| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAdmitted-Finance | ₹8.4 L | L1 | Admitted-Finance |
| 2 | L2₹11.7 LAdmitted-Finance | ₹11.7 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sunrise Solar Pvt Ltd L2 | Vyoma Industries L1 |
|---|---|---|---|---|---|
| 1.00510 Ltr / Hour, Air source heat pump, with heating capacity of 22 kW, Heat exchanger BPHE /MCHE, Microprocess controlled , Time and temperature settable unit. Type of compressor type :Scroll. Maximum output temperature : 60 Deg. Heat exchangher - Aluminium tube , copper pipe. Type of refrigerant : R407 C . Input power : 6 kW Ouput power - 22 kW Power input - 415 V, 3 P phase. The units should be made of Powder coated CRCA sheet -16SWG . Necessary MS painted stand should be provided along with the unit. The unit must have provision to drain out water . All necessary piping interconnections to Solar water heater tank in and out are in the scope of work. Circulaiton pump of suitble capacity is included in the scope of work. | |||||
| 1.01 | Supply of above Equipment | 2 | Nos | 2,47,652 ₹5.0 L | 1,85,000 ₹3.7 L |
| 1.02 | Erection, testing and commissioning of above Equipment | 2 | Nos | 7,500 ₹15,000 | 5,000 ₹10,000 |
| 2.00350 Ltr / Hour , Air source heat pump, with heating capacity of 16 kW , Heat exchanger BPHE /MCHE , Microprocess controlled , Time and temperature settable unit. Type of compressor type :Scroll. Maximum output temperature : 60 Deg. Heat exchangher - Aluminium tube , copper pipe. Type of refrigerant : R407 C . Input power -4.4 kW Ouput power - 16 kW Power input - 415 V, 3 P phase. The units should be made of Powder coated CRCA- 16 SWG sheet . Necessary MS painted stand should be provided along with the unit. The unit must have provision to drain out water . All necessary piping interconnections to Solar water heater tank in and out are in the scope of work.Circulaiton pump of suitble capacity is included in the scope of work. | |||||
| 2.01 | Supply of above eqipment | 2 | Nos | 1,74,640 ₹3.5 L | 1,15,000 ₹2.3 L |
| 2.02 | Installation charges | 2 | Nos | 3,000 ₹6,000 | 5,000 ₹10,000 |
| 3.00 | Supply of 1000 Ltr , capacity 5mm thick shall + 6 mmthick Dish MS tank with 50mm thick Mineral wook insulation + aluminium cladding. Epoxy paitning shaould be done both inside and out side the tank. The tank shall be mounted on MS painted channel of suitble size and a height of 750 mm from ground level . | 2 | Nos | 1,00,300 ₹2.0 L | 90,000 ₹1.8 L |
| 4.00 | Installation of 1000 Ltr capacity tank mentioned in Sl no -3 . Charges inlcude unloading , shifting to third floor roof top , Erection etc. | 2 | Nos | 18,880 ₹37,760 | 6,000 ₹12,000 |
| 5.00 | Inter connecting piping between tank to heat pump and cold water line using 1" , heavy duty CPV -SDR-11(CTS) confirming to ASTMD2846 ( for SDR-11 , Host and cold water CPVC)
Pressure rating of pipe :100 psi @ 180°F (per ASTM D2846). Make : Flow Guard. Corzan or as approved by IIMB | 30 | Mtr | 1,770 ₹53,100 | 450 ₹13,500 |
| 6.00 | Brass Gate vavles suitble for 1" CPVC line with necessary metal transition fittings ( brass / stainless steel ) at the heat pump . The cost shall be inclusive of necessry union fittings on both sides. | 6 | Nos | 2,065 ₹12,390 | 1,250 ₹7,500 |
Tender Value
₹10 L
EMD Value
₹25,000
Closing Date
30 Dec 2025, 3:00 pmClosed
Chief Manager (Infrastructure)
Chief Manager (Infrastructure), Estate Section, II Floor, Admin Block, IIMB
Installation of Air Source Heat Pumps for Supply of Hot Water at MDC A1, A2 Blocks, MDC Kitchen and Hostel Mess at IIMB
2025_IIMB_888984_1
CMI/ME/102/2025-26
Open Tender
Electrical Works
45 days
IIMB Bannerghatta Road Campus, Bangalore
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹25,000
Estate Section, IIMB
16 Jan 2026
8 Dec 2025
31 Dec 2025
8 Dec 2025
30 Dec 2025
22 Dec 2025
22 Dec 2025
Amount
510 Ltr / Hour, Air source heat pump, with heating capacity of 22 kW, Heat exchanger BPHE /MCHE, Microprocess controlled , Time and temperature settable unit. Type of compressor type :Scroll. Maximum output temperature : 60 Deg. Heat exchangher - Aluminium tube , copper pipe. Type of refrigerant : R407 C . Input power : 6 kW Ouput power - 22 kW Power input - 415 V, 3 P phase. The units should be made of Powder coated CRCA sheet -16SWG . Necessary MS painted stand should be provided along with the unit. The unit must have provision to drain out water . All necessary piping interconnections to Solar water heater tank in and out are in the scope of work. Circulaiton pump of suitble capacity is included in the scope of work.
Supply of above Equipment
Erection, testing and commissioning of above Equipment
350 Ltr / Hour , Air source heat pump, with heating capacity of 16 kW , Heat exchanger BPHE /MCHE , Microprocess controlled , Time and temperature settable unit. Type of compressor type :Scroll. Maximum output temperature : 60 Deg. Heat exchangher - Aluminium tube , copper pipe. Type of refrigerant : R407 C . Input power -4.4 kW Ouput power - 16 kW Power input - 415 V, 3 P phase. The units should be made of Powder coated CRCA- 16 SWG sheet . Necessary MS painted stand should be provided along with the unit. The unit must have provision to drain out water . All necessary piping interconnections to Solar water heater tank in and out are in the scope of work.Circulaiton pump of suitble capacity is included in the scope of work.
Supply of above eqipment
Installation charges
Supply of 1000 Ltr , capacity 5mm thick shall + 6 mmthick Dish MS tank with 50mm thick Mineral wook insulation + aluminium cladding. Epoxy paitning shaould be done both inside and out side the tank. The tank shall be mounted on MS painted channel of suitble size and a height of 750 mm from ground level .
Installation of 1000 Ltr capacity tank mentioned in Sl no -3 . Charges inlcude unloading , shifting to third floor roof top , Erection etc.
Inter connecting piping between tank to heat pump and cold water line using 1" , heavy duty CPV -SDR-11(CTS) confirming to ASTMD2846 ( for SDR-11 , Host and cold water CPVC) Pressure rating of pipe :100 psi @ 180°F (per ASTM D2846). Make : Flow Guard. Corzan or as approved by IIMB
Brass Gate vavles suitble for 1" CPVC line with necessary metal transition fittings ( brass / stainless steel ) at the heat pump . The cost shall be inclusive of necessry union fittings on both sides.
Short flexible SS connectors ( braided flexible SS hose ) for absrobing virbration and thermal expaanion of 1" dia
Sunrise Solar Pvt Ltd (BID ID -3341385)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_934373.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid