Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹58.0 L+₹8.5 L (17.1%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹58.5 L+₹9.0 L (18.2%)Rejected-Finance 25A R R SAMY LANE COIMBATORE TAMILNADU COIMBATORE TAMIL NADU 641009 | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹58.8 L+₹9.3 L (18.7%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹58.9 L+₹9.4 L (18.9%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹99,800
Closing Date
1 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVN OF CERTAIN MINOR WORKS AND SANCTIONED WORKS AT AFS SULUR
2023_MES_628063_1
8621/E8
Open Tender
Miscellaneous Works
Item Rate
90 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹99,800
Yes
16 Dec 2023
11 Nov 2023
2 Dec 2023
11 Nov 2023
1 Dec 2023
25 Nov 2023
11 Nov 2023 - 22 Nov 2023
Amount
SCHEDULE A BOQ
General Notes for all items:- (a) The subject tender has been prepared by clubbing of 5 (five)works which has to be executed in domestic and technical area in different locations simultaneously.
(b) Site shall be handed over as per users requirement.
(c) Testing will be carried out in presence of users.
M&L flame proof point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through and including stove enamelled steel Conduit, ISI marked with and including new concealed modular terminal box fabricated with 1.6 mm MS sheet, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly for one light/fan/bell point controlled by one switch complete all as specified and as directed
Supply and fixing switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed
Supply and fixing LED light fitting 2X16 watt flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all specified and as directed.
S & F flame proof, weather proof exhaust fan 380 mm sweep, class 1, Zone 1, single phase 1440 RPM, rated 240 V, 50 cycle with CMR/CPRI hazhardous area gas group of IIA / IIB with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazardous front and rear guards 01 No, M-20 cable entry etc suitable for wall/bracket mounting arrangement etc duly dark grey epoxy powder coated as per shade 632 of IS -5 including writing MES No in 2 Cm height with synthetic enamel paint complete all as specified and directed.
Note for Item No 8:- The quoted rate is deemed to be inclusive for cutting holes in wall of any type suitable to fix the exhaust fan and making the disturbed wall sufaces good by rendering in cement mortar 1:4 and necessary painting.
Supply & fix Triple pole neutral, MCB 40 Amp to 63 Amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply and fixing in ceiling fans with brushless direct current motor (BLDC), five star rated, 230V, Min air delivery 210 CFM with service value 6.00 BEE., 1200 mm sweep complete with blades, down rods and fittings accessories like flexible copper cord if size 1.5 sqmm etc, including taking down exisiting ceiling fan complete all as specified and directed.
Note for Item No 11:- Old unserviceable ceiling fans shall be deposited to MES store
S&F factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified.
Supply & fix Triple pole neutral, MCB 20 Amp to 32 Amp, 415 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
Supply & fix Single pole neutral, MCB 30 Amp to 32 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and including suitable size PVC casing capping and all accessories fixed to wall / floors along with 2 runs of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 16:- (a) 4 runs of 6 sqmm cable along with 2 run of 6 sqmm cable for earth conductor and PVC casing capping shall be measured as one length.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and including suitable size PVC casing and capping and all accessories fixed to wall / floors along with 2 runs of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 18:- (a) 4 runs of 4 sqmm cable along with 2 run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix exhaust fan with steel body, AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including taking down exisiting exhaust fan complete all as specified and directed.
Note for Item No 21:- Old unserviceable Exhaust fans shall be deposited to MES store
M&L point wiring using approved colour coding as per IS with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through suitable size non metallic PVC conduit fixed on surface of wall, columns etc including PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) copper conductor as earth wire and connected to earth dolly complete all as specified and as directed for the followings complete all as specified and directed.
One light point/fan/bell point controlled by one switch
All as per item No. 23 here in before but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one switch socket outlet 3 pin 16 Amps on independent board
S & F modular switch 1 way 6 amp.1 module complete all as specified and directed.
Supply and fix modular switch 1 way 16A, 1 module complete all as specified and as directed.
Supply and fix modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed.
Supply and fix modular white cover plate 3 module complete all as specified and as directed.
Supply and fix modular metal flush box 3 module complete all as specified and as directed.
S & F ceiling rose, surface type bakelite 65x55 mm terminal complete all as specified and directed.
Supply and fix exhaust fan with steel body, AC single Phase. 230V of size 380mm sweep with, blades, and frame and louvers including taking down exisiting exhaust fan complete all as specified and directed.
Note for Item No 32:- Old unserviceable Exhaust fans shall be deposited to MES store
M & L earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised iron earth wire 4mm dia by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 15mm bore (dia) medium grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6, type C-1 using 20mm graded stone aggregate and Pre-cast RCC Cover Slab of size 300x300x40 mm in Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate, reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, returning, filling in and removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and testing complete all as per specified and directed.
Note for Item No 34:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be calibrated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone without extra cost to Govt till desired result is obtained.
Supply and fixing and testing of 1 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 130V - 290V with output voltage stabilized at 230 V with accuracy of ± 2.5%complete all as specified and directed.
S & F 25 mm bore High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. to drain out the condensed water complete all as specified and directed.
S & F rotational moulded polythene water storage tank of 500 Ltrs capacity cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet hoisted and fixed in position all as specified in SSR part -I including complete all as specified and directed.
M & L for making connection of PP-R distribution branch with PP-R main pipe line of size 16 to 40 mm outer dia by providing and fixing Tee including cutting and making fusion joint etc. complete all as specified and directed.
S & F Ball brass valves of size 25mm high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
M&L 32 mm outer dia of pipes 3-layer PP-R (Polypropylene random copolymer) pipes concealed pipes SDR 7.4 (PN-16 @ 20°C) UV stablized and anti microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings, complete to walls, ceilings or in floors etc. all as specified and directed.
Note for item No 44 :- (a) The unit rate quoted is deemed to include the cost of short lengths, with all pipe fittings such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc and fixing accessories such as pipe hooks, screws clamps etc
(b) Wall thickness of pipes shall be all as per IS : 15801
S & F 32 mm outer dia PP-R Gate Valves (Brass insert) with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
S & F Air Termination Single Pointed Aluminium Rod dia upto 12mm and length upto 300mm complete all as specified and as directed.
S & F Aluminium strip 25 x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt Magnesium Sulphate (1 : 1: 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion, complete all as per specified and as directed.
Note for Item No 50:- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester will be provided by the contractor. It should be calibrated from authorised company/ lab..
(d) After testing if desired earth resistance of less than 3 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(e) The quoted rate shall deemed to be inclusive for GI strip 32mm x 6mm and protection pipe of length up to 7.5m. The GI strip beyond 7.5 m shall be measured and paid seperately under relevant item here-in-after.
Supply and fixing and testing of 4 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% including taking down existing one complete all as specified and directed.
Supply and fixing and testing of 5 KVA capacity Voltage stablizer for automatic operation, single phase naturally air cooled , copper wound, indoor type & designed for input variation between 170V - 250V with output voltage stabilized at 230 V with accuracy of ± 2.5% including taking down existing one complete all as specified and directed.
Note for Item No 56 & 57:- Old unserviceable voltage stabilizer shall be deposited to MES store
S&F Galvanised earth strip of size 32 x 6mm fixed on proper post insulator at the instrument end complete all as specified and directed.
Supply and fix GI pipe 40 mm bore light grade as supporting pipe for air termination rod with necessary cutting and fixing arrangements fo fix with roof including necessaru Concrete foundation etc complete all as specified and as directed by Engr-in-Charge.
Supply, installation, commissioning of Water cooler, fully stainless steel, electric driven single phase having approx storage of 80 liters and nominal cooling capacity including taking down exisiting water cooler complete all as per manufacturers instructions and directed by Engineer-in-Charge.
Note for Item No 61:- Old unserviceable water cooler shall be deposited to MES store
Supply and fixing and testing Servo Controlled Automatic Voltage stabilizer of capacity 25 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±1% and speed of correction 50 Volts per second including taking down existing one complete all as specified and directed.
Supply and fixing and testing Servo Controlled Automatic Voltage stabilizer of capacity 75 KVA for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ±1% and speed of correction 50 Volts per second including taking down exisiting one complete all as specified and directed.
Note for Item No 63 & 64:- Old unserviceableservo controlled stabilizer shall be deposited to MES store
S & F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw complete all as per specified and as directed.
S & F Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed
Supply & fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp complete all as specified and directed
Supply & fix single pole MCB 6 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and directed.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including suitable size PCV casing capping and all accessories fixed to wall / floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
Note for Item No 70:- (a) 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and PVC casing capping shall be measured as one length.
devan enterprises
rvelectricals
SUPER COOL
KUMAR AGENCIES
D.R ASSOCIATES
Neptune Engineers and Builders
Lucky Enterprises
A.GOVINDARAJ
T C KARUNANITHI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .