Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.4 CrAccepted-AOC RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | ₹1.4 Cr | 1 | Accepted-AOC BEING LOWEST |
| 2 | 2₹1.5 Cr+₹7.2 L (5.13%)Rejected-Finance | ₹1.5 Cr+₹7.2 L (5.13%) | 2 | Rejected-Finance Not being lowest |
| 3 | 3₹1.5 Cr+₹9.1 L (6.48%)Rejected-Finance | ₹1.5 Cr+₹9.1 L (6.48%) | 3 | Rejected-Finance Not being lowest |
| 4 | 4₹1.6 Cr+₹15.1 L (10.7%)Rejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹1.6 Cr+₹15.1 L (10.7%) | 4 | Rejected-Finance Not being lowest |
| 5 | 5₹1.6 Cr+₹20.2 L (14.4%)Rejected-Finance | ₹1.6 Cr+₹20.2 L (14.4%) | 5 | Rejected-Finance Not being lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
6 Aug 2022, 6:00 pmClosed
CWE AF GWALIOR
CWE AF GWALIOR
CONSTRUCTION OF GSE SHEDS EW ROOM FOR ACCOMMODATING AND REPAIR OF EQUIPMENTPROVISION OF WORK SERVICES AT ANNEXES PROVISION OF REMOTE OPERATED TRAFFIC BARRIER AND WIDENING OF EXISTING ROLLER GATE OF METRO DISPERSAL AND PROVISION OF WORK SERVICE
2022_MES_525286_1
85026/e8
Open Tender
Civil Works
Item Rate
270 days
GWALIOR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Garrison Engineer (AF) Tech Area Gwalior
₹2.1 L
Yes
27 Sept 2022
20 May 2022
8 Aug 2022
20 May 2022
6 Aug 2022
16 Jul 2022
Amount
Demollition of unreinforced cement concrete/bituminious surface including cutting edges for coloumn footings, ground floors and pavings below or above G.L complete and removal of demolished material out of MoD land complete all as specified and directed .
Demollition of reinfoced cement concrete of any description and in any position not otherwise specifically provided for below or above G.L complete and removal of demolished material out of MoD land complete all as specified and directed .
M&L for demolition of concrete in ground floor of any thickness by mechanical tools including cutting existing panels and removing excavated material exceeding 1.50 km and not exceeding 5.0 km complete all as specified and directed
Demolition of brick work or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc including disposal of rubbish complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
Excavation in trenches in Hard & dense soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed.
All as per item No. 6.0 above but exceeding 1.5m and not exceeding 3.00m in depth complete all as specified and directed..
M&L for plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings,plinth beams, and mass concrete etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use & waste of form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, and plinth beam and similar work for rough finished flat surfaces of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in columns,pillars,piers,popst and struts etc.complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to sides of columns,pillars,piers,popst and struts for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in lintels beam, floor/roof Beams, cantilevers, bressummers, , chajja etc complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to sides of soffit of lintel Beam,floor/roof Beams, chajja etc for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to soffit of slab etc.for rough finished surface of concrete complete all as specified and directed.
M&L reinforced cement concrete M-25 (design mix) (using 20 mm graded crushed stone aggregate) as in stair case, including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, excluding landings complete all as specified and directed. Note : Reinforcement & form work will be measured & paid seperately under respective item of BOQ.
Use and waste of form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter etc for rough finished surface of concrete complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over grade Fe-500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 8 mm dia grade Fe -500, as in reinforcement ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for mild steel TMT bars 08 mm dia and over grade Fe -500 , as in stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed.
M&L for Brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed.
M&L for half brick thick Brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed.
M&L for rendering 15 mm thick on brick masonry/concrete surface etc in CM (1:4) surface finished even & smooth using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair face brick masonry/concrete surface etc in CM (1:6) surface finished even & smooth using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:4 on concrete surfaces as in ceiling finished even and fair complete all as specified and directed.
M&L for preparation of newly plastered surface and applying two coats of oil emulsion distemper with roller over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specified and directed.
M&L for preparation of newly plastered surface and applying two coat acrylic exterior emulsion paint of required shade with roller over and including priming coat of exterior primer and a layer of putty (not less than 1.5 mm thick ) complete all as specified and directed.
S&F Powder coated aluminium work for doors, windows, ventilators and partitions frames with extruded built up standard tubular sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with EPDM sealent with wall, i.e. at top, bottom and sides including cleat angle, C.P. brass/ stainless steel screws, all complete all as specified and directed.
S&F powder coated aluminium work for doors, windows shutters with extruded built up standard tubular sections of approved make including cleat angle, C.P. brass/ stainless steel screws, sliding wheels, groves with brush and suitable locking arrangements complete all as specified and directed.
S & F 4 mm thick tinted glass fixed to aluminium window with aluminium snap beading and glazing EPDM rubber/ neoprene gasket etc complete all as specified and directed.
S&F 5 mm thick tinted glass fixed to aluminium doors including aluminium snap beading and glazing EPDM rubber/ neoprene gasket etc complete all as specified and directed.
S&F 4 mm thick aluminium composite pannel (ACP) fixed with aluminium snap beading and EPDM rubber/ neoprene gasket etc complete all as specified and directed.
S&F for powder coated aluminium deco grills size 4mmx4mm, 8mm thick and aperture not exeeding 80 mm X 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete all as specified and as directed.
S&F 150mm size of powder coated extruded aluminium alloy handles, fabricated type, anodised complete all as specified & directed.
S&F 150 mm size of powder coated aluminium barrel tower bolts of extruded section and fixed all as specified and directed.
S&F of brass mortice lock, with handle vertical type, size 100 mm four levers (ISI marked) for aluminium doors complete all as specified and directed.
M&L double action floor spring hydaulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of aluminium, other parts made of mild steel heavy duty and fixed in floor including cutting of floor for fixing of machine and make good in affected area complete all specified and directed.
M&L for Vetrified coloured ceramic tiles, double charged 8 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 20 mm thick screed bed in cement mortar (1:4) etc complete all as specified & directed.
M&L for Vetrified coloured ceramic tiles, double charged 8 mm thick (Square/rectangular) area of each tile not exceeding 0.36 Sqm on vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed.
S&F false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mm x 32mm and cross Tee of size 24 mm x 27 mm and wall angle of size 22.2 mm x 22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners from roofs slab with butterfly clips etc including 12mm thick calcium silicate boards (SCALA RH-70 Armstrong) in ceiling fixed to GI snap grid frame work, including making provision for housing light fitting, AC grills etc complete including fixing, wastage T&P as per manufacturer's instructions and complete all as specified and directed .
M & L for providing and fixing stainless steel (ISI marked Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of wall, floor or the side of waist slab with suitable arrangement.
S & F framed work as in doors or gates of angle or other tubular hollow sections with necessary running welding with gusset plates, guide rails, braces, drilled etc., to be prepared for hanging or sliding gates and including hooks and hinges etc complete all as specified and directed.
M&L for prepartion of new or previously untreated steel surface of any description , not otherwise described over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
M&L for 16 to 18 mm thick granite slab (or any type) table rubbed and pre mirror polished for wall lining (veneering to wall) set & jointed in neat cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,over & including 15 mm thick rendering in cement mortar(1:4) etc complete all as specifed and as directed.
M&L for 15mm thick designer tiles as in steps trades and riser( tiles of size not exceeding 0.36 Sqm )any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry as in staircase including 15 mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
Excavation in post holes (or similar holes) not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm thick as in soft / loose soil including watering & removing surplus soil material to a distance not exceeding 50 mtr & making good surface complete all as specified & directed.
M&L for plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in foundations for tubular post ,filling & mass concrete etc complete all as specified and directed.
S&F steel work in tubular trusses /tubular post (square/ rectangular /circular) steel tubular sections including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 Grade St-240 complete all as specified and directed. Make: ISI Marked as approved by GE Note: Drawing & design shall be approved by GE.
S & F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, welded/bolted to steel frame/truss without any attachment complete all as specified and directed.
Cutting holes in bricks wall built in cement mortar inserting tubular pipe /angle section not exceeding half Brick thick wall and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 ,Type B-1 as required complete all as specified and directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep for inserting Galvalume sheet and making good to shaping horizontal face of groove with cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) finished even & smooth complete all as specified and directed.
S & F for mild steel screw bolt (machine made) of 11 mm to 15 mm dia of neck with hexagonal or square head one end and screwed the other or screwed both ends, each screw end to be fitted with washer and one hexagonal or square nut, length of bolt not exceeding 5 cm etc complete all as specified & directed.
M&L for hard core of broken stone or boulder gauge not exceeding 63mm deposited, spread & leveled in layers not exceeding 15cm thick, watered and rammed to a true surface etc complete all as specified& directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) as in sub base to flooring/hard standing /ramp etc ,complete all as specified and directed.
M & L for 10 mm thick screed bed in cement mortar 1:4 mixed with using liquid water proofing compound as per manufacturers instructions over roof top surface finished even and smooth using extra cement and application of water proofing treatment using APP modified roof membrane over existing inaccessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre / Sqm manufactured by the same agency as that of APP membrane with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface & hot blown grade bituminen 85/25 @ 1.2 Kg/Sqm over primer . (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.00 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650 Kg / Sqcm and transverse not less than 450 Kg /Sq.cm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Applying a coat of bituminious Aluminium Paint over APP Membrane. (Note:Water proofing compound shall be measured and paid seprerately under respective item of "BoQ")
Supply only liquid water proofing compound complete all as specified and directed.
Dismantling mild steel work (tee, angle, channel or flat sections) of any description not otherwise provided for as in post, rafter, purlins etc rails and refixing the same by welding, drilling holes nut bolts etc as per site requirement complete all as specified & directed.
S&F roof trusses (framed), trussed, purlins, rafter,framing (beam, tee, angle, channel or flat sections) distance pieces, cleats including fabrication and fixing conforming to Fe-410-W(Gde E-250) quality-A complete all as specified & directed.
Dismantling old plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & directed.
S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed
S&F S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in flashings like inner corners of size 40 x 40mm, outer corners of size 100x100mm and doors channels of size 30x82x30mm fixed with self tapping screws all as specified and as directed.
M & L for mild steel structure with main vertical Columns of ISMB 150mm, rafter of ISMB 150mm, Tie beam of ISMC 100mm, Purlins top/bottom MS C-Channel to fix the panels including mild steel cleats, brackets etc welded/bolted to steel frame/ truss complete all as specified and directed.
M&L for prepartion of old painted steel surface of any description , not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
S&F 10mm thick toughned glass as in partitions and similar works including cutting to shape, drilling holes and fixed to aluminium section and wood work of colour as approved by GE complete all as specified and directed.
S&F 25mm thick HDHMR (High density high moisture resistance) Board, prelaminated both sides with decorative choice lamination including cover the edges of board with matching laminates, fixed with screws & favicol where required as in cubical desk and cabinets including making holes with decorative covers for wires where ever required fixed to Aluminum partition complete all as specified and directed.
S&F 18/19mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws & favicol where required as in cubical desk and cabinets including making holes with decorative covers for wires where ever required fixed to aluminum partition complete all as specified and directed.
S&F Stainless steel handles 100mm size fancy and decorative type for cabinets shutters as per directed by Engineer-in - Charge complete all as specified and directed.
S & F auto closing hinges 35mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinets shutters complete all as specified and directed.
S&F stain less steel Sliding channels for Computer Key pad complete all as specified and directed.
S&F of brass mortice lock, with handle vertical type, size 50 mm two levers (ISI marked) for cupboard grade I complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base to flooring/hard standing etc ,complete all as specified and directed.
M&L for 60mm thick factory made machine pressed pre-cast concrete coloured interlocking paver block of approved shade laid in design & pattern as in footpath, light traffic parking etc., made by table vibratory method using PU mould of any shape and size conforming to IS-15658-2006 of M-35 grade laid over & including 50mm thick over coarse sand/ stone dust, compacting and proper embedding/ laying by vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
M & L for factory made kerb stone (size 300 mm x 300mm x 150 mm) of M-25 grade(using 20 mm graded crushed stone aggregate) , chamfered/rounded at top jointed with cement mortar 1:3, in required line, level and curvature, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), complete all asspecified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) in kerbs or mud stops, rounded or chamfered on edges water troughs ,levelling course etc over roof surface and the like including necessary form work complete all as specified and directed.
S&F of 50mm thick Sandwich panel as in wall with 0.50mm thick PPGI sheet with micro ribs both sides with FR grade PUF density 40 Kg/m3 + 10% in metalic tongue and groove joint system with cam lock for additional strength, cut to size with no loading of wastage with additional 900 bends in male & female groove to have proper sealing, Strength & air tight joints panel to panel, CFC free & Ozone friendly (pentane based) all as specified and directed
M & L for 10 mm to12mm thick designer tiles of area of each tile not exceeding 0.16 Sqm , laid on parking/footpath ,any colour and shape with grey cement and pigment set, jointed and pointed on neat cement slurry over & including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed.
S&F of 40mm thick sandwich PUF panel as in door shutter of size 1000 x 2100mm. Door outer frame shall be made out of 2.0mm thick powder coated MS frame, both faces of sandwich panels consist of 0.60mm PPGI and 39mm thick 44 Kgs PUF density, Door leaf will be provided with extra reinforcement of 2mm thick MS Plate for Hinges, AL drop, door stopper & tower bolt. Door shall be fitted with 01 Nos 300mm long aluminium alloy, anodised sliding door bolt with Hasp, staple (bolt type) with nuts & bolts, 01 Nos 200mm aluminium anodised tower bolt, 02 Nos 150mm long door D type extruded aluminium alloy handles on each side, 04 Nos 100 mm size heavy duty S/S hinges & 01 Nos door closer hydraulically regulated designation No 3 universal type of aluminium(extruded section body) complete all as specified and directed. .
S&F of 40mm thick sandwich PUF panel as in door shutter of size 3000 x 3000mm in two leafs . Door outer frame shall be made out of 2.0mm thick powder coated MS frame, both faces of sandwich panels consist of 0.60mm PPGI and 39mm thick 44 Kgs PUF density, Door leaf will be provided with extra reinforcement of 2mm thick MS Plate for Hinges, AL drop, door stopper & tower bolt. Door shall be fitted with 02 Nos 375mm long aluminium alloy, anodised sliding door bolt with Hasp, staple (bolt type) with nuts & bolts, 02 Nos 300mm aluminium anodised tower bolt, 04 Nos 150mm long door D type extruded aluminium alloy handles on each side, 10 Nos 100 mm size heavy duty S/S hinges complete all as specified and directed.
S & F mild steel galvanised powder coated suspended false ceiling system with grid of size 605 mm x 605 mm, consisting of mild steel galvanised powder coated main runner of size 24 mm x 32mm and cross Tee of size 24mm x 27 mm and wall angle of size 22.2mm x 22.2mm, suspended with 6 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc includding 12-15mm thick Mineral fibre acoustic ceiling tiles in ceiling fixed to GI snap grid frame work with hold screws, of any height upto 8.5m with adjustable cleat of J- hook including making provision for housing light fitting, AC grills etc complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge.
S&F for mild steel screw bolt (machine made) of 16mm to 20mm dia of nech with hexagonal or square head one end and screwed the other or screwed both ends, each screw end to be fitted with washer and on hexagonal or square nut, length of bolt exc 22.5cm and n exc 30cm long complete all as specified and directed by Engr-in-Charge.
M & L acoustic foam wall panelling using 50mm thick tiles of size 30cmx30cm or 60cmx60cm with NRC > or equal to 0.9 made of Acoustix polyurethene of approved colour density 40 Kg/cu'm fixed to walls using SR adhesive or spray adhesive complete all as specified and directed
M&L for 2mm thick PVC (Poly vinyl chloride) flooring, plain coloured laid in floors with adhesive (PVC flooring joints to welded with PVC welding cord of same colour) including preparation of old existing concrete floor surface by grinding of edges and filling of voids with self levelling compound or as per manufacturer's instruction to make the surface plain and smooth for laying of PVC floor complete all as specified and directed. Note : Work shall be done by authorised applicator of the manufacturer.
M&L for framed work such as grills,gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railing; framework of water tanks and similar work conforming to Fe 290- Gde E -165 complete all as specified and as directed
M&L for plain cement concrete 1:2:4 ,type B-2 (using 40mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M&L for point wiring for one light point or one fan point controlled by one way switch with using with FRLS PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with Bakelite hylem sheet 3.0 mm thick complete for mounting switches, sockets, fan regulators etc complete all as specified and directed.
M&L for point wiring for One 5/6 Amp switch socket combination independent board with using with FRLS PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with Bakelite hylem sheet 3.0 mm thick complete for mounting switches, sockets, fan regulators etc complete all as specified and directed.
M&L for point wiring for One 5/6 Amp socket on same board with using with FRLS PVC insulated PVC unsheathed electric cable conforming to IS:694, 1100V grade AC, single core having multi stranded copper conductor of size 1.5 Sq.mm nominal cross sectional area for phase & neutral and including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type pressed steel terminal box 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/junction boxes with Bakelite hylem sheet 3.0 mm thick complete for mounting switches, sockets, fan regulators etc complete all as specified and directed.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for One 6 Amps socket on same board with other switches
S & F switch piano , flush type of any description , single pole , one way 5 Amps ,230 volts AC circuit complete all as specified and directed.
S & F Switch socket combination 5 in 1 flush type 5A/16A independent complete all as specified and directed .
S & F Switch socket combination 2 in 1 flush type 5A independent complete all as specified and directed .
S&F modular switch socket 6 Amps -2/3 pin combined two module, complete all as specified and directed.
S&F modular switch socket 6/16 Amps,2/3 pin combined two module, complete all as specified and directed.
S&F modular switch piano flush type single pole one way 6 Amps, one module complete all as specified and directed.
S & F ceiling rose , surface backelite 65mm x 50mm size with three terminals all as specified and as directed.
S & F stepped type electronic fan regulator flush type all as specified and directed .
S & F ceiling fans, complete with three blade, down rod, accessories 230V, 1200 mm sweep, with Squirrel cage induction motor complete all as specified and directed.
S & F Flextron LED batten fitting 20 watt and including all accessories prewired and connecting the same two ceiling rose to three core PVC insulated and sheathed copper conductor 1.5 sqmm cable including all accessories and fixing arrangemant for fixing the light to wall / roof surface complete all as specified and directed .
S & F LED lights fitting 1x 22 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core including connecting up with three core flexible copper conductor cable of suitable size and connecting the same to ceiling rose and fixing arrangement for fixing the light fitting to walls /roof surface complete all as specified and directed
Supply & fixing sheet metal enclosure for double door MCB DBs phosphatised powder coated , single pole & neutral (SPN) suitable for 8 Way , 240 volts IP 43 & IK 09 fixed on wall with din rail , neutral and earth bar , in proper position complete all as directed by the Engineer -in - Charge.
S & F Stout plus LED is a complete range of industrial LED batten to replace traditional T8 batten.The range is perfact for lighting large areas such as corridor ,warehouses & genral purpose spaces 40 watt including all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 1.5 sqmm cable with all accessories and fixing arrangement for fixing the light fitting to walls / roof surface complete all as specified and directed.
S&F lamp holder insulated body with back plate for battern fittings complete all as specified and directed.
Supply and fixing MCB single pole and neutral (SPN) of capacity 63 Amps ,240 volts ,breaking capacity 10KA 'C' series fixed in proper posotion complete all as specified & directed.
Supply and fixing MCB single pole and neutral (SPN) of capacity 6 to 32 Amps ,240 volts ,breaking capacity 10 KA 'C' series fixed in proper posotion complete all as specified & directed.
M&L for sub main wiring with two runs of 6.00 Sqmm single core FRLS PVC unsheathed and insulated 1100 Volt grade/multi stranded copper conductor drawn through existing PVC conduit/casing caping alongwith accessories fixed an surface/concealed in walls, ceiling, floors etc including one run of PVC insulated and unsheathed cable of copper conductor of 6.00 Sqmm single core as earth continuity wire all as specified and directed. Note :- Two runs of single core PVC insulated unshethed cables and one run of earth continuity conductor will be messured and paid as one unit length only. Make:Havells/Finolex/Polycab
Supplying & fixing MCB single pole, 6 to 32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.
Dismantling of LT electric cable care fully complete and fixing of pole to new location as directed by Engineer -in-charge .At a distance not exceeding 100 mtr including necessary foundation /earth work and PCC below ground level & coping up to 30 cm above ground level as including refixing of light fitting complete all as directed by Engineer-in Charge.
Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area 25 Sq.mm, 3.5 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc complete all as specified and directed.
Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area 50 Sq.mm, 3.5 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc complete all as specified and directed.
Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area 35 Sq.mm, 3.5 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc complete all as specified and directed.
Supplying, laying, jointing and testing LT 1100 volt grade XLPE insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cables (heavy duty) with stranded aluminium conductor, cross sectional area 16 Sq.mm, 2.0 Core including fixing acessories for laying on wall/ roof/mild steel sturcture ,laid in trenches/ducts, floors etc complete all as specified and directed.
Supply, fixing connecting & testing VTPN DB 12 way IP -43 suitable for upto 225 Amps MCCB as incommer and SP /TP as out going complete all as specified & directed by Engineer -in -Charge . Note:-Fittings like MCB's /Isolators etc. shall be measured and paid for separately under approprite item of BOQ.
Sypply ,fixing ,connecting & testing sheet metal enclosures double door TPN MCB DB 4 Way ,complete all as specified & directed by Engineer -in-Charge .
S & F MCCB, 3 pole 125 Amps current rating and ultimate breaking capacity lcu= 25 KA with adjustable overload setting and having thermal magnetic release and to be fixed in ditribution board complete all as specified and directed.
Supply and fixing MCB TPN of capacity 63 Amps ,240 volts ,breaking capacity 10KA 'C' series fixed in proper posotion complete all as specified & directed.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip 32 mm X 6 mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 50 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including making good disturbed surface of wall ,floors etc.complete all as directed. Notes: (i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc. (iv) Irrespective of what is shown on plate No 3 of SSR Part-I /2009, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B-1(using 20 mm graded crushed stone aggregate) with suitable handle all as specified. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) (using 20mm graded crushed stone aggregate) of size 200mmX200mmX250mm including necessary earth work.
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including making good disturbed surface of wall ,floors etc.complete all as directed. Notes: (i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc. (iv) Irrespective of what is shown on plate No 3 of SSR Part-I /1991, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B-1(using 20 mm graded crushed stone aggregate) with suitable handle all as specified. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) (using 20mm graded crushed stone aggregate) of size 200mmX200mmX250mm including necessary earth work.
Supply, installation ,commissioning and testing of split type wall mounted Air conditioner of capacity 1.5 TR (6000 K Cal/hr) single phase ,(Non CFC/HCHC ) suitable for 230 Volt + 10% ,50Hz AC supply complete with cordless remote control unit. minimum 3 star rating EER of 3.2 and above complete comprising of following :- (a) Indoor unit copper coil with three speed blower fan of approprite capacity including PCB,thermostatic control ,air filter and drain for condensing water . (b) Out door unit comprising .Compressor with motor ,air cooled copper condenser with fan and motor unit shall be installed out side the building /on roof . (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable . (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) Type B-1 (Using 20mm graded stone aggregate ) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as Manufacture's instruction with necessary grouding MS hold fast , bolts , washer duly painted and making good to disturbed surface suitable for installing out door of 2 TR AC complete all as specified and directed . (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate .
Supply and fixing voltage stablizer electronic type for automatic operation single phase naturally air cooled indoor type wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 1 % and of capacity 4.0 KVA upto 1.5 Ton complete all as specified and directed . Make- V Guuard /Blue Bird .
Material and Labour for sand filling with clean, dry and sieved fine natural river sand in two portion, including gently punning around cables after the cables are laid, in trenches for cable protection complete all as specified and directed. (NOTE: Only punned thickness measured).
Supplying & Laying un-reinforced pre-cast flat concrete cable protection cover of class LV, type- I, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix double wall corrugated (DWC) HDPE pipe 90mm OD for protection of LT/HT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any all as directed and specified
M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6.3 mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron strip 25 mm X 4 mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 40 mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-1 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, including making good disturbed surface of wall ,floors etc.complete all as directed. Notes: (i) Earth lead & protection pipes length upto & including 7.50 metre. (ii) Earth filling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders, aggregate, gravels etc. (iv) Irrespective of what is shown on plate No 3 of SSR Part-I /1991, the earthing pit shall be precasted PCC (1:3:6) type C1 and the cover of earthing pit shall be of precast RCC (1 :2 : 4) type B-1(using 20 mm graded crushed stone aggregate) with suitable handle all as specified. (v) The rates quoted by the contractor is deemed to be inclusive of cost of MS sheet for marking the result and its purpose of use of size 300mmX 300mmX3mm size fixed with necessary nuts and bolts on angle iron of length 60cm and size 40X40x5mm grouted in the ground with PCC (1:3:6) (using 20mm graded crushed stone aggregate) of size 200mmX200mmX250mm including necessary earth work.
Supply and fixing earth continuity conductor or main earthing lead 25 mm x 4mm, galvanisediron as earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint complete all as specified and directed.
M & L for providing test point terminal block made out of Gun metal or phosphorous bronze of size 75 mmx75 mm x25 mm drilled and screwed including 03 nos 8 mm dia 25 mm long hexagonal head screws complete all as specified and directed.
Supply, Install, Testing & commissioning Servo Voltage stabilizer for automatic operation, three phase, naturally oil cooled, outdoor type & designed for input variation between 170 V to 280 V (each phase)/300V-480V (3 phase) with output voltage stabilized at 415 with accuracy ± 1% and speed of correction 8 volts / sec, efficiency-95% for ambient working temperature 0 - 50 degree celcius max/relative humidity 90%, of capacity 75 KVA complete all as speicified and directed alongwith the following features.:- i) Regulator for sensing circuit to maintain constant output voltage even on DG (iii) Output voltage protection, Adjustable output under and over volt. (iv) Controls : Auto- Manual switch & lower/rise switch (v) Servo Motor Protection : Voltage cut-off servo motor at input and over voltage std upto 20 KVA (vi) Surge protection device 8/20 micro sec as per IEC-61000-4-4/61000-4-5 (vii) change over/stabilizer By pass switch
Supply, install, commissioning and testing of split type wall mounted Air conditioner of capacity 2.0 TR (6000 K Cal/hr) single phase, (Non CFC/HCHC) suitable for 230 Volt + 10% , 50 Hz, AC supply complete with cordless remote control unit with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 3 star rating complete comprising of following :- (a) Indoor unit with three speed blower fan of appropriate capacity including PCB, thermostatic control, air filter and drain for condensing water. (b) Out door unit comprising of one No. Compressor of 2.0 TR capacity with compressor motor, condenser fan motor of appropriate capacity 01 No. air cooled condenser of 2.0 TR capacity -01 No. shall be installed at out side the building. (c) Refrigerant copper pipe for suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit with control valves & safety accessories including control wiring for evaporator & condensing unit with suitable size of copper cable. (d) Making good the disturbed surface to match the existing surface after plugging the hole etc. (e) PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in plinth suitable for installation of outdoor unit or powder coated MS bracket fixed on wall as per Manufacture's instruction with necessary grouting MS hold fast, bolts, washers duly painted and making good to disturbed surfaces suitable for installing outdoor unit of 2.0 TR AC complete all as specified and directed. (f) Electrical cable required to connect out door unit and indoor unit to voltage stablizer inclusive in above rate. Note :- (i) Cutting of holes in walls/window of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by the contractor shall deemed to be inclusive of this aspect. (ii) All other connected civil works & other miscellaneous works required of installation of split AC & proper functioning as directed by Engr-in-Charge. (iii) Additional length of copper tubes for compressor inlet/outlet with insulating material, casing/capping shall be inclusive in unit rate.
M & L for sub main wiring, concealed, using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of 1100 Volts grade drawn in and including PVC rigid conduit medium grade of size not less than 25 mm dia with standard accessories fixed on walls / ceiling surface etc along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm as earth continuity conductor complete all as specified and directed Note:- Two runs of submain wire 4.0 Sqmm + one run earth wire 4.0 sqmm + one run PVC conduit shall be measure as one unit.
S & F Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one MCB SP 20 Amps, 230 Volts, 10 KA 'C' series complete all as specified and directed. Make : Legrand cat No.607841 or equivalent in Hager/Havells/Scheinder.
S & F voltage stablizer electronic type for automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 280 V with output voltage stablized at 200V to 245 V with accuracy of + 1% and of capacity 5.0 KVA complete all as specified and directed.
S & F PVC drain pipe of 20mm inner bore nylon braided industrial quality including fixing accessories on wall/roof etc complete all as specified and directed.
Supply,install, testing and commissioning of refrigirant type robust dehumidifier water extracting cap 130 Ltrs / day, anti corrosive body with elctronic display , water pump dispensor for air flow @ 850 cum per hour operating on single pahse suppy 230 volts, 50 HZcomplete all as specified and directed.
Supply, fixing, testing and commissioning of fire alarm control panel complying with BS EN 54 double loop panel of capacity from 99 dectors and 99 modules upto 200 detctors and modules complete all as specified and directed.
Supply,installing and testing of detectors complying with and type certified to EN-54 addressable type multi sensonsor detector with heat and smoke combination photo electric/optical with base as per IS 11360 complete all as specified and directed.
Supply ,installing, testing and commissioning of remote response indicators complete all as specifed and directed.
Supply, installing, testing and commissioning addressable manual call point resettable type complete all as specified and driected by Engr-in-Charge
Supply, install, test and commissioing addressable electronic sounder cum strobe complete all as specified and directed by Engr-in-charge
Material and labour for fire alarm point wiring with two 1.5 sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLSH cable 1100 volts grade drawn through in and including rigid stove enamelled steel conduit medium grade not less than 20mm dia with its accessories including two coats of synthetic enamel paint (of colour/shade as approved by GE) over conduit & making good the distrubed surface complete all as specified and directed. Note: (i) Two runs of 1.5 sqmm copper wire + one run of MS conduit of one metre length shall be considered as one unit (i.e. One RM) for purpose of measurement of this item. (ii) Wiring shall be provided on surface of wall / ceiling as directed by GE.
Supply, installation, testing and commissioning automatic access system including complete barrier mechanisim, channel, boom & controls including push button unit having 03 push button for operating the barriers and 02 indication lights showing open & close position of the barrrier to be provided at ATC and alternate ATC for controlling independently complete with electric hooter and warning light (RED) on each boom. The hooter and warning light shall comes in operation as barrier moves including with electric control panels/ wiring operated at 200-240 volts AC and 12-24 Volts DC electric supply booms of length 9 meter with alternate black and yellow strips and provided with a reflector "STOP" sign in the center and 4 bands of reflective tape for night warning and necessary foundation work if any, complete all as specifed and directed by Eng-in-charge. Equipments to be provided :- (a) Two barrier machines 1 & 2 (for roads upto 8-9 meter wide) complete with mechanism, channels, boom, controls etc. (b) Push button controls etc. Cabling Requirements :- (a) 230 Volt, 50 Hz AC power supply with earthings to each barrier machines suitable for 5 amps load per barrier to be provided. Power supply may be provided from the nearest available point but both barriers should be connected to same phase. (b) Minimum 9 core 2.5 Sqmm copper cable between barrier 1 & 2 barrier to be provided. (c) Minimum 9 core 2.5 Sqmm copper cable between barrier 2 and push button unit at ATC to be provided. Note : 1. The rate quoted above shall be inclusive of any civil works, PCC foundation, formwork etc. However if any excavation/earth work shall be measured and paid under respective item. 2. The contractor shall obtain / submitt foundation details/specification from OEM & got approved by GE prior to commencement of work. 3. Arrangement for mannual operation at time of power failure to be considered by the contractor while quoting the rates.
Supply, laying and testing LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10 Sqmm, 4 core complete laind in excavated trenches or on wall surface or drawn through GI pipes etc all complete all as specified and directed. Note : Necessary earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing wherever necessary shall be measured and paid seperately under relevant item of this schedule.
Supply and fix double wall corrugated (DWC) HDPE pipe 50mm OD for protection of LT UG cables for crossing roads/on wall/poles etc including coupling/ jointing fittings complete if any complete all as specified and directed.
M&L for Boring of hole under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with & including HDPE pipe of 150 mm dia sutable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge. Note : Pipes shall be laid minimum 1.00 mtr below/under existing road surfaces/taxi track / apron /floors etc)
Design, fabricate, supply, install, test and commissioning of factory made bus bar box made out of 3mm thick CRCA sheet, 3 phase, 4 wire, 415 volts AC supply, outdoor cubical type, dust and vermin proof, angle iron pedestal (Angle iron frame of size 40mmX100mmX5mm, 45 cm above the ground level & 30 cm embedded in PCC 1:2:4 size 200mmX200mmX200mm cast in site below the ground level mounting type of suitable size 400mmx400mmx300mm, using 40mmx40mmx5mm angle iron frame with shutter and locking arrangement, factory made powder coated painting, including 100 Amps copper busbar fixed on insulators with colour coding complete all as specified and directed.
Supply, install, test and commissioing LT Panel board, out door type, dust and vermin proof made out of 3.0 mm thick CRCA sheet and angle iron frame made out of 40 mm x40mm x 5 mm, 3 phase, 4 wire, 415 volts, factory made, powder coated consisting of following switch gears and controls, prewired with suitable guage copper conductor complete all as directed. (a) MCB single pole 10 Amps, 10 KA -10 Nos (b) MCB 4 pole / TPN 40 Amps, 10 KA -01 Nos (c) Bus bar 3 phase, wire, 100 Amps -01 set mounted on suitable insulaltors. (d) Power contactor 3 phase, 16 Amps -02 Nos (e) Air cooled transformer single phase 230 V/110V AC -01 Nos. (f) Silicon Rectifier 25 Amps -02 Nos. Note: 1. Panel design and control circuit shall be got approved by Eng-in -Charge prior to fabrication. 2. The panel internal circuit shall be pre wired for control of access system both from main ATC & alteranate ATC and manually indpendently.
Supply, install, test and commissioing LT Panel board, out door type, dust and vermin proof made out of 3.0 mm thick CRCA sheet and angle iron frame made out of 40 mm x40mm x 5 mm, 3 phase, 4 wire, 415 volts, factory made, powder coated consisting of following switch gears and controls, prewired with suitable guage copper conductor complete all as directed. (a) MCB single pole 10 Amps, 10 KA -06 Nos (b) MCB 4 pole / TPN 40 Amps, 10 KA -01 Nos (c) Push button (RED & Green) with One NO & One NC- 02 Nos. Note: 1. Panel design and control circuit shall be got approved by Eng-in-Charge prior to fabrication.
Supply, installation, commissioning and testing 60 KVA true online wave UPS with 30 minutes battery back up 300 V to 460 V A/C 50 cycle & 415 AC, Hz, three phase/4 wire for input voltage with programmable controller for output voltage with password protection & three phase phase programmable overload setting facility, enclosure protection IP-55 with complete specification given as follows :- (a) Rating :- 60 KVA:INPUT (i) Voltage - Nominal 415V, Range - 300-460V AC (ii) Frequency - Nominal -50 Hz, Range - 47-53Hz, Phase- Three. (iii) AC to AC efficiency - 92% Rectifier:- (i) Technology - 12 pulse rectifier SCR based fully controlled. (ii) THDI (Input current Harmonic distortion) - < 10% at rated load (iii) Input power factor > 0.92 lag (iv) Galvonic Isolation- inbuilt Galvanic Isolation OUTPUT Voltage - Nominal- 415V(P-P), 230V (P-N) Programmable. Regulation - (+/-) 0.5%. Frequency :- Nominal-50 Hz, Stability- (+/-) 0.05% Total Harmonic Distoration :- < 2% on linear load, Overload protection :- 120% for 30 min, 150% for 1 min, 200% for 10 cycles (Three point programmable overload setting facility)
Item 153 cont.... Protection :- Input/output voltage, input phase fail, overload over/under voltage, snubber circuit for power devices, over temperature, fuse for semi conductor devices Indication :- Mains ON. DC ON, Mains over/Under volatge, DC over/under voltage, Phase fail, output over/under volatge, overload, overheat. Remote Alarm :- Potential free contacts for input fault & output trip. Metering :- 16 X 2 LCD for I/P & O/P volts & output current. General :-Operation temperature:- 0 to 45 degree centrigrade (50 Degree centrigade peak) storage temperature :- 20 to 45 degree centrigade. Relative dumidity :- 95% non condensing. Cooling :- forced Air using localozed cooling technique with multiple fractional HP fans. Panel :- Welded structure MS cover 2mm and frame 3mm thick. Enclosure protection :- IP-55 Battries ;- Sealed mainenace free Data logging via USB interface. Cable entry :- front bottom
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes as indicated including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, trminal boxes closed recossed type. PVC Plastic board all as required as specified and directed for the following :-
(a) One light/ Fan point controlled by one way switch.
(b ) One 6 Amps switch socket combination on independent board.
All as per item no 155 here in above but 2.5 Sqmm stranded copper conductor and independent board for 16 Amps switch/ socket point as directed.
M/s Kohli Builders
M/s Raghav Traders
POONAM ELECTRIC INDUSTRY
Jyoti enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .