Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹15.9 L+₹1.2 L (7.85%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR/MAINTENANCE WATER SUPPLY INFRASTRUCTURE AND ALLIED WORK AF STATION UNDER GE BORJHAR
2020_MES_405785_1
8201/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹40,000
Yes
30 Jan 2021
22 Dec 2020
16 Jan 2021
22 Dec 2020
14 Jan 2021
2 Jan 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth and getting out in loose/soft soil for removing/laying of pipe line, complete, all as specified and directed.
Returning, filling in including spreading, leveling and well ramming in layers not exceeding 25 cm in soft/loose soil, complete, all as specified and directed.
Removing excavated soil/materials, not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point, complete, all as specified and directed.
Taking up unserviceable GI water main (including all fittings) complete all as directed and specified for the following bore of pipes:-
(a) 20 mm bore
(b) 25 mm bore
Supply & Laying Galvanized iron tubing, medium grade with all fittings and laid in trenches complete all as specified and directed for the following sizes:-
(a) 20 mm bore
(b) 25 mm bore
Taking out sluice valves refacing, regrinding and refixing of size 80 mm dia
Taking out sluice valves refacing, regrinding and refixing of size 100 mm dia
Taking out sluice valves refacing, regrinding and refixing of size 150 mm dia
Taking out reflux(NRV) valves refacing, regrinding and refixing of size 100 mm dia
M & L 100 mm (4") dia. Valve, reflux (NRV) confirming to IS 5312 with by-pass arrangement complete all as specified and directed.
Dismantling and taking out unserviceable Cast iron fittings up to 150 mm bore pipe including burning out lead joint, complete, all as directed.
M&L for Cast iron fittings for spigot and socketed pipes such as bends, tail piece, tee,collars, etc up to 150 mm bore medium duty and fixed in position complete all as directed.
Burning out lead joints in position including removing of old lead from the work site leeping aside for ruse or remove to store all as directed for following CI pipes :-
(a) 80 mm dia bore
(b) 100 mm bore pipe
(c) 150 mm bore pipe
Run lead joints except lead and pipe for pie and pipe spun yarn complete all as specified and directed for the following sizes :-
(a) 80 mm dia bore
(b) 100 mm bore pipe
(c) 150 mm bore pipe
M&L for Run lead joint complete with all jointing materials for the following sizes:-
(a) 80 mm bore
(b) 100 mm bore
(c) 150 mm bore
Dismantling and taking out unserviceable stop valves of following size:-
(a) 50 mm dia bore
(b) 40 mm dia bore
(c) 25 mm dia bore
(d) 20 mm dia bore
(e) 63 mm dia bore
Taking up U/S GI water main (including all fittings) complete all as directed and specified for the following bore of pipes:-
(a ) 40 mm bore
(b) 50 mm dia bore
(c) 80 mm bore
(d) 100 mm bore
M & L for 3-layer PP-R Polypropylene random (co polymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches of size 20 mm dia
All as per item no 18.00 here in before but of size 25 mm dia
All as per item no 18.00 here in before but of size 40 mm dia
All as per item no 18.00 here in before but of size 50 mm dia
All as per item no 18.00 here in before but of size 63 mm dia
All as per item no 18.00 here in before but of size 90 mm dia
All as per item no 18.00 here in before but of size 110 mm dia
M & L for Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc of size 16 to 40 mm bore dia complete all as specified and directed.
All as per item no 25.00 herein above but of size 50 to 75 mm bore dia
Supply and fixing 3 mm thick MS sheet cover plate with locking arrangementsin existing valve pit and removing of old / rusted MS cover all as directed.
S&F PPR Gate valve of size 20 mm bore, complete, all as directed.
S&F PPR Gate valve of size 25 mm bore, complete, all as directed.
S&F PPR Gate valve of size 40 mm bore, complete, all as directed.
S&F PPR Gate valve of size 63 mm bore, complete, all as directed.
Supply and fix, as in repair, stop valve, cast copper alloy, screwed down high pressure, with crutch or butterfly handles for 25 mm bore pipe or for unions all as specified and directed.
Supply and fix, as in repair, stop valve, cast copper alloy, screwed down high pressure, with crutch or butterfly handles for 20 mm bore pipe or for unions all as specified and directed.
S&F replacement to unserviceable FRP Dozing tank in lieu of provided with new FRP Dozing tank, capacity 100 Ltrs, provn for mounting of motor on lid/wall level gauge complete all as specified and as directed. Make :- Aquafit (Varima) /Vikram /RMCO/ Declibac
S & F Replacement of chlorine dosing pump motor suitable for ALT GP Gralular chemical complete all water and electric connection all as directed.
Dismantling Altoc dosing motor, 0.5 HP and taking out complete burnt winding from the slots, cleaning the slots and Re-winding electric motor with PVC insulated super enamel copper wire of suitable gauge and size and quantity ancluding applying insulating varnish, drying and two coat synthetic enamel paint (1st quality) etc including replacement of unserviceable spares like bearing etc and testing insulating strength complete all as specified and as directed by Engineer –in- charge. Note :- Contractor will be responsible for free of cost repairing if burnt under 6 (Six) month warrenty period.
S&F replacement to unserviceable 3/8 inches white suction/discharge stainless steel tubing in lieu of provided with new 3/8 inches white suction/discharge stainless steel tubing suitable for Altoc dozing pump complete all as specified and as directed. Make :- Declibac Cat No.MALT002 or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F replacement to unserviceable weightened suction line strainer 3/8 inches in lieu of provided with new weightened suction line strainer 3/8 inches suitable for Altoc dozing pump complete all as specified and as directed. Make :- Declibac Cat No.ST138 or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F replacement to unserviceable pump tube in lieu of provided with new pump tube suitable for Altoc dozing pump complete all as specified and as directed.Make :- Declibac Cat No.MCCP207-B or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F replacement to unserviceable injection check valve 3/8 inches in lieu of provided with new injection check valve 3/8 inches suitable for Altoc dozing pump complete all as specified and as directed.Make :- Declibac Cat No.MCINJ38 or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F replacement to unserviceable Roller assembly pack of 4 in lieu of provided with new Roller assembly pack of 4 complete all as specified and as directed.Make :- Declibac Cat No.MC3ASYD or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F for replacement to unserviceable connecting nut 3/8 inches in lieu of provided with new connecting nut 3/8 inches complete all as specified and as directed.Make :- Declibac Cat No.MANUT00 or Equivalent of Aquafit (Varima) /Vikram /RMCO
S&F replacement to unserviceable Agitator motor in lieu of provided with new Agitator motor 230 volts, single phase, 50 Hz, 120 watts capacity, 0.4Amps, 920RPM complete all as specified and as directed.Make :- Declibac Cat No.042009A or Equivalent of Aquafit (Varima) /Vikram /RMCO
M & L for detecting carefully the fault location of GI/PPR pipe leakage taking out the/remove the faulty portion of pipe from undergound all length respectively inc connecting/testing on completion all as directed by EIC. (i) Excavation & earth work shall be deem to be included in the unit rate of this item of work.(ii) Lead joint shall be measured and paid seperatly under respective item of this schedule (iii) Actual detected fault shall be paid under this item. Dummy located trail shall not measured & paid under this item
Dismantling to geyser of capacity 25 ltr of any make, taking out inner tank, descaling the inner surface by scrapping carrying out soldering/brazinggas welding to prevent the leakage, filling of glass wool & assembling the same after repair including replacement of required number of stainless steel screws, nuts & bolts for fixing of siphon assembly etc complete all as specified and directed by Engineer-in-charge. Note - Glass wool shall be measured & paid as Supply separately under concerned item.
S & F for replaced to unserviceable Stainless steel inner tank of 25 ltr capacity geysers of existing make & model including testing after assembled & fixed at site complete all as specified and as directed by Enginer-in-charge.
S & F strainless steel Gyser connection pipe of length 45 to 65 cm complete all as directed
S & F Gyser heating element of rating 1500 watt complete all as directed
S & F Thermostate rod suitable fo 25 ltrs Gyser
S & F 15 Amps Plug top 240 volts 50 hz complete all as directed
S & F 15 Amps Socket out let Three Pin with PVC board fixed on the wall including taking down old unsv socket comple all as directed
M&L for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with sub class 'B' bricks in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping MS frame with 40 x 40 x 6 mm angle iron 3 mm thick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
All as per item No 52 here-in-before but valve pit of size 60 x 60 x 60 cm.
Material and labour for providing Plain Cement Concrete (1:3:6) type C2 using 40mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
M/S Trio Engineers And Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .