| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC | ₹9.9 L Quoted ₹10.3 L | L1 | Accepted-AOC Due to lowest bidder |
| 2 | L2₹10.8 L+₹48,833 (4.72%)Rejected-Finance | ₹10.8 L+₹48,833 (4.72%) | L2 | Rejected-Finance Due to other than lowest bidder |
| 3 | L3₹11.0 L+₹64,867.55 (6.28%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹11.0 L+₹64,867.55 (6.28%) | L3 | Rejected-Finance Due to other than lowest bidder |
| 4 | L4₹11.1 L+₹74,887 (7.25%)Rejected-Finance MASTER BUILDING DALHOUSIE ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹11.1 L+₹74,887 (7.25%) | L4 | Rejected-Finance Due to other than lowest bidder |
| 5 | L5₹11.6 L+₹1.3 L (12.3%)Rejected-Finance | ₹11.6 L+₹1.3 L (12.3%) | L5 | Rejected-Finance Due to other than lowest bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Aug 2021, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
CWE/P-07/2021-22 REPAIR AND MAINTENANCE OF HT OVERHEAD LINES, HT UG CABLE AT JANGLOT, MADHOPUR AND BASOLI STATION UNDER GE BASOLI
2021_MES_457181_2
CWE/P-07/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Basoli
class E and above Category (b) (ii)
10 documents required · 10 mandatory
₹500
GE Basoli
₹30,000
Yes
11 Oct 2021
2 Aug 2021
1 Sept 2021
2 Aug 2021
30 Aug 2021
16 Aug 2021
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for laying of UG cable and getting out in soft/loose of soil, complete all as specified and directed.
All as per Srl item no 1 here-in-before but exc 1.5 metre but n. exc 3.0 metre deep, complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point, complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and directed.
M&L for PCC ( 1:2:4) type B1 using 20mm graded crushed stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface, completed all as specified and directed.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded crushed stone aggreghate for foundation of poles and stay assembly, completed all as specified and directed.
Supply, laying, commissioning and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable with aluminium stranded conductor of 6.35/11 KV suitable for 11000 Volts grade, cross-sectional area 95 Sqmm 3 core, complete all as specified and directed
S&F DWC high density polyethelene pipes having dia 120 x 103 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930 (Part I & II) for protection of underground cable laid along pole / along wall in PCC on GL/roof and including all fittings as required at site, comp[lete all as specified and directed.
M&L for cable end jointing kit for 11 KV (earthed) grade cable for out door type termination cold shrinkable type joint complete with all joint material and ccessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm, complete all as specified and directed.
M&L for HT lightening arrestor for outdoor use, expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amps, minimum work pressure 11000 volts grade conforming to IS, complete all as specified and directed.
S&F outdoor type triple pole, 11000 Volts mechanically operated air brake switch, mounted on 15 Nos polimer insuators including drop out type fuse unit with fuses of suitable rating and steel frame, with operating mechanism worked from ground level from current rating up to 200 Amps and all accessories, complete all as specified and directed.
M&L for structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat, one finishing coat of aluminium paint and epoxy coating sufficient for 11 KV insulation, complete all as specified and directed.
S&F disc type composite polymer insulators, specified mechanical load 45 KN (min) P F (dry) withstand voltage 65 KV/mint, P F (wet) withstand voltage 40 KV/mint, impulse withstand voltage 80 KVP for tension with tension clamp for conductors working pressure 11000 Volts, complete all as specified and directed.
S&F pin type polymer insulator 11 KV, 45 KN, 320 mm max creep including galvanised mild steel strap, washer and one galvanised iron nut of suitable size for 11000 volts, complete all as specified and directed.
M&L for aluminium conductor steel re-inforced (ACSR) of any size for HT lines on PCC/Steel Tubular poles, stretching without kinks and bends, binding with (rates inclusive) binding wire, complete all as specified and directed.
M&L for galvanised steel wire 4 mm dia, complete all as specified and directed.
S/F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanised stay rod threaded and with nuts including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I 2009, complete including taking down U/S stay assembly all as specified and directed. Note : Loop type insulator, stay clamp, stay wire, excavation and concrete work measured separately).
S & F galvanised steel stranded stay wire size 7/4mm for stay assembly, complete all as specified and directed.
M&L for Anti climbing devices; comprising 2.24 mm dia galvanised steel 2-srand barbed wire wih 2.00mm dia barbs wrapped spirally round poles, to a lengh of 0.5 to 1.0 metre clammped and properly secured or as ordered (clamps measured separately), complete all as specified and directed.
M&L for Anti-climbing device;spikes type fabricated out of M. S bars (round, square and flat) including nuts, bolts, washers and welding in wo halves made to shape to suit the cross section of the pole, complete all as specified and directed.
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter,figures and conventional skull and bones in signal red colour and fix with MS clamps, bolts and nuts of approved size, for HT 25x20 cm, complete all as specified and directed.
S & F for Cradels, hexagonal/rectangular, fabricated and for streatching GI steel wire 4 mm dia including for pole to pole with binding wire in location/ area given by the incharge, complete all as specified and directed.
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial welded with MS sheet at top as specified type 410 SP-55 (11 metres long) including painting the pole with two coats of aluminium paint over a coat of red oxide paint including making five nos of black and yellow strips 30 cm wide above PCC coping, complete all as specified and directed. Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under respective items of BOQ/ Sch 'A'.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009, complete all as specified and directed. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009, complete all as specified and directed.
M&L for construction of platform of size 3000 x 2500 x 1500 mm for transformer having side finished, PCC (1:4:8) up to 30 CM in foundation and PCC at top portion of platform upto 25 CM thick with suitbale size MS bars, brickwork and cement mortar (1:4) and complete plaster work 15 mm thick to exposed surface in CM including (1:4) including necessary MS work (i.e. MS jali/fencinfg/MS angle) on the top of platform around transformer upto height 3 feet, complete all as shown on Drawing No CEPZ/C-TD/002/13 dt 2/5, complete all as specified and directed.
Disconnecting all electric/ earthing connection of old serviceable transformer and lifting and shifting to another places on platform carefully by crane and connecting properly with HT/LT cables and earthing strips and testing, complete all as specified and directed by engr-in-charge.
Dismantling and taking down old existing ACSR conductor any type from existing HT/LT pole, complete all as specified and directed by Engr-in-charge
Dismantling of steel work ( brackets,clamps, channels including disc and pin insulators, nut & bolts) from existing pole, complete all as specified and directed by Engr-in-Charge.
Dismantling insulators any type, any size and depositing to the MES store yard, complete all as specified and directed.
Dismantling of stay wire / earth wire, complete all as specified and directed.
Taking down existing HT/LT pole 11 mtr long PCC/steel including earth work and PCC of the poles, complete all as specified and directed by Engr-in-charge
Taking down OH/UG/AB cable any type any size including earth work and staging in safe manners for reuse in work where required, complete all as specified and directed.
Relaying the cable of any size in trenches after repair including all electrical connection etc, complete all as specified and directed. Note:- Excavation, earth work and sand cushioning paid separately respective items.
M&L for painting of existing steel tubular HT pole one coats of aluminium prime paint including making strips 1.5m above ground level by black yellow paint in alternate layers and numbering of poles, complete all as specified and directed.
Trimming/cutting tree branches with clearing space upto 2 metre from the over head conductor's any side , all around for HT/LT distribution system, complete all as specified and as directed. Note- (i) Electrician shall be taken shutdown from JE Incharge and proper enter in to the shut down register at Power house and complete the work within the time, and clear the shut down from main power house after completion of the work.
M&L for surface dressing not exceeding 15 cm deep around 2 pole / 4 pole structure, feeder pillar box and transformer DG set platform plinth and out side Sub Station Building etc, complete all as specified and directed.
Restretching of existing loose OH, HT ACSR conductor wire including GI wire along the span of poles for sagging with the permissible limit including binding/rebinding/joining with aluminium winding woire in case of breakage of conductor, size of winding wire shall not be less than 2 Sqmm, complete all as specified and directed.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
SHUSHANT ASSOCIATES
kailu construction co
INDIA ELECTRIC WORKS
dinesh enterprises
G.M. ENGINEERING SERVICES
TRIVENI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .