Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹7.2 L (5.90%)Admitted-Finance | ₹1.3 Cr+₹7.2 L (5.90%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MARINE AUTOMATION L2 | GROMOS INDIA L1 |
|---|---|---|---|---|---|
| 1.00Deployment and operation of Four wheeler (5 seater) with driver as per TSS 1 | |||||
| 1.10 | Deployment of above said Vehicle | 600 | Per Day | 1,575 ₹9,45,000 | 1,450 ₹8,70,000 Lowest |
| 1.20 | Operation of above said vehicle | 18,000 | Km | 16 ₹2,88,000 Lowest | 25 ₹4,50,000 |
| 2.00Servicing and maintenance of electrical utilities as per TSS 2 | |||||
| 2.10 | S&M of Main panels up to 20 feeders. | 72 | Each | 8,400 ₹6,04,800 Lowest | 11,000 ₹7,92,000 |
| 2.20 | S&M of Sub panels up to 10 feeders. | 84 | Each | 5,250 ₹4,41,000 Lowest | 8,500 ₹7,14,000 |
| 2.30 | S&M of Change over panels with 2 feeders. | 12 | Each | 2,625 ₹31,500 Lowest | 4,500 ₹54,000 |
| 2.40 | S&M of Distribution boards. | 300 | Each | 525 ₹1,57,500 Lowest | 6,500 ₹19,50,000 |
| 3.00 | Maintenance of Lightning arrestor as per TSS 3 | 50 | Each | 525 ₹26,250 Lowest | 2,000 ₹1,00,000 |
| 4.00 | Maintenance of Earth station as per TSS 4 | 300 | Each | 735 ₹2,20,500 Lowest | 4,500 ₹13,50,000 |
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
24 Sept 2024, 6:00 pmClosed
Chief Engineer and Director, ESG
Chief Engineer and Director, ESG, CED, BARC, Trombay
Maintenance and Addition/Alteration of Electrical Installations of various buildings at North site, BARC, Trombay, Mumbai-85
2024_BARC_824859_1
BARC/TSD/ET/24/2024-2025
Open Tender
Electrical Works
Item Rate
730 days
BARC, Trombay, Mumbai- 400085
As per NIT and tender documents
6 documents required · 6 mandatory
₹0
₹3.1 L
Conference Room, 2nd FL, TSD
18 Oct 2024
9 Sept 2024
30 Sept 2024
9 Sept 2024
24 Sept 2024
9 Sept 2024
9 Sept 2024 - 19 Sept 2024
17 Sept 2024
Amount
Deployment and operation of Four wheeler (5 seater) with driver as per TSS 1
Deployment of above said Vehicle
Operation of above said vehicle
Servicing and maintenance of electrical utilities as per TSS 2
S&M of Main panels up to 20 feeders.
S&M of Sub panels up to 10 feeders.
S&M of Change over panels with 2 feeders.
S&M of Distribution boards.
Maintenance of Lightning arrestor as per TSS 3
Maintenance of Earth station as per TSS 4
SITC of Spare parts as per TSS 5
20A 3Pin Metal clad Socket & plug Top
5/10A, 3pin plug top
15/20A 3pin plug top
120W fan stap regulator modular type.
6/10A, SP Modular switch.
16/20A, SP modular switch with indicator
6/10A, 5 pin modular socket.
16/20A, 5 pin modular socket.
3/4 Modular plate with box
6 Modular plate with box
8 Modular plate with box
12 Modular plate with box
6 to 20 A SP MCB
16 to 32 A DP MCB
40A TP MCB D-curve
63A TP MCB D-curve
40 A FP MCB,D-curve
63 A FP MCB D-curve
32 to 40 A, 30 mA DP RCCB
63 A, 30 mA DP RCCB
40 A, 30 mA FP RCCB
63 A, 30 mA FP RCCB
125 A FP, 36KA, MCCB
8 Modular plate with accessories for DLP
Hylem sheet 3mm
TubeLight Starter 110/230V
Capacitor for fan
FRP Box with elemax connector (4 inchX4inch approx)
Flameproof switch(10A) with box
SITC of Light point wiring as per TSS 6
Primary switch box points with 2.5sqmm FRLS wire
Secondary switch box points with 2.5Sqmm FRLS wire
Primary lighting points with 1.5Sqmm FRLS wire
Secondary lighting points with 1.5Sqmm FRLS wire
Ceiling fan point With 1.5Sqmm FRLS wire
200/225mm Exhaust fan point With 1.5Sqmm FRLS wire , switch and socket
Exhaust fan point With 1.5Sqmm FRLS wire with 2P MCB and metal socket
SITC of Power point wiring as per TSS 7
Primary power points with 2.5sqmm FRLS wire
Secondary power points with 2.5sqmm FRLS wire
Power point for A/C and geyser with 4.0sqmm FRLS wire
Primary power points in DLP
Secondary power points in DLP
SITC of Lighting fixtures as per TSS 8
20 watts LED lighting fixture
40 watts LED lighting fixture
38 Watts Fullglow LED lighting fixture Recessed type.
70/75W LED Lighting fixture outdoor type.
35/36W LED Lighting fixture outdoor type.
150W LED Flood Lighting fixture outdoor type.
9 watts LED Bulkhead Lighting fixture.
10W LED Lighting Fixtures Recessed Type.
10W LED Lighting Fixtures 2fts for toilet area batten type
20 W flame proof LED Lighting fixture
SITC of Fans as per TSS 9
1200 Sweep Ceiling fan powered by BLDC motor with remote/regulator
Wall fan BLDC, sweep 400mm
Padestal fan BLDC, sweep 400mm
Exhaust fans BLDC, Sweep 205/225mm
Air circulator fan, sweep 750mm
Exhaust fan 300mm
Exhaust fan 450mm
Flame proof Exhaust fan sweep 9/12 inch
SITC of PVC conduit/ casing capping as per TSS 10
25mm PVC rigid conduit
25mm PVC flexible conduit
32mm X 12mm casing capping
150mm X 50mm DLP Trunking
Floor mounting casing capping suitable for one circuit of 2.5sqmm wire
SITC of Wiring with PVC FRLS copper wire as per TSS 11
1.5 Sq.mm PVC FRLS copper wire
2.5 Sq.mm PVC FRLS copper wire
SITC of Distribution Boards as per TSS 12
8 Way, TPN DBs with RCCB as PPI.
6 Way, TPN DBs with RCCB as PPI.
8 Way, VTPN DBs with 125A MCCB as incomer.
SITC of End termination as per TSS 13
4 C x 2.5/4/6 Sq.mm
4 C x 10/16 Sq.mm
3.5C/4 C x 25/35 Sq.mm
3.5 C x 50/70/95 Sq.mm
3.5 Core x 150/185 sq.mm.
3.5 Core x 300sq.mm.
3.5 Core x 400 sq.mm.
SITC of RCBO/MCB/MCCB with MS Enclosure as per TSS 14
32 Amp. FP, MCB, D-curve
63 Amp. FP, MCB, D-curve
125 Amp. 25KA, FP, MCCB
32 Amp. FP, RCBO, 30mA
63 Amp. FP, RCBO, 30mA
10 Amp, 2P, MCB, C-curve
SITC of Earth station as per TSS 15
SITC of Earthing strip/wire as per TSS 16
14 SWG copper wire
25mm x3 mm copper strip
SITC of MS box as per TSS 17
SITC of MS supports as per TSS 18
SITC Portable emergency light (LED) as per TSS 19
SITC of Extension Board as per TSS 20
Only installation of cable as per TSS 21
On Surface-Only installation of cable of size 4 C x 2.5/6/10 sq.mm
On surface-Only installation of cable of size 4 C x 16 / 25 sq.mm.
On surface-Only installation of cable of 4C or 3&½C x 50sq.mm. - to -95 sq.mm.
Underground-Only installation of cable of size 4 C x 2.5/10/16 / 25 sq.mm
Underground-Only installation of cable of 4C or 3&½C x 50sq.mm. - to -185 sq.mm.
Temporary Power Supply connection as per TSS 22
Temporary Power Supply connection with 2.5 to 25 Sqmm cable/TRS wire
Temporary Power Supply connection with 50 to 400 Sqmm cable
Painting of DB/Outdoor Panel/switch Box/Exhaust fan as per TSS 23
SITC of Insulating mat as per TSS 24
SITC of Straight through Joints as per TSS 25
3.5C/4 C x 10-to-25 Sq.mm
3.5C/4 C x 50-to-95 Sq.mm
3.5C/4 C x 185 Sq.mm
3.5C/4 C x 300-400 Sq.mm
Fault finding Work of LT cable of 4C/ 3 & ½ C x 25 to 400 Sqmm Cable as per TSS 26
Excavation work as per TSS 27
Soft Soil
Hard Rock/Road
Electrical Job Rectification as per TSS 28
SITC of lightening discharge receiver ( Air Terminal) as per TSS 29
Only removal of casing capping/ conduits/ cables up to 25 sqmm as per TSS 30
Only removal of DBs/switch boxes/fans/lighting fixture etc. as per TSS 31
Diagnoses and repair of Display modules of PCC as per TSS 32
SITC of Outdoor Feeder pillar as per TSS 33
Providing , supplying JCB (Loader cum excavation) including operator and helper executing the work like excavation, grading, levelling, debris cleaning and other works at various locations inside BARC Trombay as instructed by EIC as per TSS 34
Providing and supplying hydra crane 08 MT capacity for collection and transportation of scrap materials , unservicable equipments, furniture, debris, garrbage at various locations inside BARC Trombay as instructed by EICas per TSS 35
Providing and supplying forklifts 03MT capacity for collection and transportation of scrap materials , unservicable equipments, furniture, debris, garbage at various locations inside BARC Trombay as instructed by EIC as per TSS 36
Supplying manpower alongwith necessary spades, shovels, pujas, ropes, small special spades, rain coats, broom , mop etc min two labours per day and max any number as and when decided by EIC to work for eight hours per day to carry out the cleaning work, loading work etc. as directed by EIC as per TSS 37
SITC of SS Wire Mesh with SS Frame for Exhaust Fan as per TSS 38
SS wire mesh (approx 4 Sqft) with suitable length of SS frame(approx thickness 3mm and width 25mm) to cover the exhaust fan (in BOX manner) from inside
SS wire mesh (approx 2 Sqft) with suitable length of SS frame(approx thickness 3mm and width 25mm) to cover the exhaust fan from outside.
MARINE AUTOMATION
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 15.24 MB
TECHNICAL_BID.xls
Tender Documents • 0.27 MB
Proforma_of_schedules.pdf
Tender Documents • 0.13 MB
Specifications24.pdf
Tender Documents • 0.35 MB
Certificateformakeinindiaandsourceofcountry.pdf
Tender Documents • 0.33 MB
BOQ_866829.xls
BOQ • 0.30 MB
Tender_document.pdf
Tender Documents • 1.37 MB
SCHEDULEA.pdf
Tender Documents • 0.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .