Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹1.9 CrAccepted-AOC | ₹1.9 Cr Quoted ₹2.0 Cr | L 1 | Accepted-AOC Lowest One work order issued on 19.12.2022 |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
5 Oct 2022, 6:00 pmClosed
Superintending Engineer South Circle TNPHC Ltd.,
Tamil Nadu Police Housing Corporation Limited South Circle, No.1 Inspector quarters TSP VI Battalion Campus, New Natham Road, Madurai-14
Construction of building for Fire and Rescue Services Station with development works at KADAMALAIKUNDU in Theni District (Re-tender)
2022_TNPHC_253028_1
SE/SC.No.33/2022-2023-2
Open Tender
Civil Works
Lump-sum
335 days
KADAMALAIKUNDU IN THENI DISTRICT
Refer tender documents
7 documents required · 7 mandatory
₹0
₹1.2 L
20 Dec 2022
24 Sept 2022
7 Oct 2022
24 Sept 2022
5 Oct 2022
24 Sept 2022
Amount
1.1) Earth work excavation for foundation in all soils (including refilling) a. 0 to 2 mt.
1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.6) Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 mt.
2.6) Supplying and filling with 40mm HBSJ
2.7) Supplying and filling with 20mm HBSJ
13.1) Filling with excavated earth
21.2) Teak wood Wrought & Put up a. T.W. over 2.00 m & below 3.00 m
b. T.W. below 2.00 m length.
23.3) Supplying and fixing of Magnetic door catches
24) Manufacturing & supply of steel windows (weight basis)
25) Supplying and fixing of MS hold fast
30) Ellispattern flooring
31) Weathering course over roof slab with proportion of brick jelly 20mm to lime (32:12 1/2) by volume
37.1) White washing 3 coats (slaked)
39) Supplying and fixing of MS Grills in position
40) Painting 2 coats - New "wood work"
41) Painting 2 coats - New "iron work"
46) Supplying and fixing of 20 mm dia Alu. Hanger Rod
47) Supplying and fixing of Alu. Towel rail 75 cm long
48) Supplying and fixing of 5 pin Coat stand
49) Supplying and fixing of Chromium plated 8 gauge picture hook
50.3) Supplying and planting avenue trees
50.4) Providing Tree guard
52) Supplying and laying of PVC Water supply (ASTM) pipe a. 32 mm dia
b. 25 mm dia
52.1) Supplying and fixing of G.I. Pipe 20mm dia for hot water line (Fully concealed in walls)
53.3) Supplying and fixing of C.I. steps (5 Kg)
55.2) Supplying and fixing of Flat Back Urinal with Accessories
Electrical arrangements 69) Supplying and fixing of 15 Amps 3 pin Power plug socket
72) Supplying and fixing of Box type Fibre Fan hook
73.2) Supplying and fixing of 3 phase Distribution board with 4 way per phase 32A per way with neutral link
74) Charges for assembling and fixing of ceiling "Fan"
76) Supplying and fixing of 8 SWG G.I. wire
77.3) Supplying and fixing of TV/Telephone line Socket
77.4) Supplying and fixing of 20mm dia PVC pipe for TV/Telephone line
78) Providing Earthing Station using pipe electrode as per IS3043 (Type I)
81) Supplying and fixing of meter cupboard with best Country wood double leaves shutters
86) Providing Pre-constructional Anti termite treatment
Annexure 2.1.2) Supplying and filling the basement with well gravel
2.1.3) Supplying and filling in foundation and basemnet with Crushed stone sand
2.1.6) Supplying of Stone dust
3.1.1) C.C.1:5:10 using 40mm size HBSJ for Foundation & Basement using crushed stone sand
3.2.1) P.C.C. 1:2:4 using 20mm size HBSJ for Foundation & Basement and other similar works using crushed stone sand
3.10.1) P.C.C. 1:3:6 for vertical wall with 20mm HBG Metal using crushed stone sand for foundation and basement
4.4.1) Standardized Concrete mix M20 Grade using crushed stone sand a. In Foundation and basement
6.6.1) Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture
8.4.1) Standardized Concrete mix M20 Grade using crushed stone sand a. In Ground Floor
b. In First Floor
c. In Second Floor
9.6.1) Brick work in C.M. 1:6 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼ " x 2 ¾ ") using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
c. In Second Floor
10.6.1) Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7 cm (8 ¾"x4 ¼ "x2 ¾") 110 mm tk (B.P.) using crushed stone sand with Admixture a. In Foundation and basement
b. In Ground Floor
c. In First Floor
11.6.1) Brick work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼ " x 2 ¾ ") 70 mm tk using crushed stone sand with Admixture (B.P.) a. In Ground Floor
b. In First Floor
12.1.1) Brick partition work in C.M. 1:4 using kiln burnt Country bricks of size 22 x11x 5 cm (8 ¾ "x 4 ¼ "x 2 ") 50mm tk. using crushed stone sand with Admixture a. In Ground Floor
b. In First Floor
14.2.2) Precast Cupboard slab 20mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand 20mm thick a. In Ground floor
b. In First floor
14.2.3) Precast Cupboard slab 40mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand 40mm Thick a. In Foundation & Basement
b. In Ground Floor
c. In First Floor
16.1.1) Precast Jally ventilator 50mm thick using standardised concrete mix M20 Grade using crushed stone sand a. In Ground Floor
b. In First Floor
18.1) Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works
c. For Square and rectangular columns and small quantities
d. For Vertical wall
f. For Curved surface
g. Double centering
21.5.2) Supplying and fixing of soild UPVC door shutter with frame
21.5.5) Supplying and fixing of UPVC Sliding window a. 0.90 x 1.65 mt. window (Two track)
21.5.6) Supplying and fixing of UPVC Sliding window a. 1.50 x 1.65 mt. window (Three track)
22.3.3) Cup board/ward robes double leaf shutters using 9mm thick phenol bonded BWR grade plywood, TW frames, styles & rails including two coat enamel paint over one coat primer with brass screws
22.9.3) Supplying and fixing of Solid core flush door shutters with Teak ply on both sides and TW lipping alround (35mm thick) single leaf shutter Suitable for door of size a) 1200 x 2400mm
23.2.1) Supplying and fixing of 4mm thick pin headed glass panels with Aluminium beedings
26.1) Flooring in C.C.1:5:10 using 40mm size HBSJ using crushed stone sand
28.1) Floor plastering in C.M. 1:4, 20mm thick. using crushed stone sand
29.8.1) Supplying and fixing of Glazed tiles using Grout (Tile Joint Filler) using crushed stone sand
29.9.1) Supplying and laying of Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler). using crushed stone sand
32.1.1) Pressed tiles (23cmx23cmx20mm thick) mixed with water proofing compound @ 2% by weight of cement using crushed stone sand
33.1) Plastering in C.M. 1:5, 12 mm tk. using crushed stone sand
34.1) Plastering in C.M. 1:4, 12 mm tk. using crushed stone sand
35.1.1) Plastering in CM 1:3, 12 mm tk. with WPC using crushed stone sand
35.2) Spl. Ceiling plastering in C.M 1:3, 10 mm tk. using crushed stone sand
36.1) Plastering for Border in C.M. 1:5, 12 mm tk. using crushed stone sand a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.4.1) Two coat of Oil Bound Distemper over the primer coat of white cement
38.4.2) One coat of Wall putty over the new cement plastered walls
38.6) Primer coat using one coat of white cement over the cement plastered/ concrete new wall surfaces or other similar works
43.1) Supplying, Fabricating and fixing of Mild steel / RTS grills (without cement slurry wash) reinforcement for all sizes of rods
44.2.1) Rain water harvesting using defunct borewell and providing perforated cover slab in Standardised concrete mix M20 Grade by using 3mm-10mm HBGS Jelly using crushed stone sand a) Providing pit
b) Augering 30cm dia
44.3) Providing Rain water Harvesting Well ring of Circular shape of 90cm dia, 60cm depth using Standardised mix design M20
44.6) Supplying and fixing of PVC SWR 110 mm dia with ISI mark type-A for rain water down fall pipe
50.2.1) Providing precast Kerb stone in C.C. 1:3:6, 450x300x150 mm using crushed stone sand
50.5.1) Supplying fabricating and erection of M.S Scheme name board using crushed stone sand
50.6.1) Precast slab 50 mm tk.in C.C. 1:3:6 mixed with fibre using crushed stone sand
51.2) Supplying and fixing of white FRP / PPFRP Sintex triple layer water tank 1500 litre capacity
52.4) Supplying laying fixing and jointing the following PVC pipes as per ASTM D-1785 of schedule 40 threaded PVC water supply ASTM pipe (fully consealed in walls) with necessary PVC/GI specials c. 20mm dia
53.4) Supplying and fixing of CI Manhole cover of size 60 x 60cm (50kg weight)
53.5) Supplying and fixing of porcelin Wash hand basin (White without Pedestal Type), superior variety of size 550x400mm (22”x16”)
54.1.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (long body)
54.2.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (Short body)
56.3.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade 'P' or 'S' trap - in G.F. using crushed stone sand
56.4.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade 'P' or 'S' trap - Other than G.F. using crushed stone sand
56.4.4) Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet
57.2) Supplying and fixing of EWC (White) 500mm with PVC SWR grade "P" or "S" Trap
58.3) Supplying and fixing of PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia
58.4) Supplying, Laying & Concealing the 50mm dia PVC (SWR) pipe with ISI mark type - 'B' with relevant specials.
58.5) Supplying and fixing of PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl a) 110mm dia PVC SWR pipe of 3m with required PVC cowl & PVC specials etc.,
60.1) Supplying and fixing of PVC Nahani trap (4way/2way)
61.1.1) Supplying and fixing of UPVC Non Pressure Pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a) 110mm dia UPVC Non Pressure pipe
b) 160mm dia UPVC Non Pressure pipe
62.1.1) Supplying and fixing of PVC Bend fabricated 6 KSC PVC specials as per IS 10124/1982 Part II a) 110mm dia PVC Bend
b) 160mm dia PVC Bend
62.2.1) Supplying and fixing of PVC Equal Tee (mould) BIS 7834/1975 PVC specials as per IS 10124/1982 Part-II a) 110mm dia PVC Equal Tee
b) 160mm dia PVC Equal Tee
64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan Point
66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Switch Board Itself.
68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Convenient Places.
71.2) Supplying and fixing of 32 Amps triple pole main switch
75.1.2) Supplying and delivery of fan with electronic dimmer with ISI mark a) 48" (1200mm) sweep
77.5) Run off 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed
77.6) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed.
77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed
79.1.1) Supplying and fixing of 1 No. of 32 Amps Fuse Unit
79.2.1) Supplying and fixing of 3 Nos. of 32 Amps Fuse Unit
80.1) Supplying and fixing of 450x375x20mm T.W. plank
84.4) Run of Main 4 wires of 6 Sqmm PVC insulated unsheathed single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
85.1) Supplying of G.I pipe 40 mm dia, 'B' class
87.1) Supplying and fixing of Three Phase ELCB/RCCB
99.4) T.W.double leaves Panelled door shutter with brass fittings Suitable for door of size a. 1800 x 2400mm
100) Supplying and fixing of 9 watts LED Bulb
101) Supplying and fixing of 25 watts LED bulb with street light fittings
102) Supplying and fixing of 4'18 watts crystal LED tube light
103) Supplying and fixing of Bulk Head fitting suitable for 12 watts LED Lamp
104) Supplying and fixing of 12 watts LED lamp for bulk head fittings
109) Supplying and fixing of 40 Amps 30 MA RCCB / ELCB (Four Pole)
110) Supplying and fixing of Single Pole MCB 6A to 32A, 10KA
112.1) Supplying and fixing of Exhaust Fan 225mm dia
114) Supplying and delivery of 3.5 core 35 Sqmm PVC Aluminium armoured LTUG cable
115) Labour charges for laying of 3.5 core 35 Sqmm PVC Aluminium armoured LTUG cable below ground level
116) Labour charges for laying of 3.5 core 35 Sqmm PVC Aluminium armoured LTUG cable above ground level
117) Supplying and fixing of 3.5 core 35 Sqmm Brass cable Gland suitable for PVC Aluminium armoured LTUG cable
119) Supplying and delivery of 5 HP clear water vertical wet type submersible pumpset three phase suitable for borewell Duty -50 lpm x 175 m
119.1 ) Supplying and delivery of 2 HP Monoblock pumpset Duty - 450 lpm x 20 m
120) Labour charges for erection of submersible pumpset in borewell upto 5 HP
120.1) Labour charges for erection of Horizontal shaft, Centrifugal pumpset upto 3 HP (coupled/monoblock)
121.1) Supplying and delivery of three phase panel board of direct online starter with two level guard and auto start (5 HP)
121.2) Supplying and delivery of Direct online starter with single phasing preventor 2 HP for Monoblock motor
122) Supplying and fixing of following dia GI, CI & GM specials a) 50 x 40mm dia GI Reducer Tee
b) 50 mm dia GI Coupling
c) 50mm dia GM Gate valve (Heavy Duty)
d) 50mm dia GM Non-return valve
e) 50mm dia GI Union
f) 50mm dia GI Hex Nipple
g) 50mm dia CI foot valve with stainer
h) 50mm dia GI Tee
i) 50mm dia GI Bend
j) 32mm dia GI Union
k) 32mm dia GI Elbow
l) 32mm dia GI Hex Nipple
m) 25mm dia GI Coupling
123) Supplying and Delivery of 3 core of 4 Sqmm flat type copper cable
124) Supplying and delivery of following dia GI pipes 'B' class in position a) 25mm dia GI pipe
b) 40mm dia GI pipe
c) 50mm dia GI pipe
125) Supplying and delivery of following dia PVC Pipe a) 50mm dia PVC pipe/10 Kg/cm2
b) 32mm dia PVC pipe/10 Kg/cm2
125.1) Labour charges for laying of GI and PVC pipe below ground level
125.3) Supplying and delivery of 32mm dia UPVC pipe
126.1) Supplying and fixing of 65mm dia M.S.Clamp set
127) Supplying and delivery of Nylon rope for tieing of submersible motor pump
129.1) Supplying and fixing in position of Aluminium die casting TNPHC Logo emblem a) 60 cm size
130) Supplying and fixing of Aluminium Dye cast letters a) Aluminium Dye Cast letter 9" size
b) Aluminium Dye Cast letter 6" size
132.1) Drilling of 150mm dia borewell in alluvial soil including labour charges for inserting casing pipes and including cost of Rig, Fuel etc.,
133) Supplying of 150mm dia PVC Casing pipe shallow depth
134) Supplying and fixing of 160mm dia PVC end cap for covering the borewell etc.,
140) Supplying of 3 to 10mm size HBS jelly etc.,
142) Supplying and delivery of 83mm thick Rubber Moulded Hydraulic pressed Paver block
143) Labour charges for spreading and levelling of 3mm to 10mm size HBSJ and stone dust and compaction by the earth rammer and laying Paver block including Machienry charges
144) Supplying and fixing of CP Shower Arm with Overhead Shower Rose
145) Supplying and fixing of CP Two Way Bib Cock with Health Faucet
146) Supplying and fixing of CP Angle Cock Tap
147) Supplying and fixing of PVC Trims (Beading)
159) Metering Panel for 4 services (2 Flats + 1 Common & 1 Spare) 2 in 1 (G+1)
163) Supplying and fixing of 63 Amps TPN switch Disconnector fuse units in sheet steel enclosure with HRC fuses double break
344.2) Supplying and fixing of Bevelled Edge Mirror of size 500x400x5.5mm
361.1) Supplying and laying of Concrete designer tiles flooring in C.M. 1:3 (one of cement and three of crushed stone sand) 20mm thick
367) Providing wooden melamen polish for main door new wood work
378.2) Supplying and fixing of Vitrified tiles (Ivory) in CM 1:3, 20mm tk using crushed stone sand
448.2) Providing Tee with end cap 32mm dia instead of PVC Bottle trap
796) Two coat of Plastic emulsion paint including primer for outer wall surfaces
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_299457.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .