Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹12.6 L
EMD Value
₹25,260
Closing Date
18 Aug 2020, 4:30 pmClosed
Project Engineer, SICOP Gangyal Jammu
Project Engineer, SICOP Gangyal Jammu
Electrical Works at State Health Society NHM Nagrota.
2020_SICOP_102085_1
SICOP/DEV/72 Dated 10.08.2020
Open Tender
Electrical Works
Item Rate
60 days
NHM Nagrota Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
0116020100000226, IFSC Code JAKA0GNGYAL
₹25,260
Yes
20 Aug 2020
11 Aug 2020
19 Aug 2020
11 Aug 2020
18 Aug 2020
11 Aug 2020
Amount
Supply Installation, Testing and commissioning of Pre-wired recess mounth 2ft x 2ft. LED Panel fitting with Drives etc including connections with 1.5sqmm . FRLS PVC Insulated Copper conductor single cove cable and earthing etc as required. Make wipro/Havells/ Jaquar/ Phillips / HPL
Supply, Installation, Testing and Commissiong of Pre- wired reecrs mounted LED ceiling Light 12W including connections with 1.5 sqmm PRLS PVC Insulated copper conductor single cove cable and earthing as required. Make : Wipro/ Havells/ Jaquar/ Philips/ HPl.
Supply, Installation, Testing and Commissioning of Wall Fan. Make: Havells/ORIENT/V-Guard/ Standard
Supply, Installation, Testing and Commissiong of Ceiling fan, capautor type soctable for Low voltage operation including wiring the down rods of Standard Length (upto 30cm) with 1.5 sqmm FRLS PVC Insulated copper conductor single cove cable including P/F Phenolic Laminated sheet cover on the fan box etc as required (1200mm sweep 5 Star) Make: Havells/V-Gaurd/ Orient/ Standarad
Supply, Installation, Testing and Commissiongof Split Air Conditioners(Hot & Cold) Make: Diakin/o-General/L.G/Voltas
Supply, Installation, Testing and Commissiong of Exhaust Fan with Louvers of following sizes including connections etc as required (complete job) 300 mm Make: Havells/V-gauard/Orient /Standarad
Supply, Installation, Testing and Commissiong of Digital Automatic Stanlozer of following ratings Make: V-gauard/Mocrotek /Livgaurd
4 KVA (90 v to 290 volt)
5 KVA (90 v to 290 volts)
Supply, Installation, Testing and Commissiong of 12.7 mm and 6.4 mm dia Copper Pipe for Non-VRV Air Conditioning System (Compete Job) ISI
Supply, Installation, Testing and Commissiong of Fire Extinguisher,ABC Dry Powder Type of 6 kg Make: SAVMAX/Life guard/Cease fire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required (ISI).
5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required (ISI).
Supplying , Installation, Testing ,making Internal wiring connection and Commissioning of wall mounted distribution panel board with following details suitable for 415 Volt 3-phase-4 wire 50 Hz AC Supply
Panel fabrication details
Size 914 mm X 914 mm X 610 mm
MSCR Sheet
Main Frame 16 guage sheet with lifting
Partition with Hooks 16 guage sheet
Gland & plates 16 gauge Sheet
Power coating Simens grey
Material list for panel board
Providing and fixing following rating breaking capacity and poles MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including panel board including drilling holes in cubical panel making connection etc as required. 100 A, 30KA,FPMCCB 1 no. (ISI)
Providing and fixing capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubical panel making connections etc as required
63 A TP&N= 1 no.
32 A TP&N = 1 no.
Onload changeover Swtich - 4 pole 63 AMP :- 1 No. (ISI)
Volt meter 1 No.
Ammeter 1 No.
Indicator Lamp 1 set
The panel Board should include all wiring with respect to load & all allied accessories for Complete Job.
Panel fabricator CPRI Approved
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (ISI)
Double pole
Single Pole
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A (ISI)
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) (ISI)
12 way (4 + 36), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
200 A, 25 KA,TPMCCB (ISI)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (ISI)
1 or 2 Module
3 Module
4 Module
6 Module
8 Module
12 Module
M/S M M TELECOM
NT ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .