Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹5.1 Cr 34 A METCALFE STREET 4TH FLOOR SUITE NO 4F 1 KOL 700013 MBL 9007168216 9007818748 | ₹5.1 Cr |
Tender Value
₹5.3 Cr
EMD Value
₹5.3 L
Closing Date
22 Jul 2024, 3:00 pmClosed
Construction of DIC Office Building and Modification or Renovation of Existing Office Building at SAILDSP, Durgapur
NBCC/RBGWB/SAIL-DSP/2024/339
NBCC/RBGWB/SAIL-DSP/2024/339
Open Tender-Domestic
Civil Works General
Shimla, Himachal Pradesh
₹11,800
₹5.3 L
31 Jul 2026
8 Jul 2024
22 Jul 2024
22 Jul 2024
3 Aug 2024
ABSTRACT OF COST
Construction of DIC Office Building and Modification / Renovation of Existing
Office Building at SAIL-DSP, Durgapur
SL.NO. PARTICULARS
1 DIC OFFICE BUILDING
1.1 Civil Works 22,064,447
1.2 Interior Renovation & Finishing Works 13,852,736
2 Internal Plumbing Works 1,498,997
3 Internal Elec. & VRF System 14,271,591
4 Repairs & Renovation Works Of Existing DIC Building. 1,090,913
5 Addressable Fire Detection & Alarm System 712,354
(Rupees Five Crore Thirty Four Lakh Ninety One Thousand Thirty Eight Only)
Digitally signed by SILKI
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
Sl. No. DOR-2023 DESCRIPTION UNIT QTY. MR RATE DSR AMT. NSOR Amount
A 2.00 EARTH WORKS
1 2.6 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over
areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed
by Engineer-in-charge.
i 2.6.1 All kinds of soils Cum 989.04 177.50 175,554.07
2 2.7 Earth work in excavation by mechanical means (Hydralic excavator/manual means)over
areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed
by Engineer - in Charge
2.2 2.7.3 Hard rock (blasting prohibited) Cum 10.00 1432.95 14,329.50
3 2.10 Excavating trenches of required width for pipes, cables, etc. including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out
the excavated soil, and then returning the soil as required, in layers not exc
a 2.10.1 All kinds of soil.
i 2.10.1.2 Pipes, cables, etc. exceeding 80mm dia but not exceeding 300mm dia. Metre 10.00 352.15 3,521.50
4 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations
etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming
and watering, lead up to 50 m and lift upto 1.5 m. Cum 729.17 196.00 142,917.61
5 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming,
consolidating and dressing complete.
6 2.28 Surface dressing of the ground including removing vegetation and inequalities not
exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
i 2.28.1 All kinds of soil Sqm 362.39 34.15 12,375.78
7 2.34 Supplying chemical emulsion in sealed containers including delivery as specified
i 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% Litre 40.00 234.75 9,390.00
8 2.35 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite
treatment (excluding the cost of chemical emulsion) :
i 2.35.1.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres /
sqm of the vertical surface of the substructure to a depth of 300mm including excavation
channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20%
with 1% concentration Metre 70.00 38.90 2,723.00
a) 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300
mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1
cement : 2 Coarse sand) to match the existing floor:
i 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 80.00 310.05 24,804.00
TOTAL (Carried Over to Summary of Civil Works) 476,720.19 0.00
B 4.00 CONCRETE WORKS
1 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of
centering and shuttering - All work up to plinth level :
b 4.1.5 1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from
natural sources : 6 graded stone aggregate 20 mm nominal
size derived from natural sources) Cum 60.15 7294.70 438,780.36
2 4.11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1
cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate
20mm nominal size derived from natural sources). Sqm 13.83 495.75 6,853.74
3 4.12 Extra for providing and mixing water proofing material in cement concrete work in doses
by weight of cement as per manufacturer's specification. Per 50 kg cement 4.00 18.15 72.60
4 4.13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved
quality using 1.7kg per square metre on damp proof course after cleaning the surface with
brushes and finally with a piece of cloth lightly soaked in kerosene oil.
5 4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand
(zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry
brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine
sand, including necessary excavation, levelling & dressing & finishing the top smooth.
TOTAL (Carried Over to Summary of Civil Works) 481,445.73 0.00
C 5.00 REINFORCED CEMENT CONCRETE WORK
1 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete. Sqm 337.99 392.15 132,540.82
b 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses
c 5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 790.90 927.25 733,364.71
e 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 679.06 736.40 500,063.10
f 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm 392.23 961.30 377,052.62
g 5.9.7 Stairs, (excluding landings) except spiral-staircases. Sqm 115.90 764.95 88,657.71
j 5.9.16 Edges of slabs and breaks in floors and walls
5.9.16.1 Under 20 cm wide Metre 0.00 208.55 0.00
k 5.9.19 Weather shade, Chajjas, corbels etc., including edges. Sqm 0.00 951.10 0.00
2 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level.
i 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 27483.85 107.85 2,964,132.95
3 5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete above plinth level.
i 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 34202.82 107.85 3,688,773.96
4 5.33.1 Providing and laying in position ready mixed or site batched design mix cement concrete
for reinforced cement concrete work; using coarse aggregate and fine aggregate derived
from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and workability without impairing strength; including
pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost
of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-
charge; for the following grades of concrete. Note: Extra cement up to 10% of the
minimum specified cement content in design mix shall be payable separately. In case the
cement content in design mix is more than 110% of the specified minimum cement
content, the contractor shall have discretion to either re-design the mix or bear the cost of
a) 5.33.1 All works upto plinth level.
i 5.33.1.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 254.85 9504.75 2,422,324.74
b) 5.33.2 All works above plinth level upto floor V level.
i 5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum Cum 218.41 9860.40 2,153,650.00
5 5.35 Add for using extra cement in the items of design mix over and above the specified
cement content therein. quintal 44.42 733.50 32,582.15
TOTAL (Carried Over to Summary of Civil Works) 13,114,121.01 0.00
D 6.00 BRICK WORK
1 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundation and plinth in:
i 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 4.15 7132.25 29,581.01
Sl. No. DOR-2023 DESCRIPTION UNIT QTY. MR RATE DSR AMT. NSOR Amount
2 6.34 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10
average compressive strength in super structure above plinth level up to floor V level in :
i 6.34.2 Cement mortar 1:6 (1 cement : 6 Coarse sand) Cum 128.52 8752.55 1,124,893.38
3 6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conformingio
IS :12894, in super structure above plinth and upto floor V level.
3.1 6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Sqm 92.41 1105.80 102,182.91
4 6.15 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course
of half brick masonry. Sqm 92.41 104.80 9,684.18
TOTAL (Carried Over to Summary of Civil Works) 1,266,341.49 0.00
E 10.00 STEEL WORK
1 9.48.2 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S.
flats, square or round bars etc. including priming coat with approved steel primer all
complete.Fixed to openings /wooden frames with rawl plugs screws etc. Kg 193.68 238.35 46,163.63
2 10.18 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp,
of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top
surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet
box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall
be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
3 10.25.1 Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required. In stringers, treads, landings etc. of stair
cases, including use
of chequered plate wherever required, all complete Kg 528.12 220.65 116,529.68
TOTAL (Carried Over to Summary of Civil Works) 165,165.31 0.00
F 11.00 FLOORING WORK
1 16.89 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water
absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours
and shades in for outdoor floors such as footpath, court yard, multi modals location etc.,
laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes &
patterns including grouting the joints with white cement mixed with matching pigments etc.
complete as per direction of Engineer-in-Charge.
TOTAL (Carried Over to Summary of Civil Works) 464,198.96 0.00
G 13.00 FINISHING WORK
1 13.4 12 mm cement plaster of mix :
2 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement
: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine
3 5.3 Add or deduct for plaster drip course/ groove in or moulding to R.C.C.
projections.plastered surface metre 108.20 78.40 8,482.88
4 13.16 6 mm cement plaster of mix :
5 13.21 Extra for providing and mixing water proofing material in cement plaster work in proportion per bag of 50KG
recommended by the manufacturers. Cement Used in Mix 373.43 22.10 8,252.86
6 13.47.1 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of
required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and
including priming coat of exterior primer applied @ 0.90 litre/10 sqm) Sqm 747.38 171.10 127,877.30
TOTAL (Carried Over to Summary of Civil Works) 904,374.45 0.00
H 21.00 ACP WORK STRUCTURAL GlAZING WORKS
1 8.32 Designing, fabricating, testing, installing and fixing in position Curtain
Wall with Aluminium Composite Panel Cladding, with open grooves for
linear as well as curvilinear portions of the building , for all heights and all
levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for
pressure equalisation or rain screen principle as required, proper drainage
of water to make it watertight including checking of all the structural and
functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium
composite panel cladding in pan shape in metalic colour of approved
shades made out of 4 mm thick aluminium composite panel material
consisting of 3 mm thick FR grade mineral core sandwiched between
two Aluminium sheets (each 0.5 mm thick). The aluminium composite
panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of approved colour and shade
on face# 1 and polymer (Service) coating on face# 2 as specified using
stainless steel screws, nuts, bolts, washers, cleats, weather silicone
sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 I MS with Hot
Dip Galvanised with serrations and serrated washers to arrest the wind
load movement, fasteners, SS 316 Pins and anchor bolts of approved
make in SS 316, Nylon separators to prevent bi-metallic contacts all
complete required to perform as per specification and drawing The item
includes cost of all material & labour component, the cost of all mock
ups at site, cost of all samples of the individual components for testing
in an approved laboratory, field tests on the assembled working curtain
wall with aluminium composite panel cladding, cleaning and protection of
the curtain wall with aluminium composite panel cladding till the handing
over of the building for occupation. Base frame work for ACP cladding
is payable under the relevant aluminium items. The Contractor shall
provide curtain wall with aluminium composite panel cladding, having
all the performance characteristics all complete , as per the Architectural
drawings, as per item description, as specified, as per the approved shop
drawings and as directed by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on the external face of the
curtain wall with Aluminum Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two decimal places. Sqm 439.00 5015.05 2,201,606.95
Sl. No. DOR-2023 DESCRIPTION UNIT QTY. MR RATE DSR AMT. NSOR Amount
2 25.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per
the architectural drawings and approved shop drawings , the aluminium quality as per
grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80
microns conforming to AAMA 2604 of required colour and shade as approved by the
Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws
etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be
paid on this account). The weight of aluminium extruded section shall be taken for purpose
25.2 Designing, fabricating, testing, protection, installing and fixing in position
semi (grid) unitized system of structural glazing (with open joints) for
linear as well as curvilinear portions of the building for all heights and all
levels, including:
(a) Structural analysis & design and preparation of shop drawings for the specified design
loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times
design wind pressure without any failure), including functional design of the aluminum
sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and
splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc.,
structural and weather silicone sealants, flashings, fire stop (barrier)-
cum-smoke seals, microwave cured EPDM gaskets for water tightness,
pressure equalisation & drainage and protection against fire hazard
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005
T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional
movement for achieving perfect verticality and fixing structural glazing system rigidly to the
RCC/ masonry/structural steel framework of building structure using stainless steel anchor
fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc.
of stainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant
and one part weather silicone sealant compatible with the structural
silicone sealant of required bite size in a clean and controlled factory /
work shop environment, including double sided spacer tape, setting
blocks and backer rod, all of approved grade, brand and manufacture, as per the
approved sealant design, within and all around the perimeter for holding glass.
(d) Providing and fixing in position flashings of solid aluminium sheet 1
mm thick and of sizes, shapes and profiles, as required as per the site
conditions, to seal the gap between the building structure and all its
interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the
curtain glazing system to make it watertight, by incorporating principles
of pressure equalization, providing suitable gutter profiles at bottom (if
required), making necessary holes of required sizes and of required
numbers etc. complete. This item includes cost of all inputs of designing, labour for
fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding
and other incidental charges including wastages etc., enabling temporary structures and
services, cranes or cradles etc. as described above and as specified.
The item includes the cost of getting all the structural and functional
design including shop drawings checked by a structural designer, dully
approved by Engineer-in-charge. The item also includes the cost of all
mock ups at site, cost of all samples of the individual components for
testing in an approved laboratory, field tests on the assembled working
structural glazing as specified, cleaning and protection till the handing
over of the building for occupation. In the end, the Contractor shall provide a water tight
structural glazing having all the performance characteristics etc. all complete as required,
as per the Architectural drawings, as per item description, as specified, as per the
approved shop drawings and as directed by the Engineer- in-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow
boxes, extruded aluminium section capping for fixing in the grooves of
the curtain glazing and vermin proof stainless steel wire mesh shall be
paid for separately under relevant items under this sub- head. However,
for the purpose of payment, only the actual area of structural glazing
(including width of grooves) on the external face shall be measured in
sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural
glazing system if area of structural glazing exceeds 2500 Sqm from the
certified laboratories accreditated by NABL(National Accreditation Board
for Testing and Calibration Laboratories), Department of Science &
Technologies, India. Cost of testing is payable separately.
Note:-2. The following performance test are to be conducted on structural
glazing system if area of structural glazing exceeds 2500 Sqm from the
certified laboratories accreditated by NABL(National Accreditation Board
for Testing and Calibration Laboratories), Department of Science &
Technologies, India. Cost of testing is payable separately.
The NIT approving authority will decide the necessity of testing on the
basis of cost of the work, cost of the test and importance of the work.
Performance Testing of Structural glazing system Tests to be conducted in the NABL
accredited lab or any other accreditation body which operates in accordance with ISO/IEC
17011 and accredits labs as per ISO/IEC 17025 1. Performance Laboratory Test for Air
Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing
method for a range of testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method
for a range up to 2000 ml.
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05
testing method for a range upto 2000 ml
4. Structural Performance Deflection and deformation by static air
pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10
testing method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing
method for Qualitative test, Tests to be conducted on site.
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa
(35psi) upto 2000 ml
Sl. No. DOR-2023 DESCRIPTION UNIT QTY. MR RATE DSR AMT. NSOR Amount
3 25.3 Providing, assembling and supplying vision glass panels (IGUs)
comprising of hermetically-sealed 6-12- 6 mm insulated glass (double
glazed) vision panel units of size and shape as required and specified,
comprising of an outer heat strengthened float glass 6 mm thick, of
approved colour and shade with reflective soft coating on surface # 2 of
approved colour and shade, an inner Heat strengthned clear float glass
6 mm thick, spacer tube 12 mm wide, dessicants, including primary seal
and secondary seal (structural silicone sealant) etc. all complete for the
required performances, as per the Architectural drawings, as per the
approved shop drawings, as specified and as directed by the Engineerin-
Charge. The IGUs shall be assembled in the factory/ workshop of the
glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost
of item No.25.2)
For payment, only the actual area of glass on face # 1 of the glass panels
(excluding the areas of the grooves and weather silicone sealant) provided
and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6 mm thick substrate with reflective soft
coating on face # 2, + 12 mm Airgap + 6 mm Heat Strengthened clear
Glass of approved make having properties as visible Light transmittance
(VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection
external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0
to 3.3 W/m2 degree K etc. The properties of performance glass shall be
decided by technical sanctioning authority as per the site requirement.
4 25.4 Extra for openable side / top hung vision glass panels (IGUs) including
providing and supplying at site all accessories and hardwares for the
openable panels as specified and of the approved make such as heavy
duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel
plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts,
bolts, washers etc. all complete as per the Architectural drawings, as per the approved
shop drawings, as specified and as directed by the Engineer- in-Charge.
5 MR -1 Providing and fixing of Aluminium vertical Louver System
fabricate Using Aluminium tube 50X50MM rate includes all
hardware ,fastener and strengthening arrangement as per
approval of the Engineer-in charge, all complete.
6 MR -2 Designing, supplying, fabricating and erecting in position, point
fixed glass for canopy with 8MM clear Float toughened + 1.5 to
PVB Clear laminated + 8MM clear Float toughened glass of Saint
Gobain/Equivalent Make. The system should be designed to
withstand the wind pressure of 160 KG/SQ.MTR confirms to IS
875-1987(Part III). The entire glazed canopy will be flush on the
label and SS spider fitting in true line and slope. All holes in the
glass shall be drilled in cone shape. All the glass expansion joints
to be sealed with clear UV proof structural silicon sealant. All the
gap between glass to be sealed, whether sea land. The cost
include all labour materials, bolts, and nuts Tools tackles hosting
machines. Equipment’s, transportation, etc. Complete the
system salvage test to perform as per specific including all
material test. The coat rate shall include all design engineering
and shop drawing. Approved from engineer in charge, architect
before commissioning the work. Note: payment shall be made as
per actual measurement after completion of work Sqm 7.10 12335.00 87,578.50
7 MR-3 Providing and fixing MS WORK incliding primer one coat & enalam paint two coat.
complete as per direction of Engineer-in-Charge.
8 14.72 Providing and fixing double scaffolding system (cup lock type) on the
exterior side, up to seven story height made with 40 mm dia M.S. tube
1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock
system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the
scaffolding for working platform etc. and maintaining it in a serviceable condition for the
required duration as approved and removing it there after. The scaffolding system shall be
stiffened with bracings, runners, connection with the building etc wherever required for
inspection of work at required locations with essential safety features for the workmen etc.
complete as per directions and approval of Engineer-in-charge. The elevational area of the
scaffolding shall be measured for payment purpose.
The payment will be made once irrespective of duration of scaffolding. Note: - This
item to be used for maintenance work judicially, necessary
deduction for scaffolding in the existing item to be done.
TOTAL (Carried Over to Summary of Civil Works) 2946657.70 352908.94
I 22.00 WATER PROOFING
1 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by
applying cement slurry mixed with water proofing cement compound consisting of applying
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with
water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure
for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water
proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4
hours followed with water curing for 48 hours. The rate includes preparation of surface,
treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer
mixed slurry. SQM 18.18 617.05 11,216.12
2 22.7 Providing & laying integral cement based water proofing treatment including preparation of
surface as required for treatment of roofs, balconies, terraces etc consisting of following
operations: a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed
with water proofing compound confirming to IS. 2645 and approved by Engineer-in-charge
over the RCC slab including adjoining walls upto 300mm height including cleaning the
surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats
25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand )
admixed with water proofing compound confirming to IS : 2645 and approved by Engineer-
in-charge over 20 mm thick layer of cement of 1:5 ( 1 cement : 5 coarse sand ) admixed
with water proofing compound confirming to IS : 2645 and approved by Engineer-in-
charge to required slope and treating similarly the
Sl. No. DOR-2023 DESCRIPTION UNIT QTY. MR RATE DSR AMT. NSOR Amount
adjoining walls upto 300mm height including rounding of junctions of walls and slabs. c)
After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm
of cement admixed with water proofing compound confirming to IS : 2645 and approved
by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar
1:4 (1 cement : 4 coarse sand ) admixed with water proofing compound confirming to IS :
2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved
quality in top layer and finally finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall
be flooded with water for a minimum period of two weeks for curing and for final test. All
above operations to be done in order and as directed and specified by the Engineer-in-
2.1 22.7.1 With average thickness of 120mm and minimum thickness at khurra as 65mm. SQM 308.00 1684.60 518,856.80
TOTAL (Carried Over to Summary of Civil Works) 530,072.92 0.00
J 22.00 6 Passenger lift
1 MR-4 Providing, fixing, and installing, 6 passenger Lift well size - 1550 mm (W) x 1550 mm (D),
No. of Stops 03, Openings- 03, Ground Floor to Second Floor 3.3 m ht. Clear Door
Opening- 700mm x 2000mm, Speed of Lift - 0.6 M/s, Automatic rescue device, etc., with
all necessary features, machine room Less, finish Side walls: Painted Pearl White, Rear
wall: Painted Saffron yellow, Front wall: Painted Pearl White, Handrail Round Bend
Handrail. Painted Traffic Black at Rear Wall, Ceiling & Lighting Integrated roof LS5 (RL5F)
Painted Pearl White [TYP_CAR_LIGHTING(LS5)]
Flooring 3 mm Pattern (PVC) Dark Grey Marble Pattern all complete as per specification
and instruction of Engineer in charge. Each 1.00 1,362,440.00
TOTAL (Carried Over to Summary of Civil Works) 0.00 1,362,440.00
ALL SUB-HEAD TOTAL 20,349,097.75 1,715,348.94
GRAND TOTAL 22,064,446.69
GRAND TOTAL 22,064,446.69
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
INTERIOR RENOVATION & FINISHING WORKS
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
A GROUND FLOOR
1 Supplying and laying true to line and level Double Charge Vitrified Tiles
of approved brand conforming to IS 15622: 2006 (Group B I a) and
tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for
tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in
20 mm thick sand cement mortar (1:4) bed prepared after application
of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick
cement slurry using cement @2.91Kg./sqm at the back side of the tiles
and laid over the mortar bed using 0.2 kg/sqm of White cement used
for joint filling with approved pigment as directed and removal of wax
coating of top surface of tiles with warm water and polishing the tiles
using soft and dry cloth upto mirror finish complete including the cost of
materials,Iabour and all other incidental charges complete true to the
manufacturer's specification and direction of Engineer-in-Charge.
1.01 Size not Iess than 800mm X 800 mm X 10.2 mm thick. Sqm. 155 2,532.00 392,460.00
1.02 Size not Iess than 600mm X 600 mm X 9.5 mm thick. Sqm. 280 1,484.00 415,520.00
2 Extra for epoxy grouting materials for filling joints including spacer-2
3 Providing and fixing 1st quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching
shade complete.
4 Providing and laying Vitrified tiles in floor in different sizes (thickness to
be specified by the manufacturer) with water absorption less than
conforming to IS: 15622, of approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement:
sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt Antiskid finish of size
Size of Tile 600 x 600 mm
5 Supplying, fitting & fixing granite slab 15mm to 18mm thick in floor,
lobby, stair, landing and treads etc. over 20mm(avg) thick base of
cement mortar (1:2) laid with white cement slurry @4.40 Kg per square
meter before placing of granite and jointed with white cement slurry @ Sqm. 335 3,025.00 1,013,375.00
2.0 Kg per square meter with necessary pigments and complete as per
direction of Engineer-in-Charge including cost of all materials, labours,
curing and roughening of concrete surface complete.
6 Cost of labour for prefinished and premoulded Nosing to treads of
steps, railing, window sill etc. of granite/stone.
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
7 Providing and fixing machine cut, mirror polished, Italian Marble stone
18 mm thick (Imported quality, such as Perlato, Bottichino, Crema,
Antique Beige, Dark Emperadore, Red Verona, Black Marquino etc.) in
dado/wall laid in required pattern in linear portion of the building all
complete as per architectural drawings with Italian Marble stone slab
laid over 15mm (average) thick base of cement mortar 1 : 2 (1 cement :
2 coarse sand) including making suitable arrangements to hold the
stones properly by brass / copper hooks applying white cement Sqm. 7 5,843.00 40,901.00
[email protected] kg/sq.m the back site of marble and pointing with cement
mortar (1:2) (1 cement : 2 marble dust) admixed with pigment to match
the marble shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge
including cost of materials, labours, scaffolding, staging, curing
8 Cost of labour for prefinished and premoulded window sill of Italian
9 Providing and fixing M.F. suspended ceiling made with 12.5 mm thick
Gypsum plaster board including G.I. perimeter channel of 0.55 mm
flush (having two flanges 20 mm and 30 mm respectively and web 27
mm ) along with perimeter of ceiling with G.I. intermediate channel of
0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling
angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I.
Cleat and steel expansion fastener ceiling section 0.55 mm thick of
size 51.50 mmx26mm fixed to the intermediate channels with the help
of connecting clip and in the direction of perpendicular to the Sqm. 200 1,159.00 231,800.00
intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered
board are to be fixed under ceiling section as above by machine
screws. The boards are to be joined and finished with jointing
compound, paper tape and application of top coat etc. as per the
direction of Engineer-in-Charge. (The rate includes of cost of all
materials including taxes, cost of accessories, fittings and fixtures,
scaffolding and labour charges etc. complete.)
10 Providing and fixing decorative false ceiling, framework made with 25 x
50 mm aluminium extruded section of wall thickness 1.5 mm fixed from
true ceiling with aluminium L cleat 25 x 25 mm. Framework to be done
at spacing not exceeding 600 mm c/c both ways. Paneling surface to
be done with 12 mm thick BWP grade solid plywood conforming to
IS:710, complete as per design and direction of Engineer-in-Charge. Sqm. 135 4,950.00 668,250.00
Plywood surface to be fixed and finished with PVC interlocking planks
8 mm thick made in honey-comb construction of width 200/250 mm.
The rate includes cost of material, accessories, labour, scaffolding and
all incidental charges.
11 Providing and fixing wall/column paneling, framework made with 25 x
50 mm aluminium extruded section of wall thickness 1.5 mm fixed on
masonary surface with aluminium L cleat 25 x 25 mm. Framework to be
done at spacing not exceeding 600 mm c/c both ways. Paneling Sqm. 30 4,850.00 145,500.00
surface to be done with 12 mm thick BWP grade solid plywood
conforming to IS:710, complete as per design and direction of
Engineer-in-Charge. The rate includes cost of material, labour,
scaffolding and all incidental charges.
12 Providing and fixing decorative lamination conforming to IS: 2046 :
1995 as per approved make, brand, finish and thickness with fitting,
fixing the same on plywood with recommended / approved adhesive
with proper clipping the sides for better attachment as per design and Sqm. 95 688.00 65,360.00
direction of Engineer-in-Charge. The rate includes the cost of material,
labour, scaffolding, adhesive and all incidental charges. Thickness of
laminate - 1 mm.
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
13 Providing and fixing door hardware/fittings from decorative range of
approved make Godrej/Ozone/Dorset for solid core flush door
consisting of 1 no. medium duty hydraulic door closure, single lever
mortise lock with pair of handles in SS matt finish, 1 no. of door stopper
in SS matt finish, 1 no. of tower bolt (6") and 4 nos. of hinges (4") in SS
304 grade, all complete.
14 Supplying, fitting and fixing solid flush type doors of commercial quality,
the timber frame consisting of top and bottom rails and side styles of
well seasoned timber 65 mm wide each and the entire frame fitted with
37.5 mm wide battens places both ways in order to make the door of
solid core and internal lipping with Garjan or similar wood veneers Sqm. 4 2,659.00 10,636.00
using phenol formaldehyde as glue etc. complete, including fitting,
fixing shutters in position, all complete as per direction of Engineer-in-
Charge. 32 mm thick shutters (single leaf) with vision aperture with
5mm thick glass pane with wooden beads.
15 Providing Wood work with Malayasian Sal in door and window frame
fitted and fixed in position complete including a protective coat of
painting at the contact surface of the frame exluding cost of concrete,
Iron Butt Hinges and M.S clamps.
16 Removing loose scales, blisters etc. from old painted surface and
thoroughly smoothening the surface to make the same suitable for Sqm. 350 39.00 13,650.00
receiving fresh coat of paint.
17 Rendering the surface of walls and ceiling with white cement based
wall putty of approved make and brand (1.5mm thick), complete to the Sqm. 1150 110.00 126,500.00
entire satisfaction of Engineer-in-Charge.
18 Providing and applying water based interior grade Acrylic Primer of
approved quality and brand, 2 coats on plastered or concrete surface
old or new surface to receive acrylic emulsion paint including scraping
and preparing the surface throughly, complete as per manufacturer's
specification and as per direction of Engineer-in-Charge.
19 Providing and applying Acrylic Emulsion Paint of approved make and
brand, 2 coats on walls and ceiling including sand papering in
intermediate coats including putty to the entire satisfaction of Engineer-
20 Providing and applying protective and decorative Textured exterior
high class matt finish paint, 2 coats of approved quality, composed of
special Tharmoplastic Resin containing fine crystalline additives derive
from Granite as per manufacturer's specification and as per direction of Sqm. 50 101.00 5,050.00
EIC to be applied over acrylic primer as required. The rate includes
cost of material, labour, scaffolding and all incidental charges but
excluding the cost of primer.
21 Priming one coat on steel or other metal surface with synthetic oil
bound primer of approved quality including smoothening surfaces by Sqm. 50 38.00 1,900.00
sand papering etc.
22 Providing and painting with best quality synthetic enamel paint of
approved make and brand, 2 coats on steel or other metal surface
including smoothening surface by sand papering etc. including using of
approved putty etc. on the surface, if necessary.
23 Supply and installation of Window Blinds with screen fabric, including
the cost of fabric, roller, accessories all complete.
24 Providing and fixing full glazed reamless sliding door with 12 mm clear
toughened glass conforming to IS: 2553-1992 (Part-II) operated on
automatic sliding mechanism of Godrej/Dorma/Hafele, all complete as Nos. 1 350,000.00 350,000.00
per direction and approval of Engineer-in-Charge. Door size - 2200 mm
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
25 Providing and fixing full glazed reamless door with 12 mm thick clear
toughened glass conforming to IS: 2553-1992 (Part-II) mounted on
heavy duty hydraulic action floor spring with top and bottom pivot
assembly, fitted with SS lock and pair of SS handles (600 mm x 32
mm), all complete as per direction and approval of Engineer-in-Charge.
Double leafs - 1800 mm x 2100 mm (h).
26 Providing, fabricating and fixing SS Railing 950 mm high (above the
finished floor) with 50 mm dia. x 2 mm thick SS 304 grade pipe as top
hand rail main runner and 50 mm x 50 mm x 2 mm thick bottom runner
housing 12 mm thick clear toughened glass with necessary supports,
plates, anchor fasteners, supports as per design and direction of
Engineer-in-Charge.
27 Providing, fabricating and fixing in position SS Hand Rail along
walls with main bar 40 mm dia. x 2 mm thick SS 304 grade pipe with all
necessary fittings as the main runner joined to 25 mm dia. SS pipe and
vertical bracket 2 mm thick held on to walls by means of
fasteners, base plates @ every 1050 mm c/c complete as per design
and direction of Engineer-in-Charge.
28 Providing, fabricating and fixing MS Railing 950 mm high (above the
finished floor) with 50 mm dia. x 2 mm thick MS pipes as main runner
and 19 mm dia. x 2 mm thick pipe at 4 levels along the running length
of the staircase and vertical supports in 40 mm x 2 mm thick pipes in Rmt. 0 7,460.00 -
approved profilie @ 1350 mm c/c, with necessary supports, plates,
anchor fasteners, supports as per design and direction of Engineer-in-
29 Providing and fixing sandwiched acrylic panel with 2 layers of acrylic
sheets of imported quality, first layer with 4 mm thick acrylic sheet and
6 mm thick acrylic sheet on top with bevelled edges on all sides. Panel Sqm. 10 4,850.00 48,500.00
to be mounted on wall/partition with SS studs (25 mm dia. x 25 mm), all
complete as per design.
30 Supplying FRP Planter Box, size - 30" x 10" x 10". Nos. 10 4,480.00 44,800.00
31 Providing and fixing mirror of extra clear quality, 6 mm thick fixed on
existing wall/partition with SS studs (25 mm dia. x 25 mm). Mirror
edges on all sides to be polished as per direction of Engineer-in-
SUB-TOTAL A 5,137,299.18
1 Supplying and laying true to line and level Double Charge Vitrified Tiles
of approved brand conforming to IS 15622: 2006 (Group B I a) and
tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for
tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. set in
20 mm thick sand cement mortar (1:4) bed prepared after application
of slurry using 1.75Kg of cement per Sqm over the base and 2mm thick
cement slurry using cement @2.91Kg./sqm at the back side of the tiles
and laid over the mortar bed using 0.2 kg/sqm of White cement used
for joint filling with approved pigment as directed and removal of wax
coating of top surface of tiles with warm water and polishing the tiles
using soft and dry cloth upto mirror finish complete including the cost of
materials,Iabour and all other incidental charges complete true to the
manufacturer's specification and direction of Engineer-in-Charge.
1.01 Size not Iess than 800mm X 800 mm X 10.2 mm thick. Sqm. 500 2,532.00 1,266,000.00
1.02 Size not Iess than 600mm X 600 mm X 9.5 mm thick. Sqm. 620 1,484.00 920,080.00
2 Extra for epoxy grouting materials for filling joints including spacer-2
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
3 Providing and fixing 1st quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1 :3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching
shade complete.
4 Providing and laying Vitrified tiles in floor in different sizes (thickness to
be specified by the manufacturer) with water absorption less than
conforming to IS: 15622, of approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement:
sand) jointing with grey cement slurry @3.3 kg/sqm including grouting
the joints with white cement and matching pigments etc. The tiles must
with the zero chipping diamond cutter only . Laying of tiles will be done
with the notch trowel, plier, wedge, clips of required thickness, leveling
system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt Antiskid finish of size
Size of Tile 600 x 600 mm
5 Providing and fixing machine cut, mirror polished, Italian Marble stone
18 mm thick (Imported quality, such as Perlato, Bottichino, Crema,
Antique Beige, Dark Emperadore, Red Verona, Black Marquino etc.) in
dado/wall laid in required pattern in linear portion of the building all
complete as per architectural drawings with Italian Marble stone slab
laid over 15mm (average) thick base of cement mortar 1 : 2 (1 cement :
2 coarse sand) including making suitable arrangements to hold the
stones properly by brass / copper hooks applying white cement Sqm. 7 5,843.00 40,901.00
[email protected] kg/sq.m the back site of marble and pointing with cement
mortar (1:2) (1 cement : 2 marble dust) admixed with pigment to match
the marble shade including rubbing, curing and polishing etc. all
complete as specified and as directed by the Engineer-in-Charge
including cost of materials, labours, scaffolding, staging, curing
6 Cost of labour for prefinished and premoulded window sill of Italian
7 Providing and fixing M.F. suspended ceiling made with 12.5 mm thick
Gypsum plaster board including G.I. perimeter channel of 0.55 mm
flush (having two flanges 20 mm and 30 mm respectively and web 27
mm ) along with perimeter of ceiling with G.I. intermediate channel of
0.9 mm thick size 45 mmx15mm placed at 750 mm c/c with G.I. ceiling
angle of size 25 mmx10mmx0.55 mm thick fixed to the ceiling with G.I.
Cleat and steel expansion fastener ceiling section 0.55 mm thick of
size 51.50 mmx26mm fixed to the intermediate channels with the help
of connecting clip and in the direction of perpendicular to the Sqm. 1050 1,159.00 1,216,950.00
intermediate channel of 300 mm c/c 12.5 mm thick Gypsum plastered
board are to be fixed under ceiling section as above by machine
screws. The boards are to be joined and finished with jointing
compound, paper tape and application of top coat etc. as per the
direction of Engineer-in-Charge. (The rate includes of cost of all
materials including taxes, cost of accessories, fittings and fixtures,
scaffolding and labour charges etc. complete.)
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
8 Providing and fixing of false ceiling with powder coated exposed G.I.
grid suspension system(E-GridU-1520 or equivalent load carrying
capacity with mid span deflection not exceeding 1/360 span with
hanger spacing of 1200mmc/c) consisting of main runner 3600 mm
long, cross Tee 1200 mm/600 mm long and wall angle. The wall angle
shall be fixed on PVC dash fasteners on the perimeter of the wall by
steel screws with distance 300 mm c/c. The main runners to be placed
@1200 mm. The cross Tee 1200 mm will be inserted in the pre-cut
slots of main runner at a regular interval of 600 mm to form a modular
grid of 1200 mm X 600 mm. Additional cross Tees of 600 mm shall be Sqm. 145 1,357.00 196,765.00
placed perpendicular to the cross Tee 1200 mm long to finally form a
grid of 600 mm X 600mm. Grid of module size 600 mm X 600 mm shall
be supported by 6 mm dia G.I. wire from purlins/soffit. 15 mm thick OW
Acoustic Board (Mineral Fiber Acoustic Ceiling Tiles of approved
pattern and size 595 mm X 595 mm with NRC value > 0.65 should be
placed in the Grid module to form a False Ceiling. All complete as per
the drawing & directions of Engineer-in-Charge.
9 Providing and fixing wall/column paneling, framework made with 25 x
50 mm aluminium extruded section of wall thickness 1.5 mm fixed on
masonary surface with aluminium L cleat 25 x 25 mm. Framework to be
done at spacing not exceeding 600 mm c/c both ways. Paneling Sqm. 250 4,850.00 1,212,500.00
surface to be done with 12 mm thick BWP grade solid plywood
conforming to IS:710, complete as per design and direction of
Engineer-in-Charge. The rate includes cost of material, labour,
scaffolding and all incidental charges.
10 Providing and fixing decorative lamination conforming to IS: 2046 :
1995 as per approved make, brand, finish and thickness with fitting,
fixing the same on plywood with recommended / approved adhesive
with proper clipping the sides for better attachment as per design and Sqm. 401 688.00 275,888.00
direction of Engineer-in-Charge. The rate includes the cost of material,
labour, scaffolding, adhesive and all incidental charges. Thickness of
laminate - 1 mm.
11 Providing and fixing Grooved Acoustical Slats Wood based MDF
panels with linear perforations. The melamine laminate in size 2440mm
x 128mm x 16mm type 28/2 i.e. having 28mm strips and 2mm groove,
tongue and groove edges for seamless mounting having density of
600kg/m3. The back of the panels are perforated with 8-10mm Sqm. 110 4,950.00 544,500.00
diameter circular holes with black acoustic fleece covering for providing
sound absorption. Panel is wooden slat will be backed with polyester
fibre 1000 gsm. Wooden slat will be fixed on 19 x 50mm ply
strip/framework.
12 Providing and fixing door hardware/fittings from decorative range of
approved make Godrej/Ozone/Dorset for solid core flush door
consisting of 1 no. medium duty hydraulic door closure, single lever
mortise lock with pair of handles in SS matt finish, 1 no. of door stopper
in SS matt finish, 1 no. of tower bolt (6") and 4 nos. of hinges (4") in SS
304 grade, all complete.
13 Supplying, fitting and fixing solid flush type doors of commercial quality,
the timber frame consisting of top and bottom rails and side styles of
well seasoned timber 65 mm wide each and the entire frame fitted with
37.5 mm wide battens places both ways in order to make the door of
solid core and internal lipping with Garjan or similar wood veneers Sqm. 30 2,659.00 79,770.00
using phenol formaldehyde as glue etc. complete, including fitting,
fixing shutters in position, all complete as per direction of Engineer-in-
Charge. 32 mm thick shutters (single leaf) with vision aperture with
5mm thick glass pane with wooden beads.
14 Providing Wood work with Malayasian Sal in door and window frame
fitted and fixed in position complete including a protective coat of
painting at the contact surface of the frame exluding cost of concrete,
Iron Butt Hinges and M.S clamps.
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
15 Removing loose scales, blisters etc. from old painted surface and
thoroughly smoothening the surface to make the same suitable for Sqm. 750 39.00 29,250.00
receiving fresh coat of paint.
16 Rendering the surface of walls and ceiling with white cement based
wall putty of approved make and brand (1.5mm thick), complete to the Sqm. 2600 110.00 286,000.00
entire satisfaction of Engineer-in-Charge.
17 Providing and applying water based interior grade Acrylic Primer of
approved quality and brand, 2 coats on plastered or concrete surface
old or new surface to receive acrylic emulsion paint including scraping
and preparing the surface throughly, complete as per manufacturer's
specification and as per direction of Engineer-in-Charge.
18 Providing and applying Acrylic Emulsion Paint of approved make and
brand, 2 coats on walls and ceiling including sand papering in
intermediate coats including putty to the entire satisfaction of Engineer-
19 Providing and applying protective and decorative Textured exterior
high class matt finish paint, 2 coats of approved quality, composed of
special Tharmoplastic Resin containing fine crystalline additives derive
from Granite as per manufacturer's specification and as per direction of Sqm. 120 101.00 12,120.00
EIC to be applied over acrylic primer as required. The rate includes
cost of material, labour, scaffolding and all incidental charges but
excluding the cost of primer.
20 Priming one coat on steel or other metal surface with synthetic oil
bound primer of approved quality including smoothening surfaces by Sqm. 110 38.00 4,180.00
sand papering etc.
21 Providing and painting with best quality synthetic enamel paint of
approved make and brand, 2 coats on steel or other metal surface
including smoothening surface by sand papering etc. including using of
approved putty etc. on the surface, if necessary.
22 Supply and installation of Window Blinds with black-out fabric,
including the cost of fabric, roller, accessories all complete.
23 Supply and installation of Motorized Fabric Curtain on tracks including
the cost of fabric, accessories and motor of make Somfy/equivalent
with remote control. Base rate of fabric- Rs. 1000 per rmt.
24 Providing and fixing sandwiched acrylic panel with 2 layers of acrylic
sheets of imported quality, first layer with 4 mm thick acrylic sheet and
6 mm thick acrylic sheet on top with bevelled edges on all sides. Panel Sqm. 5 4,850.00 24,250.00
to be mounted on wall/partition with SS studs (25 mm dia. x 25 mm), all
complete as per design.
25 Supplying FRP Planter Box, size - 36" x 12" x 16". Nos. 2 8,900.00 17,800.00
26 Providing and fixing mirror of extra clear quality, 6 mm thick fixed on
existing wall/partition with SS studs (25 mm dia. x 25 mm). Mirror
edges on all sides to be polished as per direction of Engineer-in-
27 Supplying, fitting and fixing DGU GLASS on façade using double
insulated glass unit with exterior face of SAINT GOBAIN/AIS make
high performance heat reflective toughened glass of 6 mm thick (with
light transmission VLT 34%, Solar factor SF 22 & u Value 1.7w/m2/0 K)
& interior glass in 6 mm clear non-heat strengthened & air gap of 12
mm to be installed on curtain wall mullion & transom system using Sqm. 65 10,385.00 675,025.00
extruded aluminium section make ALOM. The section should be fixed
section of 50 x 50 mm having thickness not less than 2 mm powder
coated in 40 microns in desired colour of EPDM gaskets, silicon
sealants. (Contractor to submit manufacture's test certificate)
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
28 Providing and fixing storage cabinets, structures made with 19 mm
thick BWP grade solid plywood conforming to IS:710. Back surfaces
fixed to the wall/partition to be made with 6 mm thick BWP grade
plywood. Shutters and intermediate shelves to be made with 19 mm
thick BWP grade solid plywood conforming to IS:710. All inside
surfaces to be finished with 0.7 mm thick balancer laminate and
exposed outside surfaces to be finished with 1 mm thick decorative
laminate conforming to IS: 2046 : 1995 as per approved make, brand, Sqm. 7 11,750.00 82,250.00
finish on plywood with recommended / approved adhesive. Plywood
edges to be finished with 2 mm thick PVC edge banding matching the
lamination shade. The rate includes the cost of SS hinges, handles,
locks accessories and adhesives, all complete as per design and
direction of Engineer-in-Charge. Depth of storage - 450 mm. (For
measurement purpose the face area : length x height is to be
29 Providing and fixing pantry storage cabinet, structures made with 19
mm thick BWP grade solid plywood conforming to IS:710. Back
surfaces fixed to the wall/partition to be made with 6 mm thick BWP
grade plywood. Shutters and intermediate shelves to be made with 19
mm thick BWP grade solid plywood conforming to IS:710. All inside
surfaces to be finished with 0.7 mm thick balancer laminate and
exposed outside surfaces to be finished with 1 mm thick decorative
laminate conforming to IS: 2046 : 1995 as per approved make, brand,
finish on plywood with recommended / approved adhesive. Plywood Sqm. 5 15,600.00 78,000.00
edges to be finished with 2 mm thick PVC edge banding matching the
lamination shade. Top of the storage to be provided with 18 mm thick
granite with 100 mm high splash back. Granite edge to be moulded
finished. The rate includes the cost of SS hinges, handles, locks
accessories and adhesives, all complete as per design and direction of
Engineer-in-Charge. Depth of counter/storage - 600 mm. (For
measurement purpose the face area : length x height is to be
30 Providing and fixing overhead storage cabinets, structures made with
19 mm thick BWP grade solid plywood conforming to IS:710. Back
surfaces fixed to the wall/partition to be made with 6 mm thick BWP
grade plywood. Shutters and intermediate shelves to be made with 19
mm thick BWP grade solid plywood conforming to IS:710. All inside
surfaces to be finished with 0.7 mm thick balancer laminate and
exposed outside surfaces to be finished with 1 mm thick decorative
laminate conforming to IS: 2046 : 1995 as per approved make, brand, Sqm. 3 11,500.00 34,500.00
finish on plywood with recommended / approved adhesive. Plywood
edges to be finished with 2 mm thick PVC edge banding matching the
lamination shade. The rate includes the cost of SS hinges, handles,
locks accessories and adhesives, all complete as per design and
direction of Engineer-in-Charge. Depth of storage - 450 mm. (For
measurement purpose the face area : length x height is to be
SUB-TOTAL B 8,715,436.95
TOTAL BASIC - A + B 13,852,736.13
TOTAL AMOUNT 13,852,736.13
TOTAL AMOUNT 13,852,736.13
Construction of DIC Office Building and Modification / Renovation of Existing Office Building
at SAIL-DSP, Durgapur
DSR Amount NON DSR
S.H. No. DESCRIPTION OF SUB-HEAD
(Rs) Amount (Rs)
SUB HEAD - INTERNAL PLUMBING WORKS
1 SANITARY FITTINGS & FIXTURES : 0.00 1133608.30
3 RAIN WATER WORK : 39420.00 0.00
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
SANITARY FITTINGS & FIXTURES
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
A GROUND FLOOR
Supply & Installation of --
Wash Basin- wall hung with half pedestal including flange, CP
waste, PVC waste, extension pipe & hanging accessories.
Cat. No: S2040163H
Cat. No: F1018101
Cat. No: F8060101
Wall hung WC with Dual Flush Cistern & soft close seat cover
including connecting pipe, flange, extension pipe, hanging
accessories etc.
Cat. No: S1043147
Cat. No: F8060101
6 CP Angular Stop Cock Nos. 17 3,658.00 62,186.00
CP Tissue Paper Holder with Flap
Cera Hera F5007110
9 Tissue Paper Dispenser Nos. 2 9,150.90 18,301.80
B 1ST FLOOR - -
Supply & Installation of -- -
DIC CHAMBER - -
Wash Basin- Granite counter top wash basin including flange,
CP waste, PVC waste, extension pipe & accessories.
Cat. No: S2020161
Shower Unit overhead rain shower Cat. No:
3 Diverter for Shower unit-Single lelver concelead diverter Nos. 1 8,968.00 8,968.00
Wash Basin- wall hung with half pedestal including flange, CP
waste, PVC waste, extension pipe & hanging accessories.
Cat. No: S2040163H
Cat. No: F1018101
Cat. No: F8060101
Wall hung WC with Dual Flush Cistern & soft close seat cover
including connecting pipe, flange, extension pipe, hanging
accessories etc.
Cat. No: S1043147
Cat. No: F8060101
9 CP Angular Stop Cock Nos. 31 3,658.00 113,398.00
CP Tissue Paper Holder with Flap
Cera Hera F5007110
Urinal with Sensor including PVC spreader, doom waste,
11 hanging accessories etc. Cat. No: Nos. 6 7,670.00 46,020.00
13 Tissue Paper Dispenser Nos. 4 9,150.90 36,603.60
Modular Urinal Partition 400 x 900mm in compact laminate
including all accessories.
SS Sink with drain board including flange, CP waste, PVC waste
& extension pipe.
GRAND TOTAL AMOUNT 1,133,608.30
GRAND TOTAL AMOUNT 1,133,608.30
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
INTERNAL PLUMBING WORKS
SI.No. DSR-2023/ Description of Item UNIT QUANTITY DSR-2023 MR RATE DSR AMOUNT MR
NON DSR RATE AMOUNT
SUB HEAD - INTERNAL PLUMBING WORKS
B) WATER SUPPLY
2.01 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, i/c fixing the
pipe with clamps at 1.00 m spacing. This includes jointing of
pipes & fittings with one step CPVC solvent cement and the cost
of cutting chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good
2.02 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)
pipes, having thermal stability for hot & cold water supply,
including all CPVC plain & brass threaded fittings, including
fixing the pipe with clamps at 1.00 m spacing. This includes
jointing of pipes & fittings with one step CPVC solvent cement
and testing of joints complete as per direction of Engineer in
Internal work - Exposed on wall
2.03 MR Supplying, fixing, testing and commissioning of butterfly valve
of PN 1.6 rating with bronze/gunmetal seat duly ISI marked
complete with nuts, bolts, washers, gaskets conforming to IS
13095 of following sizes as required :
2.04 18.62 Providing and fixing PTMT Ball cock of approved quality, colour
and make complete with Epoxy coated aluminium rod with L.P./
H.P.H.D. plastic ball.
b) 18.62.4 40 mm nominal bore, 206mm long, weighing not less than 690 Each 1 737.20 737.20 0.00
c) 18.62.5 50 mm nominal bore, 242mm long, weighing not less than 1240 Each 1 1375.95 1375.00 0.00
2.05 18.48 Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, ISI : 12701 marked, with cover and suitable
locking arrangement and making necessary holes for inlet,
outlet and overflow pipes but without fittings and the base
support for tank. per litre 10000 11.00 110000.00 0.00
2.06 NON DSR Providing & fixing Auto Air vent for cold water supply risers,
suitable for pressure not less than 15 Kg/Sq.cm.
TOTAL FOR WATER SUPPLY 324163.00 1806.00
D) RAIN WATER WORK
4.01 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
4.02 12.42 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A including jointing with seal ring
conforming to IS : 5382 leaving 10 mm gap for thermal
a) 12.42.2 Single Push fit coupler
b) 12.42.3 Single Tee with door
c) 12.42.5 Bend 87.5 Deg
d) 12.42.6 Shoe (Plain)
SI.No. DSR-2023/ Description of Item UNIT QUANTITY DSR-2023 MR RATE DSR AMOUNT MR
NON DSR RATE AMOUNT
4.03 12.44 Providing and fixing to the inlet mouth of rain water pipe cast Each 6 54.70 328.20 0.00
iron grating 15 cm diameter and weighing not less than 440
4.04 12.43 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in cement
mortar 1:4 (1 cement : 4 coarse sand) and making good the wall
4.05 12.22 Making khurras 45x45 cm with average minimum thickness of 5 Each 6 298.25 1789.50 0.00
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m
x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding
the edges and making and finishing the outlet complete.
TOTAL FOR RAIN WATER WORK 39420.00 0.00
Construction of DIC Office Building and Modification / Renovation of Existing Office Building
at SAIL-DSP, Durgapur
Electrical Works
Sl. No. Descriptions Amount
1 TOTAL OF SCHEDULE ITEMS-( DSR-2022) (PART-A) 2,814,161.00
2 NON SCHEDULE ITEM
i) TOTAL OF NON SCHEDULE ITEMS (PART-B)(ELECTRICAL) 4,422,564.00
ii) TOTAL OF VARIABLE REFRIGERANT FLOW SYSTEM (PART-C) 3,630,421.00
iii) TOTAL SURVEILLANCE CCTV SYSTEM (PART-D) 486,642.00
iv) TOTAL TELEPHONE SOLUTION (PART-E) 266,938.00
v) TOTAL OF DATA NET WORKING SYSTEM (ACTIVE & PASSIVE COMPONENTS) 1,949,969.00
vi) TOTAL OF METAL RACE WAY (PART G) 700,896.00
TOTAL OF NON SCHEDULE ITEMS (PART B+C+D+E+F) 14,271,591.00
TOTAL OF SCHEDULE ITEMS & NON SCHEDULE ITEMS (PART 14,271,591.00
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
Electrical Works
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
A. DSR- 2022 SCHEDULE ITEMS (DSR-2022) (PART-A)
1 D.S.R 1.10 Point Wiring in Medium Class PVC Conduit, with Modular type
Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell
point with 1.5 sq.mm FR PVC insulated copper conductor single
core cable in surface/recessed Medium Class PVC conduit, with
modular type switch, modular plate, suitable size of GI box and
earthing the point with 1.5 sq.mm. FR PVC insulated copper
conductor single core cable etc as required. Make FRLS PVC CU
Wire:: Havells, Finolex Lap, KEI. (Make of Modular switch
Sockets:- Havells (ATHENA), L&T ENGLAZE), Legrand (LYNCUS)
, Anchor(WOODS), Schneider-(OPEL) PVC Conduit:- BEC AKG
2 D.S.R 1.11 Wiring for twin control light point with 1.5 sq.mm FR PVC Point 8 1,562.00 12,496.00
insulated copper conductor single core cable in surface/recessed
Medium Class PVC conduit, 2 way modular switch, modular plate,
suitable size of GI box earthing the point with 1.5 Sq. mm FR
PVC insulated copper conductor single core cable etc as
required. FRLS CU. Wire Make:- Havells, Finolex, Lap, KEI. (Make
of Modular switch Sockets:- Havells (New Murano), Legrand
(Myrius)) , ABB (Millenia), Schneider-(Zencello)
3 D.S.R 1.12 Wiring for light/power plug with 2x4 Sq.mm FR PVC insulated Mtr. 500 334.00 167,000.00
copper conductor single core cable in surface/recessed Medium
Class PVC conduit along with 1 No. 4 Sq.mm FR PVC insulated
copper conductor single core cable for loop earthing etc. as
required. Make:- Havells, Polycab, Finolex. Lap
4 D.S.R 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the
following sizes of FR PVC insulated copper condcutor, single core
cable in surface/ recessed Medium Class PVC conduit as
required. Make:- Havells, KEI, Finolex Lap. PVC Conduit:- BEC
5 D.S.R 1.18 Telephone Wiring in Existing Conduit:- Supplying and
drawing, following pair, 0.5 sq.mm FR PVC insulated copper
conductor, unarmoured telephone cable in the existing surface /
recessed steel / PVC conduit as required.
6 D.S.R 1.21 S/F PVC Conduit: Supplying and fixing of following sizes of Med
Class PVP conduit along with the accessories in surface / recess
& cutting the wall and making good the same in case of recessed
conduit as required for TV and TEL out lets.
7 D.S.R. 1.22 Supply and fixing of Metal box following size (nominal Size) on
surface or recess with suitable size of phenolic laminated sheet
cover in front including painting etc as required. (to use as gang
1.22.1 75mmx75mmx60mm deep. Each 4 178.00 712.00
8 D.S.R. Supplying and fixing of following switch/ socket on the existing
1.24 modular plate & switch box including connections but excluding
modular plate etc. as reqd.
1.24.4 3 pin 5/6A socket outlet Each 80 122.00 9,760.00
1.24.5 6 pin 15/16 amp socket outlet Each 18 197.00 3,546.00
1.24.6 Telephone socket outlet Each 30 148.00 4,440.00
1.24.7 TV antenna socket outlet Each 1 148.00 148.00
9 D.S.R. Supplying and fixing Stepped type electronic fan regulator on Each 15 369.00 5,535.00
1.25 the existing modular plate & switch box including connections but
excluding modular plate etc. as reqd.
10 D.S.R. Supplying and fixing modular blanking plate on the existing Each 20 40.00 800.00
1.26 modular plate & switch box excluding modular plate as required.
11 D.S.R. Supply and fixing of following size/ modules, GI box along with
1.27 modular base & cover plate for modular switch/ regulator in
recess, including connection as required.
1.27.4 6 module (200mmx 75mm) (for 2 nos. 6A Sockets & 2no. 6A Each 50 402.00 20,100.00
12 D.S.R. Supplying and fixing suitable size GI box with modular plate and Each 20 477.00 9,540.00
1.31 cover in front on surface or in recess including providing and fixing
3 pin 5/6 Amp modular socket outlet and 5/6 A modular type
switch, connections painting etc. as reqd. (for Light plug point).
13 D.S.R. Supplying and fixing suitable size GI box with modular plate and Each 25 586.00 14,650.00
1.32 cover in front on surface or in recess including providing and fixing
6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A
modular type switch, connections painting etc. as reqd.
14 D.S.R. Supplying & fixing of 3 pin, 5 amp Ceiling rose on the existing Each 250 87.00 21,750.00
1.33 junction box/ wooden block including connection as required.
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
15 D.S.R. Supplying and fixing call bell/buzzer suitable for single phase, 230 Each 7 99.00 693.00
1.38 V, complete as required.
16 D.S.R. Installation, testing and commissioning of Ceiling Fans, including Each 15 213.00 3,195.00
1.44 wiring the down rods of standard length (up to 30cm) with 1.5 Sq
mm FRLS PVC insulated copper conductor, single core cable and
earthing etc. as required.
17 D.S.R. Installation of exhaust fan in the existing opening, including
1.50 making good the damage, connection, testing, commissioning etc.
18 D.S.R 2.3 Supplying and fixing following way single pole & neutral, sheet
steel, MCCB distribution board, 240V, on surface/ recces ,
complete with tinned copper bus bar, neutral bar, earth bar, din
bar interconnections, powder painted including earthing etc. as
required (But without MCCB/RCCB/Isolator) Make:-SIEMENS-
Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU
2.3.2 8 way Double door Each 1 2,573.00 2,573.00
2.3.3 12 way Double door Each 1 2,315.00 2,315.00
19 D.S.R 2.4 Supplying and fixing following way, horizontal type thee pole &
neutral, sheet steel, MCCB distribution board, 415V, on surface/
recces , complete with tinned copper bus bar, neutral bar, earth
bar, din bar interconnections, powder painted including earthing
etc. as required (But without MCCB/RCCB/Isolator) Make:-
SIEMENS-Bitaguard, LEGRAND-Ekinox³-, SCHNEIDER-ACTI-9,
20 D.S.R 2.5 Supplying and fixing of following ways surface/ recess mounting,
vartical type, 415 V, TPN MCCB/MCB distribution board of sheet
steel, dust protected, duly powder painted, inclusive of 200 A
tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCBs( but without MCCBs and incomer) as required.
(Note : Vertical type MCB TPDB is normally used where 3 phase
outlets are required.) Make:-SIEMENS-Bitaguard, LEGRAND-
Ekinox³-, SCHNEIDER-ACTI-9, L&T-AU
21 D.S.R 2.10 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA,
C curve Miniature Circuit Breaker suitable for inductive loads of
following poles in the existing MCB DB complete with connections,
testing and commissioning etc. as required. (Make:-LEGRAND-
DX³/SCHNEIDER- ACTI-9/SIEMENS- BETA GUARD/ L&T- AU
2.10.5 Triple Pole and neutral Each 5 1,228.00 6,140.00
22 D.S.R 2.14 Supplying & fixing following rating double pole (Single Phase &
Neutral) 240 V, Resudual Curren Circuit Breaker (RCCB) , having
a sensitivity current uo to 300mA in the existing MCB DB
complete with connections, testing and commissioning etc. as
required. Make:-LEGRAND- DX³/SCHNEIDER- ACTI-9/SIEMENS-
BETA GUARD/ L&T- AU VERSION.
23 D.S.R 2.18 Supplying and fixing of 20A 240V, SPN Industrial Type soclket out Each 20 1,621.00 32,420.00
let with 2 pole and earth, metal cenclosed plug top along with 20A
"C" Series SP MCB, in sheet steel enclosure, on surface or in
recess, with chained metal cover for the socket out let and
complete with connections, testing and commissioning etc. as
required. Make:- Legrand, L&T, Siemens, Schneider.
24 D.S.R 2.21 Providing & fixing of M.V. danger notice plate of 200 mm x 150 Each 2 269.00 538.00
mm, made of mild steel, at least 2 mm thick, and vitreous
enamelled white on both sides, and with inscription in single red
colour on front side as required.
25 D.S.R. EARTHING SYSTEM
i) 5.2 Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including Each 3 6,855.00 21,472.00
accessories, and providing massonry enclosure with cover plate
having locking arragement and watering pipe etc. with
charcoal/cock and salt as required. (For LT Panels)
ii) 5.6 Earthing with copper Earth plate 600mm x 600mm x 6mm thick Each 4 13,838.00 55,352.00
including accessories, and providing masonary enclosure with
cover plate having locking arrangement and watering pipe of 2.7
Meter long etc. (with charcoal and salt as required). (for UPS &
iii) D.S.R. Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below Mtr 10 144.00 1,440.00
5.9 ground/surface as strip earth electrode, including connection/
terminating with nut, bolt, spring, washer etc. as required (Jointing
shall be done by overlapping and with 2 sets of G.I. nut bolt &
spring washer spaced at 50 mm)
iv) D.S.R. Providing and fixing 4mm dia copper wire on surface or in recess Mtr 50 155.00 7,750.00
5.17 in 25 mm medium class PVC PIPE for loop earthing as required.
26 LIGHTNING CONDUCTOR
i) D.S.R. Providing and fixing of Lightning Conductor finial, made of 25 mm Each 6 518.00 3,108.00
6.2 dia 300mm ling, copper tube, having single prong at top, with 85
mm dia 3 mm thick copper base plate including holes etc.
complete as required.
ii) D.S.R. Providing and fixing G.I. Tape 20mmx3mm thick on parapat or Mtr 250 126.00 31,500.00
6.7 surface of the wall for lightning conductor complete as required.
(for Horizontal Run).
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
iii) D.S.R. Providing and fixing G.I. Tape 20mmx3mm thick on parapat or Mtr 80 197.00 15,760.00
6.8 surface of the wall for lightning conductor complete as required.
(for Vertical Run).
iv) D.S.R. Earthing with G.I. Earth Pipe 4.5 Meter long , 40mm dia including Each 6 6,855.00 41,130.00
5.2 accessories, and providing massonry enclosure with cover plate
having locking arragement and watering pipe etc. with
charcoal/cock and salt as required.
v) D.S.R. Supplying and laying 25 mm X 5 mm GI strip at 0.50 meter below Mtrs. 30 144.00 4,320.00
5.9 ground/surface as strip earth electrode, including connection/
terminating with nut, bolt, spring, washer etc. as required (Jointing
shall be done by overlapping and with 2 sets of G.I. nut bolt &
spring washer spaced at 50 mm).
27 D.S.R. Laying of I no. PVC insulated and and PVC sheathed /XLPE
7.1 power cable of 1.1 KV grade of following size direct in ground
including excavation snad cushioning, protective covering and
refilling the trench etc as required.
i) 7.1.4 Above 185 Sq. mm. and up to 400 Sq. mm Mtr 225 474.00 106,650.00
ii) D.S.R. Laying and fixing one no. PVC insulated and PVC sheathed /XLPE
7.7 power cable of 1.1 KV gade of following size on wall surface as
iii) 7.7.1. Up to 35 Sq mm (Clamped with 1 mm thick shadle) Mtr 65 55.00 3,575.00
iv) 7.7.2. Above 35 Sq mm and up to 95 Sq mm (Clamped with 25X3 mm Mtr 30 130.00 3,900.00
28 DSR 9.1 1.1 KV Cable End Termination:-Supplying and making indoor
cable end termination with brass double compression gland and
aluminium lugs for following size of PVC insulated XLPE Al. Ar.
Cable of 1.1 KV grade as required.
29 DSR 14.13 Providing, laying and fixing following dia G.I. pipe (medium class)
in ground complete with G.I. fittings including trenching (75 cm
deep)and re-filling etc. as required.
TOTAL OF SCHEDULE ITEMS-(DSR-2022) (PART-A) 2,814,161.00
NON SCHEDULE ITEMS (PART-B) (ELECTRICAL)
1 N.S. 10 KVA on Line 3 ph in and 3 ph out UPS
A) Supply, fitting, fixing, commissioning and testing 10 KVA True
Online Double Conversion UPS Stand alone, 3 phase in and 3
phase out with IGBT based rectifireand inverter along with n]inbuilt
isolation Transformer with 30 min. back up time Make UPS:-
Numeric (Legrand), APC (Schneider), Vertive(Emersion)
Supply, fitting, fixing and testing of 1 no. 10 KVA in parallel
redundant mode with SMF back-up batteries suitable for 30
minutes configuration with :- 415V, 3ph input & 3 ph output ON-
LINE UPS system backup protection for 30 minutes and all
standard accessories as required. The UPS will have in built
protection for ground fault, DC reverse polarity, DC over voltage
and current limitation, AC short circuit, AC over Voltage and
current limitation. The UPS technology should consists of high
double-conversion efficiency IGBT Based rectifier on line type
UPS.The details are as follows:-
Configuration of UPS :-
3 Phase input & 3 Phase output
The above mentioned on-line UPS must have following features
1) Upgradeability :- Suitable for paralleling up to 3 nos. of 10 KVA
UPS, and Should be upgradable to work as parallel redundant
UPS in load sharing mode.
2) Intelligent LCD display with event logging facility.
3) Double conversion.
4) Built in paralleling kit.
5) IGBT technology for Rectifier and Inverter.
6) Split Static, Manual & Maintenance Bypass.
7) Input power factor correction less than 0.95.
8) Input harmonic distortion less than 5% at 50% load. with the
application of IGBT(Insulated Gate By polar Transistor) based
rectifier, but 6/12 pulse is not applicable.
9) Software communication :- RJ-45 port to communicate with
BMS and Should be SNMP (Simple Network Management
protocol) compatibility.
10) Phase reverse sequence operation
11) Automatic static bypass
12) Maintenance Bypass.
13) Technology : Micro processor based controls, true online,
double conversion type, should have cold start facility.
14) Overall minimum Efficiency :>93.8 %
15) Isolation ;- Built inl isolation transformer at the output of UPS
16) Charger :- Should have built in charger of minimum 10 Amp.
(separate from rectifier)
17) IGBT bith side input and inverter side
18) SNMP Kit card.
19) Parallel Redundant Kit
20) Input phase correction kit.
21) Back-up time :- 30 min. with SMF Batteries.
Cost of 10 KVA ON LINE 3 Phase in and 3 Phase out UPS Set
B) SITC OF BATTERY AND ITS ACCESSORRIES
i) SITC of MS Battery Rack suitable for 10 KVA UPS
ii) Supply, fitting, fixing, commissioning and testing of 40/63Amp. DC
Breaker with UV relay Coil. Make:- L&T, Siemens, Schneider,
iii) Supply, fitting, fixing, commissioning and testingof 12V 42AH - 20
nos. Sealed Maitanace Free (SMF) Battery with 24 months
replacement guaranty. IS:1652:1991. (VAH Required 21600 for
10 KVA UPS (42AH x 20 Nos. x 12V = 10080 VAH) Make:-
Battery-Exide, Amar-Raja, Quantum.
Cost set of of SMF Batteries , Battery Leads, MS Rack & DC Set
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
Total Cost of one set 10 KVA UPS along with Battries and Set 1 496,217.00 496,217.00
asseccories (A+B)
2 N.S. MAIN LT PANEL
Supplying, designing, manufacturing, installation, un loading at
site, shifting to location, testing and commissioning in correct
alignment position, effecting proper connection of all incomer and
outgoing of Main Panel as per IS 86230 and IEC 60439 and
strictly as per technical specification for the said Main LT Panel of
the Campus. The said Main LT Panel shall be factory built floor
mounting with Base Channel size - 75 mm x 40 mm x 6 mm, (or
ISMB CHANNEL) IP-42, with proper lifting arrangement
completely modular and compartmentalized made of CRCA Sheet
of 2 mm thick (14 SWG) (Load and un load Bearing.)
The Panels should be Ethernet/ Modbus ready suitable for
monitoring and control with BMS System through Multifuction
meter and miroprocessor incoming feeders if required.
Panel builder shall include all necessary hardwares in their scope
to make LT panel ethernet ready and submit communication test
report during panel testing at shop floor.
The sheet steel under go minimum 7 tanks treatment followed by
finishing of powder coating of minimum 60 micron thickness, duly
compartmentalized having accessories mounted inside the cubical
panel, earthing with 2 Nos. earth studs.
LT Panel shall have 20% spare outgoing feeders for different
rating. The Panel shall be preferably arranged in multitier
formation. The size of the panel shall be designed in such a way
that the internal space is sufficient for hot air movement, and the
electrical component do not attain temperature rise more than 40
degree Celsius.
The LT Panel shall be totally enclosed, completely dust and
vermin proof. Synthetic rubber gaskets (neoprene/DPDM)
between all adjacent units and beneath all covers shall be
provided to render the joints dust proof. All doors and covers shall
be fully gasketed and shall be lockable. Doors shall have
concealed hinges. All the doors shall be suitably reinforced by
channel to provide rigidity. Panel shall have suitable cable entry
from bottom/Top and suitable arrangement for aluminum cable
The panel shall be provided with a thermostatically controlled
heating arrangement (200 W) to take care of high humidity
conditions. A 6/16A socket with switch as service outlet (single
phase) and 1 no. 10W LED LAMP with holder shall be provided in
one of the compartments as service outlet in the panel. The
complete panel shall be fuse less type, for control circuits 2A SP
MCB's to be used.
For the protection of equipment & feeders, switchgear shall be
provided with required O/C, S/C releases. Selection of switchgear
rating shall be made on the basis of load current & fault withstand
The LT Panel electrical infrastructure should be technically
superior and it should not be the cause of untoward incidences
like fire, electrical shock etc and if it happens the system should
be designed in such a way that it will trip the faulty section fast
and localize the fault and continuity of power should be ensured
in healthy sections. Fast fault localization will help to identify the
area, hence down time will be less and system can be made back
in fastest possible time.
SLD will be submitted by the contractor for approval to
Engineering Incharge/Consultant before submitting the Main
Panel drawing. Based on approved SLD, contractor will provide
the GA drawing of Panel. Inspection of the Panel shall be carried
out at Panel Builder's factory by the Consultant before final
delivery. (Panel Builder should follow all norms of as per IS 86230
All openings shall be covered by soft rubber gasket, enclosure
shall be galvanized. Panel shall have suitable cable entry from
bottom and suitable Bus arrangement for aluminum cables for all
AL. BUS BAR:- The Main LT Panel includes 415V, 500A, TPN AL.
Busbar 50Hz,busbars shall be made of high conductivity, and high
strength Aluminum E91 grade Busbars shall be of rectangular
cross sections , not more than 6mm thickness better suitable for
full load current for phase bus bars and half/ full rated current for
neutral bus bar or as stipulated in schedule of quantities. Busbar
shall be suitable to withstand the stresses of fault level as
specified in schedule of quantities removable glands plates, cable
glands at sending and receiving ends, including connection with
outgoing Feeders complete in all respects.
Location : IN PANEL ROOM /Near Stair
The Name Plate for each feeder must be in Anodized Aluminium
MCCB:- L&T-DSine/ LEGRAND-DPX³/SCHNEIDER-NSX/ SIMENS-
MCB- C Series 10kA _ Legrand- DX³/Schneider- ACTI-9/Siemens-
Beta Guard/ L&T- AU VERSION.
Panel Size - As per Drawing and shall be provided at the time of
All 4 pole MCCB with microprocessor based release must
have following characteristics:-
1. Pre alarm LED signal under over load.
2. Over heat signal when inernal temp. reaches 75 degree C.
3. Separate LED fault indicator for each fault.
4. Logic selectivity (inbuilt delay 0f 50 ms beteen upstream and
down stream breaker)
5. Adujustable neutral pole.
6. Non sensitive to temp. veriation.
7. Control of load (only selective one)
8. With positive Isolation Marked.
9. With 8 steps adjustable short circuit and over load current and
with earth fault indication.
10. Line load inerchangeable.
11. As per IEC 60947-2.
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
All 4 pole MCCB with thermomagnetic based release must
have follwing characterstics:-
1. Icu=100% Ics.
2. With positive Isolation Marked.
3. With adjustable short circuit and over load.
4. As per IEC 60947-2.
All Incomer and all out going feeders (up tp 100 A) shall have
ON/OFF/TRIP indications.
1 Set of Fabrication part of LT Panel & busbar system, with AL. Set
bus bar and interconnection FRLS cables) in 14 SWG (2 mm
Thick) CRCA Sheet Steel enclosure (IP-42) without components.
Name of Panel builders -Name of Panel builders:- EAP Kolkat,
Green Galaxy Kolkata, JMD, Kokar, Ranchi, Meditiron -Sidro, BIT
Meshra. SPC Electrotech , (PART A) (PANEL BUILDER MUST
HAVE CPRI APPROVAL)
9 Nos. LED indicatore (RYB) of 220V. 1 Set. (R Y-& B) with 2A Each
SP MCB protection. Make- Esbee/Schendier/Siemens/L&T /
3 Set Multifunction Meter having (5010 Series) LED mete display Set
accuracy Class 1 as per IEC 62053-21, should have an active RS-
485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters:
Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs,
Onhrs Interrupts, THD for V&I per phase, individual harmonics for
V&I upto 15th level complying with IEC61557-12. Min/Max for
eight parameters. Sampling rate: 128 samples per cycle.
(provision for IP Convertor module, so that it can be integrated
with EMS/ BMS by the System Integrator) Make:-L& T 5010
Series/ SCCHEIDER-EM6400/ Legrand-EDMX3/CX3/PMX /Trinity
9 No. CT of different power as per incomer feeder 400/5VA -5 no
class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:- G&M / AE /
ECS / Kappa/Matrix
Bill of Material of MAIN LT PANEL
Provision of Auto interlocking between 400A/FP/50KA MCCB as
common incoming and 1 No. of 400A on load Automatic Change
over for 2 sources of supply , in such a way so that the two
supplies are not parallel at any time.
2 nos. 400A/FP/MCCB (50kA) with adjustable Microprocessor nos
release , with S/C, O/L & E/F protection, with ON OFF TRIP
indication alomg with extended front rotary handle and spreader
links including the provision of all components like UV, 4 poles
contactors etc, control cables for electrical interlocking the 2
incoming feeders ). (Feeder Cable Size :- 1 Run 3.5 C 300 SQ
MM AL. AR. Cable.)
1 no. 400A TPN , 415V, 3 Phase, on load Automatic Change over no
panel mounted open execution type with extended handle.
(Feeder Cable Size :- 1 Run 3.5 C 300 SQ MM AL. AR. Cable.)
Make:_Legrand / Schneider / Siemens / ABB / L&T
1 no. 400A/FP/MCCB (50kA) with adjustable Microprocessor no
release , with S/C, O/L & E/F protection, with ON OFF TRIP
indication alomg with extended front rotary handle and spreader
links. (including the provision of all components like UV, 4 poles
contactors etc., conrol cables, for electrical interlocking with auto
change over) ) As DG FEEDER. (AS DG IS WITH AMF PANEL
FOR THAT REQUIRED CONTROL CABLE TO SENCE EXISTING
AMF PANEL-Note:- Control Cable is in Clint's Scope) (Feeder
Cable Size :- 1 Run 3.5 C 300 SQ MM AL. AR. Cable.)
1 No.160 A F/P MCCB (50kA) with adjustable thermomagnetc no
release type with S/C & O/L protection, and front extended rotary
Handle and spreader links in both end Cable Size 3.5 C 95
Sq.mm Al,Ar, Cable)
8 nos. 63A F/P MCCB (25kA) with adjustable thermomagnetc no
release type with S/C & O/L protection, spreader links and front
5 nos. 25A F/P MCCB (25kA) with adjustable thermomagnetc no
release type with S/C & O/L protection, spreader links and front
2 nos. 32 A /DP/ MCB (10kA)/C Series. no
Total Cost of Main LT Panel. Set 1 908,793.00 908,793.00
3 N.S. LT PANEL FOR HVAC OUT DOOR & UINDOOR UNITS
Supplying, designing, manufacturing, installation, un loading at
site, shifting to location, testing and commissioning in correct
alignment position, effecting proper connection of all incomer and
outgoing of LT Panel for HVAC indoor and out door Units as per
IS 86230 and IEC 60439 and strictly as per technical specification
for the said LT Panel of the Campus. The said LT Panel shall be
factory built wall mounted with Base Channel size -35 mm x 35
mm x 4 mm, (or ISMB CHANNEL) IP-42, with proper lifting
arrangement completely modular and compartmentalized made
of CRCA Sheet of 2 mm thick (14 SWG) (Load and un load
Panel builder shall include all necessary hardwares in their scope
to make LT panel ethernet ready and submit communication test
report during panel testing at shop floor.
The Panels should be Ethernet/ Modbus ready suitable for
monitoring and control with BMS System through Multifuction
meter and miroprocessor incoming feeders if required.
The sheet steel under go minimum 7 tanks treatment followed by
finishing of powder coating of minimum 60 micron thickness, duly
compartmentalized having accessories mounted inside the cubical
panel, earthing with 2 Nos. earth studs.
LT Panel shall have 10% spare outgoing feeders for different
rating. The Panel shall be preferably arranged in multitier
formation. The size of the panel shall be designed in such a way
that the internal space is sufficient for hot air movement, and the
electrical component do not attain temperature rise more than 40
degree Celsius.
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
The LT Panel shall be totally enclosed, completely dust and
vermin proof. Synthetic rubber gaskets (neoprene/DPDM)
between all adjacent units and beneath all covers shall be
provided to render the joints dust proof. All doors and covers shall
be fully gasketed and shall be lockable. Doors shall have
concealed hinges. All the doors shall be suitably reinforced by
channel to provide rigidity. Panel shall have suitable cable entry
from bottom/Top and suitable arrangement for aluminum cable
The panel shall be provided with a thermostatically controlled
heating arrangement (200 W) to take care of high humidity
conditions. A 6/16A socket with switch as service outlet (single
phase) and 1 no. 10W LED LAMP with holder shall be provided in
one of the compartments as service outlet in the panel. The
complete panel shall be fuse less type, for control circuits 2A SP
MCB's to be used.
For the protection of equipment & feeders, switchgear shall be
provided with required O/C, S/C releases. Selection of switchgear
rating shall be made on the basis of load current & fault withstand
The LT Panel electrical infrastructure should be technically
superior and it should not be the cause of untoward incidences
like fire, electrical shock etc and if it happens the system should
be designed in such a way that it will trip the faulty section fast
and localize the fault and continuity of power should be ensured
in healthy sections. Fast fault localization will help to identify the
area, hence down time will be less and system can be made back
in fastest possible time.
SLD will be submitted by the contractor for approval to
Engineering Incharge/Consultant before submitting the Main
Panel drawing. Based on approved SLD, contractor will provide
the GA drawing of Panel. Inspection of the Panel shall be carried
out at Panel Builder's factory by the Consultant before final
delivery. (Panel Builder should follow all norms of as per IS 86230
All openings shall be covered by soft rubber gasket, enclosure
shall be galvanized. Panel shall have suitable cable entry from
bottom and suitable Bus arrangement for aluminum cables for all
AL. BUS BAR:- The LT Panel includes 415V, 200 A, TPN AL.
Busbar 50Hz,busbars shall be made of high conductivity, and high
strength Aluminum E91 grade Busbars shall be of rectangular
cross sections , not more than 6mm thickness better suitable for
full load current for phase bus bars and half/ full rated current for
neutral bus bar or as stipulated in schedule of quantities. Busbar
shall be suitable to withstand the stresses of fault level as
specified in schedule of quantities removable glands plates, cable
glands at sending and receiving ends, including connection with
outgoing Feeders complete in all respects.
Location : Inside Stair of terrace Floor.
The Name Plate for each feeder must be in Anodized Aluminium
MCCB:- L&T-DSine/ LEGRAND-DPX³/SCHNEIDER-NSX/ SIMENS-
MCB- C Series 10kA _ Legrand- DX³/Schneider- ACTI-9/Siemens- Set
Beta Guard/ L&T- AU VERSION.
1 Set of Fabrication part of LT Panel & busbar system, with AL. Each
bus bar and interconnection FRLS cables) in 14 SWG (2 mm
Thick) CRCA Sheet Steel enclosure (IP-42) without components.
Name of Panel builders -Name of Panel builders:- EAP Kolkat,
Green Galaxy Kolkata, JMD, Kokar, Ranchi, Meditiron -Sidro, BIT
Meshra. SPC Electrotech , (PART A) (PANEL BUILDER MUST
HAVE CPRI APPROVAL)
3 Nos. LED indicatore (RYB) of 220V. 1 Set. (R Y-& B) with 2A Set
SP MCB protection. Make- Esbee/Schendier/Siemens/L&T /
1 Set Multifunction Meter having (5010 Series) LED mete display no.
accuracy Class 1 as per IEC 62053-21, should have an active RS-
485 port, in built RTC, Aux Supply: 44-277Vac/dc. Parameters:
Volts, Amps, PF, THD, F, W, Wh, VA, VAh, Var, Varh, Runhrs,
Onhrs Interrupts, THD for V&I per phase, individual harmonics for
V&I upto 15th level complying with IEC61557-12. Min/Max for
eight parameters. Sampling rate: 128 samples per cycle.
(provision for IP Convertor module, so that it can be integrated
with EMS/ BMS by the System Integrator) Make:-L& T 5010
Series/ SCCHEIDER-EM6400/ Legrand-EDMX3/CX3/PMX /Trinity
9 No. CT of different power as per incomer feeder 160/5VA -5 nos
class one Epoxy resin cast CT (3 Nos.)=1 Set. Make:- G&M / AE /
ECS / Kappa/Matrix
Bill of Material of LT PANEL
1 No.160 A F/P MCCB (50kA) with adjustable microprocessor Set
release type with S/C & O/L protection, with front extended rotary
Handle and spreader links in both end Cable Size :- 1 R, 3.5 C 95
Sq.mm Al,Ar, Cable)
3 nos. 63A F/P MCCB (25kA) with adjustable thermomagnetc set
release type with S/C & O/L protection, spreader links and front
3 Nos. 40A/FP/MCCB/10kA with adjustable thermomagnetc Set
release type with S/C & O/L protection, with spreader links and
front rotary handle, (1 nos. as spare).
1 Nos. 25 A FP MCCB (25KA) with adjustable thermomagnetc Set
release type with S/C & O/L protection, With spreader links and
front rotary handle, (1 nos. as spare).
Total Cost of HVAC VRV AC INDOOR & OUT DOOR UNITS LT Set 1 321,416.00 321,416.00
4 N.S. Supply of following size of 1.1KV XLPE / PVC Insulated / PVC
sheathed (Heavy Duty) armoured electric cable with aluminium
conductor as per IS 7098 (Part-1) 1988 with upto date
Amendments. Make:- As per approved Make List (Make:- Havell’s,
i) Supply of 3.5 Core 300 Sq. mm. XLPE PVC Al. / Ar. Cable 1.1 KV Mtr 200 3,020.00 604,000.00
ii) Supply of 3.5 Core 95 Sq. mm. XLPE PVC Al. / Ar. Cable 1.1 KV Mtr 30 1,039.00 31,170.00
iii) Cost of 3.5 Core 35 Sq. mm. XLPE PVC Al. / Ar. Cable 1.1 KV Mtr 75 455.00 34,125.00
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
5 N.S. Supply, fitting fixing and testing of 63A FP/10kA, C Series MCB Each 8 2,745.00 21,960.00
(Make:-MCB-LEGRAND- DX³/SCHNEIDER- ACTI-9/SIEMENS-
BETA GUARD/ L&T- AU VERSION.)
6 FANS & EXHAUST FANS
N.S. Suitable size & capacity Ceiling Fans/ Wall Fans (White/Off White
color) shall be provided as per the details given below. All Ceiling
fans shall be of 5 star rating and energy efficient. Similarly all wall
fans and Exhaust must be of best quality. Warranty for all fans
shoulkd be 2 years. Make:- Havells, Crompton, Usha,
i) N.S.i) Supply, fitting, fixing and testing of 1200mm sweep ceiling fans Each 15 5,277.00 79,155.00
complete without regulator, double ball bearing, motor, blades,
down rod, canopies, capacitor, suitable for operation on 230 volts,
50 Hz., 1 phase, AC supply connection with 1.5 sq.mm PVC FRLS
Copper wire complete as required, (BLDC 5 Star (32 Watt)
IS:374:2019 (energy efficient fan) . Colour of Ceiling Fan-
(White/Off White color)
ii) (N.S.v) Supply of Wall Fan 400mm 230V with blade, guard (net), Each 44 3,084.00 135,696.00
revolving type with regulator system and proper stand and fixing
bracke, (plastic body).
iii) (N.S.iii) Supply of 230V AC single phase, Exhaust Fan (230 mm- 1400 Each 11 2,261.00 24,871.00
RPM), double ball bearing (Metal Body, metalick blade, Light
Duty) exhaust fan as required.
iv) (N.S.iv) Supply of 230V AC single phase, Exhaust Fan (300 mm- 1400 Each 2 2,536.00 5,072.00
RPM), double ball bearing (Metal Body, metalick blade,- Light
Duty) exhaust fan as required.
7 N.S. LED LUMINAIRES LIGHTS
Note:- LED Luminaire manufacture shall provide LM79 report
from NABL accredited lab & LM80 report issued by LED
manufacturer. Samples of all type LED light fixtures are to be
submitted to the Engineering Incharge and each LED Light should
have 100lm/W for the approval prior to procurement of light
fixtures. Make:- K-Lite/ XAL/Ledvance/Philips /Wipro /Havells.
Make of LED Chip:- Philips/ Osram/Cree/Nichia.
N.S. Supply fitting fixing of follwing LED Light Fixtures :-
K - Lite make ID - 3322, Diva Deep Round 18 W CW Recessed Each 335 2,047.00 685,745.00
LED down Lighter.
K - Lite make ID - 3485, Trio 1200 mm. suspended Linear Light. Each 6 9,611.00 57,666.00
iii) Ledvance make LDVAL LINEAR SPOT 5X2W Recessed type. Each 50 3,175.00 158,750.00
K - Lite make ID - 3497, NEO Pendant Direct upto 40W, Length - Each 26 7,928.00 206,128.00
Ledvance make 15W/Mtr 24v with Driver Complete set, Length 5 Each 40 5,100.00 204,000.00
K - Lite make ID - 3612, Bema-7, 12W LED Round Surface Light Each 70 1,619.00 113,330.00
Decorative type Chandalier light with LED lamp Complete set. Each 1 22,250.00 22,250.00
vii) SITC of 2x12.5 W (25W) LED outdoor UP-DOWN light (Warm Each 12 10,658.00 127,896.00
Light) with IP:65 /IP-66 protection, die cast aluminium housing.
(LM 79 and LM 80 reports need to be submitted , 50,000 burning
hrs,) (Out DOOR USE) (make-Havells, Philips, K-lite, )
7 N.S Supply, fitting, fixing, installation & testing of Water storage 15 Each 14 13,166.00 184,324.00
Liters Geyser of BEE 5-star rating (Energy Efficient) vertical type
acralic rust free body, facility of temperature control ,with capillary
themostat and thermal cut, ISI certified heating element along with
inlet & outlet connecting pipe, fixing clamps, fasteners, etc. as
required. Make:- Venus / Bajaj / Havells
TOTAL OF NON SCHEDULE ITEMS (PART-B)(ELECTRICAL) 4,422,564.00
N.S. VARIABLE REFRIGERANT FLOW SYSTEM (PART-C)
1 N.S. Supply, Installation, Testing & Commissioning of Hi efficient DC
Inverter Side discharge VRF Outdoor units equipped with Variable
refrigerant flow system (Heating & Cooling), comprising Inverter
driven Scroll Compressor with a wide range of frequency from
15 to 120 rps ( R-410A refrigerant gas) . All the unit shall be
provided with micro- processor based control advance refrigerant
control , Liquid back flow protection , precise oil control
technology, 3ph DC motor condenser fan motor , subcooling
through dual tube heat exchanger & various electrical protection
like-phase sequence, high /low voltage protection ,compressor
overload protection, temperature & pressure protection.
Approved make : Fujitsu-General/ Mitsubishi Heavy/
A. OUT DOOR UNITS
i Nominal Capacity: 14 HP Nos. 1 450,666.00 450,666.00
ii Nominal Capacity: 12 HP Nos. 2 356,171.00 712,342.00
B. INDOOR UNITS
Supply of 4-Way Cassette type Indoor Unit with nominal capacty
3.5 TR, air flow not less than 1118 CFM & sound pressur level not
more than 46 db with Remote Grill kit &receiver kit.
Approved make : Fujitsu-
General / Mitsubishi Heavy / Panasonic.
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
ii Supply of 3D Flow Cassette type Indoor Unit with nominal capacty Nos. 5 125,127.00 625,635.00
2.0 TR, air flow not less than 612 CFM & sound pressur level not
more than 46 db with Remote, Grill kit &receiver kit.
Approved make : Fujitsu-
General / Mitsubishi Heavy / Panasonic.
iii Supply of 3D Flow Cassette type Indoor Unit with nominal capacty Nos. 2 123,310.00 246,620.00
1.5 TR, air flow not less than 512 CFM & sound pressur level not
more than 41 db with Remote, Grill kit &receiver kit.
Approved make :
Fujitsu-General / Mitsubishi Heavy / Panasonic.
C Supply of Y-Joints Nos. 10 7,139.00 71,390.00
Approved make : Fujitsu-General / Mitsubishi Heavy /
D Supply of ceiling mounted non-vrf 4-way Cassette with nominal Nos. 1 114,484.00 114,484.00
capacity 2.0 TR with non-CFC refrigerant, Cu condenser, Rotary
type compressor and DC fan motor with ambient temperature
operating range 21deg C ~ 52deg C with 360 degree turbo flow
along with corded/cordless remote.
Approved make: Fujitsu-General / Mitsubishi Heavy /
E Supply of ceiling mounted non-vrf 4-way Cassette with nominal Nos. 1 136,030.00 136,030.00
capacity 3.0 TR with non-CFC refrigerant, Cu condenser, Rotary
type compressor and DC fan motor with ambient temperature
operating range 21deg C ~ 52deg C with 360 degree turbo flow
along with corded/cordless remote.
Approved make: Fujitsu-General / Mitsubishi Heavy /
F SITC of Refrigerant Gas (R410a) Charging as per site Kgs. 30 1,752.00 52,560.00
requirements. Make : Dupont, Floron.
Installation, Testing and Commissioning of the VRF ODU/IDU with
cordless remote including lifting, shifting and complete with
insulation of all refigeration pipe joints
I VRF type ODU
12 HP (Heating and Cooling) Nos. 2 20,768.00 41,536.00
14 HP (Heating and Cooling) Nos. 1 24,922.00 24,922.00
II VRF type IDU
i 3.5 Tr 4-way Cassette Unit Nos. 6 4,543.00 27,258.00
ii 2.0 Tr 3D flow type Cassette Unit Nos. 5 4,543.00 22,715.00
iii 1.5 Tr 3D flow type Cassette Unit Nos. 2 4,543.00 9,086.00
III NON-VRF type Cassette units
G SITC of VRF Refrigerant Piping,
Supply Installation and Testing of Refrigerant pipe with 19mm/13
mm thick) closed cell elastomeric nitrile rubber tubular insulation
between each set of indoor & outdoor units complete with
necessary connecting Y joints and other accessories as per
specifications, all Refrigerant Pipe Should Run on cable trays of
required Size and should be complete with Supports ,Hangers etc.
Make- Rajco/Mandev.
i 28.6 mm O.D.(with 19 mm insulation ) Rmtr. 40 1,882.00 75,280.00
ii 22.2 mm O.D.(with 19 mm insulation ) Rmtr. 10 1,233.00 12,330.00
iii 19.05 mm O.D.(with 19 mm insulation ) Rmtr. 15 1,012.00 15,180.00
iv 15.8 mm O.D.(with 19 mm insulation ) Rmtr. 70 994.00 69,580.00
v 12.7 mm O.D.(with 13mm insulation ) Rmtr. 85 844.00 71,740.00
vi 9.52 mm O.D.(with 13mm insulation ) Rmtr. 40 714.00 28,560.00
vii 6.35 mm O.D.(with 13mm insulation ) Rmtr. 20 467.00 9,340.00
H SITC of Non-VRF refrigerant Piping
Supply, Installation, Testing and Commissioning of Cu ref Pipe for Rmtr. 25 1,272.00 31,800.00
non-vrf Cassette type Units
I SITC of rigid PVC Drain Piping complete with fittings, supports as
per specifications and duly insulated with 6 mm thick closed cell
nitrile rubber insulation. Make-Supreme,Astral,Finolex,
J SITC of control cum transmission wiring of Copper conductor
cable along with conduit for looping between indoor & outdoor
VRF system . Make- Lapp/ Belden.
i 2 C X 1 Sq. mm Shielded for VRF Rmtr. 225 247.00 55,575.00
ii 4C X 2.5 Sqmm for Non-VRF Rmtr. 40 319.00 12,760.00
K SITC of Anti Vibration Rubber Pad. Lot 1 11,163.00 11,163.00
L SITC of OD Bracket for cassette Units Nos. 2 1,233.00 2,466.00
M Supply and Fabrication of MS platform for VRF type OD unit Kg. 75 228.00 17,100.00
N Lifting Shifting of outdoor units Lot 1 26,998.00 26,998.00
O SITC of Suction Filter & Ball Valve for ODU. Make : Dafoss, Nos. 3 13,629.00 40,887.00
TOTAL OF VARIABLE REFRIGERANT FLOW SYSTEM (PART-C) 3,630,421.00
1 N.S. (SURVEILLANCE CCTV SYSTEM) (PART-D)
i) 2MP IP IR Bullet Camera
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
SITC of 2MP EPOE IP IR BULLET CCTV CAMERA HAVING Nos. 0 34,586.00 0 ITEM NOT
FOLLOWING FEATURES: EPOE SUPPORT; EFFECTIVE CONSIDERTD ,
PIXELS: 1920(H) X 1080(V); MINIMUM SAME WILL BE
ILLUMINATION:0.006LUX/F1.4 COLOR,1/3S,30IRE); PROCURED
0.05LUX/F1.4 ( COLOR, 1/30S, 30IRE);0LUX/F1.4 (IR ON); IR SEPARATELY.
DISTANCE: DISTANCE UP TO 50M (164FT); LENS
TYPE:MOTORIZED; FOCAL LENGTH: 2.7MM~13.5MM; OPTICAL
ZOOM: MIN 5X; VIDEOCOMPRESSION: H.265+/H.265/
H.264+/H.264; VIDEO RESOLUTION: 1080P(1920X1080)/
FRAME RATE: MAIN STREAM: 1080P(1~50/60FPS);BIT RATE:
H.264: 24~9472KBPS H.265: 14~5632KBPS; AUDIO
COMPRESSION:G.711A/ G.711MU/ AAC/ G.726; ETHERNET: RJ-
45 (10/100BASE-T);INTEROPERABILITY: ONVIF, PSIA, CGI;
VIDEO INTERFACE: 1 PORT; AUDIOINTERFACE: 1/1 CHANNEL
IN/ OUT; POWER SUPPLY: DC12V, POE (802.3AF)(CLASS0);
INGRESS PROTECTION: IP67; ACCESSORIES INCLUDED:
COMPATIBLE POWERSUPPLY ADAPTER WITH 3A RATING,
MOUNTING STAND, COMPATIBLE MOUNTINGSTAND, 64 GB
CLASS 10 MICRO SD CARD, 2 NOS. RJ-45 CONNECTORS
WITH BOOTS. PREFERED MAKE: HIKVISION/ HONEYWELL/
ii) 2MP IP IR Dome Camera:
SITC of 2MP IP IR FIXED VF DOME CCTV CAMERA HAVING Nos. 0 31,763.00 0 ITEM NOT
FOLLOWING FEATURES: EFFECTIVE PIXELS: 1920(H) CONSIDERTD ,
X1080(V); MINIMUM ILLUMINATION: 0.006LUX/ F1.4 SAME WILL BE
(COLOR,1/3S,30IRE); 0.05LUX/F1.4 (COLOR,1/ 30S,30IRE); PROCURED
0LUX/F1.4(IR ON); IR DISTANCE: DISTANCE UP TO 30M(98FT); SEPARATELY.
LENS TYPE: MOTORIZED; FOCAL LENGTH: 2.7MM~13.5MM;
VIDEO COMPRESSION:
H.265+/H.264+/H.265/H.264/MJPEG(SUB STREAM);
CIF(352×288/352×240); FRAME RATE: MAIN STREAM: 1080P(1
~ 25/30FPS); BIT RATE: H.265: 12K ~ 6400KBPS,H.264: 32K ~
10240KBPS; AUDIO COMPRESSION: G.711A/ G.711MU/ AAC/
G.726; ETHERNET: RJ-45 (10/ 100BASE-T);
INTEROPERABILITY: ONVIF PROFILE S&G, API; POWER
SUPPLY: DC12V, POE (802.3AF)(CLASS 0); OPERATING
CONDITIONS:-30° C ~ +60° C / LESS THAN 95% RH; INGRESS
PROTECTION: IP67; ACCESSORIES INCLUDED: COMPATIBLE
POWER SUPPLY ADAPTER WITH 3A RATING,COMPATIBLE
MOUNTING STAND, 64 GB CLASS 10 MICRO SD CARD, 2 NOS.
RJ-45 CONNECTORS WITH BOOTS.
PREFERED PREFERED MAKE: HIKVISION/ HONEYWELL/
iii) IP PTZ CAMERA
SITC of 2MP IP IR PTZ CAMERA WITH 64GB CLASS 10 MICRO Nos. 0 117,876.00 0 ITEM NOT
SD CARD HAVING FOLLOWING FEATURES: EFFECTIVE CONSIDERTD ,
PIXELS: 1920X 1080;MINIMUM ILLUMINATION: COLOR- SAME WILL BE
0.005 LUX; IR DISTANCE: UPTO 150M; FOCAL LENGTH: PROCURED
MINIMUM 4 MM; PAN SEPARATELY.
RANGE: 0 DEG TO 360 DEG ENDLESS; TILT RANGE: -15 DEG
TO 90 DEG; OPTICAL ZOOM: 30X; VIDEO COMPRESSION:
H.265+/H.265/H.264+/H.264; AUDIO COMPRESSION:
G.711A/G.711U/AAC; NETWORK: RJ-45 (10 BASE-T/100 BASE-
T); INTEROPERATIBILITY: ONVIF/PSIA/CGI; USER: MINIMUM
20; POWER SUPPLY: AC 24V/3A, POE+-802.3AT; OPERATING
CONDITIONS: -10DEG C TO 60 DEG C; INGRESS
PROTECTION: IP66 OR BETTER; ACCESSORIES INCLUDED:
COMPATIBLE POWER SUPPLY ADAPTER WITH 3A RATING,
COMPATIBLE MOUNTING STAND, 64 GB CLASS 10 MICRO SD
CARD, 2 Nos. RJ-45 CONNECTORS WITH BOOTS.
/HIKVISION/HONEYWELL/CP PLUS/ TYCO.
iv) . 32 Channel NVR Processor :-
SITC OF Dual-core embedded processor,Operating System : Pre- No. 0 172,649.00 0 ITEM NOT
loaded Licensed OS,IP Camera Support : Min 32 Channel or CONSIDERTD ,
higher,Two way talk : 1 Channel O/P and 1 Channel SAME WILL BE
I/P,Compression : H.265, H.264, MJPEG4,Video Resolution: PROCURED
Should support up to 8MP IP Camera. Video Recording (Incoming SEPARATELY.
bandwidth) : 256 Mbps,Video Display Split : 1/4/8/16/32,Video
Loss : Support,Camera Blank : Support,Alarm Input/ Output : Min
16 channel / Min 4 Channel or betterHard Disk : Min 8 SATA ports
, up to 32TB , Raid(Redundancy), ,Smart Phone : iPhone, iPad,
Android, Windows,Phone,Protocol : IPv4/IPv6, HTTP, HTTPS,
SSL, TCP/IP,UDP, UPnP, ICMP, IGMP, SNMP,RTSP, RTP,
SMTP,NTP, DHCP, DNS, PPPOE, DDNS, FTP, IP Filter,ONVIF
Profile S,User Account : 10 Users,Trigger Event : Recording,
Alarm, Video Push, Email,FTP,Recording Mode : Manual ,
Schedule , STOP,Search Mode : Time/Date , Alarm , Motion
Detection ,Exact Search (accurate to second), Smart
Search,Playback : Play, Stop, Pause, Rewind, Fast Play, Next file,
Previous file, Next Camera, Previous Camera, Full Screen,
Backup Selection,Backup Mode : USB Device / Internal SATA /
NetworkInterface Ports : 2 USB 2.0 , 1 RS485 , 1,RS232, 2
RJ45,Ethernet Ports : 2 RJ-45 port (10/100M/1000M),Power SITC
: AC 100V~240V 50/60Hz,Regulatory : CE, FCC,UL and RoHS.
Web viewer, CE, FCC, UL certified capable of Survelliance SD
Crad , and 32 TB storage. Make- /Hikvision/Pelco/ Honeywell /CP
v) 9 U WALL MOUNT EQUIPMENT RACK
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
SITC of of 9 U Wall Mounted EQUIPMENT Cabinet No. 1 14,470.00 14,470.00
504.65X600X500 (HXWXD): Rack must be along with the
following components like; Width (mm)-600, Depth (mm) - 500,
Approx.Net Wt (kg) - 10-12, CRCA 'D' Grade thickness (mm) - 1.2,
RAL 9017 (Matt Black), Glass - 4mm Toughened Tinted Glass
Door, Accessories:, Cooling Fan (230V A/C 90 CFM) - 2 Nos,
PDU 230VAC - 1 No, Cable Manager Metal- 2 Nos, Mounting
Hardware (20 sets of M6 screws,washer,cage nuts (nickel
coated)) - 1 No, Wall Screws (4 sets of 2'' screws, washer,rubber
grommet (nickel coated)) - 1 No, Door Lock - 1 No, Front Metal
Band -1 No. In the rack there must be maintained 1 U = 1.75
inches space. (Make : Legrand-VALRACK/ Netrack/Rittal/APW.)
(vi) SITC of SITC of 55" Full HD 1080p LED Panel; 24X7 Surveillance No. 0 90,595.00 0 ITEM NOT
Monito Make-As per Approved DBR make list.or Sony, LG, CONSIDERTD ,
Panasonic SAME WILL BE
vii) SITC of Surveillance class UHS-1 U3 -64 GB /Class 10 Micro SD Set 0 7,440.00 0 ITEM NOT
CARD ( V-30 ) for Camera. CONSIDERTD ,
viii) SITC OF Windows Surveillance Hard Disk (ST10000VX0004) Each 0 36,302.00 0 ITEM NOT
Capacity:- 8 terabyte (TB), Wattage:- 6.2, Operating Temperature:- CONSIDERTD ,
0 to +60 degree C. (1.7TB per camera for 30 days) (Make: SAME WILL BE
Seagate, WD, HP) PROCURED
ix) Patch Panel 24 Port for CAT-6 Cable:-
SITC of UTP Cat. 6 patch panels (Compartible for Armrmoured Set 1 20,893.00 20,893.00
CAT-6 Cable) equipped with 24 RJ 45 connectors 19" panel - 1U ,
Equipped with 4 cassettes of 6 pre-fitted Cat. 6 LCS³ RJ 45
connectors, Automatic cassette removal by simple pressure,Each
connector can be removed individually,T568A and B marking with
colour codes,Equipped with rear cable guide to hold cables during
maintenance,Supplied with coloured labels,Compliant with
ISO/IEC 11 801, EN 50173 and ANSI/TIA 568 standards,Flat
panels,24 RJ 45 connectors - 1U - PoE++ UTP ,Equipped with
new-generation Quick-Fix for automatic (screwless) mounting on
enclosure and cabinet uprights,Universal mounting on all cabinets
or enclosures,Panels ensure automatic earthing of each
connector, equipped with 4 bundles guides fixed at the rear.
(Make:-Legrand /Commscop/ RIT/Bendel
x) Supply fitting, fixing, and testing of Cat. 6 RJ 45 patch cords and no. 1 649.00 649.00
user cords ,RJ 45/RJ 45 - straight,With special “easy grip” plug
Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards, Shielded UTP, impedance 100 Ω,PVC,Length CAT6A
UTP Patch Cord - LSZH - 2mtr - Red, boot bioth end ; (Make:-
Legrand /Commscop/ RIT/Belde
xi) Supply fitting, fixing, and testing of BLUE/YELLOW color C of Nos. 24 424.00 10,176.00
Cat. 6 RJ 45 patch cords and user cords ,RJ 45/RJ 45 -
straight,With special “easy grip” plug Compliant with ISO/IEC 11
801, EN 50173 and ANSI/TIA 568 standards, Shielded UTP,
impedance 100 Ω,PVC, Length 1 mtr boot both end, for Rack
End.; (Make:-Legrand /Commscop/ RIT/Belde
xii) Providing, fixing, fitting, connecting and testing of 2 module white Each 12 706.00 8,472.00
RJ 45 Cat 6 Data outlet / (CAMERA END) Toolless information
outlets with white coloured RJ-45 transparent shuttered modular
scoket outlets with front plate. ETL verified to meet or exceed TIA
/ EIA category 6 requirements, universal wiring label permitting to
either T568A or T568B, UL listed, and B marking with colour
codes, for computer networking complete in all respect suitable to
fix in modular plate type switch system with connections as
required and Compiance with ISO/IEC 11 801, EN 50173 and
ANSI/TIA 568 standards. (Make:- Legrand- Arteor/Scheinder-
Zencelo/ Mk- Blenz)
xiii) SITC of Armoured CAT 6 UTP Cable for CCTV,Performance 500 Mtr 600 176.00 105,600.00
MHz, 4 pairs or 2x4 twisted pair cables, 100 Ω,Yellow RAL
1018,LSZH sheath: zero halogen. ANSI/TIA colour
code,Compliant witISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards,Products conforming to the new CPR regulation ,F/UTP
- 4 pairs,Length 500 m,Supplied on reel, :,Yellow : (to be drawn in
existing 25 mm PVC conduit or existing metal floor race way.)
Make:_ Belden, Legrand, Tyco, Digisol
xiv) L2 PoE Access Switch
Supply, fitting, fixing, connecting and testing of switch with 24 x 4X10 Gbps SFP for
10/100/1000T ports and (4x10 Gbps SFP+ Port for up linking) , uplinking should be
Switching Capacity 56 Gbps and Forwarding Rate 41.7Mpps, included.
Switch should support PoE and PoE+ with 370W minimum power (Inducted )
budget, operaating temperature 0°C to 50°C, Switch should
support link reccovery within 50ms for Ring architecture, SDN or
similar kind of technolgy should support, Warranty 5 year from
Day 1 . Make:- Cisco / Allied Telesis / Juniper)
The above L2 Managed Data Switch consists of the following:-
1. Power cord India, right angle.
2. Both side Cable connector.
3. 1 year free service pack.
Interface- 24 x 10/100/1000T ports and (4x10 Gbps SFP+ Port
for up linking)
Switching Capacity/Forwarding Rate :- 56Gbps/41.7Mpps
Performance:- Up to 16K MAC addresses, 256MB DDR SDRAM
Management:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3,
powerful centralized management and zero-touch device
installation and recovery like SDN,
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
Security:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3,
powerful centralized management and zero-touch device
installation and recovery like SDN,
Routing:- IPv4 static routing and RIP.
Fail-over:- Switch capable of recovery within 50ms in a ring for
application high availability
IPv6:- Device management over IPv6 networks with SNMPv6,
Telnetv6, SSHv6 and Syslogv6
Diagnostic:- Optical Digital Diagnostics Monitoring,Automatic link
flap detection and port shutdown,Port and VLAN mirroring
Standard Protocol:- IEEE 802.1Q,IEEE 802.1w,IEEE 802.1s,IEEE
802.1p,IEEE 802.1AB,IEEE 802.1AX,IEEE 802.3ad
Operating Temparature:- 0°C to 50°C
Certification:- EN,UL and RoHS
Warranty:- 5 Years.
Cost of L2 PoE Access Switch Set 1 209,988.00 209,988.00
xv) Supply of Fiber Module 1310nm 10G Base-LR SFP module; The Nos. 2 58,197.00 116,394.00
detailed specification in Annexure 1 of this module is a part a
necessary part of the BOQ
xvi) Works Station-
SITC of Works Station- - i7-7700-WP/8GB+8GB/1TB/RWD+ - Set 0 296,454.00 0 ITEM NOT
AWT3630 Intel® CoreTM i7-8700/ 8GB/ 1TB/ Windows 10 Pro/ CONSIDERTD ,
19" Monitor/ DVDRW/ 3 years/ 2 GB Nvidia Graphics/ mDP Port/ SAME WILL BE
450W. Make:- Dell/Lenovo/HP PROCURED
xvii) SITC of Video Management Server on industry standard Server Set 0 317,630.00 0 ITEM NOT
and should be of the same OEM as of the camera as per the CONSIDERTD ,
detailed specification attached to the BOQ with license . Make:- SAME WILL BE
Hickvision/Honeywell/Sony/CP-Plus. PROCURED
TOTAL SURVEILLANCE CCTV SYSTEM (PART-D) 486,642.00
TELEPHONE SOLUTION (PART-E)
1 N.S. Krone box:-
Providing, fixing, connecting & testing of Krone box (Telephone
Tag Block) in a thermoplastic, IP 65 (weather proof) enclosure,
internally embedded gasket, anti corrosive, insulated and shock
proof with provision for cable through IP 65 glands complete in all
respects. (Make : Matrix/Alcatel/Avaya.
i) 10 pair Tag Block (krone Box) (136 mm x 253 mm x 115 mm) No. 2 1,073.00 2,146.00
ii) 20 pair Tag Block (krone Box) (136 mm x 253 mm x 115 mm) No. 2 1,238.00 2,476.00
iii) 50 pair Tag Block (krone Box) (300 mm x 300 mm x 70 mm) No. 2 2,228.00 4,456.00
iv) SITC of IPM with lightning protection. No. 15 237.00 3,555.00
2 N.S. Providing, laying, connecting, testing & commissioning of
telephone Unarmoured cables of conductor size 0.5 sq.mm.
high conductivity Solid Annealed Bare tinned Copper Telphone
cable (with ferrule) with high density Polythene insulation, Paired,
Polyester and seathed with high Oxygen Index, Fire Retradant,
PVC Compound, Gey Outer Sheath generally confirming ITD
Specification, laid on existing cable tray or along the wall or laid
through under floor chanel (Metal floor Race Way) as required.
(Make : Finolex / Polycab / Havells)
i) Cost of 5 pair Telephone Unarmoured cables of conductor size 0.5 Mtr 750 73.00 54,750.00
3 N.S. Providing, laying, connecting, testing & commissioning of Jelly
Filled telephone Unarmoured cables of conductor size 0.5
sq.mm. high conductivity Solid Annealed Bare Tinned Copper
Telphone cable (With Ferule) with high density Polythene
inssulated, petrolium Jelly Filled with Ploy Al. laminated Moisture
Barrier, ,Paired, Polythene seathed, unarmoured Polythene
Jacketed Telephone cable as per DOT Specification, laid on
existing cable tray or along the wall or laid through under floor
chanel (Metal floor Race Way) as required. (Make : Finolex /
Polycab / Delton /Commscope)
i) Cost of 10 pair PIJF UNARMOURED 10 PAIR TELEPHONE Mtr 1000 195.00 195,000.00
4 N.S. Providing, laying, connecting, testing & commissioning of Jelly
Filled telephone Armoured cables of conductor size 0.5 sq.mm.
high conductivity Solid Annealed Bare Copper Telphone cable
with high density Polythene inssulated, petrolium Jelly Filled with
Ploy Al. laminated Moisture Barrier, ,Paired, Polythene seathed,
unarmoured Polythene Jacketed Telephone cable as per DOT
Specification, laid on existing cable tray or along the wall or laid
through under floor chanel (Metal floor Race Way) as required.
(Make : Finolex / Polycab / Delton/Commscope)
i) Cost of 10 pair Te. Cable (1 Mtr.) Jelly Filled telephone Armoured Mtr 0 276.00 0.00
ii) Cost of 20 pair Te. Cable (1 Mtr.) Jelly Filled telephone Armoured Mtr 0 422.00 0.00
iii) Cost of 50 pair Tel. Cable. (1 mtr.) Jelly Filled telephone Mtr 5 911.00 4,555.00
Armoured cables
5 N.S. Digital Key Telephone Set
SITC OF DIGITAL KEY TELEPHONE WITH FULL DUPLEX
SPEAKERPHONE, 6 LINE BACKLIGHT LCD DISPLAY, 24
PROGRAMMABLE KEYS INCL. ALL ACCESSORIES WITH THE
FOLLOWING FEATURES:
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
FOR ON HOOK AND OFF HOOK CHANGEOVER DURING Set 0 21,091.00 0.00 ITEM NOT
CONVERSATION (HANDSET TO HANDS FREE OPERATION CONSIDERTD ,
AND VICE VERSA) SPEECH SHOULD NOT GET CUT AND SAME WILL BE
CONTINUE NORMALLY, SHOULD WORK ON SINGLE PAIR (2 PROCURED
CORE) 0.5 MM DIA COPPER TELEPHONE CABLE, AT LEAST 6 SEPARATELY.
LINES LCD DISPLAY, ON HOOK DIALING, AT LEAST 24
NUMBERS PROGRAMMABLE / ONE TOUCH KEYS WITHOUT
ANY ADDITIONAL PROGRAMMABLE KEY MODULE (ADD ON
MODULE), ICMCALLI NG, VOICE / VOLUME, RINGER
CONTROL KEYS (HANDS FREE INCREASE / DECREASE,
MICROPHONE, SPEAKER, MUTE), CALL HOLD FACILITY,
CONFERENCE AND DND KEYS, CLI : SHOULD SUPPORT
BOTH DTMF & FSK MODE. I/C CALLER¿S NAME & NUMBER
DISPLAY FROM INTERNAL AND EXTERNAL CALLERS, INDI
CATE BUSY EXTENSION, CALL FORWARDING (ALL, BUSY, NO
ANSWER), DATE & TIME DISPLAY ( 24-HOUR / 12-HOUR
FORMAT), FACILITY TO RETRIEVE I NCOMING,
ANSWERED,MISSED CALLS, CALL LOG, REDIAL FACILITY,
SPEED DIAL, ONE TOUCH DIALING TO INTERNAL AND
EXTERNAL PHONE NUMBERS, CO KEYS : TO ACCESS CO
LINES,RINGER LAMP, WORK ON TELEPHONE LINE VOLTAGE
ONLY AND NO EXTERNAL ADAPTORPrevious Camera, Full
Screen, Backup Selection,Backup Mode : USB Device / In
6 N.S. DIGITAL SELF LABELLING SOFTKEY TELEPHONE /IP Phone
SITC OF DIGITAL SELF LABELLING SOFT KEY TELEPHONE/IP Set 0 25,382.00 0.00 ITEM NOT
Telphone WITH FULL DUPLEX SPEAKER PHONE, 6 LINE CONSIDERTD ,
BACKLIGHT LCD DISPLAY, 24 PROGRAMMABLE KEYS, SELF SAME WILL BE
LABELLING SOFT KEY DISPLAY WITH MINIMUM 4 LINES PER PROCURED
PAGE INCL. ALL ACCESSORIES WITH THE FOLLOWING SEPARATELY.
FEATURES: FOR ON HOOK AND OFF HOOK CHANGEOVER
DURING CONVERSATION (HANDSET TO HANDS FREE
OPERATION AND VICE VERSA) SPEECH SHOULD NOT GET
CUT AND CONTINUE NORMALLY. SHOULD WORK ON SINGLE
PAIR (2 CORE) 0.5 MM DIA COPPER TELEPHONE CABLE, AT
LEAST 6 LINES LCD DISPLAY, ON HOOK DIALING, AT LEAST
24 NUMBERS PROGRAMMABLE / ONE TOUCH KEYS
WITHOUT ANY ADDITIONAL PROGRAMMABLE KEY MODULE
(ADD ON MODULE), ICM CALLING, VOICE / VOLUME, RINGER
CONTROL KEYS (HANDS FREE INCREASE / DECREASE,
MICROPHONE, SPEAKER, MUTE), CALL HOLD FACILITY,
CONFERENCE AND DND KEYS, CLI : SHOULD SUPPORT
BOTH DTMF & FSK MODE. I/C CALLER’S NAME & NUMBER
DISPLAY FROM INTERNAL AND EXTERNAL CALLERS
(ALPHANUMERIC DISPLAY), INDICATE BUSY EXTENSION,
CALL FORWARDING (ALL, BUSY, NO ANSWER), DATE & TIME
DISPLAY (24-HOUR / 12-HOUR FORMAT), FACILITY TO
RETRIEVE INCOMING, ANSWERED, TO INTERNAL AND
EXTERNAL PHONE NUMBERS, CO KEYS: TO ACCESS CO
LINES, RINGER LAMP, WORK ON TELEPHONE LINE VOLTAGE
ONLY AND NO EXTERNAL ADAPTOR SHOULD BE USED,
COLOUR: WHITE (PREFERRED). Make:- NEC /Panasonic/Alcatel.
7 N.S. IP based KTS (EPBX) system –
SITC of MULTILINE KEY TELEPHONE SYSTEM WITH VOIP Set 0 513,854.00 0.00 ITEM NOT
AND TRADITIONAL VOICE SUPPORT. RACK MOUNTABLE, CONSIDERTD ,
NORMALLY SHOULD WORK ON 230 VOLT AC. THE SYSTEM SAME WILL BE
SHOULD BE INCLUDED WIIH MDF & LSA PLUS PROCURED
DISCONNECTION MODULE, INTEGRATED PROTECTION SEPARATELY.
MODULES, 16U FLOOR MOUNTED RACK WITH WHEELS AND
OTHER REQUIRED ACCESSORIES. THE SYSTEM SHOULD
INCLUDE SEALED MAINTENANCE FREE BATTERY AS POWER
BACK UP (AT LEAST FOR 02 HOURS) IN CASE OF AC POWER
OUTAGE. THE SYSTEM SHOULD HAVE BUILT IN CHARGER
FOR CHARGING THE BATTERY.SUPPLY OF BATTERY, MDF
AND FLOOR MOUNTED 16 U RACK WITH WHEELS AND ALL
ACCESSORIES & CONSUMABLES OF THE SYSTEM IS UNDER
THE SCOPE OF THE SUPPLIER. ALL NECESSARY LICENSING
FACILITY FOR RUNNING DIFFERENT FEATURES SHOULD BE
INCLUDED IN THE SUPPLIERS SCOPE.OPERATING
ENVTRONMENT: TEMPERATURE - 5 TO 40 DEGREE C,
HUMIDITY - 10 To 90 % (NON CONDENSING). 2. IT SHOULD BE
POSSIBLE TO INTEGRATE THE SYSTEM TO NETWORK OF
DIFFERENT EXCHANGES OF DIFFERENT MAKE/
TECHNOLOGIES USING EITHER ISDN/PRI/ E-1 LINES,
ANALOG TRUNKS ETC. THE EXCHANGE SHOULD WORK ON
ANY TYPE OF PUBLIC EXCHANGE OR SIMILAR NETWORK TO
WHICH IT IS INTEGRATED /INTERFACED WITHOUT
REQUIRING ANY MODIFICATION IN THE NETWORK. 3.
CONFIGURATION: CLI BASED (FSK & DTMF) ANALOG
EXTENSION PORT: 8, CLI BASED (FSK & DTMF)DIGITAL
EXTENSION PORT: 24, CLI (FSK & DTMF) BASED ANALOG CO
TRUNK PORT: 24 (CONVERSION OF PORTS USING DTMF TO
FSK OR FSK TO DTMF CONVERTER NOT ALLOWED). SHOULD
SUPPORT'IP'EXTENSIONS. 4. DIGITAL AND ANALOG
EXTENSIONS OF THE SYSTEM SHOULD WORK OVER
STNGLE PAIR (2 CORE)0.5 MM DIA COPPER TELEPHONE
CABLE UPTO 5OO AND IOOO METERS DISTANCE
RESPECTIVELY. SYSTEM ADMINISTRATION: THROUGH
TOTAL OF TELEPHONE SOLUTION (PART-E) 266,938.00
DATA NET WORKING SYSTEM (PART-F)
1 N.S. PASSIVE COMPONENTS Make:- Legrand/ Actassi / Corning /
Siemon / Panduit
i) 15 U WALL MOUNT Network Rack
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
Wall Mounted 15 U Rack:- Supply of Fully Loaded 15 U 19"
500*600 Wall Mounted Rack with all required accessories - ,6A 6
Plug PDU-1 Nos. ,Cable Manager-2 Nos., Mounting Screws-20
Pcs ; , Pro Tek Wall Mount - 15U - 600W - 500D - Double Fan
Provision - Black Fine Tex.- 3nos , Single Fan For Wall Mount-
3nos., Metal Cable Manager - 01U - Plastic Cable Loop's
Mountable - Black Fine Tex. - Assembly Preffered , Power
Distribution Unit - 06/16 Amp Universal - 06 Socket - 16 Amp
Switch with Indicator - 06 Amp Fuse - 06/16 Amp 3 Pin Plug with
Power Cable 0.75 sq.mm 1.5 meter Length - Black Fine Tex. –
Assembly, Mounting Hardware Packet { Containg 1 Nos Each Of 3
} - 20 Set . (Make : Legrand / Net-Rack/ APW).
Cooling Fan (230V A/C 90 CFM) - 2 Nos
PDU 230VAC - 1 No,
Cable Manager Metal - 3 Nos,
Earthing Strips 150mm H - 1 No,
Mounting Hardware (20 sets of M6 screws,washer,cage nuts
(nickel coated)) - 1 No, Wall Screws (4 sets of 2'' screws,
washer,rubber grommet (nickel coated)) - 1 No,
Door Lock - 1 No
Front Metal Band -1 No
In the rack there must be maintained1 U = 1.75 inches space.
Cost of Wall Mounted 15 U Rack 2 27,613.00 55,226.00
ii) 27 U (Floor Mounted -Server Rack)
SITC of 27 U floor standing network enclosure should be
designed for servers, networking, data centres and telecom
applications. Vented top cover with fan mounting provision, front
glass or perforated metal door with lock and key. Back vented,
perforated or perforated dual metal door with lock and key. Free
floor standing design with 4 Castor wheels having 2 wheels with
brakes and 2 wheels without brakes. There should be 4 fans of
360CFM. Power distribution unit with two numbers of dual input,
vertically mounted, 230 volt, with 32amps MCB and having 25
power outputs of 6/16 amps sockets, with vertical & horizontal
cable managers. Clearance should be taken from EA before
supply of material regarding product standard, specification.
Installation of the Network Enclosure is to be done as per standard
practices in DSP and direction of EA. Transportation of the item
and supply of accessories for erection are to be done by the
contractor free of cost. Preffered makes - APW/ RITTAL/
VALRACK /Netrack
Approx. Wt.120 Kg,
CRCA 'D' grade 1.6mm thick sheet, pwoder coated for cabinet
4mm Toughened Tinted Glass Door
Along with following accessories:-
1. Cooling fan 220/230V AC, of 360 CFM-------4 Nos.
2. Cable manager Metal 4 Nos.
3. PDU- 230V /AC 1 No.
4. Cable Channel 100mm wide. 2 Nos.
5. Heavy Duty Stationary Shelf 600mm(W)X800mm(D) -1 No.
6. Mounting Hardware (20 Sets of M-6 screws, washers, cage,
nuts (Nickle Coated)- 3 Nos.
Back vented, perforated or perforated dual metal door with lock
7. Earthing strips copper 150mm H 1 No.
8. Door Lock 1 No.
9. Caster Wheels (with breake) 2 Nos. (Free Floor
Standing Design)
10. Caster Wheels (without breake) 2 Nos.
11. Front Metal Band 1 No.
12. 1 no 32 Amps DP MCB and 25 nos. power outputs of 5/15
amps sockets, with vertical & horizontal cable managers.
13. Clearance should be taken from EA before supply of material
regarding product standard,
Cost of 27 U Server Rack Set 1 84,701.00 84,701.00
iii) Patch Panel 24 Port for CAT-6A Cable:-
SITC of UTP Cat. 6A patch panels equipped with 24 RJ 45 Nos. 3 20,893.00 62,679.00
connectors 19" panel - 1U , Equipped with 4 cassettes of 6 pre-
fitted Cat. 6A LCS³ RJ 45 connectors, Automatic cassette removal
by simple pressure,Each connector can be removed
individually,T568A and B marking with colour codes,Equipped with
rear cable guide to hold cables during maintenance,Supplied with
coloured labels,Compliant with ISO/IEC 11 801, EN 50173 and
ANSI/TIA 568 standards,Flat panels,24 RJ 45 connectors - 1U -
PoE++ UTP ,Equipped with new-generation Quick-Fix for
automatic (screwless) mounting on enclosure and cabinet
uprights,Universal mounting on all cabinets or enclosures,Panels
ensure automatic earthing of each connector, equipped with 4
bundles guides fixed at the rear. (Make:-Legrand /Commscop/
iv) Supply fitting, fixing, and testing of Cat. 6A RJ 45 patch cords and Nos. 60 649.00 38,940.00
user cords ,RJ 45/RJ 45 - straight,With special “easy grip” plug
Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards, Shielded UTP, impedance 100 Ω,PVC,Length CAT6A
UTP Patch Cord - LSZH - 2mtr - Red ; Boot Both End. (User End)
(Make:-Legrand /Commscop/ RIT/Optronix.
v) Supply fitting, fixing, and testing of Cat. 6A RJ 45 patch cords and Nos. 60 424.00 25,440.00
user cords ,RJ 45/RJ 45 - straight,With special “easy grip” plug
Compliant with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards, Shielded UTP, impedance 100 Ω,PVC,Length CAT6A
UTP Patch Cord - LSZH - 2mtr - Red ; Boot Both End. (User End)
(Make:-Legrand /Commscop/ RIT/Optronix.
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
vi) Providing, fixing, fitting, connecting and testing of 2 module white Nos. 60 706.00 42,360.00
RJ 45 Cat 6A Data outlet / Toolless information outlets with white
coloured RJ-45 transparent shuttered modular scoket outlets with
front plate. ETL verified to meet or exceed TIA / EIA category 6
requirements, universal wiring label permitting to either T568A or
T568B, UL listed, and B marking with colour codes, for computer
networking complete in all respect suitable to fix in modular plate
type switch system with connections as required and Compiance
with ISO/IEC 11 801, EN 50173 and ANSI/TIA 568 standards.
(Make:- Legrand- Arteor/Scheinder- Zencelo/ Mk- Blenz)
vii) Providing, drawing, connecting and testing of 6 Core un armoured Mtr 0 136.00 -
unitube Single Mode OS2, OFC (Fiber Optics cable) from wall
mounted rack to server room Rack,i,e Rack to Rack Connectivity)
in existing heavy duty 25 mm PVC Pipe/existing Tray,for indoor
connectivity M (Make:- Legrand /Amp/ Tyco) Hanutech) (INDOOR
CONNECTIVITY) (RACK TO RACK)
viii) Providing, Laying, connecting and testing of 6 Core Armoured Mtr 150 254.00 38,100.00
unitube Single Mode OS2 OFC (Fiber Optics cable 6 F) for
Outdoor connectivity. Armored fiber Optic Cable shall be laid in
existing underground in HDPE pipes with suitable Manholes for
easy pulling and proper Maintenance and in door in existing floor
raceway. (Out Door Connectivity)
ix) Providing, fixing, connecting and testing of Modular of 24 port Each 3 12,677.00 38,031.00
loaded LIU SC- (Single Mode) type. (Make:- Legrand
/Commscop/ RIT/Molex.)
x) Providing, fixing, connecting and testing of 3 Duplex SM 9/125 SC Each 3 1,211.00 3,633.00
adapter plate. (Make : Legrand/Benden/ Commscop/Molex.
xi) Providing, fixing, fitting, connecting and testing of SC- Pigtial 1 Each 3 774.00 2,322.00
Mtr 10 GB -9/125, MM (Make:- Legrand /Commscop/ RIT
xii) Providing, fixing, fitting, connecting and testing of SC/LC duplex Each 3 2,931.00 8,793.00
Fiber Patch cords OS1/OS2 of 2 Mtrs. Length PC. . (Make:-
Legrand /Commscop/ RIT
xiii) Providing, fixing, fitting, connecting and testing of OS1/OS2 Each 10 3,382.00 33,820.00
SC/SC duplex Fiber patch cords 2 mtr, PC (Make:- Legrand
xiv) Providing, fixing, fitting, connecting and testing of Splice Tray - 24 Each 3 2,626.00 7,878.00
Fiber Capacity. Make:- Legrand /Commscop/ RIT
xv) SITC of Cat. 6A unarmoured cables for local networks, Mtr 1500 102.00 153,000.00
Performance 500 MHz, 4 pairs or 2x4 twisted pair cables, 100
Ω,Yellow RAL 1018,LSZH sheath: zero halogen. ANSI/TIA colour
code,Compliant witISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards,Products conforming to the new CPR regulation ,F/UTP
- 4 pairs,Length 500 m,Supplied on reel, :,Yellow : (to be drawn in
existing 25 mm PVC conduit or existing metal floor race way.)
Make:- Benden, Optronix, Legrand, Commscop
xvi) SITC of Cat. 6A armoured cables for local networks,Performance Mtr 2500 147.00 367,500.00
500 MHz, 4 pairs or 2x4 twisted pair cables, 100 Ω,Yellow RAL
1018,LSZH sheath: zero halogen. ANSI/TIA colour
code,Compliant witISO/IEC 11 801, EN 50173 and ANSI/TIA 568
standards,Products conforming to the new CPR regulation ,F/UTP
- 4 pairs,Length 500 m,Supplied on reel. (to be drawn in existing
25 mm PVC conduit or existing metal floor race way.) Make:-
Benden, Optronix, Legrand, Commscop
xvii) Splicing of SM/MM Fibre Optics Cable: Splicing, testing and Core 50 168.00 8,400.00
commissioning of supplied, OFC cable of 6-Core Fibre Optics
1 N.S. ACTIVE COMPONENTS
i) L2 PoE Access Switch
Supply, fitting, fixing, connecting and testing of switch with 24 x 4x10 Gbps SFP for
10/100/1000T ports and (4x10 Gbps SFP+ Port for up linking) , uplinking should be
Switching Capacity 56 Gbps and Forwarding Rate 41.7Mpps, included
Switch should support PoE and PoE+ with 370W minimum power (INDUCTED )
budget, operaating temperature 0°C to 50°C, Switch should
support link reccovery within 50ms for Ring architecture, SDN or
similar kind of technolgy should support, Warranty 5 year from
Day 1 . Make:- Cisco / Allied Telesis / Juniper)
The above L2 Managed Data Switch consists of the following:-
1. Power cord India, right angle.
2. Both side Cable connector.
3. 1 year free service pack.
Interface- 24 x 10/100/1000T ports and (4x10 Gbps SFP+ Port
for up linking)
Switching Capacity/Forwarding Rate :- 56Gbps/41.7Mpps
Performance:- Up to 16K MAC addresses, 256MB DDR SDRAM
Management:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3,
powerful centralized management and zero-touch device
installation and recovery like SDN,
Security:- Console port, GUI, Telnet, SSH,SNMPv1,2 and 3,
powerful centralized management and zero-touch device
installation and recovery like SDN,
Routing:- IPv4 static routing and RIP.
Fail-over:- Switch capable of recovery within 50ms in a ring for
application high availability
IPv6:- Device management over IPv6 networks with SNMPv6,
Telnetv6, SSHv6 and Syslogv6
Diagnostic:- Optical Digital Diagnostics Monitoring,Automatic link
flap detection and port shutdown,Port and VLAN mirroring
Sl. No. Item Code. Description DSR Amount in
Unit Qty. DSR-2022 Rate MR Rate MR Amount in Rs. Remarks
Standard Protocol:- IEEE 802.1Q,IEEE 802.1w,IEEE 802.1s,IEEE
802.1p,IEEE 802.1AB,IEEE 802.1AX,IEEE 802.3ad
Operating Temparature:- 0°C to 50°C
Certification:- EN,UL and RoHS
Warranty:- 5 Years.
Cost of L2 PoE Access Switch Set 3 209,988.00 629,964.00
.(ii) SITC of Fiber Module 1310nm 10G Base-LR SFP+ module; The Nos. 6 58,197.00 349,182.00
detailed specification in Annexure 1 of this module is a part a
necessary part of the BOQ
TOTAL OF DATA NET WORKING SYSTEM (ACTIVE & PASSIVE 1,949,969.00
COMPONENTS) (PART-F)
METAL RACE WAY (PART G)
MR Metal/GI Raceway:- SITC of following compartmental Raceways-
Metal/GI for Screed floors, Should be IP20-IK08 for distributing LV
and ELV cabling in screed floors particularly suitable for
appalications requiring EMC screening, should be pre-galvanised
sheet 275 GSM coating with thickness of 1.5 mm with bolted
construction might be combined with junction boxes or floor boxes
for wiring devices, fixing and coupler accessories, should consisit
of body and cover, cover can be fitted on to the body with screws
and can be opened easily if required as per IEC 61534-22. Make:-
Legrand, Optronix, Cope
i) 225 x 38 mm 3 compartment raceways - Data & IP-TEL, Power Mtr 30 2,605.00 78,150.00
ii) 150 x 38 mm 1 compartment raceways . Mtr 50 1,800.00 90,000.00
iii) 150 x 25 mm 1 compartment raceways . Mtr 100 1,659.00 165,900.00
iii) 100 x 25 mm 1 compartment raceways . Mtr 50 1,518.00 75,900.00
iv) 50 x 25 mm 1 compartment raceways . Mtr 50 1,235.00 61,750.00
2 MR coupler for joining metal raceways :- SITC of coupler for joining Nos. 19 120.00 2,280.00
metal raceways 38mm for Screed floors, can be fitted on to the
body of the raceways with screws. Make:- Legrand, Optronix, Cope
3 MR Bracket:- SITC of fixing bracket for metal raceways of following -
sizes for Screed floors, can be fitted on to the body of the
raceways with screws and the floor. Make:- Legrand, Optronix.,
i) 225 x 38 mm fixing bracket Nos. 26 144.00
ii) 150 x 38 mm fixing bracket Nos. 14 76.00 1,064.00
4 MR Junction Box:- SITC of Back box for Screed Floor with Screed Nos. 6 5,121.00 30,726.00
Thikness 50 mm to 70 mm , IP 44 junction boxes for tiles/marble
should Conforms to IEC/EN 60670-23 , Compatible with screed
floor system. (225x225x65-90mm) Make:- Legrand, Optronix,
5 MR Floor Box with LID & Trim for screed floor:- SITC of Floor access Nos. 17 10,497.00 178,449.00
box with LID & Trim for Tiles /Marbles Grey cover RAL 1019 for 3
compartment floor box with flexible cable exits need to installed in
backbox for screed floor system. (hi- Adjustable 225x225x65-
90mm) Make:- Legrand, Optronix, Cope
6 MR Support Plates for Floor Boxes :- SITC of Support Plates for Nos. 17 981.00 16,677.00
Floor Boxes 77 mm width waved support Plates for 4 Modules(2 x
2) -03 Nos. set for each floor Boxes. Make:- Legrand, Optronix,
TOTAL OF METAL RACE WAY (PART G) 700,896.00
TOTAL OF NON SCHEDULE ITEMS (PART B+C+D+E+F+G) 11,457,430.00
TOTAL OF SCHEDULE ITEMS & NON SCHEDULE ITEMS 14,271,591.00
(PART A+B+C+D+E+F)
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP, Durgapur
REPAIRS & RENOVATION WORKS OF EXISTING DIC BUILDING
Sl. No. Reference DESCRIPTION UNIT QTY. Amount
1 15.3 Demolishing R.C.C. work manually/ by mechanical means including stacking of
steel bars and disposal of unserviceable material within 50 metres lead as per
direction of Engineer - in- charge. Cum 13.99 3551.25 49,667.78
2 15.7.4 Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and disposal of unserviceable material within 50
metres lead as per direction of Engineer-in-charge. In cement mortar
3 15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter
including chowkhats, architrave, holdfasts etc. complete and stacking within 50
3.1 15.12.1 Of area 3 sq. metres and below Each 5.00 367.20 1,836.00
3.2 15.12.2 Of area beyond 3 sq. metres Each 5.00 502.75 2,513.75
4 15.13 Taking out doors, windows and clerestory window shutters (steel or wood)
including stacking within 50 metres lead :
4.1 15.13.1 Of area 3 sq. metres and below Each 5.00 143.50 717.50
4.2 15.13.2 Of area beyond 3 sq. metres Each 5.00 188.90 944.50
5 15.23 Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead.
5.1 15.23.2 For thickness of tiles above 25 mm and up to 40 mm Sqm 92.46 113.35 10,480.34
6 15.60 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste
materials by mechanical means, including loading, transporting, unloading to
approved municipal dumping ground or as approved by Engineer-in-charge,
beyond 50 m initial lead, for all leads including all lifts involved.
7 4.1.5 Providing and laying in position cement concrete of specified grade excluding the
cost of centering and shuttering - All work up to plinth level : 1 :3:6 (1 Cement : 3
coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate
size derived from natural sources) Cum 1.20 7294.70 8,753.64
8 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement
concrete for reinforced cement concrete work; using coarse aggregate and fine
aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland
/Portland Slag cement, admixtures in recommended proportions as per IS: 9103
to accelerate / retard setting of concrete, to improve durability and workability
without impairing strength; including pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of centering, shuttering, finishing and
reinforcement as per direction of the engineer-in-charge; for the following grades
of concrete. Note: Extra cement up to 10% of the minimum specified cement
content in design mix shall be payable separately. In case the cement content in
design mix is more than 110% of the specified minimum cement content, the
contractor shall have discretion to either re-design the mix or bear the cost of
extra cement All works above plinth level upto floor V level.
Concrete of M25 grade with minimum cement content of 330 kg /cum
9 5.9.21 Lintels, beams, plinth beams, girders, bressumers and
cantilevers with water proof ply 12 mm thick Sqm 16.50 841.95 13,892.18
10 5.22A.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete above plinth level. Thermo-
Mechanically Treated bars of grade Fe-500D or more. Kg 151.88 107.85 16,379.72
11 6.34.2 Brick work with non modular fly ash bricks conforming to IS:12894, class
designation 10 average compressive strength in super structure above plinth
level up to floor V level in : Cement mortar 1:6 (1 cement
12 13.4.2 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) Sqm 300.00 343.65 103,095.00
Sl. No. Reference DESCRIPTION UNIT QTY. Amount
13 13.11 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5
(1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster
14 9.1.1 Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash
fasteners of required dia & length (hold fast lugs or dash fastener shall be paid
for separately). Second class teak wood Cum 0.28 142949.70 39,454.12
15 10.17 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to
shape with hooked ends in R.C.C. slabs or beams during laying, including
painting the exposed portion of loop, all as per standard design complete.
TOTAL CIVIL WORKS 1,090,912.86
TOTAL 1,090,913
Construction of DIC Office Building and Modification / Renovation of Existing Office Building at SAIL-DSP,
ADDRESSABLE FIRE DETECTION & ALARM SYSTEM
SR. NO. ITEM DESCRIPTION UNIT QTY. MR RATE AMOUNT
1 Addressable SMOKE DETECTOR with base Nos. 132 2,183.00 288,156.00
2 Addressable LOOP SOUNDER/HOOTER with base Nos. 4 5,315.90 21,263.60
3 RESPONSE INDICATOR Nos. 40 112.10 4,484.00
4 Addressable 1 LOOP PANEL Nos. 2 81,272.50 162,545.00
5 Addressable MANUAL CALL POINT Nos. 4 4,106.40 16,425.60
6 1.5 X 2 Core Copper Armoured Cable Rmt. 1000 135.70 135,700.00
7 Junction Box Nos. 50 259.60 12,980.00
8 Installation, Testing & Commissioning of the system Job 1 70,800.00 70,800.00
TOTAL AMOUNT 712,354.20
TOTAL AMOUNT 712,354.20
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT 339.pdf
Tender Document
GCC Contracting PMC 2022 Am09.pdf
Tender Document
SCC.pdf
Tender Document
Technical specification.pdf
Tender Document
makes list.pdf
Tender Document
Drawing.pdf
Tender Document
BOQ SAILDSP DIC Building.pdf
Tender Document
corrigendum-2807-price.pdf
pdf • 0.21 MB
addendum-26675a6cd278-BOQDSP.pdf
pdf • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .