| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹17.3 L (11.8%)Admitted-Finance | ₹1.6 Cr+₹17.3 L (11.8%) | L2 | Admitted-Finance |
| 3 | L3₹1.9 Cr+₹40.1 L (27.3%)Admitted-Finance PUNE | PUNE | MAHARASHTRA | 410301 | ₹1.9 Cr+₹40.1 L (27.3%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Real Electricals L2 | Suvarna Electricals Pvt Ltd L3 | BBP Electricals L1 |
|---|---|---|---|---|---|---|
| 1.00Please note that Quoted rates are inclusive of taxes,labor,transportation, royaltie etc. Nothing Extra shall be paid separtely. | ||||||
| 2.00 | Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 150 Sqmm Armoured Aluminium (A2XFY) Cable. | 100 | RMT | 902.15 ₹90,215 | 729 ₹72,900 | 709 ₹70,900 Lowest |
| 3.00 | Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable. | 100 | RMT | 491.49 ₹49,149 | 396 ₹39,600 | 386 ₹38,600 Lowest |
| 4.00 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable. | 100 | RMT | 616.88 ₹61,688 | 498 ₹49,800 | 485 ₹48,500 Lowest |
| 5.00 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 4 sqmm copper armoured cable | 450 | RMT | 273.97 ₹1,23,286.5 | 222 ₹99,900 | 215 ₹96,750 Lowest |
| 6.00 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 C X 2.5 sqmm copper armounred cable | 250 | RMT | 201.47 ₹50,367.5 | 163 ₹40,750 | 158 ₹39,500 Lowest |
| 7.00 | Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 C X 1.0 sqmm copper aremounred cable | 200 | RMT | 90.33 ₹18,066 | 73 ₹14,600 | 71 ₹14,200 Lowest |
| 8.00 | Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 120 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable. | 100 | RMT | 1,333.61 ₹1,33,361 | 1,387 ₹1,38,700 | 1,310 ₹1,31,000 Lowest |
| 9.00 | Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 70 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable. | 1,000 | RMT | 751.79 ₹7,51,790 | 781 ₹7,81,000 | 738 ₹7,38,000 Lowest |
| 10.00 | Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge.
3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable. | 100 | RMT | 49.53 ₹4,953 | 57 ₹5,700 | 25 ₹2,500 Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
21 Sept 2022, 3:00 pmClosed
DIRECTOR IISER PUNE
IISER Pune Dr Homi Bhabha Road IISER Pune Pashan 411008
ANNUAL MAINTENANCE AND MINOR ELECTRICAL WORKS AT NON RESIDENTIAL BUILDING OF IISER PUNE CAMPUS
2022_IISRP_708991_1
05/ IISER/PUNE/2022 23
Open Tender
Electrical Works
Works
365 days
IISER PUNE
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
DIRECTOR IISER PUNE
₹3.5 L
online /Engg section IISER Pune
13 Oct 2022
29 Aug 2022
22 Sept 2022
29 Aug 2022
21 Sept 2022
30 Aug 2022
8 Sept 2022
Amount
Please note that Quoted rates are inclusive of taxes,labor,transportation, royaltie etc. Nothing Extra shall be paid separtely.
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 150 Sqmm Armoured Aluminium (A2XFY) Cable.
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable.
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 4 sqmm copper armoured cable
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 C X 2.5 sqmm copper armounred cable
Supplying LT cable having copper conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 C X 1.0 sqmm copper aremounred cable
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 120 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.
Supplying LT cable having copper conductor XLPE insulated sheathed, galvanized steel tape unarmoured cable with pvc outer sheathing 1.1 KV class ( Conforming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour , Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 1 Core x 70 Sqmm FRLS Heavy Duty unarmoured Copper (CuYY) Cable.
Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm Armoured Aluminium (A2XFY) Cable.
Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.
Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 4 sqmm
Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 C X 2.5 sqmm
Laying of 1 no. of mentioned XLPE cables of 1.1KV grade direct on existing cable tray ,in trench including tying of cables neatly with nylon tape and labeling etc, as required. Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 C X 1.0 sqmm
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 70 Sqmm (A2XFY) XLPE AL. AR. Cable.
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core x 10 Sqmm Armoured Copper Cable.
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 4 Core X 2.5 YWY Cu Armoured Cable
END TERMINATION: Supply and installation of End termination of cables with compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 2 Core X 1.0 YWY Cu Armoured Cable
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays cross members with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays cross members with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays reducer with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm Width x 50mm depth x 1.6mm thick.
PERFORATED TYPE CABLE TRAYS : Supplying and installing following size of perforated painted with powder coating M.S. cable trays reducer with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm Width x 50mm depth x 1.6mm thick.
FINAL DISTRIBUTION BOARDS. PART - C - DB's & MCB's : Supply, Installation, Testing and Commissioning of all MCB Distribution Boards (10KA) 415V, made out of 16SWG MS sheet steel enclosure hinged MS cover/over flanged cover (double door) with cutouts for operating the MCB knobs and comprising of phase bus bars, neutrals and earth bus with tapped holes, bakelite phase barriers, pvc insulator shoes for incoming wire, etc complete. DB's shall be mounted by grouting in to the wall/angle to brick wall as required. DB's shall be suitable for Three Phase / single phase loads. Or DB's shall be mounted on suitable M.S. angle and supporting flat. DB's shall include termination lugs etc., all complete. (Note: Local fabrication not permitted. Only factory made boxes shall be installed and all MCB's shall be with 10 KA rating)Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 8 way (4 + 24), Double door for RPDB
FINAL DISTRIBUTION BOARDS. PART - C - DB's & MCB's : Supply, Installation, Testing and Commissioning of all MCB Distribution Boards (10KA) 415V, made out of 16SWG MS sheet steel enclosure hinged MS cover/over flanged cover (double door) with cutouts for operating the MCB knobs and comprising of phase bus bars, neutrals and earth bus with tapped holes, bakelite phase barriers, pvc insulator shoes for incoming wire, etc complete. DB's shall be mounted by grouting in to the wall/angle to brick wall as required. DB's shall be suitable for Three Phase / single phase loads. Or DB's shall be mounted on suitable M.S. angle and supporting flat. DB's shall include termination lugs etc., all complete. (Note: Local fabrication not permitted. Only factory made boxes shall be installed and all MCB's shall be with 10 KA rating)Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required 4 way (4 + 18), Double door for UPS DB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) * 8 way double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) * 12 way double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Emergency Lighting DB - ELDB - 1 Phase 8 Way, suitable to install the following excluding MCB / RCBO, 'Incoming: 1 No. 32A DP RCBO, 30mA, Outgoings: 4 Nos. 10 A SP MCB, 'B' curve.
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 63 A, 4P, 30mA
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40 A 4P, 30mA
Supplying fixing and wiring Current Operated RCBOs,240V/415V 50Hz with 10KA short circuit with standing capacity 25amps. double pole, 30/100mA, and Including the cost of all materials, lobour, HANDLING OF MATERIALS of equipment and machinery all lead lift, loading etc, complete.RCBO 32/40A, DP, 30mA
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete 32/40 A TPN MCB
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete 32 A TP MCB
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete 16 / 20A, SP, MCB - 'C' CURVE for RP & UPS DB's
Supplying and fixing, MCB on existing MCB distribution boards using necessary fixing materials and wiring complete as required and Including the cost of all materials, lobour , HANDLING OF MATERIALS of equipment and machineries all lead lift, loading etc, complete 10A, SP, MCB - 'B' CURVE- for LDB & ELDB
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TPN sheet steel enclosure on surface/ recess without MCB complete with connections, testing and commissioning etc. as required.
Supply and fixing MCCB incomer box with 250 A MCCB 4P 50kA
PVC RACEWAYS ( Along the wall) DLP U- PVC adaptable trunking : Supply & installation of surface mounted DLP U- PVC adaptable trunking raceways, fabricated out of U-PVC to Off-White or approved shade as per IS 733 of thickness 2.0mm for the base and sides with removable covers, complete with necessary bends, suitable sized junction boxes, internal angle, external angle, flat 90 degree angle , end caps and tees,minor civil works if any etc, Complete. (For every 1mtr distance cable tag has to be provided for each circuit in the raceways - as more that 1C FRLS copper wire is required for 1 Circuit) PVC RACEWAYS ( Along the wall), DLP U- PVC adaptable trunking . Size: 105x 50mm PVC Raceways for Power & Data with above specifications 105x 50mm PVC Raceways
16 AMP SOCKET: Supplying and fixing following Modular socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required. . 6 Pin 15/16 amp socket outlet
13 AMP SOCKET: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 13 amp socket outlet
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. . 15/16 amp switch
16 AMP Switch: Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as requiredincluding connections, as required. . 5/6 amp switch
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 6 Module Box with faceplate & cover
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 4 Module Box with faceplate & cover
Supplying and fixing following Modular switch / socket on the existing raceways & PVC DLP truncking with required accessories to complete jobs. including connections, as required including connections, as required. . 1/2 Module Box with faceplate & cover
INDUSTRIAL POWER SOCKETS on wall : 32Amp, single phase : Supply and fixing 32A, 3 pin, Single phase, Industrial Socket with safety shutters controlled by One no. of 32A, double Pole MCB to be mounted on wall, ( The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) As per IEC 61439-3. suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. Including the cost of all materials, lobour , HOM of equipment and machinerys all lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. MCB/PLUG/BOX -32A . Make:-
INDUSTRIAL POWER SOCKETS on wall : 32Amp, three phase : Supply and fixing 32A, 5 pin, three phase, Industrial Socket with safety shutters controlled by One no. of 32A, three Pole MCB to be mounted on wall, ( As per IEC 61439-3. suitable for flush mounting and surface mounting. 3P+ P+E Five pole, IP 44, material of plug & socket polyamide 6. The job includes cutting & chasing on exisiting wall, fixing the box in position as required including rough plastering.) Including the cost of all materials, lobour , HOM of equipment and machinerys all lead lift, loading and unloading,transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. MCB/PLUG/BOX - 32A
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
Light Point Wiring : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessedmedium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
POWER SWITCHES / SOCKETS on walls - G.I. BOX. : Supplying and fixing following size / modules, GI box along with modular base and cover plate for modular switches in recess etc, as required. ( The job includes cutting & chasing existing wall, fixing the box in position as required including rough plastering.) (In all the rooms, vertical drops of conduits and switch boxes shall be concealed in the wall). Boxes should be of same make as that of modular accessories. :6 Module
LIGHT CIRCUIT WIRING : Wiring for circuit / submain wiring in concealed pipe below false ceiling (by chieseling the wall and covering with chicken mesh with rough plastering) / surface mounted. Including ISI mark PVC Conduit with 25mm DIa of 2mm thick with PVC insulated FRLS single core wires with colour code of following: 2 x 2.5 sqmm + 1 x2.5 sqmm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 25mm dia conduit pipe (2mm) -
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 32mm dia conduit pipe (2mm) -
Supply of Recessed/Surface Mounted 2'X2' , 36 / 40 W LED Luminaire Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 2'X2' Luminaire.Luminaire should be available in different Lumen Packs of 4000 lm with different CCT.. LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100 lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Make Wipro / Crompton / Havell / Bajaj
ERECTION for Recessed/Surface Mounted 2'X2' , 36 / 40 W LED Luminaire incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply of Recessed/Surface Mounted 12 watt LED Luminaire round/squre dia 165 mm cut out type with Intelligent Inner Edge Light with Single piece molded Polycarbonate diffuser, Lighting and electrical parameters are inline with 1'X1' Luminaire. Luminaire should give more volumetric light & higher vertical illumination.Luminaire should be available in different Lumen Packs of 1200 lm with different CCT, maximum system wattage of 12 W, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95 and SDCM 4 for good light quality, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters Make Wipro / Crompton / Havell / Bajaj / syska
ERECTION for Recessed/Surface Mounted 12 watt LED Luminaire round/squre dia 165 mm cut out type incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply surface mounted 20W LED batten type fitting complete with all accessories Including the cost of all materials, labour, HOM of equipment and machinerys all lead, lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. The fitting shall be green as per ECBC norms. .Make Wipro / Crompton / Havell / Bajaj
ERECTION for surface mounted 20W LED batten type fitting incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply of reccess/ surface mounted 9 watt 5" LED Recessed Downlighter with a nominal system lumen output of 600 lumens and a minimum system efficacy of 110 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF > 0.95 and 2.5KV surge protection. The luminaire housing should made of pressure die cast aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The total power consumption should not exceed 5.5W (including driver).The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007. Make Wipro / Crompton / Havell / Bajaj
ERECTION for reccess/ surface mounted 9 watt 5" LED Recessed Downlighter incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supplying and fixing exhaust fan of 1440 RPM of 305 mm (12") sweep with bracket blades complete for light duty of approved make. Louvers are required for each fan with 230V, single phase, 50 Hz. Including the cost of all materials, labour , HOM of equipment and machinerys all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-incharge. Frame for installation will be under civil scope of works.
ERECTION for exhaust fan of 1440 RPM of 305 mm (12") sweep incluilding wall maounting arragement, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, nutbolts / fasners etc with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
50 mm X 5 mm copper earth strip : Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc, as required.
25 mm X 5 mm copper earth strip on surface: Providing and fixing 25 mm X 5 mm copper stripfrom earth electrode as required.
25 mm X 5 mm GI earth strip on surface: Providing and fixing 25 mm X 5 mm GI strip from earth electrode as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.2 run of cable
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required ( for Data cable ) 40 MM
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required ( for Data cable ) 25 MM
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At field side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply and making end termination for UTP 4 pair CAT 6 LAN cable with required IO modules which is suitable for modular type base , cover plates and accessories ( At Rackside side ) as required.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐charge. Nothing extra shall be paid separately.
Supply of 2meter length cat 6 patch cord with Rj 45 terminations on both ends as complete.
Supply and installation of 48 port fully loaded patch panel with IO modules suitable for UTP CAT 6 cable and required mounting accessories for existing network rack.Quoted rate shall be including material, labour, taxes, duties, lead, lift, loading, transportation, unloading, storing , scaffolding etc, making holes in walls , filling holes with mortar etc complete as per direction of Engineer In‐ charge. Nothing extra shall be paid separately.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
EARTH BUS : Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Suuply and installation of 3KW water Heater 1.25'' BSP TP 18'' long
Suuply and installtion of thermostat 11'' long suitable for 3KW 1.25'' BSP TP 18'' long water Heater
Providing excavation and refilling of existing earthing pit GI / Copper with Charcoal 90 Kg , solt 30 kg each. Works includes cleaning of all GI/ Copper parts of earthing pit, replacement of connecting nutbolts with new SS nutbolts, replacement of water pipe GI having identical specifications with existing one, if required. Reconstruction of earthing chamber with 450 x 450 size CI cover. Earthing test report should be submitted by the agency as per format issued by IISER Pune. Before execution of work, prior approval from engineer in charge, IISER Pune is required. Work shall be executed as good workmenship.
Repairing and reconstruction of earthing chamber with CI 450 x 450 mm cover , as per instructions of Engineer in charge, IISER Pune
Supplying LT cable having Aluminium conductor XLPE insulated sheathed,galvanised steel tape armoured cable with pvc outer sheathing 1.1 KV ( Confirming to IS 7098 Part-II amended upto date as per the following sizes). Including the cost of all materials, lobour, Handling of materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 25 Sqmm Armoured Aluminium (A2XFY) Cable.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
Supply and installation of End termination of cables with double compression brass cable glands, Al crimping type lugs should be used for Al cables and Cu lugs with soldering and ferrules for the following 1.1kv class Al./Cu. XLPE/PVC insulated using necessary crimping tool and all other accessories as required and Including the cost of all materials, lobour, Handling of Materials of equipment and machineries all lead lift, loading and unloading, transportation, if any other incidental charges at all level complete all as per specification and as directed by Engineer-in charge. 3.5 Core x 25 Sqmm (A2XFY) XLPE AL. AR. Cable. 3½ X 25 sq. mm (28mm)
ERECTION for surface mounted 20W LED batten type fitting incluilding ceiling hook, drop wires 3 R x 1.5 sqmm copper flex wire from ceiling point to fitting with full covered flex pipe, stray wire / cable for handing fitting on false ceiling or mouting on ceiling with surface box assembly etc as required and complete. Cutting in metal / false ceiling for required cut out is in scope of agency.
Supply, installation, testing and commissioning of Chemical earthing using electrode of size 76 mm minimum diameter, minimum 03 meter long and connected with 50x5 mm copper internal strip, material of conustruction COPPER, complete with existing excavation / bore, civil work for chamber, cast iron cover size 450 x 450 mm, with backfill compound as requred to fill earth pit up to mark. the earth resistance shall be as per IS 3043
Providing boreing / drilling bore well of 150mm dia for casing / strainer pipe , by suitable method, including drilling in all strata, including hiring & running charges of all equipments, tools, plants and machinenaries required for the job, all complete as per direction of Engineer in charge.
Supply of Ceiling fan 1200 mm sweep, aerodynamic design, complete set with condenser, stator, rotor, three blades , down rod, two caps , mounting hooks, nutbots, connectors etc. 60 W, 230 V AC
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supply of 350 mm exhaust fan, industrial type with condender and mounting arrementment, wattage 50 W, 230 V AC, as complete.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep
Supply of wall mounted fan with 400 mm sweep, 50 W, oscillatioing movement, 3 three regulator, mounting arragement, hi flow air, 230 V AV, as complete.
Supply of pedestal fan with 400 mm sweep, 50 W, oscillatioing movement, 3 three regulator, mounting arragement, hi flow air, 230 V AV, as complete.
Real Electricals
Suvarna Electricals Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.30 MB
Tenderdocuments.pdf
Tender Documents • 4.95 MB
BOQ_745916.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .