GEMC-511687711515262
Awarded to Biogen Scientific
₹1.3 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FUME HOOD CHAMBER | BIOGEN BGS-143(A) | - | 1 NOS | ₹1.3 L | 130,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.3 LQualified Make: Biogen
Model: BIOGEN BGS-143(A) 323 324 KRISHNA PLAZA GARH ROAD TEJGARHI CROSSING MEERUT UTTAR PRADESH 250004 | MEERUT | UTTAR PRADESH | 250004 | Make: Biogen
Model: BIOGEN BGS-143(A) | ₹1.3 L | L1 | Qualified |
| 2 | Disqualified Make: National
Model: NATIONAL 00 SATANPUR SULTANPUR UTTAR PRADESH 228001 | SULTANPUR | UTTAR PRADESH | 228001 | Make: National
Model: NATIONAL | - | - | Disqualified |
| 3 | Disqualified Make: NA
Model: HORIZONTAL LAMINAR AIR FLOW (M.S) 308 ISCON ARCADE OPPOSITE CHOICE SNACK BAR C G ROAD NAVARANGPURA AHMEDABAD CITY GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: NA
Model: HORIZONTAL LAMINAR AIR FLOW (M.S) | - | - | Disqualified |
| 4 | Disqualified Make: NA
Model: Make - Rescholar, Model No. - RH-58-11 85 PROP M S RESCHOLAR EQUIPMENT INDUSTRIAL AREA AMBALA CANTT HARYANA 133001 | AMBALA | HARYANA | 133001 | Make: NA
Model: Make - Rescholar, Model No. - RH-58-11 | - | - | Disqualified |
| 5 | Disqualified Make: MS SCIENTIFIC
Model: M S Scientific FUME HOOD PA001 23 BAJRANG VIHAR CHAPOLA KI DHANI SANGANER JAIPUR RAJASTHAN 302029 | JAIPUR | RAJASTHAN | 302029 | Make: MS SCIENTIFIC
Model: M S Scientific FUME HOOD PA001 | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Jun 2018, 4:00 pmClosed
fume hoods for laboratory with cubboard Fume Hoods For Laboratory With Cubboard ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values DIMENSIONS
FEATURES Size of Sink (mm) 300 - Power Rating - - Drawing No. - - Product Code available on Web - - Safety Device Trip (Nos) - - Material of Base Cabinet - - Working Platform Material - - Double wall Construction Yes - Ducting Material - - Details of Electrical outlets - - Product Code No - - Air Flow (Cubic metre/hr) 100 - Width of Base Cabinet (mm) 300 Material of Front Toughned Float Glass Toughned Float 1/4 shutter Glass
other Overall lenth of Fumehood (mm) 600 Base Cabinets With With
Without Ducting for hood With With
Without Efficiency & Noise level of Blower (%
dB) - - Thickness of wall (mm) 10 Operating Temperature of Fumehood (°C) 50 - Material of Fumehood - - No. of Drawers in the Base Storage Unit (Nos) 0 0
1
2
3
4
5
6
7
8
9
10 Fumehood installation Kit and Accessories With With
Without Height of Base Cabinet (mm) 600 Type of Filter - - Type of Fumehood Laboratory - Length of Base Cabinet (mm) 1200 Fire Resistant false Utility Pipe lines for Nitrogen
Compresse d Air & Water etc. true Face Velocity (m/s) 0.45 - Type of Fumes suitable for - - Overall Width of Fumehood (mm) 600 - Design of base Cabinet - - Wattage of Blower (W) - - Material of sink - - Overall Height of Fumehood (mm) 600 - Type of Blower - Design details of baffles - - Design details of Electrical Services - - 2/4 No. of Electrical Socket and Switch (Nos) - - Material of the Blower - - Working Platform Thickness (mm) - - Provision of Electrical Outlets true Drawing available on Web false Features of various Utilities - - CONFIGURATION Fumehood Baffles With With
Without Front shutter Fumehood With With
Without Material of Insulation - - Type of Base cabinets Movable with Wheels Movable with Wheels
Movable without Wheels Non Corrosive treatment of inside compartment true - Availability of Sink With With
Without No. of Shutters (Nos) 1 1
10 No. of Shelves in Base storage units (Nos) 1 1
10
0 Materials of Baffles - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 S Zangkhohao Mate 500048
Plot 366/1
Near Pillar No 162 left side Freshwater Biology Regional Centre Zoological Survey of India Hyderguda Attapur Hyderabad 1 15 EMD Required No ePBG Required No 3/4
150865
GEM/2018/B/21523
GeM Contract
fume hoods for laboratory with cubboard
GeM Contract
15 days
Telangana; Ranga Reddy
PRODUCT
Awarded to Biogen Scientific
₹1.3 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| FUME HOOD CHAMBER | BIOGEN BGS-143(A) | - | 1 NOS | ₹1.3 L | 130,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| fume hoods for laboratory with cubboard Fume Hoods For Laboratory With Cubboard ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values DIMENSIONS | - | - | - |
| FEATURES Size of Sink (mm) 300 - Power Rating - - Drawing No. - - Product Code available on Web - - Safety Device Trip (Nos) - - Material of Base Cabinet - - Working Platform Material - - Double wall Construction Yes - Ducting Material - - Details of Electrical outlets - - Product Code No - - Air Flow (Cubic metre/hr) 100 - Width of Base Cabinet (mm) 300 Material of Front Toughned Float Glass Toughned Float 1/4 shutter Glass | - | - | - |
| other Overall lenth of Fumehood (mm) 600 Base Cabinets With With | - | - | - |
| Without Ducting for hood With With | - | - | - |
| Without Efficiency & Noise level of Blower (% | - | - | - |
| dB) - - Thickness of wall (mm) 10 Operating Temperature of Fumehood (°C) 50 - Material of Fumehood - - No. of Drawers in the Base Storage Unit (Nos) 0 0 | - | - | - |
| 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 | - | - | - |
| 6 | - | - | - |
| 7 | - | - | - |
| 8 | - | - | - |
| 9 | - | - | - |
| 10 Fumehood installation Kit and Accessories With With | - | - | - |
| Without Height of Base Cabinet (mm) 600 Type of Filter - - Type of Fumehood Laboratory - Length of Base Cabinet (mm) 1200 Fire Resistant false Utility Pipe lines for Nitrogen | - | - | - |
| Compresse d Air & Water etc. true Face Velocity (m/s) 0.45 - Type of Fumes suitable for - - Overall Width of Fumehood (mm) 600 - Design of base Cabinet - - Wattage of Blower (W) - - Material of sink - - Overall Height of Fumehood (mm) 600 - Type of Blower - Design details of baffles - - Design details of Electrical Services - - 2/4 No. of Electrical Socket and Switch (Nos) - - Material of the Blower - - Working Platform Thickness (mm) - - Provision of Electrical Outlets true Drawing available on Web false Features of various Utilities - - CONFIGURATION Fumehood Baffles With With | - | - | - |
| Without Front shutter Fumehood With With | - | - | - |
| Without Material of Insulation - - Type of Base cabinets Movable with Wheels Movable with Wheels | - | - | - |
| Movable without Wheels Non Corrosive treatment of inside compartment true - Availability of Sink With With | - | - | - |
| Without No. of Shutters (Nos) 1 1 | - | - | - |
| 10 No. of Shelves in Base storage units (Nos) 1 1 | - | - | - |
| 10 | - | - | - |
| 0 Materials of Baffles - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 S Zangkhohao Mate 500048 | - | - | - |
| Plot 366/1 | - | - | - |
| Near Pillar No 162 left side Freshwater Biology Regional Centre Zoological Survey of India Hyderguda Attapur Hyderabad 1 15 EMD Required No ePBG Required No 3/4 | - | - | - |
Exempted
13 Jul 2018
30 May 2018
contract_GEMC-511687711515262.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_150865.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .