Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC OLD NO 338 NEW NO 17 19TH NEDUMANEHLIAN STREET G K M COLONY CHENNAI 600 082 | CHENNAI | CHENNAI | TAMIL NADU | 600082 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹5.7 L+₹1.1 L (23.3%)Rejected-Finance NO 3 JANI JAN KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹6.1 L+₹1.5 L (31.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹6.5 L+₹1.9 L (40.4%)Rejected-Finance 138A STANLEY PARK OTTUPATTARAI POST COONOOR 643 105 THE NILGIRIS TAMIL NADU | THE NILGIRIS | TAMIL NADU | 643105 | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical OLD NO 2C NEW NO 7 1 THANGAVELU VAITHIYAR STREET CORPORATION MIDDLE SCHOOL TRIPLICANE CHENNAI 600005 | CHENNAI | TAMIL NADU | 600005 | - | Rejected-Technical Rejected being related firm of M/s Sri Lakshmi Associates in terms of Note No. 14 of NIT |
Tender Value
₹7 L
EMD Value
₹14,000
Closing Date
4 Dec 2024, 6:00 pmClosed
AGE (I) NAVY CHENNAI
AGE (I) NAVY CHENNAI MILITARY ENGINEER SERVICE FORT SAINT GEORGE, RAJAJI SALAI, CHENNAI -600009
REPAIRS TO INTERNAL ELECTRIFICATION INCLUDING REPLACEMENT OF DBS, MCBS, LEDS, MCCBS, CONVERSION OF CONVENTIONAL LIGHTS INTO ENERGY SAVING LED LIGHTS AT ZONE A AND B UNDER AGE(I) NAVY CHENNAI
2024_MES_683103_1
8599/E8
Open Tender
Civil Works
Item Rate
180 days
CHENNAI
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) NAVY CHENNAI
₹14,000
Yes
29 Mar 2025
8 Nov 2024
5 Dec 2024
8 Nov 2024
4 Dec 2024
22 Nov 2024
Amount
Taking down old unserviceable copper/aluminium point wiring (light,fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc.
Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core FRLS drawn into and including non-metallic rigid PVC conduit of 20 mm dia,concealed FRLS wiring, along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof excluding Modular Metal flush box and white cover plate with frame the switches, sockets, fan regulator etc as required suitable for Modular type fitting /fixture etc witch shall be measured and paid separately all as specified and directed for :-
(a) One light point controlled by one switch
(b) One Ceiling fan/Exhaust fan point controlled by one regulator / switch.
(c)One 3 pin socket outlet 5 amps socket on independent board.
(d) One 3 pin socket outlet 5 amps socket on Same Board.
(e) One light point controlled by two Nos of two way switches.
(f) One bell/buzzer point controlled by one push button.
All as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor.
S&F Modular Socket outlet 2 in 1, 3 pin, 6A 2 Module complete all as specified and as directed.
Supply and fix Modular switch flush type single pole one way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
Supply and fix Modular switch flush type single pole two way 6 A 240 Volts complete all as specified and as directed including taking down old unserviceable switches.
Supply and fix switch Socket combination 2 in 1, 6 Amps Flush type 3 module 240 Volts complete all as specified and as directed.
Supply and fix switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 3 Module 240 Volts complete all as specified and as directed.
Supply and fix ceiling rose 3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
Supply and fix call bell Ding dong .
Supply and fix Step type electronic Modular fan regulator flush type2 Module complete all as specified and as directed.
S & F modular white cover plate with frame 3 module
S & F modular white cover plate with frame 6 module
S & F modular white cover plate with frame 8 module
S&F of Modular Metal flush box 3 Module
S&F of Modular Metal flush box 6/8 Module
Supply and fix Lamp holder PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified and directed.
S & F in repair LED light fitting 4feet,1x20w,a trendy wall mounted battern,with extrunded aluminium housing,with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make C&S ELECTRIC Or Crompton ,Cat Part NoLTTB4F20WLED/W
S&F in repair Energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser,Cat Part No SIRIUS/10W,Make C&S/ Cromption/Havells/philips.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.Make C&S Electric Or Crompton Cat Part N0:TTB2F10WLED/W
Supply and fixing in repair LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing in repair LED 7/9 watt bulb
Supply and fixing in repair LED DRIVER 35/40 watt suitable for 2 x 2 Recess type fittings
S&F for sub main wiring/power wiring with 2 runs of 4 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 4sqmm copper FRLS cable as earth lead in PVC conduit all as specified.
M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated stranded copper conducotr FRLS cable and one run of 10 sqmm copper FRLS cable as earth lead in suitanle PVC conduit all as specified.
Supply and fix Sheet metal enclousers with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed.
Supply and fix in repair MCCB three pole 415 volts 50 Hz , 63 amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed by the Engineer-in-Charge . .(Make : Havells/ABB/Standard/Legrand)
S&F in repair Double Door Vertical TPN Distribution Box 4 way complete in SS enclosure with 200 amps rated busbar.Make : Standard /Lagrant/Havells/L&T or equalent
S&F in repair MCB DB SPN 8 way complete in SS enclosure double door type with 200 amps rated busbar.
Supply and fixing repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning
(i) SP 6 To 32 AMP
(ii) SPN 32 AMP
S & F repair RCBO DP,100mA, 240 volts 63 Amps with Front face indication for earth leakage fault IP 20 protected terminals 35 sq mm terminals Sliding shutters. Complete all as specified and as directed by Engr-in-charge.Make:- Legrand Cat Part No 4113 35. or equalent Havells/L&T/C&S.
Supply and fix in repair Isolator TPN 40 Amp complete all as specified and as directed.
Supply and fix in repair Isolator TPN 63 Amp complete all as specified and as directed.
Supply only condenser 2.5 MFD complete all as specified and directed. (Make : Usha/Keltran/uptran)
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed. Notes :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Supply and Fix only new heating element of capacity 1.5KW/2KW with rubber gasket complete all as specified and directed.
Supply and fix only thermostat suitable for storage type water heater complete all as specified and directed.
Supply and only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and fix only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and fix only Apparatus plate assembly suitable to fix thermostate, heating elements as of geyser and nuts etc complete all as specified and directed.
Taking down defective unserviceable meter andSupply and fix electronic meters temper proofLCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH , Note old defective meter will be deposited in MES store
SRI LAKSHMI ASSOCIATES (BID ID -3176946)
RMK INDUSTRIES (BID ID -3175632)
shree jayam enterprises (BID ID -3179567)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .