GEMC-511687746567008
Awarded to ROCKWELL INDUSTRIAL PLANTS LIMITED
₹8.6 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Horizontal Rectangular Sterilizer/ Autoclave | ROCKWELL & Sambion 810 | - | 1 NOS | ₹8.6 L | 855,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.6 LQualified Make: Sambion - Kill Kinetics
Model: ROCKWELL & Sambion 810 B 24 N D S E PART 2 NEW DELHI DELHI 110049 | SOUTH DELHI | DELHI | 110049 | Make: Sambion - Kill Kinetics
Model: ROCKWELL & Sambion 810 | ₹8.6 L | L1 | Qualified |
| 2 | L2₹8.9 L+₹29,750 (3.48%)Qualified Make: National
Model: NATIONAL (NEP-HR-508) 00 SATANPUR SULTANPUR UTTAR PRADESH 228001 | SULTANPUR | UTTAR PRADESH | 228001 | Make: National
Model: NATIONAL (NEP-HR-508) | ₹8.9 L+₹29,750 (3.48%) | L2 | Qualified |
| 3 | Disqualified Make: Accumax India
Model: Accimax Model- 176 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: Accumax India
Model: Accimax Model- 176 | - | - | Disqualified |
| 4 | Disqualified Make: BIOGENIX
Model: BIOGENIX INDIA | Make: BIOGENIX
Model: BIOGENIX | - | - | Disqualified |
| 5 | Disqualified Make: NA
Model: BIO-AUTO1 FLATE NO G 1 5 TELEPHONE NAGAR TELEPHONE NAGAR NEAR BANGALI SQUARE INDORE MADHYA PRADESH 452016 | INDORE | MADHYA PRADESH | 452016 | Make: NA
Model: BIO-AUTO1 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
31 Jul 2018, 4:00 pmClosed
Steam Sterlizer Steam Sterlizer ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use
conforming to IS: 3829(part 1)/1999
fitted with Silicon door gasket( expansion type). Steriliser Chamber size (L x W x H): 1200 mm x 600 mm x 600 mm
Electric load of the unit shall be 18 KW. As per GeM Catalogue. Steam supply to Steriliser From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying Direct Steam Operation from an external source
From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating 1/5 with safety requirements as per IS : 302-2-201(1992)] elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)]
Buil t-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system)
it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber
Jacket
Door
Door Ring and shall be made of SS 304 SS 304
SS 316 or SS 316L Type of control Manual through indt. switch based Manual through indt. switch based
Automatic: MICROPROCESSOR CONTROLLED
WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES - Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the steriliser: No Yes
No Provision of Lock on Steriliser Chamber door: Manual Lock Manual Lock
Automatic Lock
Manual and Automatic Locks
both 2/5 Installation The site ready for installation equipped with water supply
electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. - Type of Door: Radial Type Sliding type
Hinged type
Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature
Low water indicator Chamber Temperature
Cycle number
Batch Number
Time and date
Alarm indicator
Low water indicator Print facility for record generation of dates
time
load
identification number and operating parameters (temperature and holding time etc): Yes
port given to connect an external Printer Unit Yes
port given to connect an external Printer Unit
Yes
by an inbuilt printer unit Warranty Period 3 3
5 No of Doors in Steriliser 1 1
2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is available (If Yes
to be furnished by Seller to Buyer on demand) for the offered product? false 3/5 Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: NA Keyboard interface
Touch screen interface
NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis false Air removal from Sterilisation chamber
after loading the steriliser
by on for more pressure/vacuums pulsing for proper steam penetration YES - Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Yes
with Manually controlled Shredder unit Yes
with Microprocessor controlled
with Manually controlled Shredder unit
Not available Material: Shredder parts; SS 304 SS 304
SS 316 or SS 316L Power of Motor used for Shredding Must be of >= 2 HP
>= 1000 RPM
220 V
50 HZ AC motor
and able to deal with shredding of bio medical waste land as per Steriliser capacity Must be of >= 2 HP
and able to deal with shredding of bio medical waste land as per Steriliser capacity
NA
no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0
2 Long Handle: 1 0
1 Sterilisation Carriages 1 0
1
2 Pull out Trays/Tanks 2 0
2 Floor loading carts 0 0
2 Transfer carriages: 0 0
2 * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 K Kala Alias Saraswathy 605005
RAJIV GANDHI GOVERNMENT WOMEN AND CHILDREN HOSPITAL
100 FEET ROAD
ELLAIPILLAICHAVADY
PUDUCHERRY 1 15
337131
GEM/2018/B/47783
GeM Contract
Steam Sterlizer
GeM Contract
15 days
Puducherry; Pondicherry
PRODUCT
Awarded to ROCKWELL INDUSTRIAL PLANTS LIMITED
₹8.6 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Horizontal Rectangular Sterilizer/ Autoclave | ROCKWELL & Sambion 810 | - | 1 NOS | ₹8.6 L | 855,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Steam Sterlizer Steam Sterlizer ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANG ULAR/SQUARE- Steam Steriliser Pressure type for Hospital and Pharmaceutical use | - | - | - |
| conforming to IS: 3829(part 1)/1999 | - | - | - |
| fitted with Silicon door gasket( expansion type). Steriliser Chamber size (L x W x H): 1200 mm x 600 mm x 600 mm | - | - | - |
| Electric load of the unit shall be 18 KW. As per GeM Catalogue. Steam supply to Steriliser From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying Direct Steam Operation from an external source | - | - | - |
| From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating 1/5 with safety requirements as per IS : 302-2-201(1992)] elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)] | - | - | - |
| Buil t-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system) | - | - | - |
| it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber | - | - | - |
| Jacket | - | - | - |
| Door | - | - | - |
| Door Ring and shall be made of SS 304 SS 304 | - | - | - |
| SS 316 or SS 316L Type of control Manual through indt. switch based Manual through indt. switch based | - | - | - |
| Automatic: MICROPROCESSOR CONTROLLED | - | - | - |
| WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES - Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the steriliser: No Yes | - | - | - |
| No Provision of Lock on Steriliser Chamber door: Manual Lock Manual Lock | - | - | - |
| Automatic Lock | - | - | - |
| Manual and Automatic Locks | - | - | - |
| both 2/5 Installation The site ready for installation equipped with water supply | - | - | - |
| electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. - Type of Door: Radial Type Sliding type | - | - | - |
| Hinged type | - | - | - |
| Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature | - | - | - |
| Low water indicator Chamber Temperature | - | - | - |
| Cycle number | - | - | - |
| Batch Number | - | - | - |
| Time and date | - | - | - |
| Alarm indicator | - | - | - |
| Low water indicator Print facility for record generation of dates | - | - | - |
| time | - | - | - |
| load | - | - | - |
| identification number and operating parameters (temperature and holding time etc): Yes | - | - | - |
| port given to connect an external Printer Unit Yes | - | - | - |
| port given to connect an external Printer Unit | - | - | - |
| Yes | - | - | - |
| by an inbuilt printer unit Warranty Period 3 3 | - | - | - |
| 5 No of Doors in Steriliser 1 1 | - | - | - |
| 2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is available (If Yes | - | - | - |
| to be furnished by Seller to Buyer on demand) for the offered product? false 3/5 Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: NA Keyboard interface | - | - | - |
| Touch screen interface | - | - | - |
| NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis false Air removal from Sterilisation chamber | - | - | - |
| after loading the steriliser | - | - | - |
| by on for more pressure/vacuums pulsing for proper steam penetration YES - Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Yes | - | - | - |
| with Manually controlled Shredder unit Yes | - | - | - |
| with Microprocessor controlled | - | - | - |
| with Manually controlled Shredder unit | - | - | - |
| Not available Material: Shredder parts; SS 304 SS 304 | - | - | - |
| SS 316 or SS 316L Power of Motor used for Shredding Must be of >= 2 HP | - | - | - |
| >= 1000 RPM | - | - | - |
| 220 V | - | - | - |
| 50 HZ AC motor | - | - | - |
| and able to deal with shredding of bio medical waste land as per Steriliser capacity Must be of >= 2 HP | - | - | - |
| and able to deal with shredding of bio medical waste land as per Steriliser capacity | - | - | - |
| NA | - | - | - |
| no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0 | - | - | - |
| 2 Long Handle: 1 0 | - | - | - |
| 1 Sterilisation Carriages 1 0 | - | - | - |
| 1 | - | - | - |
| 2 Pull out Trays/Tanks 2 0 | - | - | - |
| 2 Floor loading carts 0 0 | - | - | - |
| 2 Transfer carriages: 0 0 | - | - | - |
| 2 * Bold specifications are the golden parameters. Consignees and Quantity 4/5 S.No. Consignee Address Quantity Delivery Days 1 K Kala Alias Saraswathy 605005 | - | - | - |
| RAJIV GANDHI GOVERNMENT WOMEN AND CHILDREN HOSPITAL | - | - | - |
| 100 FEET ROAD | - | - | - |
| ELLAIPILLAICHAVADY | - | - | - |
| PUDUCHERRY 1 15 | - | - | - |
Exempted
28 Aug 2018
16 Jul 2018
contract_GEMC-511687746567008.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_337131.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .