Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
1 May 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dharmendra Kumar
POWERGRID, RHQ, NR1, SCO Bay 5-10, Sector-16, Faridabad-121002
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
NR1/NT/S-MISC/DOM/I00/24/05127 (RFX- 5002003440)
Open
Civil Works – General
Fixed-rate
New Delhi
As per Annexure- A-BDS
₹12,500
₹5 L
19 Apr 2024
19 Apr 2024
3 May 2024
19 Apr 2024
1 May 2024
19 Apr 2024
HSN Make Unit Qty
1 SUPPLYING AND ERECTING MAIN LT PANEL. 85371000/ 995461 CPRI approved Nos 1
Supply ,Erection, Testing and commissioning of 250A Main LT Panel front and back operated, totally enclosed ,bottom cable entry, outdoor dust and vermin proof IP 44 cubicle floor mounting fabricated in standard sections, base frame, compartmentalised construction fabricated out of 2mm thick CRCA sheets with powder coated Siemens gray paint RAL 7035 after seven tank treatment, having gasketed & hinged cover on each cubicle with door lock facility, incorporating horizontal & vertical Aluminium busbars and clearance between phase, neutral and earth minimum 25mm distance, heat shrinkable colour coded PVC sleeves throughout the bus bars, complete with all internal wiring, earthing bus and lugs, cable chamber, busbar chamber, PVC name plates, illumination lamps as required as per the requirement with approved GA drawing. Bus bar 200A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped. The Panel shall comprise 2 Nos of incoming 160A MCCB & outgoing termination leads with common bus bar and its accessories as follows, busbar chamber interconnections suitable for mounting arrangements.
INCOMER SECTION:
250A, 36kA 4P MCCB LSIG - 2 Sets with manual interlocking.
OUT GOING SECTION:
32A 3P MCCB - 08Nos
63A 3P MCCB - 10Nos
250A 4P ATS with necessary wiring with controllers.
METERING SECTION:
Multifunction meter capable of reading various parameters like V,A,F,PF,W,VAR,etc including THD measurement with suitable communication port - 1 Set.
CT - 250/5A CL.1 15VA CT - 1 Sets
Bus bar 500A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped.
4P MCB 63A - 1No.
SPD - OBO /Legrand/Schneider 3xMCD50B+1xMCD125B+V20/3FS/Equivalent approved - 1 Sets
2 SUPPLYING AND ERECTING UPS OUTPUT PANEL. 85371000/ 995461 CPRI approved Nos 3
Supply ,Erection, Testing and commissioning of 63A UPS Output Panel front and back operated, totally enclosed ,bottom cable entry, outdoor dust and vermin proof IP 44 cubicle floor mounting fabricated in standard sections, base frame, compartmentalised construction fabricated out of 2mm thick CRCA sheets with powder coated Siemens gray paint RAL 7035 after seven tank treatment, having gasketed & hinged cover on each cubicle with door lock facility, incorporating horizontal & vertical Aluminum busbars and clearance between phase, neutrel and earth minimum 25mm distance, heat shrinkable colour coded PVC sleeves throughout the bus bars, complete with all internal wiring, earthing bus and lugs, cable chamber, busbar chamber, PVC name plates, illumination lamps as required as per the requirement with approved GA drawing. Bus bar 1600A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped. The Panel shall comprise 3 Nos of incoming 630A MCCB & outgoing termination leads with common bus bar and its accessories as follows, busbar chamber interconnections suitable for mounting arrangements.
INCOMER SECTION:
63A, 15kA 4P MCCB LSIG - 1 Set.
OUT GOING SECTION:
32A 4P MCB - 04Nos
32A DP MCB - 6Nos
METERING SECTION:
Multifunction meter capable of reading various parameters like V,A,F,PF,W,VAR,etc including THD measurement with suitable communication port - 1 Set.
CT - 63/5A CL.1 15VA CT - 1 Sets
Bus bar 125A TP+2N Cu. with reinforced angle iron frame work equipped.
3 Supply and installation of UPS Out put Power Distribution wall mounted DB for 25 numbers work station with provision 63A 4 Pole MCB as incomer and sheet metal fabricated, powder coated, having dust and vermin 'proof, gasketed and hinged door, neutral-link, interconnected wiring complete with earthing housing following switchgears: (IP-43) 85371000/ 995461 Nos 2
INCOMER SECTION:
63A 4Pole D Curve MCB - 1No.
OUTGOING SECTION:
16A 2Pole D Curve MCB - 3No.
10A SP D Curve MCB - 20No.
4 Supply and installation of ELDB and UPS UDB wall mounted type with provision 63A 2 Pole MCB as incomer and sheet metal fabricated, powder coated, having dust and vermin 'proof, gasketed and hinged door, neutral-link, interconnected wiring complete with earthing housing following switchgears: (IP-43) 85371000/ 995461 Nos 2
INCOMER SECTION:
63A 2Pole C Curve MCB - 1No.
OUTGOING SECTION:
10A Single Pole D Curve MCB - 16 Nos.
5 Supply,Erection, testing, and commissioning of the wall mounted powder coated Lighting Distribution Board-TPN Flexi Tier DB manufactured with CRCA sheet, vermin proof, dust proof, indoor duty, front door for access, lighting panel board for server hall. Distribution board will have metal casing with double door and shall be fabricated as mentioned and shall have lockable front door & this lock shall be flushed with main door with common key for all DBs. 85371000/ 995461 Each 2
Incomer : 63A 4P MCB -1 No
Sub-Incomer : 40A DP MCB -3 Nos
Outgoings : 10A SP MCB – 30Nos
Blank plate : 6 Nos
6 Supply,Erection, testing, and commissioning of the wall mounted powder coated Power Distribution Board-TPN Flexi Tier DB manufactured with CRCA sheet, vermin proof, dust proof, indoor duty, front door for access, lighting panel board for server hall. Distribution board will have metal casing with double door and shall be fabricated as mentioned and shall have lockable front door & this lock shall be flushed with main door with common key for all DBs. 85371000/ 995461 Each 2
Incomer : 63A 4P MCB -1 No
Sub-Incomer : 40A DP MCB -3 Nos
Outgoings : 20A SP MCB – 15Nos
Outgoings : 10A SP MCB – 15Nos
Blank plate : 6 Nos
7.1 Supply Laying, Testing & Commissioning of 1C x 10Sq.mm Copper flexible cable. 85446090 Mtr 400
7.2 Supply Laying, Testing & Commissioning of 4C x 70 Sq.mm Aluminum armoured cable. 85446090 Mtr 300
7.3 Supply Laying, Testing & Commissioning of 4C x 16 Sq.mm Copper flexible cable. 85446090 Mtr 200
7.4 Supply Laying, Testing & Commissioning of 4C x 10 Sq.mm Copper flexible cable. 85446090 Mtr 500
7.5 Supply Laying, Testing & Commissioning of 4Cx6 sq.mm Cu.Flex.Cable 85446090 Mtr 320
7.6 Supply Laying, Testing & Commissioning of 1Cx16 sq.mm Cu.Flex.Cable - Green Rack Earthing 85446090 Mtr 100
7.7 Supply Laying, Testing & Commissioning of 1Cx6 sq.mm Cu.Flex.Cable - Green Stud Earthing 85446090 Mtr 200
7.8 Supply Laying, Testing & Commissioning of 3Cx1.5 sq.mm Cu.Flex.Cable - Lighting. 85446090 Mtr 400
# CABLE END TERMINATION
Supply and Installation of non-metallic cable glands (PVC /Rubber) for single/multi core flexible, non-armoured cables, including crimping type aluminium/copper lugs, paste, insulation tape, heat shrinkable R, Y, B, color PVC sleeves (in case of black color cables) for phase identification, hardware, consumables, fixing of permanent cable identification tags etc. as required in following sizes. The lugs shall be aluminium or copper respectively for aluminium or copper cables. Proper size of identification ferrules to be provided in all cables.
8.1 Supply Laying, Testing & Commissioning of 1C x 10Sq.mm Copper flexible cable. 85369090/ 995461 Nos 16
8.2 Supply Laying, Testing & Commissioning of 4C x 70 Sq.mm Aluminum armoured cable. 85369090/ 995461 Nos 4
8.3 Supply Laying, Testing & Commissioning of 4C x 16 Sq.mm Copper flexible cable. 85369090/ 995461 Nos 8
8.4 Supply Laying, Testing & Commissioning of 4C x 10 Sq.mm Copper flexible cable. 85369090/ 995461 Nos 4
8.5 Supply Laying, Testing & Commissioning of 4Cx6 sq.mm Cu.Flex.Cable 85369090/ 995461 Nos 4
8.6 Supply Laying, Testing & Commissioning of 1Cx16 sq.mm Cu.Flex.Cable - Green Rack Earthing 85369090/ 995461 Nos 16
8.7 Supply Laying, Testing & Commissioning of 1Cx6 sq.mm Cu.Flex.Cable - Green Stud Earthing 85369090/ 995461 Nos 32
8.8 Supply Laying, Testing & Commissioning of 3Cx1.5 sq.mm Cu.Flex.Cable - Lighting. 85369090/ 995461 Nos 60
9 Supply and Installation of 200x50x1.6mm MS powder coated White colour perforated type cable tray with coupling accessories.(Rack power) 73089090/ 995461 Mtr 50
10 Supplying and erecting of box type trunking LV Tray 300 mm Wide x 50mm Deep x 2 mm Thick with divider pre-fabricated in factory with cover but with a central divider panel, for flooruse of any anchor-fastners etc. The cost to also include all required pre-fabricated bends, tees, crosses and including the necessary arrangement. 73089090/ 995461 Mtr 100
11 Supplying and erecting of box type trunking LV Tray 150 mm Wide x 50mm Deep x 2 mm Thick with divider pre-fabricated in factory with cover but with a central divider panel, for flooruse of any anchor-fastners etc. The cost to also include all required pre-fabricated bends, tees, crosses and including the necessary arrangement. 73089090/ 995461 Mtr 150
12 Supply, installation, testing and commissioning of power points by providing following switches/sockets mounted on suitable size metal /pvc boxes fixed flush/surface on to the wall with all Installation and wiring accessories 1x10/20 Amps,(230 Volts) single phase twin socket with 1x20 Amps single way switch with indicating lamp. Plug tops are excluded from the scope of supply. (Raw /UPS power Sockets) 85369090 Each 82
13 Supply, installation, testing and commissioning of power points by providing following with 25 mm PVC conduit and 2R x 2.5 sq.mm + 1R x 2.5 sq.mm wires fixed flush/surface on to the wall with all Installation and wiring accessories. 85369090 Mtr. 1200
14 Supply & Installation of Copper plate 600x600x3mm Earthing system - 48 mm Diameter water charging, wall thickness 1.2mm,with all accessories. As per is 3043 IS code 85359090 Each 4
15 Supply & Installation of GI plate 600x600x6mm Earthing system - 48 mm Diameter water charging, wall thickness 1.2mm,with all accessories. As per is 3043 IS code 85359090 Each 4
16 Supply and erecting 25 x 3mm cu.earthing flat with necessary drilling,cutting and hardware with double washer etc as per the requirements. 74091900 Mtr 460
17 Supply and erecting 25 x 5mm GI.earthing flat with necessary drilling,cutting and hardware with double washer etc as per the requirements. 74091900 Mtr 600
18 Supplying and erecting Tinned Copper Earth Bus Bar of size 40 x 6 x 300mm long with suitable MS fabricated bus bar box with green powder coated painting as required. 74091900 Each 4
19 Supply & Installation of LED based Continuous/single piece Light fitting 600 mm x 600 mm to be ceiling suspending from LV cable trays having integral driver with diffuser. The fitting should be complete with all necessary hardware required for suspending from ceiling or for fixing directly below the cable trays. 94054090 Each 75
20 LED base decorative EXIT light suspended from ceiling 94054090 Each 20
21 Supply & Installation of Occupancy Sensor capable of sensing small movements Passive Infrared Dual Lens or Ultrasonic or Microwave)mounted on the ceiling and wired through the lighting circuitfor automatic control of the lights. The sensor should have a minimum sensing range of 7.5 meter diameter and rated at 10 A with built-in adustable time delay up to 10 minutes.The sensor should also have adustable light level sensitivity for control through ambient lighting. 85176990 Each 8
22 Providing UPS power point wiring for work stations and security table with 25mm conduit and 1.5Sq.mm. copper flexible cable including 3Nos x 5 pin socket + 1x 10A switch. 85369090/ 995461 Nos 45
23 Providing Data and Voice dual face plate of RJ45 and RJ11. 995461 Nos 60
24 Supplying and laying 1mt x 10mt x 2mm thick ISI marked rubber mats to be laid in front of the panel boards. 40169100 Sq.Mtr. 4
S. No. ITEMS UNIT QTY HSN Code
A Part "A" (High Side)
1 Supply of Outdoor Units- VRV-X System Make- DAIKIN or equivalent HEATING & COOLING (R410A) Supply of Modular type outdoor units equipped with highly efficient scroll compressors with 100% inverter technology type compessors special heat exchanger, low noise condenser fan , auto check function for connection error, auto address setting and The condensing unist shall be sutaible for operation on 415+ 10% Volts , 50 Hz, 3 phase A.C power supply & Condensing units capacity as mentioned below
i ODU -34 HP Heating & Cooling Top Discharge No. 1
ii ODU -36 HP Heating & Cooling Top Discharge No. 1
Supply of Indoor units address setting & capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain water lift-up mechanism insulation, pipe connections etc.
i 3.3 Ton 4- Way Cassette Units - with Panel Nos. 3
ii 1.65 Ton 4- Way Cassette Units - with Panel Nos. 2
iii Hi wall - 2.08 Nos. 5
iv Hi wall - 1.65 Nos. 17
v Refrigerent joint Nos. 25
vi Cordless Remote Nos. 27
i Split - 1.8 Tr Non-Inverter Nos. 4
B Part "B" (Low Side Work)
Lifting, shifting, positioning, installation of complete System comprising of 2Nos. of Outdoor unit & 27 nos of indoor unit.
i ODU -34 HP Heating & Cooling Top Discharge No. 1
ii ODU -36 HP Heating & Cooling Top Discharge No. 1
i 3.3 Ton Cassette Units - 4 Way Nos. 5
ii 1.65 Ton 4- Way Cassette Units - with Panel Nos. 2
iii Installation Of Hi- wall Nos. 22
ii Dismentalling Of Old split a.c Nos. 28
iii Refrigerent joint Nos. 25
iv Cordless Remote Nos. 27
2.0 Testing, Commissioning of complete System comprising of 2 no of Outdoor unit & 27 nos of indoor unit . Ckt 2
3.0 Refrigerant piping
Inter-connecting refrigerant pipe work with (19mm/13mm thick) closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS chanell / hangar.
i Pair of refregration duly insulated with 19/13mm nitrile rubber RMT 185
4.0 Control & Transmission wire
i 2 Core x 1.5 Sq mm copper in suitable conduits between indoor & outdoor unit. Rmt 215
ii 3 Core x 2.5 Sq mm copper flexible wire to connect indoor units from power point. Rmt 15
5.0 PVC Drain piping
Providing & fixing of PVC Drain piping - Rigid PVC piping complete with fittings, supports as per and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
25mm Dia RMT 125
32 mm Dia RMT 85
40mm Dia RMT 35
6.0 Outdoor stand
i M. S. C chanel black enamel painted outdoor stand units. Nos. 4
ii Supply and Fixing of GI Tray (150x300 x150) along with cover, supports, C Channel etc for exposed piping on terrace. RMT 15
iii Supply and Fixing of GI Tray (50x200 x50) , supports, C Channel etc for Internal piping on Floor. RMT 20
i Installation Of Split A.c Nos. 4
ii Pair of copper pipe with Insulation RMt 25
iii Providing & fixing of Interconnected Electrical wiring between Indoor & Outdoor
Transmission wire 4c x2.5 Sq mm RMt 30
iv Providing & fixing of PVC Drain piping -
25 mm Dia Nos. 20
v Wall Stand for outdoor Units Nos. 4
8.0 Providing Nitrogen & pressure test between Indoor & Outdoor refrigerant pipe - 34 &36 HP Nos. 2
9.0 Vacuumization and Additional Gas Topping /Filling ckt 2
Sitting AREA-Size 52x22 (SOC ROOM)
Sl No Description of Work UOM Qty HSN/SAC
1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 4
5 BMs room build with gypsum size 5x5 nos 1
6 Rest room build with gypsum size 5x5 nos 1
7 Paint & putty sq ft 925
8 Doors fire rated nos 3
9 work station desk (make Godrej/Pyrotech/Cosmos or equivalent) nos 21
10 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 21
11 Three seater sofa with table in rest room (make leatherite Godrej) set 1
12 ceiling sq ft 1144
13 Video wall_Panelling works (wooden paneling for 8 Nos.(4x2 Matrix) 55" LCD/LED Video Wall) Lot 1
DC Room-Size 24x16
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 4
5 Paint ,putty sq ft 480
6 Doors fire rated nos 1
7 ceiling sq ft 384
8 Rised floor sq ft 384
UPS Room-Size 10x12
1 Puff partition and puff ceiling Lot 1
2 Raised floor sqft 120
Forensic Lab-Size 6x12 (room no-308)
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 4
5 Paint ,putty sq ft 220
6 Doors fire rated nos 1
7 ceiling sq ft 72
9 work station desk (make Godrej/Pyrotech/Cosmos or equivalent) nos 4
10 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 4
Gallery-Size 160x12
1 Dismantelling of ceiling, Doors, Windows, PVC sheet, Grills, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) & RCC work for slab inplace of PVC sheet Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 4
5 Paint ,putty sq ft 2880
6 Doors fire rated glass Double Leaf (Size3000X3300mm) nos 2
7 Ceiling sq ft 72
8 Texture painting sq ft 1440
9 Wooden Paneling in Ceiling lot 1
10 Network Room Renovation and dressing of Cables and Rack lot 1
1 2 nos of CCTV system set up Lot 1
2 2 nos of access controll system setup Lot 1
3 Lan port set up(approx 25 nos) Lot 1
4 Almirah for keeping the hard disk etc (For reference- Godrej Dataline Media Safe) Qty 2
311,318,316,315(Every room size 15x15)
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 4
5 Paint ,putty sq ft 4600
6 Doors fire rated glass nos 4
7 Ceiling sq ft 720
8 Wooden work on wall lot 1
9 Wooden paneling in ceiling lot 1
10 Carpet Tile on floor lot 1
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 7
5 Paint ,putty sq ft 1540
6 Doors fire rated nos 7
7 ceiling sq ft 504
Room no 303&304(Conference room)
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
Dismantelling of Wall Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 Windows closer (With Brickwork & plaster, complete) nos 1
5 Paint ,putty sq ft 720
6 Doors Steel with vision glass nos 3
7 Ceiling sq ft 72
10 Carpet Tile on floor lot 1
11 conference table for20 seat (make Godrej) nos 1
12 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 30
13 Av solution for Conference room lot 1
14 Wooden work on wall Lot 1
1 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1
Dismantelling of Wall Lot 1
2 Cleaning of site (All Debris, complete) Lot 1
3 Repairing work (Minor Brickwork with plaster) Lot 1
4 12 mm toughned glass(3000x32000)with theame nos 1
5 Paint ,putty theame based sq ft 720
7 Ceiling sq ft 72
10 Carpet Tile on floor lot 1
11 Reception table for2 seat (make Godrej) nos 1
12 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 2
13 wooden panelling for beam nos 12
14 Wooden work on ceiling Lot 1
15 One stand fan (make crompton, havels or equivalent) Lot 1
16 Exausht grill Lot 1
1 Dismantelling of ceiling Lot 1
2 Cleaning of site Lot 1
3 Repairing work Lot 1
4 Windows closer nos 7
5 Paint ,putty sq ft 1540
6 Doors fire rated nos 7
7 ceiling sq ft 504
Washroom Renovation-3nos
1 Washroom Renovation Lot Lot 3
2 Emergengy exit stair door Lot 1
4 Fire rated door for Roof area nos 1
Sr. No. Description Unit Qty
1 55" Full HD LCD/LED Video Wall No. 8
2 Automatice Data Processing Machine with Controller as per speciifcation No. 1
3 Wall Mount accessories Lot 8
4 10 M DVI Cable to Connect LVS to Controller No. 12
5 Installation & Commissioning Lot 1
6 Warranty 3 Year Lot 1
SOC Room Interior Work (Details are attached in Annexure-I)*
S.No Description Unit Qty HSN/SAC
1 Supply of Modular rigid PVC metal Panelling Sq Ft 496
2 Supply of Modular rigid PVC metal partition Sq Ft 177
3 Supply of Printed metal panelling Sq Ft 47
4 Supply of Curve/bend Modular rigid PVC metal Panelling Sq Ft 170
5 Supply of 12mm Thick Frameless Tempered Clear Glass Door Size (±100mm) :- 1440mm X 2100mm No's 2
6 Supply of Designer Acoustic Metal False Ceiling Sq Ft 390
7 Supply of Designer Calcium Silicate Ceiling Sq Ft 174
8 Supply of Round LED Ceiling Light (Static) No's 30
9 Supply of Cove light (Static) R. Ft 101
10 Supply of Wires, Switches & Conduits for Ceiling Lights Sq Ft 537
11 Supply of Designer Acoustic Flooring Sq Ft 582
12 Supply of Granite Stone for Floor Highlighter/steps Sq Ft 52
13 Supply of CORPORATE LOGO Nos 1
14 Supply of Designer Privacy Film for Glass Partition/Glass Door Sq Ft 47
15 Supply of New Modular Control Desk for provision of 05 monitors & 05 Operators made in " XLAT " system. No's 2
16 Supply of New Modular Control Desk for provision of 01 monitor & 01 Operator made in " XLAT " system. No's 4
17 Supply of Chair No's 14
18 Scope of Design Lot 1
19 Project Management/Supervision Charges for Installation & Commissioning for Control Room Interior Lot 1
Annexure-I: Technical Specifications
SOC Room Interior Technical Specification
S.No Detailed Description Unit Quantity
1 Supply of Modular Rigid PVC Metal Panelling 1) Factory made removable type self inter lockable metal panels with front sheet of Preformed Textured Hot dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating atleast 0.11mm). The back cover of the panel shall be made up of 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of specially designed combination of perforated and nonperforated panels through CNC laser Cutting, bending & punching. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on structure. The metal panelling/partition shall be greenguard gold tested/certified (from UL/Intertek). Valid certificate/test report to be submitted along with the technical bid. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm. 2) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the control room it is necessary that the wall panelling shall have micro-perforations (less than 1.6mm diameter each) all over the surface with a density of 5000 holes per square feet. UL audit certified design feature on modular wall panelling tile having clean perforations and providing smooth finish on front fascia of tiles. The tile shall have 5000 holes per square feet on front side of the tile. Valid certificate/test report to be submitted along with the technical bid. 3) To provide acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and partition shall be minimum 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part I- 1984, ISO: 16283 (Part I) -2014. Valid certificate/test report to be submitted along with the technical bid. 4) The modular metal panelling shall comply to the lead-free directive to ensure restriction of hazardous substances so that the final product does not contaminate the environment. The final product i.e., modular metal panelling does not contain hazardous substances and we give a healthy life to our coming generations it is necessary that the modular metal panelling system shall be RoHS certified/tested (from UL / Intertek). Valid certificate/test report to be submitted along with the technical bid. Sq Ft 496.00
5) From fire safety point of view the metal wall panelling tiles shall be class A fire rated as per the norms of comparative measurements of surface flame spread and smoke density measurements with that of select grade red oak and fiber-cement board surfaces under the specific fire exposure conditions. The proposed wall panelling tiles shall be Class A certified/tested as per ASTM e84 (from UL/Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. Valid certificate/test report to be submitted along with the technical bid. 6) Seismic safety of user & control room equipment is a prime concern area. The metal panelling shall sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 or better vibrations. The test shall be carried out by authorized government agency. Valid certificate/test report to be submitted along with the technical bid. 7) The wall panelling shall be robust & strong enough to sustain the routine loads/minor impacts of typical control room environment. The wall panelling/partition structure shall have UL Audit certified feature of Load bearing capacity of 300 Kgs to hold any display unit on clamp having minimum length of 750mm. Valid certificate/test report to be submitted along with the technical bid. 8) As control room is a mission critical area and in an unlikely case of damage to the existing wall panelling tiles the same shall be replaceable within 20 seconds and thereby preventing loss of time of operators and ongoing operations. UL Audit certified feature of Modular wall panelling tile having secure locking arrangement for equidistant mounting. Locking arrangement enables easy replacement without using any tool within 20 seconds. The feature shall provide easy flexibility of locking all tiles in one column through gravity. Valid certificate/test report to be submitted along with the technical bid. 9) The panelling and partition system shall qualify fire rating of at least 45 minutes in accordance with BS 476 Part 20 & 22. Valid certificate/test report to be submitted along with the technical bid. 10) Structure shall be made from modular, heavy-duty powder coated CRCA frame (minimum sheet thickness 1mm) and shall allow uninterrupted flow of wires/cable/tubes of maximum diameter 25mm.
2 Supply of Modular rigid PVC Metal Partition 1) The material of construction and technical specification shall remain the same as per modular rigid PVC metal panelling (Wall Finishing - modular rigid PVC metal panelling) however, In partition the cladding shall be done on either side of the section/grid work. Factory made removable type self inter lockable metal panels with front sheet of Preformed Textured Hot dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating atleast 0.11mm). The back cover of the panel shall be made up of 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of specially designed combination of perforated and non-perforated panels through CNC laser Cutting, bending & punching. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on structure. The metal panelling/partition shall be greenguard gold tested/certified (from UL/Intertek). Valid certificate/test report to be submitted along with the technical bid. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm. Sq Ft 177.00
3 Supply of Printed Metal Panelling 1) The printed panelling shall have the same technical specifications as that of modular rigid PVC metal panelling (Wall Finishing - Sr No. 1 modular rigid PVC metal panelling). However, in addition to it, the front tile shall be digitally printed. Graphics shall be approved by the Customer. 2) Digital printing shall be done on modular metal Panelling. Pasting stickers/flex/vinyl on metal tile shall be deemed unacceptable. 3) The structure shall be made from a modular, heavy-duty powder-coated CRCA frame (minimum sheet thickness 1mm) and shall allow an uninterrupted flow of wires/cable/tubes of maximum diameter 25mm. 4) The structure shall be securely connected from wall, roof and floor. It shall be made up of a minimum of 1mm thick vertical slotted rolled C sections (Upright) and horizontal rolled ‘C’ connectors. Grid of the desired dimension shall be formed by Vertical and horizontal sections having 20 to 50mm pitch. 5) For Structure: - Powder coated CRCA steel sheet. (Sheet thickness minimum 1.0mm with powder coating). Sq Ft 47.00
4 Supply of Curve/Bend Modular Rigid PVC Metal Panelling 1) The material of construction and technical specification shall remain the same as per modular rigid PVC metal panelling (Wall Finishing - Sr No. 1 modular rigid PVC metal panelling) however, the shape shall be a perfect curve to provide more space for mounting of the LED. Panelling’s curve shall be achieved by curved tiles only. Curvilinear arrangement using straight tiles shall be deemed unacceptable. Factory made removable type self inter lockable metal panels with front sheet of Preformed Textured Hot dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating atleast 0.11mm). The back cover of the panel shall be made up of 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of specially designed combination of perforated and non-perforated panels through CNC laser Cutting, bending & punching. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm. Sq Ft 170.00
5 Supply of 12mm Thick Frameless Tempered Clear Glass Door Size (±100mm) :- 1440mm X 2100mm With door spring and locking arrangements and both way handle and patch fittings. Specifications : Tempered glass is formed by heating glass to the softening point in a horizontal tempering stove, and then quickly cooling it. Properties: 1) Safety (tempered): when broken, it spits into tiny harmless pieces 2) Strong intensity: heat-strengthened glass is approximately twice as strong as annealed glass of the same thickness, and tempered glass is about 4 times 3) Outstanding performance in resisting thermal stress and wind-load 4) Tempered glass cannot be cut, drill hole and other further processed. No. 2.00
6 Supply of Designer Acoustic Metal False Ceiling 1) Factory made acoustic modular metal false ceiling of powder coated panels. Make shall comprise of perforated and non-perforated metal panels made through CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of approved powder coating finish. Panels shall be designed to achieve shape and design as per the design consultant with the combination of acrylic panels with lights, designed to enhance visual feel, with provision for easy installation and maintenance, integrated lighting and scope for integration of building services like HVAC and fire detection/ fighting system. The designer metal ceiling shall be greenguard gold tested/certified (from UL/Intertek). Valid certificate/test report to be submitted along with the technical bid. Metal modular false ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90. 2) It is well known that metal is resistant to fire as compared to wood & fabric. However, from fire and safety point of view, to ensure that the used material is not subjected to any kind of surface treatment which provokes fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84 (from UL / Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. Valid certificate/test report to be submitted along with the technical bid. 3) To ensure restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the modular metal ceiling system shall be RoHS certified (from UL / Intertek). Valid certificate/test report to be submitted along with the technical bid. 4) To avoid dark spots/areas in the control room it is necessary that continuous linear lights are used across the width/length of the control room. UL audit certified design feature of integrated channel in ceiling for quick installation & replaceability of continuous linear light: The ceiling system having integrated inbuilt channel for installation of cove lights and shall permit quick and easy replacement of cove light without using any tools. Replacement to be carried out within 120 Seconds per meter. Valid certificate/test report to be submitted along with the technical bid. 5) Seismic safety of user & control room equipment is a prime concern area. The metal ceiling shall sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations or better. The test shall be carried out by authorized government agency. Valid certificate/test report to be submitted along with the technical bid. 6) Structure shall be made from heavy duty powder coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm). It shall be securely grouted from roof with help of anchor fastener and GI self-threaded rods. It shall be formed with the help of slotted rolled W sections (stiffener) and Master C section with help of M6 cage nut and bolts. Sq Ft 390.00
7 Supply of Designer Calcium Silicate Ceiling Plain Calcium Silicate Acoustic Boards for false ceiling with 08mm Approximately thick, Structure for underside of suspended grid formed of GI perimeter channels. Wood screws and metal expansion raw plugs for fixing with wall. Plastic emulsion paint of approved make and shade for finishing surface of Calcium Silicate Boards. Specification: Calcium Silicate Board is manufactured from a mixture of Portland cement, fine silica, special cellulose fibers and selected fillers to impart durability, toughness, fire and moisture resistance. Sq Ft 174.00
8 Supply of Round LED Ceiling Light (Static) High performance LED downlighter with high system efficacy for good quality and uniform lighting. Conforms to general lighting norms for office and other indoor applications. 1) Colour Temperature (K)- 3000 K / 4000 K / 5700K (as per site conditions) 2) LED Efficacy (lm/W) – 100 to 160 3) CRI >70 4) Power Consumption 6W to 24W 5) LED’s life >25,000 hours @ L70 No. 30.00
9 Supply of Cove light (Static) It will be a continuous rail of LED light, high brightness, neutral, or warm white with wall washing applications. Its slim profile and simple daisy-chain system allows high design flexibility to form long. 1) Light source: LED 2) Lumen output: 500 lm/m 3) Light color: 6500K 4) Power consumption: 3W/m to 5W/m 5) Operating Voltage Range (V) 100 – 300 6) Operating Frequency (Hz) 50 ± 3% 7) Colour: White 8) Lifetime: 15000 burning hrs. (At L70) R/Ft 101.00
10 Supply of Wires, Switches & Conduits for Ceiling Lights Wires for ceiling lights inter looping and switches will be provided, consisting of PVC insulated copper conductor stranded flexible FRLS wires of 1100 volts grade of insulation in metallic conduits. Minimum size of copper conductor shall be 1.5 sq. mm for lighting and 2.5 sqmm for power. color of wires shall be Red/Yellow/Blue (or as per Local Standards) for the all single phases, Black for neutral and Green for earthing. Sq Ft 537.00
11 Supply of Designer Acoustic Flooring To avoid distraction of operators because of unwanted noise generated from movement of chairs/people in the control room it is necessary that the proposed flooring shall damp such impact noises. Acoustic flooring (shall reduce impact sound by 14dB (ISO 717-2)). It shall be twinlayer linoleum built up from minimum 2mm acoustic laminate and a 2mm corkment backing. Flooring shall be decorative type of approved shade, pattern, texture and design and of approved manufacturer. The designer acosutic flooring shall be Greenguard Gold certified from (UL / Intertek). Valid certificate/test report to be submitted along with the technical bid. Dimensions shall be as per the final approved design and site requirement. Flooring shall be laid over concrete floor with laying compound strictly as per manufacturer’s specification Sq Ft 582.00
12 Supply of Granite Stone for Floor Highlighter/steps in required design and pattern, with 12mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) laid and joint with white cement slurry including pointing with white cement slurry admixed with pigment of matching shade as directed by the Engineer-in-Charge. Sq Ft 52.00
13 Supply of CORPORATE LOGO Lot 1.00
14 Supply of Designer Privacy Film for Glass Partition/Glass Door The film to be installed on clear glass to provide the look of sandblasted glass. Sq Ft 47.00
15 Supply of New Modular Control Desk for provision of 05 monitors & 05 Operators made in " XLAT " system. 1. Table top: - The material of the working surface shall be minimum 25 mm thick MDF with High Pressure ANSI/NEMA LD3 certified scratch-resistant laminate. The proposed console's life cycle shall be assessed (from approved LCA consultant) for environmental impacts associated with all the stages of a product's life for cradle to grave analysis. 2. Structure: Made of heavy duty extruded vertical and horizontal aluminium profiles of 6005 grade. The extrusions shall be duly powder coated with 40+ microns over all surfaces. All sheet metal parts shall be finished with a durable, black, electrostatic powder coating. To ensure that the offered product is an engineered solution. To allow future extension and expansion, a weld free system shall be proposed. Interconnecting joints shall not be visible. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 tests. The structure shall allow easy assembly of hinged shutters, slat wall, gland plate, and monitor arms in extremely rigid manner. The EPD (Environmental product declaration) of console shall be verified in accordance with ISO 14025 (from UL/Intertek) for Impacts on Environment by console. Operator consoles shall be tested and qualified to sustain seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations with monitor mounted on monitor arms of the control room console. Seismic test report of bare console shall be deemed unacceptable. Seismic safety of user & control room equipment is a prime concern area. This test shall be carried out by authorised government agency. 3. Slat Wall: - Slat Wall Shall be made of approximately 2mm thick extruded aluminium (HE9WP aluminium alloy). To safeguard the desired quality of the product it is necessary that the proposed console has been tested & verified on the set of rules governing the product range. The console shall be UL Listed. 4. Modular removable PU nosing: Front edge of consoles is the component which comes in frequent contact of the operator. The soft polyurethane edge is an ergonomic requirement as per ISO 11064 (International norms for Control Room Ergonomics) and is meant to prevent injury (accidental impact) to operator during emergency and it also reduces the contact stress. In case of damage to this edge the desk design shall permit quick & easy replacement within half an hour without taking any shutdowns or removal of the table tops. To ensure zero downtime because of such maintenance. Audit certified design feature of modular PU Edge. High density poly-urethane foam moulded on industrial grade aluminium core to form 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes, in case of damage or wear without opening or removing the worktop. Extruded PU edging/PVC T-beading shall be deemed unacceptable. 5. Monitor Arm: - The Console shall feature ergonomic display mounting arms. It shall enable quick & easy replacement of VESA mounts & arm extensions as per the ergonomic requirement defined in ISO 11064. UL audit certified design feature of monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. 6. Shutters & Side Legs: - Front, back shutters shall be of 18 mm Laminated MDF Board with premium finish. Side leg shall be of 25mm of the same finish. Proposed console shall comply with the stringent/advanced version of BIFMA X7.1 standard. The console (open plan) shall not emit TVOC (A), Formaldehyde, i.e. 152 μg/m²*hr, 6.2 μg/m²*hr, respectively. This is to ensure healthier air quality for the operators. Proposed console shall be Greenguard Gold certified. No. 2.00
16 Supply of New Modular Control Desk for provision of 01 monitor & 01 Operator made in " XLAT " system. 1. Table top: - The material of the working surface shall be minimum 25 mm thick MDF with High Pressure ANSI/NEMA LD3 certified scratch-resistant laminate. The proposed console's life cycle shall be assessed (from approved LCA consultant) for environmental impacts associated with all the stages of a product's life for cradle to grave analysis. 2. Structure: Made of heavy duty extruded vertical and horizontal aluminium profiles of 6005 grade. The extrusions shall be duly powder coated with 40+ microns over all surfaces. All sheet metal parts shall be finished with a durable, black, electrostatic powder coating. To ensure that the offered product is an engineered solution. To allow future extension and expansion, a weld free system shall be proposed. Interconnecting joints shall not be visible. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 tests. The structure shall allow easy assembly of hinged shutters, slat wall, gland plate, and monitor arms in extremely rigid manner. The EPD (Environmental product declaration) of console shall be verified in accordance with ISO 14025 (from UL/Intertek) for Impacts on Environment by console. Operator consoles shall be tested and qualified to sustain seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations with monitor mounted on monitor arms of the control room console. Seismic test report of bare console shall be deemed unacceptable. Seismic safety of user & control room equipment is a prime concern area. This test shall be carried out by authorised government agency. 3. Slat Wall: - Slat Wall Shall be made of approximately 2mm thick extruded aluminium (HE9WP aluminium alloy). To safeguard the desired quality of the product it is necessary that the proposed console has been tested & verified on the set of rules governing the product range. The console shall be UL Listed. 4. Modular removable PU nosing: Front edge of consoles is the component which comes in frequent contact of the operator. The soft polyurethane edge is an ergonomic requirement as per ISO 11064 (International norms for Control Room Ergonomics) and is meant to prevent injury (accidental impact) to operator during emergency and it also reduces the contact stress. In case of damage to this edge the desk design shall permit quick & easy replacement within half an hour without taking any shutdowns or removal of the table tops. To ensure zero downtime because of such maintenance. Audit certified design feature of modular PU Edge. High density poly-urethane foam moulded on industrial grade aluminium core to form 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes, in case of damage or wear without opening or removing the worktop. Extruded PU edging/PVC T-beading shall be deemed unacceptable. Operator Console (Forensic Lab) 5. Monitor Arm: - The Console shall feature ergonomic display mounting arms. It shall enable quick & easy replacement of VESA mounts & arm extensions as per the ergonomic requirement defined in ISO 11064. UL audit certified design feature of monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. 6. Shutters & Side Legs: - Front, back shutters shall be of 18 mm Laminated MDF Board with premium finish. Side leg shall be of 25mm of the same finish. Proposed console shall comply with the stringent/advanced version of BIFMA X7.1 standard. The console (open plan) shall not emit TVOC (A), Formaldehyde, i.e. 152 μg/m²*hr, 6.2 μg/m²*hr, respectively. This is to ensure healthier air quality for the operators. Proposed console shall be Greenguard Gold certified. No. 4.00
17 Supply of Chair 1. Synchro Mechanism: The 360° swivel along with Knee Tilt Synchro mechanism with three different tilt positions, supports healthy body movements and gives great back support. 2. Mesh Back:The back is made up of injection moulded glass filled nylon & upholstered using mesh fabric with high tenacity yarn giving the perfect balance between form, functionality and comfort. 3. Adjustable Armrest:The adjustable armrest structure is powder coated and comes with 8 step adjustability. Lumbar Support:Adjustable lumbar support is provided by upholstered polypropylene pad with moulded polyurethane foam. No. 14.00
18 Scope of design 1. Detailed drawings, 2. Color options, 3. Design of ceiling, paneling & illumination of the control room Lot 1.00
19 Project Management/Supervision Charges for Installation & Commissioning for Control Room Interior Lot 1.00
Annexure-II: Technical Specifications
A) SOC ROOM (SIZE 52x22)
Sr. No. Description Remarks
A-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
A-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
A-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
A-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
A-5 Doors fire rated Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
A-6 Ceiling a. Supply of Designer Acoustic Metal False Ceiling (Make Pyrotech or equivalent) 1) Factory made acoustic modular metal false ceiling of powder coated panels. Make shall comprise of perforated and non-perforated metal panels made through CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of approved powder coating finish. Panels shall be designed to achieve shape and design as per the design consultant with the combination of acrylic panels with lights, designed to enhance visual feel, with provision for easy installation and maintenance, integrated lighting and scope for integration of building services like HVAC and fire detection/ fighting system. The designer metal ceiling shall be greenguard gold tested/certified (from UL/Intertek). Valid certificate/test report to be submitted along with the technical bid. Metal modular false ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90. 2) It is well known that metal is resistant to fire as compared to wood & fabric. However, from fire and safety point of view, to ensure that the used material is not subjected to any kind of surface treatment which provokes fire. The proposed ceiling tiles shall be Class A certified as per ASTM e84 (from UL / Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. Valid certificate/test report to be submitted along with the technical bid. 3) To ensure restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the modular metal ceiling system shall be RoHS certified (from UL / Intertek). Valid certificate/test report to be submitted along with the technical bid. 4) To avoid dark spots/areas in the control room it is necessary that continuous linear lights are used across the width/length of the control room. UL audit certified design feature of integrated channel in ceiling for quick installation & replaceability of continuous linear light: The ceiling system having integrated inbuilt channel for installation of cove lights and shall permit quick and easy replacement of cove light without using any tools. Replacement to be carried out within 120 Seconds per meter. Valid certificate/test report to be submitted along with the technical bid. 5) Seismic safety of user & control room equipment is a prime concern area. The metal ceiling shall sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations or better. The test shall be carried out by authorized government agency. Valid certificate/test report to be submitted along with the technical bid. 6) Structure shall be made from heavy duty powder coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm). It shall be securely grouted from roof with help of anchor fastener and GI self-threaded rods. It shall be formed with the help of slotted rolled W sections (stiffener) and Master C section with help of M6 cage nut and bolts.
b. Supply of Designer Calcium Silicate Ceiling Plain Calcium Silicate Acoustic Boards for false ceiling with 08mm Approximately thick, Structure for underside of suspended grid formed of GI perimeter channels. Wood screws and metal expansion raw plugs for fixing with wall. Plastic emulsion paint of approved make and shade for finishing surface of Calcium Silicate Boards. Specification: Calcium Silicate Board is manufactured from a mixture of Portland cement, fine silica, special cellulose fibers and selected fillers to impart durability, toughness, fire and moisture resistance. (Make Pyrotech or equivalent)
B) DC ROOM (SIZE 24x16)
Sr. No. Description Remarks
B-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
B-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
B-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
B-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
B-5 Doors fire rated Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
B-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
B-7 Rised floor Supplying and fixing in position antistatic raised flooring with floor panels , pedestals and stingers . The floor panel of size 600x 600x35 mm thick and made out of light weight cementitious core with steel casing on the top & bottom. It can take concentrated point load of 3.6 KN over 25mm sq. & uniformly distributed load strength (UDL) of 16 KN (1680 Kgs).The entire panel shall have an electro deposition of cathodic epoxy paint finish for lifetime protection on exposed surface.The panel shall be finished with 1.2 mm high abrasion, antistatic High Pressure Laminate in size 600mm x 600mm with 6mm beading on all sides to provide protection of edges. The Panels should be non – combustible as per BS 476, Part 4.The Pedestal of size 76 x 76 mm x 3.00 mm flat head mechanically riveted to a 75 mm long 16 mm Dia rolled formed stud and 2 check nuts for level adjustment and made out of steel, zinc plated, positively plate. Pedestal assembly shall provide for easy adjustment of levelling & accurately alignclipped to the steel top panels to ensure lateral restrain. The Pedestal Base assembly shall consist of 25.00 mm OD pipe of thickness 1.6mm mechanically locked on a press for perpendicularity and then welded to a base plate of 100 x 100 x 2mm thick with stiffening folds for an required level . The pedestal steel base plate shall be fixed onto the sub floor with epoxy adhesive & or mechanical fixing such as screws. The steel rectangular stringer of size 570x30x20 x 1 mm thick to be fixed over pedestals to give max stability and correct alignment . The work is to be completed in proper line and level as per manufacturer specifications and instructions of Engineer in charge
C) UPS ROOM (SIZE 10x12)
Sr. No. Description Remarks
C-1 Puff Partition & Puff Ceiling Providing and fixing MS structure with Insulated Roof of composite PUF panel made of Pre-painted Galvanized Iron (PPGI) corrugated sheet (0.5mm thick) on both side of puff panel (min thickness50 / max thickness 80mm) fixed on the required MS RHS structure for proper stability including paint and self thread screws for fixing and silicone and PU foam to seal all the gaps to completely seal the roof from water.PPGI Corrugated sheet made: TATA bluescope or similar.Minimum MS weight: 12.56 kg/sqft. Paint on MS structure: 1coat of redoxide primer and 2coat of enamel paint (Asian).Galvanized self tapping screws by: Patta or HP or similar .Sheet area shall be measured for payment.
C-2 Rised floor Supplying and fixing in position antistatic raised flooring with floor panels , pedestals and stingers . The floor panel of size 600x 600x35 mm thick and made out of light weight cementitious core with steel casing on the top & bottom. It can take concentrated point load of 3.6 KN over 25mm sq. & uniformly distributed load strength (UDL) of 16 KN (1680 Kgs).The entire panel shall have an electro deposition of cathodic epoxy paint finish for lifetime protection on exposed surface.The panel shall be finished with 1.2 mm high abrasion, antistatic High Pressure Laminate in size 600mm x 600mm with 6mm beading on all sides to provide protection of edges. The Panels should be non – combustible as per BS 476, Part 4.The Pedestal of size 76 x 76 mm x 3.00 mm flat head mechanically riveted to a 75 mm long 16 mm Dia rolled formed stud and 2 check nuts for level adjustment and made out of steel, zinc plated, positively plate. Pedestal assembly shall provide for easy adjustment of levelling & accurately alignclipped to the steel top panels to ensure lateral restrain. The Pedestal Base assembly shall consist of 25.00 mm OD pipe of thickness 1.6mm mechanically locked on a press for perpendicularity and then welded to a base plate of 100 x 100 x 2mm thick with stiffening folds for an required level . The pedestal steel base plate shall be fixed onto the sub floor with epoxy adhesive & or mechanical fixing such as screws. The steel rectangular stringer of size 570x30x20 x 1 mm thick to be fixed over pedestals to give max stability and correct alignment . The work is to be completed in proper line and level as per manufacturer specifications and instructions of Engineer in charge
D) FORENSIC LAB (SIZE 6x12) (Room No. 308)
D-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
D-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
D-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
D-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
D-5 Doors fire rated Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
D-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
E) GALLERY (SIZE 160x12)
E-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
E-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
c. Providing & laying RCC 1:1.5:3 including reinforcement as per sectional drawing, centering & shuttering, etc. complete
E-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
E-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
E-5 Doors fire rated glass double leaf size 3000x3300 mm Fire Resistant Glazed Sliding Door Supply and installation of tested fully glazed fire rated double leaf automatic sliding door with 120 minutes of integrity and radiation control (EW 120) and insulation for 30 minutes (EI 30) with symmetrical (Bi-Directional) fire protection. The frames shall be imported cold rolled steel sheets (As per EN standard EN 10327). The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory. The glass shall be 14mm clear 120 min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 30) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for UV resistance duration of 5000 hours. The glass shall provide bi-directional (Symmetrical) fire protection. The item shall be considered complete only when the contractor submits a certification from the manufacturer that the entire product and installation including the junctions with the surrounding civil work and partitions is of required fire rating mentioned above. The test report will be considered valid only if it contains the stamp and signature of the authorized signatory from the manufacturer. Single Unit comprising GDW1+GDW1A+GDW1 (Sliding Door Portion is 2no. shutters) Pre-approved make: Saint Gobain Vetrotech or equivalent.
E-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
E-7 Texture painting Providing and applying Premium texture paint finish on Walls, ceiling and cove painting with 3 coats of white premium acrylic emulsion of approved brand and manufacturer (pre-approved make Asian Paints Premium Emulsion) and 2 coats of special effects top coat of approved brand and manufacturer [Pre-approved Asian Paints Royale Play Dune Special Effects Paint - HALO, M609 (Silver)]. Rate to include for surface preparation including application of putty, primer and sanding as per manufacturer's specification to achieve desired effects as per Engineer-in-Charge.
F) ROOM SIZE (SIZE 15x15) Nos. 311,318,316,315
F-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
F-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
F-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
F-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
F-5 Doors fire rated glass Fire Resistant Glazed Single Leaf Door Supply and installation of tested fully glazed fire rated Latched single leaf door system with 120 minutes of integrity and radiation control (EW 120) with symmetrical (Bi-Directional) fire protection. The frames shall be imported cold rolled steel sheets (As per EN standard EN 10327). The overall door opening shall be as per tested evidence and tested as per EN 1634-1 in an accredited international laboratory. The glass shall be 14mm clear 120 min fire rated for Integrity, Radiation control (EW 120) and partially insulation (EI 30) Non Wired Toughened Interlayered glass with a light transmission of 86% and a sound reduction of 38 dB and manufactured in UL & TUV audited Facility and including UL-EU Certification and compliant to class 1(B)1 category of Impact Resistance as per EN 12600. The glass shall be tested for UV resistance duration of 5000 hours. The glass shall provide bi-directional (Symmetrical) fire protection. The item shall be considered complete only when the contractor submits a certification from the manufacturer that the entire product and installation including the junctions with the surrounding civil work and partitions is of required fire rating mentioned above. The test report will be considered valid only if it contains the stamp and signature of the authorized signatory from the manufacturer. Single unit comprising GDWB+GDWA+GDW Pre-approved make: Saint Gobain Vetrotech or equivalent.
F-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
F-7 Carpet Tile on Floor Providing and Laying of Carpet Tile (of colout and pattern as per design by architect) in flooring over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness Layer, held together with tape. Specifications of Carpet tiles shall be as follows: Size : 250mm x 1000mm Yarn Weight : 17 oz/Yd2 (580 GSM) Yarn/ Fiber : 100% Nylon 6 / 6,6 Color System : 100% Solution Dyed Nylon Pile Height Average : 4.0 - 2.5 mm (±0.5 mm) Total Thickness : 6.5mm ± 0.5mm Area of use : Commercial – Heavy Duty Backing structure - Primary : PVC with Fibreglass Electro Static Propensity : Passes AATCC-134 Installation method : Random or as specified Flammability and Safety : Passes ASTM-662 Warranty/Wear performance : 8 Years Pre-approved Model: Harrigton ETERNITY EHS1103B by Euronics. COLORS: GREY WITH BLUE. Providing and laying of Carpet tiles in skirting on walls. All specifications similar to item above.
G-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
G-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
G-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
G-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
G-5 Doors fire rated Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
G-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
H) ROOM SIZE Nos. 302 & 303 (CONFERENCE ROOM)
H-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
H-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
H-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
H-4 Paint & putty Providing and applying on walls, premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
H-5 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
H-6 Carpet Tile on Floor Providing and Laying of Carpet Tile (of colout and pattern as per design by architect) in flooring over a bed of manufacturer's approved adhesive spread evenly over the entire floor. The rate shall include cutting, trimming, fixing and clearing away of residual material to a location as directed. The rate shall also include supplying and laying of a protective layer of PVC or HDPE sheet of 50 microns thickness Layer, held together with tape. Specifications of Carpet tiles shall be as follows: Size : 250mm x 1000mm Yarn Weight : 17 oz/Yd2 (580 GSM) Yarn/ Fiber : 100% Nylon 6 / 6,6 Color System : 100% Solution Dyed Nylon Pile Height Average : 4.0 - 2.5 mm (±0.5 mm) Total Thickness : 6.5mm ± 0.5mm Area of use : Commercial – Heavy Duty Backing structure - Primary : PVC with Fibreglass Electro Static Propensity : Passes AATCC-134 Installation method : Random or as specified Flammability and Safety : Passes ASTM-662 Warranty/Wear performance : 8 Years Pre-approved Model: Harrigton ETERNITY EHS1103B by Euronics. COLORS: GREY WITH BLUE. Providing and laying of Carpet tiles in skirting on walls. All specifications similar to item above.
I) RECEPTION AREA
I-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, Iron Grills, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
I-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
I-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
I-4 Paint & putty theme based Providing and applying on walls theme based premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
I-5 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
I-6 Carpet Tile on Floor (* Vitrified Tiles size 600x600 mm), (DSR'23: 11.41.2) Providing and laying vitrified floor tiles & skirting in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR'23: 11.41.2)
I-7 12 mm Toughened Glass with theme based Single Glazed 12mm Toughened Glass Partition - With Alexa 100 Frame Profiles (with glass). Supply and Fixing of Single Glazed Glass partition of 12mm Toughened Glass using dormakaba Alexa System-100 Frames to a height of maximum 4m or as per drawing.The Fixed glass to be fixed using dormakaba Alexa BP100 Profiles at Top & Bottom & Alexa SP100 at sides. The profile size to be 100x25MM to be fixed on to the floor/wall/ ceiling as per the architect design.dormakaba Alexa H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel Alexa OHP100 Overpanel Profile to be used.In case of Open glass edges EP100 End Profile to be used. The Profile shall be matt black anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles/Frames: dormakaba Glass : Saint Giobain/Asahi
J-1 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, tiling, partitions, panelling, , internal doors, internal windows, Iron Grills, etc. The only items to be excluded are electronic equipment and any other equipment/ material that the CLIENT may wish to retain/ reuse. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
J-2 Repairing work (Minor Brickwork with plaster) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
J-3 Windows closer (With Brickwork & plaster, complete) a. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 with Cement mortar 1:6 (1 cement : 6 coarse sand)
b. 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand)
J-4 Paint & putty theme based Providing and applying on walls theme based premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including surface preparation by sanding with appropriate grade of sandpaper, filling of cracks and dents with acrylic wall putty, applying necessary coats of water based cement primer and applying minimun of two coats of paint with roller to achieve even shade and colour, all complete as per manufcaturer's instructions and to the satisfaction of the engineer-in-charge. Pre-approved make - Apcolite Advance Shyne by Asian Paints or equivalent
J-5 Doors fire rated Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
J-6 Ceiling (DSR'23, 12.53) Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
K) WASHROOM RENOVATION
K-1 Washroom Renovation 1. Dismantling and disposal of all serviceable and unserviceable material within the area demarcated in the attached drawing. These materials include false ceiling, wall tiling, Floor tiles, partitions , doors, windows, sanitary items (toilet seat, washbasin, fittings, pipes if damaged, complete, etc. Disposal of dismantled material shall include loading, transporting, unloading to approved municipal dumping ground outside property of the CLIENT. Bidders MUST visit the premises and ascertain the items and extent of demolition and disposal.
2. Providing and laying vitrified floor tiles & skirting in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR'23: 11.41.2)
3. Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
4. Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK
5. Providing and fixing white vitreous china extended wall mounting type water closet of size 595x385x385 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 liter / 6 liter ( adjustable to 2 liter / 4 liter ) including seat cover & cistern fittings nuts , bolts and gaskets etc complete . ( Make and Model : Jaquar KUS - WHT - 35951 , Flush Plate - Jaquar JCP - CHR - 352415 , Concealed Stop Cock LYR - 38083 K , Concealed Cistern Dual Flush - Euronics ECC05NA )
6. Providing and fixing White Viterous China Thin Rim Table Top Ractanguler Wash Basin Size 525x415x140 mm with 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : ( Make and Model : Jaquar JDS - WHT - 25907 N )
7. Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 620 x 370 x 315 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. ( Make and Model : Jaquar URS - WHT - 132530 , Urinal Sensor - Euronics EU 40 E )
9. Providing and fixing Single Lever Wash Basin Mixer Automatic Tap cum Auto Soap Dispenser 2 in 1 with thermostat mixer valve cutting and making good the walls wherever require : ( Make and Model : Euronics KSDT7W & Euronics HCT02 )
10. Providing and fixing CP brass 32 mm size Bottle trap of approved quality and make and as per the direction of Engineer in charge . (Make and Model : Jaquar ALD 769L 250 x 190 )
11. Providing and fixing health faucet CP flexible hose 1000 mm nozzles and swivel hook with CP brass wall flange and CP holder including cutting & making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Euronics EHF 01 )
12. Providing and fixing 15 mm dia C.P. brass angle valve for health faucet , wash basin mixer and geyser points with CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Jaquar LYR 38053 )
13. Providing and fixing Toilet Paper Holder with Mobile Holder CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Euronics EPH07P )
14. Providing and fixing Paper Towel Dispenser Stainless Steel cover plate Size 325 mm H x 325 mm W x 150 mm D CP wall flange including cutting and making good the walls wherever required complete in all respect as per direction of engineer in charge . ( Make and Model : Euronics PLUTO PPD 201 )
15. Providing & Fixing Stainless Steel type 304 towel ring 18-8 with C.P. brass round wall flanges & CP brass screws complete in all respect as per direction of engineer - in - charge . ( Make and Model : Euronics ETR 05 )
16. Providing and fixing of fully automatic "NO TOUCH" hand drier Stainless Steel Body suitable to operate on 220 volts, single phase 50 hz, A.C. power supply and directly plugged to power point complete. ( Make and Model : Euronics PLUTO PHD 501 )
17. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
18. Providing and fixing 18 mm thick gang saw cut, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade, Area of slab over 0.50 sqm
19. Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape . Size shall be actual requirement & instruction as per Engineer-in-charge.
K-2 Fire rated door for roof area Supply and installation of factory finished 120 Mins fire rated readymade door shutter – Halspan make complete as per manufacturers specifications as follows: 1) Fire Rating: 120 Min fire rated monolithic solid core door as per BS 476: Part 22:1987 with lippings of min. 6mm thick hardwood on applicable edges of door shutter fixed using PUR glue, radius to vertical edges, minimum lipping density = 640 kg/m3 2) Face Laminate / wooden veneer shall be provided on both faces as per designer's requirement. 3) Frame: Hardwood Suitable frame as per recommendation of Halspan, Density >650 kg/ m3 4) Door protection: shutter shall be protected with bubble sheet (250 GSM) protection with tape 5) Essential hardware including hinges, door closer, intumescent fire strips are included in the rate 6) Rate includes for fixing of all other hardware, fittings, etc. all complete. Drawings and details of handles and hardware are to be shared with the fire-door manufacturer at the time of placing the order and the suitable insulation medium for fixing of the hardware to conform to the required fire rating shall be provided. Pre-approved Make: Halspan core 60 mm with laminate/ veneer finish on both sides or equivalent. This item shall be considered complete when the contractor shall submit a certificate from the manufacturer than the complete door (including door frame) is installed as per manufacturer's specification and is rated for 120min fire barrier as per BS 476: Part 22:1987. Also, including 120 min Fire rated glass panel (size 300 x 300 mm) as a Vision glass and including of SS door fittings/fixtures, complete & Sizes of Door shall be as per actual requirement at site
: Attachments : General guidelines for filling up the Attachments Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 5(A), 6, 9, 10, 11, 12, 13, 15, 16, 18. 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 14 Integrity Pact: To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14.
6 Attachment 18 Safety Pact: To be submitted as per ITB Clause No. 9.3(s) and as per remarks in the Attach 18.
7 Attachment 20: Declaration of Key Managerial Person and Power of Attorney holder: Format is annexed Seperetely herewith this Volume
8 Attachment 21: Affidavit (submission of Hard Copy in ‘Original’) signed and stamped with company seal for correctness of all the information/details/data/ documentary evidences
9 Attachment 22: Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1: Format is annexed Seperetely herewith this Volume
10 Attachment 23: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1: Format is annexed Seperetely herewith this Volume
11 Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order, if applicable: Format is annexed Seperetely herewith this Volume
11 Attachment 25: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1: Format is annexed Seperetely herewith this Volume
12 Attachment-25: Bid Securing Declaration to be submitted by the Bidder.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder SOLE BIDDER
Name of Sole Bidder
Address of Sole Bidder
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-3(QR)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Qualifying Requirement Data)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
As per Annexure – A (BDS) – QR
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-QR
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Qualifying Requirement Data
Bidder’s Name and Address (Sole Bidder): To:
Contract & Material Department
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region Transmission System - I
SCO BAY 5-10, Sector-16
Faridabad-121002, Haryana
Dear Ladies and/or Gentlemen,
In support of the additional information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our details/documents etc., alongwith other information, as follows:
We are furnishing the following details/document in support of qualifying requirement for the subject package(s).
Qualification of bidder will be based on meeting the minimum pass/fail criteria specified below regarding the Bidder’s technical experience and financial position as demonstrated by the Bidder’s responses in the corresponding Bid Schedules. Technical experience and financial resources of any proposed subcontractor(s) shall not be taken into account in determining the Bidder’s compliance with the qualifying criteria. The bid can be submitted by an individual/ joint venture firm. At any stage of evaluation if any shortcoming/ discrepancy/ deficiency is observed in the documents/ details submitted by the bidder and or it is observed that the bidder is not meeting the stipulated QR, respective bid shall be summarily rejected. The owner may assess the capacity and capability of the bidder, to successfully execute the scope of work covered under the package within stipulated completion period. This assessment shall inter-alia include (i) Document verification; (ii) Bidder’s works visit (if required), (iii) Details of works executed, works in hand, anticipated in future & the balance capacity for the present scope of work; (iv) Details of plants and machinery, manpower and financial resources; (v) Details of quality system in place; (vi) past experience and performance; (vii) customers feedback; (viii) Banker’s feedback; etc.
0.0 Technical Experience:
1.1.1 The bidder should have successfully executed similar works (i.e civil works like PCC/RCC/Painting and other building works including services etc.) for Govt or Semi Govt. or reputed private Sector Organization within the last 7 years from the originally scheduled date of bid opening, as per following i. One single work/ project of a value of not less than Rs. 70.08 Lakhs (80% of estimated cost) or ii. Two works/ projects, each of a value of not less than Rs. 43.80 Lakhs (50% of estimated cost) or iii. Three works/ projects, each of a value of not less than Rs. 35.04 Lakhs (40% of estimated cost)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client Authorised Dealer/Sub dealer
5 Work Order Details Authorised Representative
Date Certificate of Authorized Dealership Submitted
Authorization of Manufacturer Submitted
6 Copy of Work order uploaded
Please upload Work Order Name of Manufacturer
7 Date of Completion of Work No
8 Completed amount for the work (Rs. Lakh) OBD 2016-01-05T00:00:00Z
7 Document submitted as Proof of Completion
Completion Cerificate No
8 Details of Document for Proof of Completion Any other document, authenticated by the client
Reference No. MAAT 127
9 Proof of Completion Uploaded Two Work
Please upload Proof of Completion
Work 2 (if any)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client
5 Work Order Details
6 Copy of Work order uploaded
Please upload Work Order
7 Date of Completion of Work
8 Completed amount for the work (Rs. Lakh)
7 Document submitted as Proof of Completion
8 Details of Document for Proof of Completion
9 Proof of Completion Uploaded
Please upload Proof of Completion
Work 3 (if any)
1 Name of the work
2 Name of the Client
3 Address of Client
4 Contact Details of Client Authorised Dealer/Sub dealer
5 Work Order Details Authorised Representative
Date Certificate of Authorized Dealership Submitted
Authorization of Manufacturer Submitted
6 Copy of Work order uploaded
Please upload Work Order Name of Manufacturer
7 Date of Completion of Work No
8 Completed amount for the work (Rs. Lakh) OBD 2016-01-05T00:00:00Z
7 Document submitted as Proof of Completion
Completion Cerificate No
8 Details of Document for Proof of Completion Any other document, authenticated by the client
Reference No. MAAT 127
9 Proof of Completion Uploaded Two Work
Please upload Proof of Completion
0.9 Financial position
Minimum Average Annual Turnover (MAAT)* of the bidder should be Rs. 131.41 Lakhs for best three financial years out of last five financial years commencing from Financial Year 2017-18. *Note: - Annual Gross revenue from operations/ gross operating income as incorporated in the profit & loss account excluding other income.
Performance Report from Client
Acceptance of Final Bill by Client
Sr. No. Financial Year Turnover (in Rs. Lakh) Copy of Balance Sheet & P/L Account Uploaded Certificate from CA
a 2017-18 Any Other (Please Specify)
Average Turnover for Best Three Years
The bidder shall furnish following documents/details with its bid a) The bidder shall submit documents in support of meeting the technical experience mentioned at Para 1.1 above in the form of LOA/ Work order & completion certificate/payment certificate or any other document evidencing the same. b) The bidder shall submit audited / certified copies of Balance Sheet and Profit and Loss account in support of meeting the financial position as mentioned at Para 1.2 . Note-I : In the event the bidder is not able to furnish the information of its own (i.e., separate), being a subsidiary company and its accounts are being consolidated with its group/ holding/ parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/ holding/ parent company) duly certified by any one of the authority [(i) Statutory Auditor of the bidder or (ii) Company Secretary of the bidder certifying that such information / documents are based on the audited accounts as the case may be). Note II: Similarly, if the bidder happens to be group/ holding/ parent company, the bidder should submit the above documents/ information of its own (i.e., exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/ documents are based on the audited accounts as the case may be.
Relaxation for MSEs/ STARTUPS MSEs^/ START-UPs^^ meeting the necessary requirements shall also be considered qualified if they meet 80% (Eighty percent) of the requirements of Minimum Average Annual financial turnover (MAAT ) for the best three financial years out of the last five financial years as above. ^MSEs as defined in bidding documents. ^^START-Ups as defined by DIPP, applicable as on the originally scheduled date of bid
1 Copy of PAN Card Uploaded
Please upload Copy of PAN Card
1.1 PAN Card Number
2 Status of the Bidder
3 MOA & AOA/ Certificate of Incorporation Uploaded
Please upload Copy of Relevent Document
Date : Printed Name :
Place : Designation :
Private Limited Company
Public Limited Company
Affidavit of Proprietorship Uploaded
Parnership Deed Uploaded
MOA & AOA/ Certificate of Incorporation Uploaded
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-4
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries],
country. country. [Name of Countries], [Name of Countries],
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Attachment-4(A)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Attachment-4(B)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-5
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/ sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract (if any) without the prior approval of Employer.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-5(A)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy / avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package.
Sl. No. Item Description Quantity Proposed to be bought / sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms & Procedures, Volume-Iof Bidding Documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Annexure I to
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-9
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Work Completion Schedule)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
1 Detailed Engineering and drawing submission Shall be as per Delivery Schedule (Completion Period) given in SCC. Hence Not Required to be Filled here.
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-11
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We declare that we are aware of and have gone through the "Code of Business Conduct and Ethics for Senior Management Personnel" and "Code of Business Conduct and Ethics for Board Members" of POWERGRID (hereinafter referred to as the "Code of Conduct"). We further understand that as per the "Code of Conduct", Senior Management Personnel including Board Members, who have retired / resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred "Code of Conduct", within 1 year from the date of cessation of service / directorship unless approved by the Competent Authority.
Accordingly, We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder's organization of such ex-employee is within 1 year from the date of retirement / resignation from POWERGRID, No Objection Certificate / approval from the Competent Authority must be furnished alongwith the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate / approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and Procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard.
We further declare that any misrepresentation or submission of false / forged documenmts / information in this regard shall be dealt with as per the provisions of the Integrity Pact and / or the Bidding Documents and / or POWERGRID's policy and procedure.
Date : Printed Name :
Place : Designation :
1. "Code of Business Conduct and Ethics for Senior Management Personnel" and "Code of Business Conduct and Ethics for Board Members" are available on POWERGRID's website http://www.powergridindia.com.
2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid.
3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated '-' against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We hereby confirm that the prices of Services offered by us will remain FIXED & FIRM during the performance of the contract and will not subject to any variation on any account.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Attachment 14 Integrity Pact: To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion: NOT APPLICABLE No
Services Portion: NOT APPLICABLE No
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1 Name of the Supplier/ Contractor in whose favour payment is to be made
2 Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order [Indicate Yes / No]
Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment.
3. (c) If 3(b) is 'Yes' please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order [Indicate Yes / No]
Note: Documentary evidence is to be attached.
4 Permanent Account (PAN) No.
5 GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
9 PF Registration No. of the Company
10 PF Regional Office covered (with Address)
11 Name of Contact Person
12 Contact Details
13 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account: Saving Account
14 9 digit MICR code printed at bottom in middle, next to cheque no.
15 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Remarks: The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC/ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited Companies, at least 51% share shall be held by SC/ST promoters.
Documentary Evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-16
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Additional Information)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
0.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Bidder (Sole Bidder)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
0.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years
Year Name of client Details of Transgression of Integrity Pact by the bidder
0.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Total Liability
Current Liability
Profit before taxes
Profit after taxes
4.3 Provident Fund Code Number of the Bidder:
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-17
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-17
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Materials dept.
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. Northern Region–I, Regional Headquarter,
…… ……. …….. …… ……. …….. SCO Bay No. 5 to 10, Sector 16A,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : Printed Name :
Place : Designation : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Attachment-17
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : Printed Name :
Place : Designation : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Attachment 18 Safety Pact: To be submitted as per ITB Clause No. 9.3(s) and as per remarks in the Attach 18.
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP.
Bidder’s Name and Address (Sole Bidder): To:
Contracts & Materials dept.
Name : Power Grid Corporation of India Ltd.,
Address : Northern Region–I, Regional Headquarter,
SCO Bay No. 5 to 10, Sector 16A,
Faridabad-121002, Haryana
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440) Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No.: 5 five 5 th 5 May
Date: 6 six 6 th 6 June
7 seven 7 th 7 July
To: 8 eight 8 th 8 August
Contracts & Materials dept. 9 nine 9 th 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Northern Region–I, Regional Headquarter, 11 eleven 11 th 11 November
SCO Bay No. 5 to 10, Sector 16A, 12 twelve 12 th 12 December
Faridabad-121002, Haryana 13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
0.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in single envelope. ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in single envelope. 17 seventeen 17 th
0.0 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
0.0 Attachments to the Bid Form Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(a) Attachment 1: Bid Security Bank Guarantee INR Banks certified Cheque Zero 20 twenty 20 th
(b) Attachment 2 : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 07 (seven) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3 (QR) & Attach QR: The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). FDR 22 th
SOLE BIDDER CDR/TDR Applicable 23 th
(d) Attachment 4, 4A & 4B : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 0 Not Applicable 24 th
(e) Attachment 5 : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 25 th
(f) Attachment 5(A) : The details of the items, components, raw materials, services which we propose to buy / avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package in case of award, giving details of the name and category of the proposed Micro and Small Enterprises (MSEs).
(g) Attachment 6 : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 26 th
(h) Attachment 7 : NOT APPLICABLE The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 27 th
(i) Attachment 8 : NOT APPLICABLE Manufacturer’s Authorisation Forms. 28 th
(j) Attachment 9 : Work Completion Schedule. 29 th
(k) Attachment 10 : Guarantee Declaration. 30 th
(l) Attachment 11 : Information regarding ex-employees of Employer in our firm. 31 st
(m) Attachment 12 : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13 : Declaration regarding Social Accountability.
(o) Attachment 14 : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15 : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16 : Additional Information.
(r) Attachment 17 : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18 : Safety Pact
(t) Attachment 19 : Declaration.
(u) Attachment 20 : Declaration of Key Managerial Person jointly with Power of Attorney Holder
(v) Attachment 21 : Affidavit (submission of Hard Copy in ‘Original’) signed and stamped with company seal by a full time Director/ CEO/ Chairman-cum-Managing Director
(w) Attachment 22: Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1
(y) Attachment 24: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1
(x) Attachment 23: Certification by the Bidder per order no. F.No.6/18/ 2019-PPD dated 23/07/2020 issued by Public Procurement Division
(y) Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order, if applicable
0.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
0.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
0.9 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
0.9 We also understand that, in case of award on us, you shall pay directly, if so required /reimburse to us octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items, which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit). Further, Service Tax, if applicable, for the services to be rendered by us, the same is included in our bid price in Second Envelope.
0.0 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
0.0 We confirm that no Sales Tax/VAT in any form shall be payable by you for the bought out items which shall be despatched directly by us under the First Contract (as referred in para 5.1 below) [or Letter of Award, if 5.1 Not applicable] to the project site. However, you will issue requisite Sales Tax declaration/Vatable forms in respect of such bought out items, on production of documentary evidence of registration with the concerned Sales Tax Authorities.
0.0 Construction of the Contract
0.9 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
0.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 55.0 Terms of Payment
(d) GCC 8.3 Performance Security
(e) GCC 6.0 Taxes and Duties
(f) GCC 38.0 Liquidated Damages for Delay by Contractor
(g) GCC 39.0 Guarantee
(h) GCC 40.0 Defect Liability
(i) GCC 20.5 Patents and Royalties
(j) GCC 61.0 Limitation of Liability
(k) GCC 57.0 Settlement of Disputes
(l) GCC 59.0 Arbitration
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
0.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award/Letter of Award/Work Order to us, and to achieve the completion within the time stated in the Bidding Documents.
0.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
0.0 We agree to abide by this bid for a period of 180 (One Hundred Eighty) days from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
0.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
0.0 We understand that you are not bound to accept the lowest or any bid you may receive.
0.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
0.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
0.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (Specification No.:NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx: 5002003440)) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Checklist for Bid Submission
1 Soft copy of First Envelope Bid Form Duly Filled Excel Sheet of Attachment and Bid Form to be uploaded in Soft Copy along with Bid. To be submitted in Soft Copy.
2 Power of Attorney (POA) Duly notarized (on Stamp Paper of requisite value), indicating that the person(s) signing the bid has(ve) the authority to sign the bid. In case of bid submitted by a Joint Venture of two or more firms as partners, if allowed as per stipulated Qualification Requirements in Annexure-A (BDS), bidder shall submit. Power of Attorney for Joint Venture and Joint Venture Agreement as per given format Submission of Hard copy in ‘Original’and uploading of Scanned Copy
3 MSE Status Certificate (if applicable) Udyam Registration Certificate and certificate for Registration under category of Micro/Small enterpises. Submission of Hard copy and uploading of Scanned Copy
4 Bid Security The bid security shall, at the bidder’s option, be in the form of a crossed bank draft in favour of POWERGRID or a bank guarantee from a reputed bank selected by the bidder. Alternatively, same can be submitted as online payment through POWERGRID ONLINE PAYMENT UTILITY- https://epay.powergrid.in, a link of which is provided on the POWERGRID website www.powergridindia.com. The copy of ‘Online Payment Acknowledgement – Suppliers’ generated subsequent to the payment shall be submitted along with hard copy part of the bid. The format of the bank guarantee shall be in accordance with the form of bid security included in the Bidding Documents. Bid security shall be valid upto 250 days from the date of Bid Opening. The Bid Security shall be in favour of Power Grid Corporation of India Limited payable at New Delhi. Submission of Hard copy and uploading of Scanned Copy
5 Bidding Document Fee Bid document cost for amount as specified in BDS- Hard copy of document related to online payment of bid document cost as indicated in BDS or Exemption certificate to be submitted along with hard copy part of bid. Copy of the payment proof may be uploaded online on the portal. Submission of Hard copy and uploading of Scanned Copy
6 Attachment-8: Manufacturers Authorization Form Not applicable
7 Attachment-14: Integrity Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
8 Attachment-18: Safety Pact To be submitted on a non-judicial stamp paper of Rs. 100/-. (in two originals, Signed on each page by Power of Attorney Holder and duly witnessed) Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
9 Attachment 20: Declaration of Key Managerial Person jointly with Power of Attorney holder Signed by CEO/Managing Director/Company Secretary/ Director/ CFO/ any of the partner in case of partnership firm/ any other officer entrusted with substantial powers of the management of the affairs of the company/firm and POA Holder To be submitted in Soft Copy.
10 Attachment-21: Affidavit regarding correctness of Information To be submitted on Firm/Company's Letterhead. Signed and stamped with company seal by a full time Director/ CEO/ Chairman-cum-Managing Director and attested/ notarized by a Magistrate/ Notary for correctness of all the information/details/data/ documentary evidences etc. as submitted by the bidder are correct. To be submitted in Soft Copy.
11 Attachment-22: Declaration by the bidder regarding events encountered pursuant to ITB Clause 2.1. (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) On Firm/Company's Letterhead To be submitted in Soft Copy.
12 Attachment-23: Certification by the Bidder as per order no. F.No.6/18/2019-PPD dated 23/07/2020 issued by Public Procurement Division, Department of Expenditure, Ministry of Finance, Government of India (DoE Order) in line with ITB 2.1 (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) On Firm/Company's Letterhead To be submitted in Soft Copy.
13 Attachment 24: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII Order and MoP Order (In case of a Joint Venture bid, the declaration shall be given by all partners of the Joint Venture) To be submitted on a non-judicial stamp paper of Rs. 100/-. Submission of Hard copy in ‘Original’ and uploading of Scanned Copy
14 Attachment 25: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order and MoP Order. Not applicable
15 Documents for Qualifying Requirement (QR) In support of meeting the qualifying requirements (QR) such as copy of letter of award/ work order, completion certificate, copy of audited balance sheet for five years etc., shall be uploaded by the bidder along on the portal as part of technical bid To be submitted in Soft Copy.
NOTE: This checklist is not exhaustive and issued for the purpose of reference Only. In case of any ambiguity, the provisions of Bidding Documents shall prevail.
Package Name Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
Package Code RFX-5002003440
Specification No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
1 Fill up only green shaded cells in Sch-3 and Sch-Discount (if any) and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-4b (Maintenance Charges during and after Defect Liability Period) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Sole Bidder 1 Sole Bidder 1
Joint Venture 2 or More JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Sole Bidder Sole Bidder 1 0 Sole Bidder 1 0
Name of Sole Bidder …….. …….. …….. …….. …….. ……..
Address of Sole Bidder …….. …….. …….. …….. …….. ……..
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
PLANT AND EQUIPMENT (INCLUDING MANDATORY SPARES PARTS) TO BE SUPPLIED, INCLUDING TYPE TEST CHARGES FOR TESTS TO BE CONDUCTED Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘ 6 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST Tax as confirmed by Bidder
PART A (Substation Portion)
I Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 28 Included 0.00 0 0.00
23 28 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
II Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
III Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
5 18 Included 0.00 0 0.00
6 18 Included 0.00 0 0.00
7 18 Included 0.00 0 0.00
8 18 Included 0.00 0 0.00
9 18 Included 0.00 0 0.00
10 18 Included 0.00 0 0.00
11 18 Included 0.00 0 0.00
12 18 Included 0.00 0 0.00
13 18 Included 0.00 0 0.00
14 18 Included 0.00 0 0.00
15 18 Included 0.00 0 0.00
16 18 Included 0.00 0 0.00
17 18 Included 0.00 0 0.00
18 18 Included 0.00 0 0.00
19 18 Included 0.00 0 0.00
20 18 Included 0.00 0 0.00
21 18 Included 0.00 0 0.00
22 18 Included 0.00 0 0.00
23 18 Included 0.00 0 0.00
24 18 Included 0.00 0 0.00
25 18 Included 0.00 0 0.00
26 18 Included 0.00 0 0.00
27 18 Included 0.00 0 0.00
28 18 Included 0.00 0 0.00
29 18 Included 0.00 0 0.00
30 18 Included 0.00 0 0.00
31 18 Included 0.00 0 0.00
32 18 Included 0.00 0 0.00
33 18 Included 0.00 0 0.00
34 18 Included 0.00 0 0.00
35 18 Included 0.00 0 0.00
36 18 Included 0.00 0 0.00
37 18 Included 0.00 0 0.00
38 18 Included 0.00 0 0.00
39 18 Included 0.00 0 0.00
40 18 Included 0.00 0 0.00
41 18 Included 0.00 0 0.00
42 18 Included 0.00 0 0.00
43 18 Included 0.00 0 0.00
44 18 Included 0.00 0 0.00
45 18 Included 0.00 0 0.00
46 18 Included 0.00 0 0.00
47 18 Included 0.00 0 0.00
48 18 Included 0.00 0 0.00
49 18 Included 0.00 0 0.00
50 18 Included 0.00 0 0.00
51 18 Included 0.00 0 0.00
52 18 Included 0.00 0 0.00
53 18 Included 0.00 0 0.00
54 18 Included 0.00 0 0.00
55 18 Included 0.00 0 0.00
56 18 Included 0.00 0 0.00
57 18 Included 0.00 0 0.00
58 18 Included 0.00 0 0.00
59 18 Included 0.00 0 0.00
60 18 Included 0.00 0 0.00
61 18 Included 0.00 0 0.00
62 18 Included 0.00 0 0.00
63 18 Included 0.00 0 0.00
64 18 Included 0.00 0 0.00
65 18 Included 0.00 0 0.00
66 18 Included 0.00 0 0.00
67 18 Included 0.00 0 0.00
68 18 Included 0.00 0 0.00
69 18 Included 0.00 0 0.00
70 18 Included 0.00 0 0.00
71 18 Included 0.00 0 0.00
72 18 Included 0.00 0 0.00
73 18 Included 0.00 0 0.00
74 18 Included 0.00 0 0.00
75 18 Included 0.00 0 0.00
76 18 Included 0.00 0 0.00
77 18 Included 0.00 0 0.00
78 18 Included 0.00 0 0.00
79 18 Included 0.00 0 0.00
80 18 Included 0.00 0 0.00
81 18 Included 0.00 0 0.00
82 18 Included 0.00 0 0.00
83 18 Included 0.00 0 0.00
84 18 Included 0.00 0 0.00
85 18 Included 0.00 0 0.00
86 18 Included 0.00 0 0.00
87 18 Included 0.00 0 0.00
88 18 Included 0.00 0 0.00
89 18 Included 0.00 0 0.00
90 18 Included 0.00 0 0.00
91 18 Included 0.00 0 0.00
92 18 Included 0.00 0 0.00
93 18 Included 0.00 0 0.00
94 18 Included 0.00 0 0.00
95 18 Included 0.00 0 0.00
96 18 Included 0.00 0 0.00
97 18 Included 0.00 0 0.00
98 18 Included 0.00 0 0.00
99 18 Included 0.00 0 0.00
IV Revaluation of J column Tax Calculation
1 18 Included 0.00 0 0.00
2 18 Included 0.00 0 0.00
3 18 Included 0.00 0 0.00
4 18 Included 0.00 0 0.00
Total Ex-works Price 0.00 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 1 Direct Total 0 Sole Bidder `
BO Total #REF! 0
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 2
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
LOCAL TRANSPORTATION, IN-TRANSIT INSURANCE, LOADING AND UNLOADING
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges
PART A (Substation Portion)
Total F&I Price 0.00
Place: Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 2 Dis
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 3
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
CIVIL & ELECTRICAL WORKS Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
PART A (Substation Portion)
ELECTRICAL WORKS Revaluation of J column Tax Calculation
1 18 SUPPLYING AND ERECTING MAIN LT PANEL. Nos 1 Included 0.00 0 0
2 Supply ,Erection, Testing and commissioning of 250A Main LT Panel front and back operated, totally enclosed ,bottom cable entry, outdoor dust and vermin proof IP 44 cubicle floor mounting fabricated in standard sections, base frame, compartmentalised construction fabricated out of 2mm thick CRCA sheets with powder coated Siemens gray paint RAL 7035 after seven tank treatment, having gasketed & hinged cover on each cubicle with door lock facility, incorporating horizontal & vertical Aluminium busbars and clearance between phase, neutral and earth minimum 25mm distance, heat shrinkable colour coded PVC sleeves throughout the bus bars, complete with all internal wiring, earthing bus and lugs, cable chamber, busbar chamber, PVC name plates, illumination lamps as required as per the requirement with approved GA drawing. Bus bar 200A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped. The Panel shall comprise 2 Nos of incoming 160A MCCB & outgoing termination leads with common bus bar and its accessories as follows, busbar chamber interconnections suitable for mounting arrangements. 0 0
3 INCOMER SECTION: 0 0
4 250A, 36kA 4P MCCB LSIG - 2 Sets with manual interlocking. 0 0
5 OUT GOING SECTION: 0 0
6 32A 3P MCCB - 08Nos 0 0
7 63A 3P MCCB - 10Nos 0 0
9 250A 4P ATS with necessary wiring with controllers. 0 0
10 METERING SECTION: 0 0
11 Multifunction meter capable of reading various parameters like V,A,F,PF,W,VAR,etc including THD measurement with suitable communication port - 1 Set. 0 0
12 CT - 250/5A CL.1 15VA CT - 1 Sets 0 0
13 BUSBARS : 0 0
14 Bus bar 500A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped. 0 0
17 SPD - OBO /Legrand/Schneider 3xMCD50B+1xMCD125B+V20/3FS/Equivalent approved - 1 Sets 0 0
18 18 SUPPLYING AND ERECTING UPS OUTPUT PANEL. Nos 3 Included 0.00 0 0
19 Supply ,Erection, Testing and commissioning of 63A UPS Output Panel front and back operated, totally enclosed ,bottom cable entry, outdoor dust and vermin proof IP 44 cubicle floor mounting fabricated in standard sections, base frame, compartmentalised construction fabricated out of 2mm thick CRCA sheets with powder coated Siemens gray paint RAL 7035 after seven tank treatment, having gasketed & hinged cover on each cubicle with door lock facility, incorporating horizontal & vertical Aluminum busbars and clearance between phase, neutrel and earth minimum 25mm distance, heat shrinkable colour coded PVC sleeves throughout the bus bars, complete with all internal wiring, earthing bus and lugs, cable chamber, busbar chamber, PVC name plates, illumination lamps as required as per the requirement with approved GA drawing. Bus bar 1600A TP+N aluminium of equal size in all phases and neutral reinforced angle iron frame work equipped. The Panel shall comprise 3 Nos of incoming 630A MCCB & outgoing termination leads with common bus bar and its accessories as follows, busbar chamber interconnections suitable for mounting arrangements. 0 0
20 INCOMER SECTION: 0 0
21 63A, 15kA 4P MCCB LSIG - 1 Set. 0 0
22 OUT GOING SECTION: 0 0
23 32A 4P MCB - 04Nos 0 0
24 32A DP MCB - 6Nos 0 0
25 METERING SECTION: 0 0
26 Multifunction meter capable of reading various parameters like V,A,F,PF,W,VAR,etc including THD measurement with suitable communication port - 1 Set. 0 0
27 CT - 63/5A CL.1 15VA CT - 1 Sets 0 0
28 BUSBARS : 0 0
29 Bus bar 125A TP+2N Cu. with reinforced angle iron frame work equipped. 0 0
30 18 Supply and installation of UPS Out put Power Distribution wall mounted DB for 25 numbers work station with provision 63A 4 Pole MCB as incomer and sheet metal fabricated, powder coated, having dust and vermin 'proof, gasketed and hinged door, neutral-link, interconnected wiring complete with earthing housing following switchgears: (IP-43) Nos 2 Included 0.00 0 0
31 INCOMER SECTION: 0 0
32 63A 4Pole D Curve MCB - 1No. 0 0
33 OUTGOING SECTION: 0 0
34 16A 2Pole D Curve MCB - 3No. 0 0
35 10A SP D Curve MCB - 20No. 0 0
36 18 Supply and installation of ELDB and UPS UDB wall mounted type with provision 63A 2 Pole MCB as incomer and sheet metal fabricated, powder coated, having dust and vermin 'proof, gasketed and hinged door, neutral-link, interconnected wiring complete with earthing housing following switchgears: (IP-43) Nos 2 Included 0.00 0 0
37 INCOMER SECTION: 0 0
38 63A 2Pole C Curve MCB - 1No. 0 0
39 OUTGOING SECTION: 0 0
40 10A Single Pole D Curve MCB - 16 Nos. 0 0
41 18 Supply,Erection, testing, and commissioning of the wall mounted powder coated Lighting Distribution Board-TPN Flexi Tier DB manufactured with CRCA sheet, vermin proof, dust proof, indoor duty, front door for access, lighting panel board for server hall. Distribution board will have metal casing with double door and shall be fabricated as mentioned and shall have lockable front door & this lock shall be flushed with main door with common key for all DBs. Nos 2 Included 0.00 0 0
42 Incomer : 63A 4P MCB -1 No 0 0
43 Sub-Incomer : 40A DP MCB -3 Nos 0 0
44 Outgoings : 10A SP MCB – 30Nos 0 0
45 Blank plate : 6 Nos 0 0
46 18 Supply,Erection, testing, and commissioning of the wall mounted powder coated Power Distribution Board-TPN Flexi Tier DB manufactured with CRCA sheet, vermin proof, dust proof, indoor duty, front door for access, lighting panel board for server hall. Distribution board will have metal casing with double door and shall be fabricated as mentioned and shall have lockable front door & this lock shall be flushed with main door with common key for all DBs. Nos 2 Included 0.00 0 0
47 Incomer : 63A 4P MCB -1 No 0 0
48 Sub-Incomer : 40A DP MCB -3 Nos 0 0
49 Outgoings : 20A SP MCB – 15Nos 0 0
50 Outgoings : 10A SP MCB – 15Nos 0 0
51 Blank plate : 6 Nos 0 0
52 LT CABLES 0 0
53 18 Supply Laying, Testing & Commissioning of 1C x 10Sq.mm Copper flexible cable. Mtr 400 Included 0.00 0 0
54 18 Supply Laying, Testing & Commissioning of 4C x 70 Sq.mm Aluminum armoured cable. Mtr 300 Included 0.00 0 0
55 18 Supply Laying, Testing & Commissioning of 4C x 16 Sq.mm Copper flexible cable. Mtr 200 Included 0.00 0 0
56 18 Supply Laying, Testing & Commissioning of 4C x 10 Sq.mm Copper flexible cable. Mtr 500 Included 0.00 0 0
57 18 Supply Laying, Testing & Commissioning of 4Cx6 sq.mm Cu.Flex.Cable Mtr 320 Included 0.00 0 0
58 18 Supply Laying, Testing & Commissioning of 1Cx16 sq.mm Cu.Flex.Cable - Green Rack Earthing Mtr 100 Included 0.00 0 0
59 18 Supply Laying, Testing & Commissioning of 1Cx6 sq.mm Cu.Flex.Cable - Green Stud Earthing Mtr 200 Included 0.00 0 0
60 18 Supply Laying, Testing & Commissioning of 3Cx1.5 sq.mm Cu.Flex.Cable - Lighting. Mtr 400 Included 0.00 0 0
61 CABLE END TERMINATION 0 0
62 Supply and Installation of non-metallic cable glands (PVC /Rubber) for single/multi core flexible, non-armoured cables, including crimping type aluminium/copper lugs, paste, insulation tape, heat shrinkable R, Y, B, color PVC sleeves (in case of black color cables) for phase identification, hardware, consumables, fixing of permanent cable identification tags etc. as required in following sizes. The lugs shall be aluminium or copper respectively for aluminium or copper cables. Proper size of identification ferrules to be provided in all cables. 0 0
63 18 Supply Laying, Testing & Commissioning of 1C x 10Sq.mm Copper flexible cable. Nos 16 Included 0.00 0 0
64 18 Supply Laying, Testing & Commissioning of 4C x 70 Sq.mm Aluminum armoured cable. Nos 4 Included 0.00 0 0
65 18 Supply Laying, Testing & Commissioning of 4C x 16 Sq.mm Copper flexible cable. Nos 8 Included 0.00 0 0
66 18 Supply Laying, Testing & Commissioning of 4C x 10 Sq.mm Copper flexible cable. Nos 4 Included 0.00 0 0
67 18 Supply Laying, Testing & Commissioning of 4Cx6 sq.mm Cu.Flex.Cable Nos 4 Included 0.00 0 0
68 18 Supply Laying, Testing & Commissioning of 1Cx16 sq.mm Cu.Flex.Cable - Green Rack Earthing Nos 16 Included 0.00 0 0
69 18 Supply Laying, Testing & Commissioning of 1Cx6 sq.mm Cu.Flex.Cable - Green Stud Earthing Nos 32 Included 0.00 0 0
70 18 Supply Laying, Testing & Commissioning of 3Cx1.5 sq.mm Cu.Flex.Cable - Lighting. Nos 60 Included 0.00 0 0
71 18 Supply and Installation of 200x50x1.6mm MS powder coated White colour perforated type cable tray with coupling accessories.(Rack power) Mtr 50 Included 0.00 0 0
72 18 Supplying and erecting of box type trunking LV Tray 300 mm Wide x 50mm Deep x 2 mm Thick with divider pre-fabricated in factory with cover but with a central divider panel, for flooruse of any anchor-fastners etc. The cost to also include all required pre-fabricated bends, tees, crosses and including the necessary arrangement. Mtr 100 Included 0.00 0 0
73 18 Supplying and erecting of box type trunking LV Tray 150 mm Wide x 50mm Deep x 2 mm Thick with divider pre-fabricated in factory with cover but with a central divider panel, for flooruse of any anchor-fastners etc. The cost to also include all required pre-fabricated bends, tees, crosses and including the necessary arrangement. Mtr 150 Included 0.00 0 0
74 18 Supply, installation, testing and commissioning of power points by providing following switches/sockets mounted on suitable size metal /pvc boxes fixed flush/surface on to the wall with all Installation and wiring accessories 1x10/20 Amps,(230 Volts) single phase twin socket with 1x20 Amps single way switch with indicating lamp. Plug tops are excluded from the scope of supply. (Raw /UPS power Sockets) Each 82 Included 0.00 0 0
75 18 Supply, installation, testing and commissioning of power points by providing following with 25 mm PVC conduit and 2R x 2.5 sq.mm + 1R x 2.5 sq.mm wires fixed flush/surface on to the wall with all Installation and wiring accessories. Mtr. 1200 Included 0.00 0 0
76 18 Supply & Installation of Copper plate 600x600x3mm Earthing system - 48 mm Diameter water charging, wall thickness 1.2mm,with all accessories. As per is 3043 IS code Each 4 Included 0.00 0 0
77 18 Supply & Installation of GI plate 600x600x6mm Earthing system - 48 mm Diameter water charging, wall thickness 1.2mm,with all accessories. As per is 3043 IS code Each 4 Included 0.00 0 0
78 18 Supply and erecting 25 x 3mm cu.earthing flat with necessary drilling,cutting and hardware with double washer etc as per the requirements. Mtr 460 Included 0.00 0 0
79 18 Supply and erecting 25 x 5mm GI.earthing flat with necessary drilling,cutting and hardware with double washer etc as per the requirements. Mtr 600 Included 0.00 0 0
80 18 Supplying and erecting Tinned Copper Earth Bus Bar of size 40 x 6 x 300mm long with suitable MS fabricated bus bar box with green powder coated painting as required. Each 4 Included 0.00 0 0
81 18 Supply & Installation of LED based Continuous/single piece Light fitting 600 mm x 600 mm to be ceiling suspending from LV cable trays having integral driver with diffuser. The fitting should be complete with all necessary hardware required for suspending from ceiling or for fixing directly below the cable trays. Each 75 Included 0.00 0 0
82 18 LED base decorative EXIT light suspended from ceiling Each 20 Included 0.00 0 0
83 18 Supply & Installation of Occupancy Sensor capable of sensing small movements Passive Infrared Dual Lens or Ultrasonic or Microwave)mounted on the ceiling and wired through the lighting circuitfor automatic control of the lights. The sensor should have a minimum sensing range of 7.5 meter diameter and rated at 10 A with built-in adustable time delay up to 10 minutes.The sensor should also have adustable light level sensitivity for control through ambient lighting. Each 8 Included 0.00 0 0
84 18 Providing UPS power point wiring for work stations and security table with 25mm conduit and 1.5Sq.mm. copper flexible cable including 3Nos x 5 pin socket + 1x 10A switch. Nos 45 Included 0.00 0 0
85 18 Providing Data and Voice dual face plate of RJ45 and RJ11. Nos 60 Included 0.00 0 0
86 18 Supplying and laying 1mt x 10mt x 2mm thick ISI marked rubber mats to be laid in front of the panel boards. Sq.Mtr. 4 Included 0.00 0 0
HVAC Revaluation of J column Tax Calculation
1 Part "A" (High Side) 0 0
2 Supply of Outdoor Units- VRV-X System Make- DAIKIN or equivalent HEATING & COOLING (R410A) Supply of Modular type outdoor units equipped with highly efficient scroll compressors with 100% inverter technology type compessors special heat exchanger, low noise condenser fan , auto check function for connection error, auto address setting and The condensing unist shall be sutaible for operation on 415+ 10% Volts , 50 Hz, 3 phase A.C power supply & Condensing units capacity as mentioned below 0 0
3 28 ODU -34 HP Heating & Cooling Top Discharge No. 1 Included 0.00 0 0
4 28 ODU -36 HP Heating & Cooling Top Discharge No. 1 Included 0.00 0 0
5 Indoor Units 0 0
6 Supply of Indoor units address setting & capacity as mentioned below. multispeed motor, coil section with DX coil, outer cabinet, drain pan, drain water lift-up mechanism insulation, pipe connections etc. 0 0
7 28 3.3 Ton 4- Way Cassette Units - with Panel Nos. 3 Included 0.00 0 0
8 28 1.65 Ton 4- Way Cassette Units - with Panel Nos. 2 Included 0.00 0 0
9 28 Hi wall - 2.08 Nos. 5 Included 0.00 0 0
10 28 Hi wall - 1.65 Nos. 17 Included 0.00 0 0
11 28 Refrigerent joint Nos. 25 Included 0.00 0 0
12 28 Cordless Remote Nos. 27 Included 0.00 0 0
13 Non - VRV 0 0
14 28 Split - 1.8 Tr Non-Inverter Nos 4 Included 0.00 0 0
15 Part "B" (Low Side Work) 0 0
16 VRV System 0 0
17 18 Lifting, shifting, positioning, installation of complete System comprising of 2Nos. of Outdoor unit & 27 nos of indoor unit. 0 0
18 Outdoor Unit 0 0
19 18 ODU -34 HP Heating & Cooling Top Discharge No. 1 Included 0.00 0 0
20 18 ODU -36 HP Heating & Cooling Top Discharge No. 1 Included 0.00 0 0
#REF! Indoor Units 0 0
#REF! 18 3.3 Ton Cassette Units - 4 Way Nos. 5 Included 0.00 0 0
#REF! 18 1.65 Ton 4- Way Cassette Units - with Panel Nos. 2 Included 0.00 0 0
#REF! 18 Installation Of Hi- wall Nos. 22 Included 0.00 0 0
#REF! 18 Dismentalling Of Old split a.c Nos. 28 Included 0.00 0 0
#REF! 18 Refrigerent joint Nos. 25 Included 0.00 0 0
#REF! 18 Cordless Remote Nos. 27 Included 0.00 0 0
#REF! 18 Testing, Commissioning of complete System comprising of 2 no of Outdoor unit & 27 nos of indoor unit . Ckt 2 Included 0.00 0 0
#REF! Refrigerant piping 0 0
#REF! 18 Inter-connecting refrigerant pipe work with (19mm/13mm thick) closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with MS chanell / hangar. 0 0
#REF! 18 Pair of refregration duly insulated with 19/13mm nitrile rubber RMT 185 Included 0.00 0 0
#REF! Control & Transmission wire 0 0
#REF! 18 2 Core x 1.5 Sq mm copper in suitable conduits between indoor & outdoor unit. RMT 215 Included 0.00 0 0
#REF! 18 3 Core x 2.5 Sq mm copper flexible wire to connect indoor units from power point. RMT 15 Included 0.00 0 0
#REF! PVC Drain piping 0 0
#REF! Providing & fixing of PVC Drain piping - Rigid PVC piping complete with fittings, supports as per and duly insulated with 6 mm thick closed cell nitrile rubber insulation. 0 0
#REF! 18 25mm Dia RMT 125 Included 0.00 0 0
#REF! 18 32 mm Dia RMT 85 Included 0.00 0 0
#REF! 18 40mm Dia RMT 35 Included 0.00 0 0
#REF! Outdoor stand 0 0
#REF! 18 M. S. C chanel black enamel painted outdoor stand units. Nos. 4 Included 0.00 0 0
#REF! 18 Supply and Fixing of GI Tray (150x300 x150) along with cover, supports, C Channel etc for exposed piping on terrace. RMT 15 Included 0.00 0 0
#REF! 18 Supply and Fixing of GI Tray (50x200 x50) , supports, C Channel etc for Internal piping on Floor. RMT 20 Included 0.00 0 0
#REF! Non-VRV 0 0
#REF! 18 Installation Of Split A.c Nos. 4 Included 0.00 0 0
#REF! 18 Pair of copper pipe with Insulation RMt 25 Included 0.00 0 0
#REF! Providing & fixing of Interconnected Electrical wiring between Indoor & Outdoor 0 0
#REF! 18 Transmission wire 4c x2.5 Sq mm RMt 30 Included 0.00 0 0
#REF! Providing & fixing of PVC Drain piping - 0 0
#REF! 18 25 mm Dia Nos. 20 Included 0.00 0 0
#REF! 18 Wall Stand for outdoor Units Nos. 4 Included 0.00 0 0
#REF! 18 Providing Nitrogen & pressure test between Indoor & Outdoor refrigerant pipe - 34 &36 HP Nos. 2 Included 0.00 0 0
#REF! 18 Vacuumization and Additional Gas Topping /Filling Ckt 2 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
#REF! 18 Included 0.00 0 0
CIVIL WORKS CIVIL WORKS Revaluation of J column Tax Calculation
1 SITTING AREA , SIZE-52X22 (SOC ROOM) 0 0
2 18 Dismantelling of partition and ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
3 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
4 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
5 18 Windows closer (With Brickwork & plaster, complete) nos 4 Included 0.00 0 0
6 18 BMs room build with gypsum size 5x5 nos 1 Included 0.00 0 0
7 18 Rest room build with gypsum size 5x5 nos 1 Included 0.00 0 0
8 18 Paint & putty sq ft 925 Included 0.00 0 0
9 18 Doors fire rated nos 3 Included 0.00 0 0
10 18 work station desk (make Godrej/Pyrotech/Cosmos or equivalent) nos 21 Included 0.00 0 0
11 18 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 21 Included 0.00 0 0
12 18 Three seater sofa with table in rest room (make leatherite Godrej) set 1 Included 0.00 0 0
13 18 ceiling sq ft 1144 Included 0.00 0 0
14 18 Video wall_Panelling works (wooden paneling for 8 Nos.(4x2 Matrix) 55" LCD/LED Video Wall) Lot 1 Included 0.00 0 0
15 DC ROOM, SIZE-24X16 Z 0 0
16 18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
17 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
18 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
19 18 Windows closer (With Brickwork & plaster, complete) nos 4 Included 0.00 0 0
20 18 Paint ,putty sq ft 480 Included 0.00 0 0
21 18 Doors fire rated nos 1 Included 0.00 0 0
22 18 ceiling sq ft 384 Included 0.00 0 0
23 18 Rised floor sq ft 384 Included 0.00 0 0
24 UPS ROOM, SIZE-10X12 0 0
25 18 Puff partition and puff ceiling Lot 1 Included 0.00 0 0
26 18 Raised floor sqft 120 Included 0.00 0 0
27 18 Mat Lot 1 Included 0.00 0 0
28 FORENSIC LAB, SIZE-6X12 (Room no-308) 0 0
29 18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
30 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
31 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
32 18 Windows closer (With Brickwork & plaster, complete) nos 4 Included 0.00 0 0
33 18 Paint ,putty sq ft 220 Included 0.00 0 0
34 18 Doors fire rated nos 1 Included 0.00 0 0
35 18 ceiling sq ft 72 Included 0.00 0 0
36 18 work station desk (make Godrej/Pyrotech/Cosmos or equivalent) nos 4 Included 0.00 0 0
37 18 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 4 Included 0.00 0 0
38 GALLERY SIZE-160 X12 0 0
39 18 Dismantelling of ceiling, Doors, Windows, PVC sheet, Grills, etc. complete Lot 1 Included 0.00 0 0
40 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
41 18 Repairing work (Minor Brickwork with plaster) & RCC work for slab inplace of PVC sheet Lot 1 Included 0.00 0 0
42 18 Windows closer (With Brickwork & plaster, complete) nos 4 Included 0.00 0 0
43 18 Paint ,putty sq ft 2880 Included 0.00 0 0
44 18 Doors fire rated glass Double Leaf (Size3000X3300mm) nos 2 Included 0.00 0 0
45 18 Ceiling sq ft 72 Included 0.00 0 0
46 18 Texture painting sq ft 1440 Included 0.00 0 0
47 18 Wooden Paneling in Ceiling lot 1 Included 0.00 0 0
48 18 Network Room Renovation and dressing of Cables and Rack lot 1 Included 0.00 0 0
49 MISCELLANEOUS 0 0
50 18 2 nos of CCTV system set up Lot 1 Included 0.00 0 0
51 18 2 nos of access controll system setup Lot 1 Included 0.00 0 0
52 18 Lan port set up(approx 25 nos) Lot 1 Included 0.00 0 0
53 18 Almirah for keeping the hard disk etc (For reference- Godrej Dataline Media Safe) Qty 2 Included 0.00 0 0
54 311,318,316,315(Every room size 15x15) 0 0
55 18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
56 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
57 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
58 18 Windows closer (With Brickwork & plaster, complete) nos 4 Included 0.00 0 0
59 18 Paint ,putty sq ft 4600 Included 0.00 0 0
60 18 Doors fire rated glass nos 4 Included 0.00 0 0
61 18 Ceiling sq ft 720 Included 0.00 0 0
62 18 Wooden work on wall lot 1 Included 0.00 0 0
63 18 Wooden paneling in ceiling lot 1 Included 0.00 0 0
64 18 Carpet Tile on floor lot 1 Included 0.00 0 0
66 18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
67 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
68 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
1 18 Windows closer (With Brickwork & plaster, complete) nos 7 Included 0.00 0 0
2 18 Paint ,putty sq ft 1540 Included 0.00 0 0
3 18 Doors fire rated nos 7 Included 0.00 0 0
4 18 ceiling sq ft 504 Included 0.00 0 0
5 Room no 303&304(Conference room) 0 0
6 18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
7 18 Dismantelling of Wall Lot 1 Included 0.00 0 0
8 18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
9 18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
10 18 Windows closer (With Brickwork & plaster, complete) nos 1 Included 0.00 0 0
11 18 Paint ,putty sq ft 720 Included 0.00 0 0
1 18 Doors Steel with vision glass nos 3 Included 0.00 0 0
2 18 Ceiling sq ft 72 Included 0.00 0 0
18 Carpet Tile on floor lot 1 Included 0.00 0 0
18 conference table for20 seat (make Godrej) nos 1 Included 0.00 0 0
18 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 30 Included 0.00 0 0
18 Av solution for Conference room lot 1 Included 0.00 0 0
18 Wooden work on wall Lot 1 Included 0.00 0 0
Reception AREA 0 0
18 Dismantelling of ceiling, Doors, Windows, etc. complete Lot 1 Included 0.00 0 0
18 Dismantelling of Wall Lot 1 Included 0.00 0 0
18 Cleaning of site (All Debris, complete) Lot 1 Included 0.00 0 0
18 Repairing work (Minor Brickwork with plaster) Lot 1 Included 0.00 0 0
18 12 mm toughned glass(3000x32000)with theame nos 1 Included 0.00 0 0
18 Paint ,putty theame based sq ft 720 Included 0.00 0 0
18 Ceiling sq ft 72 Included 0.00 0 0
18 Carpet Tile on floor lot 1 Included 0.00 0 0
18 Reception table for2 seat (make Godrej) nos 1 Included 0.00 0 0
18 chair (make Godrej/Pyrotech/Cosmos or equivalent) nos 2 Included 0.00 0 0
18 wooden panelling for beam nos 12 Included 0.00 0 0
18 Wooden work on ceiling Lot 1 Included 0.00 0 0
18 One stand fan (make crompton, havels or equivalent) Lot 1 Included 0.00 0 0
18 Exausht grill Lot 1 Included 0.00 0 0
18 Dismantelling of ceiling Lot 1 Included 0.00 0 0
18 Cleaning of site Lot 1 Included 0.00 0 0
18 Repairing work Lot 1 Included 0.00 0 0
18 Windows closer nos 7 Included 0.00 0 0
18 Paint ,putty sq ft 1540 Included 0.00 0 0
18 Doors fire rated nos 7 Included 0.00 0 0
18 ceiling sq ft 504 Included 0.00 0 0
Washroom Renovation-3nos 0 0
18 Washroom Renovation Lot Lot 3 Included 0.00 0 0
18 Emergengy exit stair door Lot 1 Included 0.00 0 0
18 Fire rated door for Roof area nos 1 Included 0.00 0 0
VIDEO WALL (Matrix-4x2) 0 0
18 55" Full HD LCD/LED Video Wall No. 8 Included 0.00 0 0
18 Automatice Data Processing Machine with Controller as per speciifcation No. 1 Included 0.00 0 0
18 Wall Mount accessories Lot 8 Included 0.00 0 0
18 10 M DVI Cable to Connect LVS to Controller No. 12 Included 0.00 0 0
18 Installation & Commissioning Lot 1 Included 0.00 0 0
18 Warranty 3 Year Lot 1 Included 0.00 0 0
SOC Room Interior Work (Details are attached in Annexure-I)* 0 0
18 Supply of Modular rigid PVC metal Panelling Sq Ft 496 Included 0.00 0 0
18 Supply of Modular rigid PVC metal partition Sq Ft 177 Included 0.00 0 0
18 Supply of Printed metal panelling Sq Ft 47 Included 0.00 0 0
18 Supply of Curve/bend Modular rigid PVC metal Panelling Sq Ft 170 Included 0.00 0 0
18 Supply of 12mm Thick Frameless Tempered Clear Glass Door Size (±100mm) :- 1440mm X 2100mm No's 2 Included 0.00 0 0
18 Supply of Designer Acoustic Metal False Ceiling Sq Ft 390 Included 0.00 0 0
18 Supply of Designer Calcium Silicate Ceiling Sq Ft 174 Included 0.00 0 0
18 Supply of Round LED Ceiling Light (Static) No's 30 Included 0.00 0 0
18 Supply of Cove light (Static) R. Ft 101 Included 0.00 0 0
18 Supply of Wires, Switches & Conduits for Ceiling Lights Sq Ft 537 Included 0.00 0 0
18 Supply of Designer Acoustic Flooring Sq Ft 582 Included 0.00 0 0
18 Supply of Granite Stone for Floor Highlighter/steps Sq Ft 52 Included 0.00 0 0
18 Supply of CORPORATE LOGO Nos 1 Included 0.00 0 0
18 Supply of Designer Privacy Film for Glass Partition/Glass Door Sq Ft 47 Included 0.00 0 0
18 Supply of New Modular Control Desk for provision of 05 monitors & 05 Operators made in " XLAT " system. No's 2 Included 0.00 0 0
18 Supply of New Modular Control Desk for provision of 01 monitor & 01 Operator made in " XLAT " system. No's 4 Included 0.00 0 0
18 Supply of Chair No's 14 Included 0.00 0 0
18 Scope of Design Lot 1 Included 0.00 0 0
18 Project Management/Supervision Charges for Installation & Commissioning for Control Room Interior Lot 1 Included 0.00 0 0
Total Installation Charges 0.00 0
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 3
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 4
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Training Charges for Training to be imparted
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Training Charges excluding GST Total Training Charges excluding GST Total GST as confirmed by Bidder
Revaluation of J column Tax Calculation
NOT APPLICABLE Revaluation of J column Tax Calculation
Included 0.00 0 0
Total Training Charges 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 4b
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Maintenance Charges during & after Defect Laibility Period
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Maintenance Charges excluding GST Total Maintenance Charges excluding GST Total GST as confirmed by Bidder
0 Revaluation of P column Tax Calculation
A. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
B. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
Total Maintenance Charges during and after Defect Liabilty Period 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 5
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Civil & Electrical works (Supply Installation Services) (Schedule-3) 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 5
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4a) and Maintenance Charges during and after Defect Liabilty Period (Schedule-4b)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 6
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule - 6 After Discount
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
(GRAND SUMMARY)
Bidder’s Name and Address (Sole Bidder) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Civil & Electrical works (Supply cum Installation Charges)
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Schedule 7
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
SL. NO. PR No Line Item No Code HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total GST as confirmed by Bidder Revaluation of M column Tax Calculation Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
1 Included 0.00 0 0.00
2 Included 0.00 0 0.00
TOTAL TYPE TEST CHARGES 0.00
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
Bidder’s Name and Address (Sole Bidder) :
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Sole Bidder) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Sole Bidder) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-3 In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Civil & Electrical works ( S&I Charges) In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4a : Training Charges In Rs. 0.00 0.0000000000% Schedule-4a : Training Charges 0.0000000000%
Schedule-4b : Maintenance Charges during and after DLP In Rs. 0.00 0.0000000000% Schedule-4b : Maintenance Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. 0.00 0.0000000000% Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Civil & Electrical works (S&I Charges) In Percent (%) 0.00 0.00%
Schedule-4a : Training Charges In Percent (%) 0.00 0.00%
Schedule-4b : Maintenance Charges during and after DLP In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440) Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Civil & Electrical works (S&I Charges). 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 4b Maintenance Charges during & after Defect Laibility Period.
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 1
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP Statement of Quoted / Corrected Prices Page
Spec. No. Specification No.: NR1/NT/S-MISC/DOM/I00/24/05127 (Rfx-5002003440)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
Renovation works of 3rd floor of NRPC Building, 18-A, Qutab Institutional Area, Shaheed Jeet Singh Marg, Katwaria Sarai, New Delhi for establishment of CSIRT-Power under MOP Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01-Section - I IFB SSTE Vol-I Civil.docx
docx • 0.05 MB
02 Section-II ITB SSTE Civil (Feb-19).pdf
pdf • 0.67 MB
03 Section - III_BDS Civil.docx
docx • 0.08 MB
04-Annexure-A (BDS)-QR.doc
doc • 0.05 MB
05-Annexure-B(BDS).docx
docx • 0.02 MB
06-Annexure-C(BDS).docx
docx • 0.03 MB
07-Section-IV GCC-Civil Works.pdf
pdf • 0.67 MB
08 Section - V SCC Civil Vol-I.docx
docx • 0.07 MB
09_Appendix-I to SCC.pdf
pdf • 0.35 MB
10_Appendix-II to SCC.pdf
pdf • 0.82 MB
11 Section-VI Forms and procedures.docx
docx • 0.12 MB
BILL OF QUANTITY (BOQ).xlsx
xlsx • 0.06 MB
Gen Specification_PART_A.pdf
pdf • 0.07 MB
Gen Specification_PART_B.pdf
pdf • 0.18 MB
LAYOUT DRAWING.pdf
pdf • 0.27 MB
SFQP.pdf
pdf • 2.22 MB
Tech Spec _Power cable.pdf
pdf • 0.26 MB
Tech Spec_II_SOC ROOM.pdf
pdf • 0.29 MB
Tech Spec_I_SOC Room.pdf
pdf • 0.59 MB
Tech Spec_LT Switchgear.pdf
pdf • 0.47 MB
Tech Spec_Video Wall.pdf
pdf • 0.21 MB
DRAWING_FENCING.pdf
pdf • 0.00 MB
DRAWING_OPEN YARD.pdf
pdf • 0.00 MB
Technical Specifications.pdf
pdf • 0.00 MB
01 First Envelope Bid Forms.xls
xls • 1.54 MB
02 Legends for Units.pdf
pdf • 0.03 MB
03-Attachment-3-Bidder Eligibility.doc
doc • 0.04 MB
04 Attachment-18_SAFETY PACT.pdf
pdf • 0.36 MB
05-Attachment 14 INTEGRITY PACT.pdf
pdf • 0.20 MB
06 Attachment-20 KMP Declaration Format.doc
doc • 0.06 MB
07 Attachment 21-Affidavit for correctness of information.docx
docx • 0.02 MB
08 Attachemnt-22_Declaration regarding events encountered.docx
docx • 0.03 MB
09 Attachment 23- Certification by the Bidder as per DoE order in line with ITB 2-1.docx
docx • 0.02 MB
10 Attachment-24_Affidavit for self-certification regarding Minimum Local Content.DOCX
docx • 0.02 MB
11_Attachment-25-Compliance to the process related to the e-RA.docx
docx • 0.02 MB
12_Checklist.xlsx
xlsx • 0.01 MB
Price_Schedule.xlsx
xlsx • 1.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .