Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 CrAccepted-AOC | ₹9.5 Cr | L1 | Accepted-AOC PROPER |
| 2 | L2₹9.7 Cr+₹20.8 L (2.19%)Rejected-AOC | ₹9.7 Cr+₹20.8 L (2.19%) | L2 | Rejected-AOC Not Qualified for AOC |
Tender Value
₹9.7 Cr
EMD Value
₹19.4 L
Closing Date
12 Oct 2020, 2:00 pmClosed
Chief Engineer,W.R.Deptt
O/O Chief Engineer Water Resources Department Chandmari
Rejuvenation of Kolong River- Construction of Intake and Appurtenant Structures (Ph-I).
2020_DoWR_18752_1
NAGAON/2019-20/SOPD-ODS/IV
Open Tender
Civil Works
Works
90 days
NAGAON
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
The Executive Engineer, Nagaon W R Division
₹19.4 L
Yes
14 Dec 2020
21 Sept 2020
13 Oct 2020
21 Sept 2020
12 Oct 2020
30 Sept 2020
Amount
Head Regulator at Intake Point Earthwork in excavation by Hydraulic Excavator, to proper grade and slopes as required including utilizing the spoils for filling works in the vicinity including removing roots & vegetation, dressing to design section complete as directed. Ordinary Soil, For depth up to 3.00m
Earth work in filling by mechanical means including ramming means by deploying hydraulic excavator and trippers etc. with locally available ordinary soil excluding rocky soil with all lead and lift, transporting to site, spreading, dressing as per design section including ploughing or roughening obenching the seats, removing all debris, breaking clods up to 2.5cm cube, payment of forest royalty if any, etc. complete as directed. (10% deduction will be made from the section measured quantities of the completed and compacted earth work on account of shrinkage)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering of M15 Cement Concrete-
Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge
Centering and shuttering including strutting, propping etc. and removal of form for Columns/Piers/Abutments
Centering and shuttering including strutting, propping etc. and removal of form for Foundations
Centering and shuttering including strutting, propping etc. and removal of form for Profile/Retaining Walls/Slavs
Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Supplying and stacking of hard stone (for stone pitching) at site-
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying & Installation of Sheet Piles as Cut Off Wall all complete as per the approved design/drawings.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement Mortae (1:4)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
CARRIAGE OF MATERIALS Coarse Sand (30Km lead)
CARRIAGE OF MATERIALS Stone chips+Metal (60Km lead)
CARRIAGE OF MATERIALS Cement (30Km lead)
CARRIAGE OF MATERIALS Steel (30 km lead)
CARRIAGE OF MATERIALS Boulders(60KM)
Construction of Coffer Dam at Offtake Item : Earth work in filling by mechanical means including ramming means by deploying hydraulic excavator and trippers etc. with locally available ordinary soil excluding rocky soil with all lead and lifttransporting to site, spreading, dressing as per design section including ploughing or roughening obenching the seats, removing all debris, breaking clods up to 2.5cm cube, payment of forest royalty if any, etccomplete as directed. (10% deduction will be made from the section measured quantities of the completed and compacted earth work on account of shrinkage)
Item : Compacting original ground (i) Compacting original ground supporting embankment Loosening, leveling and compaction original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300.1 and 300.2 for embankment construction as per technical Specification Clause 301.4.1
Construction of Raised Plarform and ancilary works Earth work in embankment by truck carriage in ordinary/normal soil excluding sandy and rocky soil free from roots & vegetation and filling in uniform layers not exceeding 22cm. thick including ploughing or roughening or benching the seats, removing all debries, breaking clods up to 2.5cm cube, dressing as per design section including payment of forest royalty if any, etc. complete as directed. (10% deduction will be made from the section measured quantities of the completed and compacted on account of shrinkage)
Item : Compacting original ground (i) Compacting original ground supporting embankment Loosening, leveling and compaction original ground supporting embankment to facilitate placement of each layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling sa as to achieve minimum dry density as given in Table 300-2 for embankment construction.
Supply of Solar street light with IP 65 LED fixture having a system wattage of 21W of Philips BRP 402 make) with 1864 lumen system output, 100Wp high efficiency crystalline solar panel certified IEC 61215 and 100Ah tubular lead-acid battery with BIS approval. Total Nos. of LED is 16 with individual Peanut Lens and each LED lumen efficacy shall be at least 130 lumens/watt and the LED driver should have > 90% efficiency. The battery shall not be discharged beyond 75% of capacity. The solar charge controller is of Microprocessor Based MPPT make) with 94% efficiency and enclosed in IP 65 box. The charge controller shall provide all safety protections and temperature compensated charging of the batter. The battery shall be housed in a box made from galvanized steel and powder coated so that it withstands corrosion. The solar system should be mounted on a 6.0 Metres MS Galvanized Tubular Pole. The solar street light shall comply with standards such as IEC 61215, IEC 62124, IEC 61347-2-13, IEC 62384, CISPR 15, IEC 61547, and IEC 60598.
Installation & Commissioning Charges for street light including cc foundation as directed by the Deptt.
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following. a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts.. b). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed. c).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (b) In hard/ dense soil- For Building
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Quality Control Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) A. Cement (i) Compressive strength. (Item 28.2-As per SOR of APWD 2013-14 including GST correction)
Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) B. Concrete (i) Compressive strength(including moulding & curing)
Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) B. Concrete (iii) (a) Mix design
Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) C. Steel (i) Tensile strength of steel.
Collection of sample from field and testing in laboratory/field as per relevant I.S. codes of practice and preparation and submission of of the reports to the concerned authority in proper format with specified no. of copies (minimum 5 copies) C. Steel (ii) Bending & Re-bending of steel.
Mechanical Works Fabrication of Shutter (Six Nos) SKIN PLATE: M.S. Plate 8mm(conforming to IS Specification) fornew fabrication of shutter skin plate.
SHUTTER FRAME : M.S Channel Size : 175 mm x75mmx 6 mm for new fabrication of shutter frame
HORIZONTAL GIRDER & VERTICAL STIFFENERS FOR SHUTTER : M.S Channel Size : 150mm x75mmx 6 mm for new fabrication Horizontal Girder &Vertical Stiffeners
M.S. Channel (175x75) mm for shutter over top
M.S Angle 75x75x8 mm
M.S. Flat (50x6)mm for fixing rubber seal
Resilient rubber seal “J” type ,125 mm (best quality)
“J” type Corner /Seal retainer strip ,125 mm
Nuts & Bolts
M.S. Plate 10 mm for brackets
M.S Electrode 8 SWG
Red oxide primer
Antisol red oxide paint
Turpentine oil
Steel wire brush
Painting brush 3”
Refilled Oxygen gas
Refilled Acetylene gas
M.S guide roller to accommodate rotation of the iron shutter having specific suitable collar 10-12 mm & centre hole 10-20 mm, effective length 100-120 mm
M.S guide roller bracket made of 10 mm thickness of size 75 x200 mm with hole as per direction to accommodate above roller , Size : 100 x150 mm
H.S. Diesel for30 HP ArcWelding Generating set.
Fabrication& Installation of Guide (Double Channel)and Bottom Channel for shutter M.S. Channel 200 x 75 mm for double acting Guide Channel.
M.S. Channel 250 x 80 mm for Bottom Channels etc.
M.S. Plate 10 mm for fitting of Guide Pairs of Channel
M.S Angle (75x75 x 8)mm for anchoring.
Guide channel separator stud with nut on both end with tube of length 250mm to 460mm, for double acting Guide Channel.
M.S. Electrode ,8SWG
GI Pipe 25 mm dia
Refilled oxygen Gas
Refilled Acetylene Gas
Red oxide primer
Red oxide paint
Turpentine oil
Steel wire Brush
Painting Brush 3”
Nuts & Bolts different size
M.S. Washer (Assorted size )
H.S. Diesel for 30 BHP Diesel Arc Welding Generator
Installtion & fabrication of mechanical & electrical appliacnces above the platform for power operation & lifting of sluice gate (Electrical Appliances to be mounted for power operation) Supply & installation of 2 HP 3 Phase Induction Motor with all parts & accessories complete as directed.
Supply & installation of Gear Box Unit with reduction gear arrangement
Crank Shaft Assembly unit to mount on Gear Box
Hand Wheel
End thrust Shaft Bearing75 mm
Horizontal M.S Shaft 75 mm dia .
Rope Drum wheel assembly
Steel Rope 16mm
U Clamp ,19 mm
Clamps assembly and Nuts for each motors and shafts
Shaft ball bearing made NBC No. 6208 ,75mm dia
Shaft Oil seal
Rising shaft assembly of shaft motor with clamps &fixtures
T head steel Fasteners( L 200 -300mm , 0.2-0.5 mm Tolerance
Yoke Assembly
Carbon Steel Operating Nut (EN -8 )
Shaft end Lock Pin
Flush Bottom Seal (NBR )
Spacing collar of worm shaft made of mild steel outer dia 75 mm , inner dia 40 mm , length 24 mm
Rope drum shaft tapered bearing no. K1813 , outer dia 120 mm , inner 15 mm
Shaft key made of HD Steel
Spur gear main shaft bearing outer dia 110 mm & inner dia 60 mm
Spur gear shaft made of MS outer dia 90 mm x inner dia 60 mmx44 mm size of raised portion 5 mm, thickness 40 mm x 10 mm
Helical teeth spur gear made of Cast Iron and bronze with inner lock grove
Line shaft pinion made of cast iron material. OS size
Intermediate pinion made of CI outer size
Shaft socket bushing made of MS
Worm shaft ball bearing made NBC No. 6208 , Size of dia: 75mm
Worm shaft Oil seal
Stuffing box bearing no. 1213 EKTN(4 nos. per gear system )
Stuffing box bearing no. 120 BK ( 2 nos. per gear system )
Roller Bearing for Gear Box. Type : HSN 180
Gear Box Driven shaft with pinion. Type : HSN 180( Input )
Gear Box Driven Shaft with Pinion. Type : HSN 180(Output )
Gear Box Oil seal
Gear Box Lock Pin
Gear Oil
W.B Grease
Supply and installation components of Distribution Panel(consisting of 4 Nos. of MCCB , Voltmeter0-500 Volt , Ammeter 0-100 Amps,3 - Fuses , 4 nos Lever Type Operating handle etc. & all other parts as per requirement & direction )
Distribution Panel Box
Starter Panel
Starter Panel Box
Supply and installation LT Aluminium armoured cable ( 1 core 50 sq mm)
Fuse (for starter panel low current)
Forward Reverse Starter Switch
Voltmeter 0-500V
Ammeter 0-100A
Indicating Light (Red, Yellow, Green)
Fuse (for distribution panel high current)
Voltmeter Switch
Ammeter Switch
High Current Handle Type Switch
Relays
Circuit Breaker
Fabrication & installation of Platform with ladder for Sluice Gates M.S. chequered Plate 6mm for platform, ladder.
M.S angle ( 75x75x8) mm for vertical railing post , platform support etc.
M.S angle ( 50x50x6 ) mm for Horizontal railing rows
M.S. Electrode 8 SWG
M.S. Electrode 10 SWG
M.S channel 175 x 75 mm for Over Top , base support
M.S channel 150x 75 mm for platform Horizontal cross bar &Vertical lift
Refilled oxygen Gas
Refilled Acetylene Gas
Red oxide primer
Red oxide paint
Turpentine oil
Iron Nuts & Bolts
M.S. Washer (Assorted size )
H.S. Diesel for Arc Welding Generator Set
Miscellaneous items and welders /ordinary labours Supply of ordinary labours for various helping works, lifting and carrying sluice gate materials including assigned works of welding & fabrication, other allied works at site etc.
Arc Welding holder , 400/ 600 Amps
Arc Welding cable 600 amps
Jati Bamboo 60mm to 75mmdia and 5m to 6m long
Coir Rope
Mobil for Arc Welding Generator &machineries.
Waste cotton
M.S Rod 16mm
Gas Cutting Hose pipe,12 mm dia (Red& Black)
Leather Hand Gloves
Arc Welding Mask
Gas cutting nozzle
Hacksaw blade 1.5’’x12’’(Double ended)
Nylon rope
Hire charge of crane with Capacity of 8 ton with operator excluding fuel & lubricant
Supply & installation of generating set and control panel Provision of captive power for operation of Sluice : Supply & installation of 30KVA 3 Ph DG Set (Kirloskar 1 Green Make 3R1040/ at 1500 RPM three cylinder , Water cooled Diesel Oil Engine with 25 KVA, 3 ph 415 Volts50Hz,1500 RPM,0.8 power –factor Alternator along with suitable Amco make 12 V, Battery & leads, Standard Control Panel board, Fuel Tank self start sound- proof complete Silent DG set for captive power in the utility services of Sluice Gate Operation including earthing, panel board , change over arrangements etc. complete as directed )
11 KV XPLE 1 core 50 sq mm Aluminium Armoured cable
Indicating Light (Red, Yellow, Green)
Fuse on Control Panel Board(for distribution panel high current 11 KV/800Amp, Resettable type , Polymeric & Porcelain , 3 pole )
Push Button Switch
MCCB 100 A ( ICS =100% ICU )
High Current Handle Type Switch for Distribution Panel
Universal Motor Control and Drivers(with micro controller)
Circuit Breaker
Thermal overload relay with accessories
Digital Electronic Motor Protection Relays 3 phase/50 Hz, 415 Volt for starter panel board.
Timers
Power Supply Board
Voltage Control Transformers
Reactors and Filters
Supply & installation of Control Panel Unit consisting of Relay, Circuit Breaker, Fuse , MCB , Voltmeter , Ammeter etc.
DOL automatic reversing starter 25 amps complete with push bottom and indicating panel of reputed company L&T /Siemens column
Chequered rubber insulation sheet 12 mm thick
100mm x 10mm thick Aluminium bus bar in assorted size
Electric Sensors
Reputed Make DOL starter suitable for 3/2 HP motor with three phase relay
Reputed make main switch 800 Amps / 415 volts, 3 Pole BS Fuse type (SFU) of HRC Fuse linking for main Panel Board of 3/2 HP motor
Sub switch for individual motor (415 volts /600 Amps)
Auxiliary Contact Block
Reputed make 3 sq mm single core insulated copper wire
Auxiliary Contact & Alarm Contact
Over voltage Release
CT, 800/5A, 10VA, Class-1
CT, 500/5A, 10VA, Class-1
CT Operated Ammeter, 0-800A, CTR-5A
6A Transmission Pole MCB
6A Supply Pole MCB
Neutral Link
630A, Transmission Pole , Isolator
16A, DP MCB, 110V for motor space heater
32A, TP Switch fuse unit
Avonite Board a] 6mm thick 10’x5’
Avonite Board b] 12mm thick 6’x8’
Complete internal electrification including supply of exhaust fans, ceiling fans, stand fans, tube light assembly wires, cables etc & also Gen-set to Main control Panel Board complete etc as per direction.
Installation of transformer (APDCL) Supply of 25 /11 KVA Transformer ( Aluminium Wound , 50 C/S DELTA STAR connections ,High –Low voltage Bushing ,No load Voltage ratio 11/0.433 KV, 3 phase, ONAN Cooling Type, Silica Gel Breather ratio including installation charges.
GI Channel (150 x75 x6) mm
GI Steel Tubular Pole SP-66
Supply & Installation of Clamps, Hooks, Shackle insulators ,Rods, Nut and Bolts, Washer, P V C Pipes, Conduit Fitting etc complete as directed
Supply and installation of 11 KV ,70 sqmm 3 core Aluminium HT Electrical cabling from i) Control Panel Board to Distribution Panel Board (above platform) ii) Distribution Panel Board to Individual Motor Starter Panel Board
For 800 Amp Air Circuit Breaker i) Reputed Make over load / short circuit protection relay
For 800 Amp Air Circuit Breaker ii) Under voltage relay
For 800 Amp Air Circuit Breaker iii) Earth fault relay
LT metering cubical for 25/11 KVA Transformer including fitting & fixing of aluminium bus bar as per general APDCL specification.
Earthling Wire 4mm
Lightning Arresters (Spike made of copper forlighting protection )
MCCB Switch Assembly 200 Amps (ICS=100 % ICU)
Digital meter, 3 Phase, KWH & PF, 110V AC
325A, 3P, 110V AC, Delta and Line contactors assembly
265A, 3P, 110V AC, Star contactors assembly
Polymeric Disc Insulators
Bimetallic lug for transformer connections (insulated water proof (set contains 5 nos. lug as per cable )
Guy Wire 0.62 inches, steel stranded
Cut outs
Fuse and Connectors
Cross arm assembly material steel
600A, TP, 50KA, MCCB Microprocessor type with adjustable Overload, Short circuit and Earth Fault Release
11 KV Gang Operated (GOAB) Switch, 150 AMP for 11 KV Sub-Station
11 KV DO Fuse, 150 AMP for 11 KV Sub-Station
11 KV XPLE Cable 3 core 120 sqmm from transformer to control panel & generation set
11KV combined CT / PT
Transformer oil
Installation of solar lighting provision Solar panel Board of 150 W(Poly crystalline )
Solar charge Controller (MPPT)
Solar Battery(150 Ah, Luminous make)
Solar Flood Light 100W
Mounting of Panel Boards and fitting of lights etc. complete as directed.
Misc. items like wire, clamps, tapes etc.
Generator cum Panel Board Operator House Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering, complete. a).Brick on flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). PROP 1:3:6
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm downgraded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) In sub-structure Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. b) M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm downgraded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (b) In super-structure ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, Bessemer , cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing b) M20 grade concrete or Prop. 1:1.5:3
Brick work in cement mortar with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure up to plinth level including dewatering if necessary a) In prop 1:4
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed (II) In superstructure above plinth level up to 1st floor level (b) In proportion 1:4.(1 cement:4 sand)
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). (b) 0.50 mm thick
Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed (i) 150 mm lapping
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering and propping etc height of propping and centering below supporting floor to ceiling and removal of the same for in situ reinforced concrete and plain cement concrete. 38mm thick plank In sub structure i) Sides of tie beam
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering and propping etc height of propping and centering below supporting floor to ceiling and removal of the same for in situ reinforced concrete and plain cement concrete. 38mm thick plank In sub structure ii) Column
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering and propping etc height of propping and centering below supporting floor to ceiling and removal of the same for in situ reinforced concrete and plain cement concrete. 38mm thick plank In sub structure iii) Flat surfaces such as roof, landing, balcony
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering and propping etc height of propping and centering below supporting floor to ceiling and removal of the same for in situ reinforced concrete and plain cement concrete. 38mm thick plank In sub structure Sides of tie beams, grade beams etc. at or below ground level.
Providing wood work in frame of door window clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry walls including supplying, fitting and fixing with M.S flat hold fast (40mm x 30mm x 25mm) as per design and embedded in cement concrete block in prop 1:1:4 and two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing fully paneled doors including oxidized M.S butt hings (100mm x 75mm x 3.55mm ) with necessary screws ( other fittings shall be measured and paid separately) a) With 1st class local wood (Gamari, sundi, Hollock, Bonsum) of 40mm thick
Providing fitting and fixing fully glazed windows without intermediate sash bars including oxidized M.S butt hings(75mm x 60mm x 3.15mm) 2Nos on each leaf glass panes to be measured and paid separately) a) With 1st class local wood (Gamari, sundi, Bonsum, Hollock) of 40mm thick
Providing fitting and fixing fully glazed CLERESTORY window and fan light including fitting and fixing 2 Nos of M.S pivot hinges (75mm x 20mm x 3mm ) eye hook and nylon chord complete (glass panes shall be measured and paid separately) a) With 1st class local wood (Gamari, Sundi, Bonsum, Hollock) of 40mm thick
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I S code for RCC work/R B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc complete(upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.)
20mm thick cement plaster in two coats, backing coat 15mm and finishing coat 5mm thick on rough side of single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed a) In cement prop 1:3
20mm thick cement plaster in two coats, backing coat 10mm and finishing coat 10mm thick on fair side of brick/stone masonry walls for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm in girth and finished even and smooth including curing complete as directed a) In cement prop 1:3
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. b) 50mm thick
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor (b) 20 mm thick
Providing fitting and fixing M S Grills of required patterns for indows/ ventilators/ openings with M S flat at required spacing and frame all round, square or round M S bars with round headed bolts and nuts or screws a) Plain Grill fixed to wooden frame
Providing and fixing clear sheet glass bedded in putty and fixed with/without wooden beadings including necessary cutting of glass to required sizes (Payment for wooden beads shall be made separately) a) Area of glass panes exceeding 0.15 sqm but not exceeding 0.52 sqm (4mm thick)
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) a) Sliding door bolts (300 x16) mm
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) b) Door & Window handle (100mm)
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) d) Tower bolt ( 300mm x 12mm)
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) b) Tower bolt150 x10mm
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) c) Butt hinge for door
Supplying,fitting, fixing anodized Aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary Aluminium screws etc. complete .( anodized to bright natural matt & satin finished ) d) Butt hinge for window
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirting, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) ii) Of size 600mmx600mm and above
Providing two coats of Birla white Wall care putty(water resistant white cement based putty for concrete/mortar walls and ceiling both internal and external) after removing of all loosely adhering materials from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity clean water as specified and directed by the department ( total thickness of two coats is maximum 1.5mm)
Applying one coat of distemper primer of approved brand and manufacture on wall surface after thoroughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth
Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after thoroughly brushing the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth.
Applying priming coat over new wood and wood based surface over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting a) With ready mixed paint, wood primer ( White)
Applying priming coat over new wood and wood based surface over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting a) With ready mixed paint, wood primer ( White)
Painting two coats (excluding priming coat ) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint / J N paint / Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter, sand papering and stopping. High gloss (Asian paint/ Berger paint/ ICI paint/ J N paint / Nerolac)
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm ii) Hindware make
Supplying, fitting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) i) Parryware make b) Coloured (ii) Deluxe Single Flush (Cat. No. C8091/C8057)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (B) Hindware Make (b) Coloured (i) CEDER 570 x 440 (Cat. No.91049/91115)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified a) In exposed surfaces or in trenches (ii) 110mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc .as necessary complete at all levels including below G.L as directed and specified a) In exposed surfaces or in trenches (ii) 110mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc .as necessary complete at all levels including below G.L as directed and specified a) In exposed surfaces or in trenches (iv) 75 mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches (iv) 75 mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified a) In exposed surfaces or in trenches (iv) 110 mm x 75mm
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (iv) 75mm dia. PVC cowel of ISI make
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table
Supplying and placing plastic cylindrical vertical closed top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. 1000 litre capacity (a) Sintex make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concealed by chiseling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. a) 50 mm dia (Medium)
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concealed by chiseling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. c) 32 mm dia (Medium)
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc. complete at all levels including below G.L. as directed and specified. (B) Concealed by chiseling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. f) 15 mm dia (Medium)
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Essco make (Delux /Sumthingspl. /Tropical) a) Bib cock short body
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (a) Continental / Clarion (i)15mm dia Male / Female (long thread)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed SONA make (a) Light type
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed d) 2O mm dia.
Supplying fitting and fixing gun metal check valve including necessary threads to pipes b) 40 mm dia (Heavy type)
DEEPAK KUMAR SINHA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .