Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | ₹1.2 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.2 Cr+₹4.4 L (3.74%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹1.2 Cr+₹4.4 L (3.74%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹1.4 Cr+₹25.2 L (21.6%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | ₹1.4 Cr+₹25.2 L (21.6%) | L3 | Rejected-Finance Other than lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not recommended as the firm is having residual work in hand more than 05 times the tendering limit of Rs. 100.00 Lakhs Note No.01 of Appx A to NIT |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L2 | anand enterprises L3 | A.B.Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for laying of UG Cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engr-in-Charge | 271 | Cum | 120 ₹32,520 Lowest | 250 ₹67,750 | 145 ₹39,295 |
| 2.00 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed by Engr-in-Charge | 240 | Cum | 40 ₹9,600 Lowest | 50 ₹12,000 | 50 ₹12,000 |
| 3.00 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point complete all as specified & directed by Engr-in-Charge. | 31 | Cum | 40 ₹1,240 Lowest | 50 ₹1,550 | 50 ₹1,550 |
| 4.00 | Material and labour for Double wall corrugated Duct pipe,Orange Colour (450 N), ISI marked (IS 16205 (Part -24) (Electrical Use) of outer dia 110 mm, inner dia 95 mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of HT cable XLPE grade 11000 volts complete all as specified and directed by Engineer-in-Charge. | 685 | RM | 140 ₹95,900 Lowest | 185 ₹1,26,725 | 185 ₹1,26,725 |
| 5.00 | M&L for boring hole under the road/pavement /hard standing with the help of trenchesless technology using ultra sound technique and necessary machine complete including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified & directed.
Note : HDPE pipe of 150 mm dia will be deemed to be included in the quoted rate.Contractor shall quote the rate including HDPE pipe 150 mm medium grade. | 18 | RM | 650 ₹11,700 Lowest | 1,500 ₹27,000 | 1,200 ₹21,600 |
| 6.00 | S&F HT 11 KV bus bar chamber ( 90cm x 45cm x 150 cm) outdoor type weather and vermin proof factory fabricated CPRI approved duly painted with two coat of enamelled paint, pedestal type made out of mild steel sheet 3.15mm thick, factory made, using angle iron 50mm x 50mm x 6mm and 500mm high from GL, front opening double shutter weather proof , rust proof, dust proof with provision of rubber gasket and locking arrangement including HT bush, Post insulator & Aluminium bus bar with color code - 03 Nos (Suitable for fixing of 120 Sqmm HT Cable),Danger Notice Board with skull sign (danger sign) & Voltage indication in front side of Panel,cable gland of suitable size for cable entry & exit and making connection with suitable size of thimbles, nuts, bolts and washers etc incl necessary earth work. for fixing of Bus bar chamber at ground completed all as specified & directed by Engr-in-Charge. | 1 | Each Job | 30,000 ₹30,000 Lowest | 35,000 ₹35,000 | 51,000 ₹51,000 |
| 7.00 | Supply and fixing cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. completed all as specified & directed by Engr-in-Charg | 18 | Each | 3,000 ₹54,000 | 3,700 ₹66,600 | 2,800 ₹50,400 Lowest |
| 8.00 | Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. completed all as specified & directed by Engr-in-Charg | 2 | Each | 6,000 ₹12,000 | 9,500 ₹19,000 | 5,600 ₹11,200 Lowest |
| 9.00 | Supply, installation, commisioning and testing of 11KV, 630A, 21KA, 3sec motor operated, compact gas insulated for outdoor application with IP-67 class of protection with SS 304 grade tank, impulse withstand voltage of 75 kV, insulation level of 28 kV (@power frequency of 1 min), control voltage 24V DC for motor operation, fully rated with earth switch, spring assisted mechanism, Arc proof type cable cover interlocked with Earth Switch, Red/Green Push button for On/Off Operation, capacitive voltage indication fixed type with aux contact, The VCB of RMU must have duty class of E2, M2 & C2 with 10000 mechanical operations(Type test report required at the time of drawing submission). Make of VCB and VI should be of same make for better optmization, suitable rating CTs and boots suitable for bottom entry front / side / rear termination of 3 core cable 120-240 Sqmm, both side extendible non- draw out type Ring Main Unit having interlocking facility & internal arc tested with 21kA for 1s in cable & tank compartment (type test reports required along with drawing) with following details.
(03 Module HT Switchgear RMU 3 way (having 02 LBS & 01 VCBs) from OEM factory only.
(a) Incoming :
(i) Incomer No.1:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer
(On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.
(ii) Incomer No.2:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer
(On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.
(b) Outgoing:
(i) Outgoing No. 1:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.
Note 1 - Foundation work as per OEM's recommendation is deemed to be included in the quoted rates for installation of RMU.
Note 2 - Units shall be SCADA compatible. Note 3 - Drawing to be submitted for approval to GE before procurement of Item. | 2 | Each | 6,15,000 ₹12,30,000 Lowest | 8,12,500 ₹16,25,000 | 6,31,000 ₹12,62,000 |
| 10.00 | Supply, installation, commisioning and testing of 11KV, 630A, 21KA, 3sec motor operated, compact gas insulated for outdoor application with IP-67 class of protection with SS 304 grade tank, impulse withstand voltage of 75 kV, insulation level of 28 kV (@power frequency of 1 min), control voltage 24V DC for motor operation, fully rated with earth switch, spring assisted mechanism, Arc proof type cable cover interlocked with Earth Switch, Red/Green Push button for On/Off Operation, capacitive voltage indication fixed type with aux contact, The VCB of RMU must have duty class of E2, M2 & C2 with 10000 mechanical operations(Type test report required at the time of drawing submission). Make of VCB and VI should be of same make for better optmization, suitable rating CTs and boots suitable for bottom entry front / side / rear termination of 3 core cable 120-240 Sqmm, both side extendible non- draw out type Ring Main Unit having interlocking facility & internal arc tested with 21kA for 1s in cable & tank compartment (type test reports required along with drawing) with following details.
(03=5 Module HT Switchgear RMU 5 way (having 02 LBS & 03 VCBs) from OEM factory only.
(a) Incoming :
(i) Incomer No.1:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer
(On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.
(ii) Incomer No.2:- 01 No., 630 Amp motorized Load break switch triple pole, single break 3 position as incomer
(On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, earth fault indicator.
(b) Outgoing:
(i) Outgoing No. 1:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.
(ii) Outgoing No. 2:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A..
(iii) Outgoing No. 3:- 01 No., 630 Amp motorized Vaccum circuit breaker triple pole, single break 3 position with duty class of E2, M2, C2 with 10000 mechanical operations as outgoing (On, Off and earth having STC capacity 21KA for 3 seconds with copper bus bar and copper earth bar as per IEC 61958-1, cable bushings, shunt trip control, busbar cover, ring core current transformer of ratio 50/1 A.
Note 1 - Foundation work as per OEM's recommendation is deemed to be included in the quoted rates for installation of RMU.
Note 2 - Units shall be SCADA compatible. Note 3 - Drawing to be submitted for approval to GE before procurement of Item. | 2 | Each | 14,85,000 ₹29,70,000 | 14,65,000 ₹29,30,000 | 13,84,000 ₹27,68,000 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
18 Apr 2026, 6:00 pmClosed
Col Manav Pant, CWE
HQ CWE (AF) Chakeri, Kanpur
PROVISION OF TROLLEY MOUNTED DISTRIBUTION TRANSFORMER WITH LT PANEL AND PROVISION OF DEFICIENT DISTRIBUTION TRANSFORMERS AGAINST BER AT AFS KANPUR AND PROVISION OF HT AND LT RING MAINT UNIT RMU AT 7 AFH
2026_MES_757143_1
CWE(AF)/CHK/EM/T-45 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M Chakeri
Please refer tender documents
7 documents required · 7 mandatory
₹1,000
GE (AF) E/M Chakeri
₹1.8 L
17 Jul 2026
20 Mar 2026
27 Apr 2026
20 Mar 2026
18 Apr 2026
11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, for laying of UG Cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified & directed by Engr-in-Charge | - | Cum | - | - |
| - | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified & directed by Engr-in-Charge | - | Cum | - | - |
| - | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc 1.5 m above starting point complete all as specified & directed by Engr-in-Charge. | - | Cum | - | - |
| - | Material and labour for Double wall corrugated Duct pipe,Orange Colour (450 N), ISI marked (IS 16205 (Part -24) (Electrical Use) of outer dia 110 mm, inner dia 95 mm with smooth internal and profiled external surface, non-pressure laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of HT cable XLPE grade 11000 volts complete all as specified and directed by Engineer-in-Charge. | - | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.95 MB
BOQ_848098.xls
BOQ • 1.24 MB
tender82471.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .