Up gradation restoration maintainance operation of Trunk sewer line Laterals Manholes property chambers by way of removing blockeds in the existing sewer system in ward nos 14 32 civil maintainance upgradation of assets of UEED STP at Gole
2021_HAUDD_124604_1
ENIT NO 09 OF 2021-22
Open Tender
Civil Works
Item Rate
365 days
JAMMU
REFER ENIT
3 documents required · 3 mandatory
₹600
TREASURY RECEIPT
₹70,000
EXECUTIVE ENGINEER SD DIV WEST JAMMU
15 Jun 2021
18 May 2021
3 Jun 2021
18 May 2021
2 Jun 2021
18 May 2021
18 May 2021 - 23 May 2021
25 May 2021
Amount
Dismentaling tile work in floors and roofs laid in cement mortar including stacking material within 50m lead.
For thickness of tiles 10mm to 25mm
For thickness of tiles above 25mm &upto 40 mm
Dismentaling manually/mechanically including stacking of serviceable material & disposal of unserviceable material within 50m lead as per directions of Engineer in charge
Water bound macadam
Bituminous road
Demolishing RCC work by mechanical means and stocking at designated location & disposal of dismantled material upto a lead of 50 m stacking serviceable &unserviceable material separately including cutting reinforcement bars.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50m lead as per direction of engineer- incharge 1:3:6 or richer mix.
Extra for cutting reinforcement bars manually/by mechanical means in R.C.C work (payment shall be made on the cross sectional area of R.C.C as per direction of Engineer-in-charge
Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material in cement mortar
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50m (stacks of cleaned bricks shall be measured) in cement mortar
Providing & laying in position cement concrete of specified grade excluding the cost of centering & shuttering. All work upto plinth level. 1:4:8 (1 cement : 4 coarse s and 8 graded stone agg. 40 mm nomical size)
Providing & laying in position cement concerte of specificed grade including curing but excluding the cost of centering & shuttering all work upto plinth level 1:3:6 (1 cement: 3 coarse sand : 6 graded stone agg 20mm non size)
Providing & laying in position cement concrete of specified grade including curing but excluding the cost of shuttering.All work upto plinth level. 1:2:4 (1 cement :2 coarse sand : 4 greded stone agg 20mm size)
Brick work with common burnt clay (non-modular) of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:4 (1cement 4 coarse sand)
Providing & laying in position specified grade of reinforced cement, concrete including curing but excluding the cost of centering, shuttering, finishing & reinforcement. All work upto plinth level.1:2:4 (1 cement 2 coarse sand : 4 graded stone agg. 20 mm nom size)
Centering & shuttering including strutting, propping etc& removing of form
a) Foundation, footings, bases of columns etc and removal of form for mass concrete
b) Suspended floors, roofs, landings, balenus, and access plateforms
c) c) Columns, pillars, piers, abutments, posts & struts edges of slabs & breaks in floors and walls under 20cm wide.
Filling available excavated earth (excluding rock) in trenches plinth sides of foundation etc. layers not exceed 20 cm in depth, consolidating each deposited layer by ramming & watering, lead upto 50m & lift upto 1.5m
Providing & laying non pressure NP2 class (light duty) R.C.C pipes with coler jointed with stiff mixture of cement morter.
(a)100mm dia R.C.C pipe
(b) 150mm dia R.C.C. pipe
(c) 250 mm dia R.C.C. pipe
(d) 300 mm dia R.C.C pipe
Laying, spreading & completing stone aggregate of specified sizes to WBM specifications in uniform thickness and rolling with a requisite type of screening & watering comp
Providing & applying tack coat using hot straight run bitumen emulsion conforming to using emulsion pressure distributer including preparing the surface and clearing and preparing the existing road surface as per specifications.
On W.B.M @ 0.75kgs/sqm
On bitumen surface @ 0.50 kg/sqm
2cms premix carpet surfacing with 2.4cum of stone chipping 11.2 mm nom size per 100sqm bitumen emulsion (medium setting mix 650% bitumen contents) comply to IS 8887 using 96 kgs per cum of chipping of road surface including consolidation with road roller etc comp
Providing laying of seal of premixed fine agg (passing 2.36mm & retained on 180 micron serve) with bitumen per cum of fine aggg& 0.60 cum of fine agg. Per 100 sqm of road surface incl. rolling all comp
Removal of blokades from main sewer line/laterals of various dia varying from 150mm to 1400mm by manual/mechanical means including its disposal as per directions of engineer-in-charge
Providing & fixing of wall face unplasterisedriged PVC rain pipe 110mm dia conforming to IS13592 type . A including jointing with seal ring conforming to IS 5382 leving 10mm gap for thermally expension Making connection to the sewer line
a)Plumber/mason
b)Labour/sewerman
c)PVC coupler
d)PVC bend 45 degrees
e)PVC bend 90 degrees
f)Providing & Fixing PVC pipes of 110 mm pipe approved band
Providing & fixing in position precast R.C.C man hole cover of required shape & quality
a)Providing & fixing in positing rectangular shape 600x 450 mm
b)Square shape 450 mm internal dimensions ( LD-2.5)
c)Circular shape 450mm internal dimension (LD-2.5)
d)Circular shape 500mm internal diameter (MD-10)
e)Square shape 450 internal dimensions (Md-10)
Refixing of cement cone tiles in con 1.3 mix
Steel reinforcement for R.C.C work ready to use cut & use including cutting bending placing in position in all comp upto plinth level Thermomechanically treated bars of grade Fe-500D or more
Carriage of materials Sand &Bajree 7 km by MT
Stone agg 40mm &above 7Km by MT
Bricks av. 20 kms by MT & 150m HL
Clearing jungle including uprooting of rank vegetation, grass brush wood, trees and saplings of girth upto 30cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50m outside the periphery of the area clared.
Chequerred precst cement concrete tiles 22mm thick in foot path and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing, cleaning & curing complete on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Dark shade using ordinary cement
Providing wood work in frames of doors, windows, clear story window & other frames, wrought framed & fixed in position with hold fast lugs or with dash fasteners of reqd. dia& length Second class deodhar wood
P/F pandling or panelling& glazing in paneled or panelled& glazed shutters for doors & windows &clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebatess to be measured) panelling for panelled& glazed shutters 25mm to 40mm thick Second class deodhar wood
P/F glazed shutters for doors & windows & clerestory windows using 4mm thick float glass panes including 151 marked but hinges finish with necessary screws for 35mm thick 2nd class Deodar wood
P/F specified board medium density exterior grade I Flat pressed 3 layer particle board or graded wood particle board 15:3087 18mm
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade & incl. water thinable cement primor (on new work)
Distempering with dry distemper of approved brand & manufacture (one or more coats) and of reqd. shade on old work to give an even shade
Applying priming coat With ready mixed pink or grey primer of approved brand& manufacture on work (hard & soft wood)
Painting with synthetic enamel of approved brand & manufacture to give an even shade two or more coats coats on new more
Painting with synthetic enamel of approved brand & manufacture One or more coats on old work
P/L vitrified floor tiles in deff. Sizes thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS 15622 of approved make, in all colours& shades, laid on 20mm thic cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement & matching pigments etc complete. Size of tile 500 x 500 mm
Supplying & stacking of good earth at site royality (earth measured in stacks will be reduced by 20% for payment)
Spreading of sludge, dump manure or land good earth in reqd. thickness as per directions (cost of sludge, dump manurs and good earth to be paid separately)
Surface dressing of ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m & lift upto 1.5m in all kinds of soils
P/F aluminum work for doors windows, ventilators and partitions with extruded built up standard tabular section/appropriate Z section and other section of approved make conforming to IS: 733 and IS 1285, fixed with dash fastner and reqddia and size incl. necessary filling up graps at junctions i.e. at top, bottom and sides with reqd EPDM rubber/neoprene gasket felt etc. alumunium sections shouldbe smooth, rust free straight, mitered & jointed mechanically whever reqd incl. cliat angle, aluminium snap beading etc for glazing/penelled C.P brass/stainless steel screws all comp. as per Drg. & Directions of Engineer-in-charge (glazing, penelling& dash fasteners to be paid for separately) For fixed portion Anodized aluminium (anodized transparent or dyed to reqd. shade according to IS : 1868 min anodic coating of grade Ac 15)
For shutters of doors, windows ventilators incl providing & fixing hinges/pivots & making provisions for fixing of fitting wherever necessary incl. the cost of EPDM rubber/neoprene gasket (fitting to be paid separately) Anodized aluminium (anodized transparent or dyed to reqd. shade according to IS 1868 min anodic coating of grade Ac 15)
P/F 12mm thick prelaminated particle board flat pressed three layer on graded word board (conforming to ISI 2823 grade -I type -III in panelling fixed in aluminium doors windows shutters &pertition frames CP brass/stainless steel screws etc. comp. as per directions of engineer-in-charge Pre-laminated particle board with decorative lamination on.one side & balancing on other side.
P/F glazing in aluminium door, window ventilator shutter & partition etc with EPDM rubber comp as the direction of engg-in-charge (cost of aluminium snap beading to be paid separately) with floating Glass panes of 4.0 mm thickness (Ht. not less than 0.1/ sqm
P/F powder coated aluminium work (min thickness of powder coating 50 micron) consisting of tee/angle sections of app make conforming to IS 733 in framers of false ceiling incl. aluminium angle cheats with necessary S.P brass/stainless stul sunk screws, alumunium perimeter angles fixed to wall with steel less steel rawl plugs @ 450mm centre to centre& fixing the frame work to GI level adjusting hangers 6mm dia with necessary. Cadium plated machine screws all comp as per engineer-in charge (level adjusting hangers, ceiling chats and expansion hold fasteners to paid for separately)
Providing & fixing 6mm dia GI level adjusting hangers (upto 1200 mm length) fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and stainless steel expandable clash fasteners 12.5 mm dia 50mm long complete as per directions of Engg. In charge
P/F machine moulded aluminum covering of approved pattern & design, made out of machine cut aluminum sheet & machine hold for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one now on one side of join only shall be done with stainless steel dash fastner on 8mm dia and 75mm long bolt incl. providing aluminum washers 2mm thick, 15mm dia at a staggered pitch of 200mm C/C incl. drilling holes in the receiving surfaces & providing expandable plastic sleeves in holes etc complete as per directions of Engg-in-charge anodized aluminum sheet 2.5mm thick (Anodized trans or dyed to reqd. Shade according to IS : 1868 minanodic coating) of grade Ac-15
Filling the gap in between aluminum frame & adjacent RCC/brick/stone work by providing weather silicon over backer rod as per directions of Engg-in-charge Upto 5mm depth & 5mm width
Extra for applying additional anodic coating AC 25 instead of Ac 15 to aluminum extruded sections
a) for fixed portion
b) shuttering of doors, windows & ventilators
P and F anodized aluminum grill anodised transparent or dyed to reqd shade according to IS: 1868 min, anodic coating of grade AC 15 of approved Design/pattern with approved Standard section and fixed to the existing window frame with C.P brass/stainless steel screws @ 200 mm C/C incl. cutting the grill to proper opening size for fixing & operation of handles & fixing approved anodised standard section all comp (only weight to grill to be measured for payment)
Providing/Fixing aluminum tabular handle bar 32 mm outer dia 3.0mm thick & 2100 mm long with S S screw etc comp. as per directions of Engg-in-charge Aluminum (Ac-15) aluminum tabular handle bar
Providing/Fixing aluminum round shape handle order dia 100 mm with SS screws etc complete (Anodized (Ac-15) aluminum
Providing/Fixing paneling or panelling& glazing in paneled or paneled & glazed shutters for doors, windows & clerestory windows (area of opening of panel inserts excluding portion inside grooves ribatis to be measured) paneling for paneled or paneled glazed shutters 25mm to 40 mm thick 9mm thick commercial ply on b/s
Providing/Fixing fixing aluminum stiding doors bolts ISI market (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed
Providing/Fixing aluminum tower bolts ISI marked (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed
Providing/Fixing of ISI marked aluminum butt hinges (anodic coating not less than grade AC 10 as per IS -1868) transparent or dyed with necessary screws( complete Job)
Earth work in bulk excavation by manual means not exceeding 30 cms in depth but exceeding 1.5m in width as well as 10m2 on plan incl. disposal of excavated earth lead upto 50m & lift upto 1.5m as directed by Engineer All kinds of soils E/W in Exc (hydextcavate
Providing/Fixing tiles false ceiling of specified material of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms) sqm both side encl) consisting of main Trumer with suitably joints to get regd. Length end of size 24 x 38mm made from 0.30 mm thick sheet spaced at 1200mm long spaced between main-T at 600mm C/C to form a grid of 1200 x 600mm & secondary cross T of length 600mm & size 24 x 25mm made of 0.30 mm thick sheet to be interlocked at middle of the 1200 x 600 mm panel to form grids of 600 x 600mm & walls angle of size 24 x 24 x 0.30 mm & laying false ceiling tiles of app. Textura in the grid including renner wherever requd. Cutting renners to be suspended from ceiling using G.I. slotted cleats of size 27 x 37 x 25 x 1.6mm fixed to the ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm G.I adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced (The rate is excluding the cost tiles which will be paid separately) 12.5 mm thick fully perforated gypsum board tile made fromplaster board having glass fiber conforming to IS 2095 port-I of size 595 x 595 mm, having performation of 9.7 x 9.7 mm at 19.4mm c/c with centre boarders of 48mm & the side boarders of 30mm backed with non woven tissues on the back side, having an NRC (Noise reduction coefficient) of 0.79 with 50mm resin bonded glass wool backing
Silt clearance from drains inclusive of initial lead and lift (50m & 1.5m respectively)
Slip clearance In soils mixed with moorum/kankar/shingle/boulders, disposal lead upto 50m lift upto 1.5m
Tractor with trolley
Water tanker 5000 ltr. Capacity
Hydraulic excavator of 1 cum bucket
Hire charges of suction jetting machine 1500 PSI machine I/C Pol & operator
Hire charges of suction jetting machine 2200 PSI machine I/C POL & Operator
Finishing with deluxe multi surface paint system for interiors & exteriors using primer as per manufacturer, specifications painting steel work with delux multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90 lts /10 sqm over an under coat of primer @ 0.80/10 sqm of approved & manufacture.
Earth work in excavation by mechanical means (hyd excavation) in trenches for foundation, drains, pipes, cables etc (not exceeding 1.5m in width and not exceeding 10 sqm on plan incl. dressing & ramming bottoms lift up 1.5m incl. getting out excavated earth &disposal of surplus earth within a lead of 50m. all kinds of soils
Removal mulba from designated sites and disposal as per directions, all inclusive lead 50m. upto 5 km
Steel work welded in built up sections/framed work incl cutting, hoisting, fixing in position and applying a praming coat of approved steel primen using structural steel etc as regd. In gratings, frames, guard bar, ladder, raitings, brackets, gates & similar work
Providing/Fixing white viterous china pedestal type water closet (European type WC pan) with seat & lid, 10 meter low level white PVC flushing cistern including flush pipe, with manually controlled divice handle level conforming to IS:7231 with all fitting and fixtures comp. incl. cutting & making good the walls and floors, wherever regd. WC pan with ISI marked white solid seat& lid
Providing/Fixing wash basin with C.I brackets, 15mm C.P Brass pillar taps, 32mm CP brass waste of standard pattern incl. painting of fitting & brackets, cutting & making good the walls white vitreous china wash basin size 630 x 450mm with a pair of 15mm CP brass pillar taps.
P/F PVC waste pipe for sink or wash basin incl PVC waste fitting 32mm dia
P/F G.I pipes complete with GI fittings excluding trenching& refilling (external work)
15mm dia nominal bore(Medium)
20 mm dia nominal bore(Medium)
25mm dia nominal bore(Medium)
32mm dia nominal bore(Medium)
P/F brass stop cock of app quality
P/F of gate valve with C.I wheel of app quality
Making connections of GI distribution to GI main complete job 25 to 40mm nom bore
Providing/Fixing CP brass bib cock of 15mm nominal bore
Wiring for light point/fan point/exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/recessed medium class PVC Conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for light point/fan point/ exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in \\, Existing Surface/ recessed medium class PVC Conduit(cost of PVC ; Pipe not included), with modular switch, modular plate, suitable G.1. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required (In existng Laid Conduit).
Wiring for twin control light pointwith 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC Conduit , with 2 way modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for Light / Power Plug with 2 x 4 sq.mm FRLS PVC Insulated 2 Copper Conductor single core cable in surface / recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 x 1.5 Sq. mm + 1 x 1.5 Sq. mm earth wire
b) 2 x 2.5 Sq. mm + 1 x 2.5 Sq. mm earth wire
c) 2x6 sqmm + 1x6 sqmm earth wire
d) 2x16 sqmm + 1x6 sqmm earth wire
e)4x4 sqmm + 2x4 sqmm earth wire
f) 4x6 sqmm + 2x6 sqmm earth wire
g ) 4x10 sqmm+ 2x6 sqmm earth wire
h) 4x16 sqmm+ 2x6 sqmm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding; modular plate etc. as required.
a)5/6 amps switch
b) 3 pin 5/6 amp socket outlet
c )15 A/16A switch
d)15 A/16A Socket
e)32 A Switch
f)32 A Socket
g)Telephone Socket Outlet
Supplying and fixing modular blanking plate on the existing modular plate (Sr switch box excluding modular plate as required.
Supply and fixing following size/modules, GI box alongwithmodular base & cover plate for modular switches in recess etc as required.
a. 2 Module
b. 3 Module
c.4 Module
d. 6 Module
e. 8 Module
f. 12 Module
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 Si 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and Fixing of Following sizes of PVC Conduit along with Accessories in surface/Recess including painting in case of surface conduitcutting the wall and making good the same in case of recessed conduit as required.
a. 25mm PVC Conduit
b .40 mm PVC Conduit
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and connissioning etc. as required. Single Pole
Supplying installation testing 'commissioning of Ceiling Fan, Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1,5 sq.mm FR PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as required. (As per list of approved make).
a) 1200 mm SWEEP
b) 1400 mm SWEEP
Supplying installation testing commissioning of pre-wired Surface Mounted 15 watt LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required (Make: Philips Model No: SM200C LED 16S 6500 PSU OD WH or equivalent)
Supplying installation testing commissioning of pre-wired Surface Mounted 12 watt LED Ceiling Light including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.
Supplying installation testing commissioning of pre-wired 18/20 watt Surface Mounted LED Batten Fitting)
Supply and fixing 2'x2' recess 36 watt LED panel
Supply and fixing 2' Led batten mirror light
VIPAN KUMAR
Som Kumar
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .