Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹32.8 L+₹1.3 L (4.00%)Qualified Make: UTL
Model: ON LINE UPS 10KVA UTL WITH 120 MIN BACKUP 54 LAKKAR MANDI ROAD SRI GANGANAGAR GANGA NAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | Make: UTL
Model: ON LINE UPS 10KVA UTL WITH 120 MIN BACKUP | L2 | Qualified MSE, Category: OBC | |
| 2 | L3₹35.4 L+₹3.8 L (12.1%)Qualified Make: BPE
Model: BPE 10 KVA UPS with 120 minute 32000 VAH 3year DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: BPE 10 KVA UPS with 120 minute 32000 VAH 3year | L3 | Qualified MSE, Category: General | |
| 3 | Qualified Make: Uniline
Model: Online UPS 10 KVA with 120min backup (Uniline) (Uniline- Maxipower-10KVA) D 174 PHASE 8 B INDUSTRIAL AREA MOHALI | MOHALI | Make: Uniline
Model: Online UPS 10 KVA with 120min backup (Uniline) (Uniline- Maxipower-10KVA) | - | Qualified | |
| 4 | L1₹31.5 LDisqualified Make: AA R KEY
Model: AAR KEY 10.0 KVA 60 MINUTE (Single Phase Input & Single Phase Output) ONLINE UPS MADE IN INDIA OEM BIS REGISTERED MANUFACTURE LAKKAR MANDI ROAD SRI GANGANAGAR RAJASTHAN 335001 | GANGANAGAR | RAJASTHAN | 335001 | Make: AA R KEY
Model: AAR KEY 10.0 KVA 60 MINUTE (Single Phase Input & Single Phase Output) ONLINE UPS MADE IN INDIA OEM BIS REGISTERED MANUFACTURE | L1 | Disqualified MSE, Category: General | |
| 5 | Disqualified Make: NUMERIC
Model: Numeric onfiniti 10 kva UPS D 204 MR MUKESH KUMAR D 204SONIGARA NILLAY BESIDE KUNAL RIVER SIDE CHINCHWADGAON CHINCHWADGAON PUNE MAHARASHTRA 411033 | PUNE | MAHARASHTRA | 411033 | Make: NUMERIC
Model: Numeric onfiniti 10 kva UPS | - | Disqualified MSE, Category: General |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
10 Sept 2018, 11:00 amClosed
Online UPS
Online UPS Experience with Gov. Required 3 Year (s) Online UPS ( 5 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT- PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 120 1/11 Minimum VAH (VAH) 32000 400-640000 Warranty for UPS (Years) 3 1
2
3
4
5 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 2 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put Without With
Without Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes * Indicators for mains Yes * 2/11 presence
Battery charging and discharging
Output Over Load
Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 38935-G * Type Test Certificate date 27-02-2014 * Name of Lab NTH * Address of Lab GHAZIABAD * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001
16 Infantry Divisional Signal Regiment Sadhuwali Cantt 5 21 3/11 Sriganganagar Online UPS ( 7 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15
30
60
90
120
180
240 Minimum VAH (VAH) 16000 400-640000 Warranty for UPS (Years) 3 1
IP20 Cabling 5 meters for input and out put With With
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * 4/11 Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
Battery Voltage and Current Yes * Indicators for mains presence
Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in Yes * 5/11 accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 300EATDBT14S0042 * Type Test Certificate date 9/11/2014 * Name of Lab CPRI * Address of Lab BANGALORE * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001
16 Infantry Divisional Signal Regiment Sadhuwali Cantt Sriganganagar 7 21 Online UPS ( 29 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer
IGBT-PWM without inbuilt isolation transformer 6/11 Input Power single phase 160V - 260V sinewave
240 Minimum VAH (VAH) 9600 400-640000 Warranty for UPS (Years) 3 1
Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per Yes * 7/11 12 V battery. Protection of Over voltage
two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 46/14/BT/NISE * Type Test Certificate date 4/3/2015 * Name of Lab NISE * Address of Lab GURGAON * As per Meity (Government of India) Yes * 8/11 guidelines UPS shall have valid BIS CRS certifications as applicable * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001
16 Infantry Divisional Signal Regiment Sadhuwali Cantt Sriganganagar 29 21
499083
GEM/2018/B/70640
Online UPS,Online UPS,Online UPS
Rajasthan; Ganganagar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS | - | - | - |
| Online UPS Experience with Gov. Required 3 Year (s) Online UPS ( 5 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 10.0 KVA 10.0 KVA Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT- PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 120 1/11 Minimum VAH (VAH) 32000 400-640000 Warranty for UPS (Years) 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put Without With | - | - | - |
| Without Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains Yes * 2/11 presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 38935-G * Type Test Certificate date 27-02-2014 * Name of Lab NTH * Address of Lab GHAZIABAD * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001 | - | - | - |
| 16 Infantry Divisional Signal Regiment Sadhuwali Cantt 5 21 3/11 Sriganganagar Online UPS ( 7 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 16000 400-640000 Warranty for UPS (Years) 3 1 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * 4/11 Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| Battery Voltage and Current Yes * Indicators for mains presence | - | - | - |
| Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in Yes * 5/11 accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 300EATDBT14S0042 * Type Test Certificate date 9/11/2014 * Name of Lab CPRI * Address of Lab BANGALORE * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001 | - | - | - |
| 16 Infantry Divisional Signal Regiment Sadhuwali Cantt Sriganganagar 7 21 Online UPS ( 29 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer | - | - | - |
| IGBT-PWM without inbuilt isolation transformer 6/11 Input Power single phase 160V - 260V sinewave | - | - | - |
| 240 Minimum VAH (VAH) 9600 400-640000 Warranty for UPS (Years) 3 1 | - | - | - |
| Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.0 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per Yes * 7/11 12 V battery. Protection of Over voltage | - | - | - |
| two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. 46/14/BT/NISE * Type Test Certificate date 4/3/2015 * Name of Lab NISE * Address of Lab GURGAON * As per Meity (Government of India) Yes * 8/11 guidelines UPS shall have valid BIS CRS certifications as applicable * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 P Kaliappan 335001 | - | - | - |
| 16 Infantry Divisional Signal Regiment Sadhuwali Cantt Sriganganagar 29 21 | - | - | - |
₹1.2 L
10 Sept 2018
21 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_499083.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .