of 50 mm dia (nominal) 3 meters length along the pole for protection of under ground cable as required.
Fabrication, Supplying, Installation, testing, Commissioning of 12 metres semi high mast System with its accessories, Mast shaft shall be in one section, hot dip galvanized 4mm thick(Single dip) Inside & out sides &sultable for wind velocity as per IS 875 part3.There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For seml High Mast head frame,2 point suspension system,5 X 2.5 sqmm Copper conductor with steel wire rope 5mm dia. (7/19 construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically and its control gears boxes and lighting finial,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) 16 nos.and reinforcement of cold twisted bar of 8 mm dia 3700 mm (approx.) 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the semi high mast considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB,1 . Double pole 16Amp. MCB etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh i/c MV danger plate and grounding the protection system in suitable quality of CC etc as reqd.
Providing and fixing of stainless steel name plate of size 6 X 8 sq inch made of 20 guage sheet including engraved name of area representative duly painted along SS clamp nut bolt etc. as required
LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 45 Watt
Supplying, installation, Testing & Commissioning of Flood Light,powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range - 15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 Watt
Supply and fixing of 32mm dia X 1 meter long G.I. Pipe (Medium Class) bracket for mounting of fluorescent/HPMV/HPSV Street Light fitting on pole including bending the pipe to the required shape , 2 nos 25mm X 6mm flat iron clamps with nuts, bolts and washer , painting the flat iron with primer and finish paint etc. as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3x1.5 sqmm
Supply of XLPE insulated, PVC sheathed Al. Conductor unArmoured cable 1.1 KV grade confirming to IS- 7098 of following Size (a) 2 X 4 Sq. mm
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 12.40 MB
Tendernotice_2.pdf
PDF • 0.10 MB
Tendernotice_3.pdf
PDF • 2.21 MB
BOQ_305920.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid