Tender Value
₹2 L
EMD Value
₹40,000
Closing Date
22 Feb 2021, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF WATER SUPPLY INSTALLATION AT GOTHIC LINE, AJAYMERU, COMMAND OFFR MESS, HOLIDAY HOME AND MES IB UNDER AGE EM-II OF GE (S) JAIPUR
2021_MES_416135_1
GE (S)J-69P/2020-21 8632/ /E8
Open Tender
Civil Works
Item Rate
180 days
JAIPUR
Class E Cat b (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹40,000
Yes
26 Feb 2021
26 Jan 2021
24 Feb 2021
26 Jan 2021
22 Feb 2021
8 Feb 2021
Amount
Earthing complete with glavanised steel earth plate elactrode 600x600x6.0 mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to galvanised earth lead strip 25 x 4mm size by means of nut , bolt, check nut and washer of galvanised iron or of steel, earth lead protected by 40 mm dia GI pipe light grade watering pipe 20 mm dia GI light grade GI wire meshed funnel alternate layer of charcoal and salt PCC chamber , recessed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Pt-I 2009 print, complete all as specified & directed (Pannel Earthing)
S&F in repair of car fan 200mm complete for lift cabin of make approvel by manufacturear by KONE
S&F in repair of SMF Battery,12v 12 AH complete make approvel by manufacturear by KONE
S&F in repair of LCD display FSO545SA220-02 complete make approvel by manufacturear by KONE
Rewinding to self starter 12 volts make LUCAS by taking out old burnt out copper winding wire and rewinding with and including supper enameled copper wire of same gauge and commissiong and testing complete all as specified and directed
Replacement of pinion
Replacement of bush
Replacement of solenoid coil
Replacement of carbon brushes
Replacement of tension spring
Replacement of unseviceable lead acid battery 12 V120 AH. Make : Exide XP/Amaron
Replacement of unseviceable lead acid battery 12 V180 AH. Make : Exide XP/Amaron
S&F in replacement of gate hinges 30 to 160 KVA DG Set
S& F in replacement of lockes of DG set Gate as per existing
S& F in replacement of PCB card of AMF panel along with wiring as per existing
Replacement of existing old Unsv Self of 50 to 160 KVA DG Set
M&L for repair to rolling shutters of instalation room including replacement of mechanical rollers, spring, GI rod-3m long/as per existing ,locking handel,gear box and necessary greasing including preparing surface and applying one coat of synthetic enamel paint of superior quality over a coat of red oxide complete all as specified and directed..
Preparing the exposed surface of DG Set of any type/size and applying one coat of anti corrosion paint with spray painting (Colour as per E-in-C code to be followed),pipe line and equipment complete writing SM No. and MES No. with given size of letters/Figures all as directed by Engr-in-Charge.
Opening of DG set 10/15 KVA capacity Air/water cooled by unscrewing nuts, bolts and servicing of DG set, complete servicing, checking of oil, coolant, v-belts, greasing and oiling of parts and toping up , cleaning the inner body, tank and radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set and testing complete including comprehensive maintanance of DG sets as per B check with providing qualified staff at the site which will be adequate to perform routine maint and observed and understand the fault, Rectified the fault if they fail to solve the faults, contractor shall immediatly provide extra specialised work force so as to attend to the fault in minimise reasonable time with out any extra cost
All as per item No 17 above but DG Set of 20 to 30 KVA capacity Loc: Zone I =04, Zone -II =03 & Zone III =01
All as per item No 17 above but DG Set of 50 to 125 KVA capacity Loc Zone 1=01,Zone II=4 & Zone -III=3
All as per item No 17 above but DG Set of 160/250KVA capacity Loc Zone 1=01,Zone II-04
Replacement of following spare Parts for item No -17to20 above
Fuel gauge
Fuel pipe for injector
Emergency stop switch
Oil pressure meter
Display/generator controller unit of Kirloskar/Sudhir/CG DG set
Flexible coupling
Fuel tank Cap- as per existing
Coolent
Push Button for on /OFF
Transperant pipe for fuel tank approx 1 mtr
Engine oil
Fuel filter
Oil filter
Air filter
Repair to primarily fuel pump assembly suitable for DG set 50 KVA to 160 KVA all as DG company recommended.
Replacement of U/S Fuel section & injector return hose pipe with clamp for following capacity of DG sets as per existing size (set of 2).
15 KVA to 63 KVA DG sets
100 KVA to 250 KVA DG sets
Material and labour for fabrication of retro-reflectroised sign board of size exceeding 0.90 Sqm as per IRC : 67 made of encapsulated lens type reflective sheeting, fixed over aluminium sheet 1.5 mm thick of required size duly written with the matter as directed in blue colour mounted on angle iron/MS pipe support complete and including grouting the sign board in PCC 1:2:4 type B-2 using 40 mm graded stone aggregate grouted including necessay excavation and earth work complete all as directed by Engineer - in -Charge. Note – (i) Angle Iron frame work, PCC work shall be measured and paid for separately under appropriate item of Schedule 'A' (ii) Retro reflective sheet and letters shall be ASTM 4956 type 3 of high intensity grade of make:- 3M Grade 3870/Kiwalite 22000/Avery Dennison Series 6200
Material and labour for frame work of sign boards made of M S Angle iron or MS square or round pipe of suitable thickness and size as directed duly painted with two coats of synthetic enameled paint on all exposed surfaces over a coat of red oxide primer complete all as directed and specified by Engineer - in - Charge. Note:- The surface of angle iron coming in contact with PCC/Brick work shall be painted with two coats of bitumenous paint over a coat of red oxide primer and unit rate quoted for above item shall be deemed to include this aspect.
Excavation in trenches n.exc 1.5m width and n.exc 1.5m in depth and getting out in soft/ loose soil
M&L PCC 1:4:8 typeD2 (40 mm graded agg) as in foundation.
M&L for brick work with sub-class 'B' bricks, straight or curved on plan exc 6m mean radius built in In cement mortar 1:6
M&L PCC 1:3:6 type C1 (using 20mm graded agg) as in coping incl nessacery form work.
Returning, filling including spreading levelling, watering and well ramming in layers n exc 25 cm thick
Removing excavated material exc. 50m and deposited where directed at a level n.exc 1.5m above the starting point.
M&L rendering 15mm thick in CM 1:4 on fair faces of concrete surfaces and finishing the surface even and smooth without using extra cement.
M&L PCC 1:2:4 type B0 (using 12.5mm graded agg) in drain bed etc.
M&L preparation of new plastered surfaces and applying two coats of cement base paint on walls.
M&L Hume pipe 450mm dia class NP-2, reinforced.
M&L precast cement concrete 1:2:4 type B1 (20 mm graded agg ) in cover slabs for manhole etc, and set in CM 1:6
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement incl forms, moulds, mitred/stopped end etc.
Add or deduct for each 25mm girth or part there of over or under 30cm.
M&L mild steel TMT bars 10mm dia and cut to length bent to shape requiredd incl cranking bending, spirallu for hooping for column hooking ends & bending with and incl MS wire (annealed) not less than 0.9mm dia.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil
M & L hard core with broken stone or boulders of gauge not exc 63 mm deposited spread and levelled in layers not exc 15 cm thick and well rammed to a true surfaces
M&L PCC 100mm thick type D-2, 1:4:8 using 40mm graded stone aggregate in sub base floor etc
M & L machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 grade, with grey cement laid over and including 25 mm thick sand cushion and joints of interlocking tiles filled with dry sand and compacted with mechanical plate vibrator over 75mm thick PCC (1:4: 8) using 40mm graded stone aggregate complete all as specified and directed
M&L precast cement concrete blocks (Kerb stone )or slabs 150mm thick (1:2:4) mix type B-1 using 20mm graded aggregate with plain or interlocking joints as directed complete in walls setting in CM (1:4)
M & L for preparation of old decorated surfaces of walls, pillars and cornices including brooming down and cleaning the surface and applying one coat of white wash all as specified and directed
M & L for preparation of old decorated surface of walls and applying one coat of distemper oil emulsion of any tint all as directed.
M & L for preparation of old surface of walls and applying one coat of cement base paint of any tint all as directed.
M & L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed.
M & L for preparation of old painted steel surfaces of any description over 10cm in width or girth and applying one coat of synthetic enamel paint of any tint all as specified and directed.
Demolition of cement concrete in ground floor and paving not exc. 15cm thickness (below or above ground level)
Supply, Laying, Jointing, testing & Commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 35 Sqmm 3 ½ core complete all as specified and directed, including taking down old unserviceable cable.
Supply, Laying, Jointing, testing & Commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 120 Sqmm 3 ½ core complete all as specified and directed, including taking down old unserviceable cable.
S.R.Enterprises
DIVYA ASSOCIATES
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .