Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
5 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SIGNAL
15 conditions · 3 needing a document upload
For works costing more than Rs.50 Lakhs:The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; where V = Advertised value of the tender in crores of Rupees. N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB in GCC APRIL 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Non submission of the above, the offer will be summarily rejected. (Ref : Advance Correction Slip No.1 dt:14/07/2022 to IRSGCC- 2022 ).
Option for Payment: An option is available that the Supplier/Contractor to take payment from Railways through Letter of Credit (LC) arrangement, having the estimated value of Rs.10 Lakhs and above. All the suppliers/contractors are requested to make use of this facility from Railways.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
"Any signal interlocking works involving EI or RRI or PI or IBS or IBH or LC gate or yard modification or UFSBI or Track circuit (AFTC or DC TC) or Axle Counter (SSDAC or MSDAC or HASSDAC) or Automatic signalling"
17 conditions · 3 needing a document upload
All the tenderers/Contractors have to deposit Earnest Money Deposit (EMD) & Tender Document Cost (TDC), in respect of e- tendering, should be accepted through net banking or payment gateway only. Fixed Deposit Receipt (FDR) will not be accepted as EMD for tenders invited on IREPS (e-tender portal). When submitted in physical form, the Tenderer shall upload scanned copies of financial instruments such as EMD, Tender form cost, mandatory credentials such as experience, turn over certificates and any other documents as applicable. All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded at the time of submission of bid S&T/SA failing which offer will be summarily rejected.
Until a formal agreement is prepared and executed, acceptance of this tender shall constitute a binding contract between us subject to modifications, as may be mutually agreed to between us and indicated in the letter of acceptance of my/our offer for this work.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions/Specifications, Schedule of Rates with all correction slips up to date for the present contract
I/We have read the various conditions to tender attached hereto and agree to abide by the said conditions
I/We also agree to keep this tender open for acceptance for a period of 60 days from the date fixed for opening the same
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
I/We have read the various conditions attached/ referred to in this tender document, and agree to abide by the said conditions.
Deployment Of Qualified Engineers At Work Sites By The Contractor. The contractor shall also employ Qualified Graduate Engineer or Qualified Diploma Holder Engineer, based on value of contract, as may be prescribed by the Ministry of Railways through separate instructions from time to time.(As per RB ltr no.2012/CE-I/CT/O/20 dt:10.05.2013)
One qualified Graduate Engineer when the cost of the work is Rs. 200 lakhs and above.
One qualified Diploma holder Engineer when the cost of the work 9.1.1 to be executed is more than Rs.25 lakhs but less than Rs.200 lakhs.
In case the contractor fails to employ the technical staff as aforesaid, he shall be liable to pay a an amount of Rs.40,000/ (Rupees Forty thousand) for each month or part thereof for the 9.1.2 default incase of Graduate Engineer and Rs.25,000/- (Rupees Twenty five thousand) for each month or part thereof for the default in case of Diploma holder (Engineer)
In case of more than one L-1 bidders, tender may be awarded to tenderer having higher Bid Capacity. In case Bid Capacity is also the same, tenderer having done more value of similar work in last three previous financial years and the current financial year upto the date of opening of the tender, may be selected for the award. Instructions with respect to Bid Capacity will follow.
All the contracts on works/goods/services will be subject to the new GST act as applicable from time to time. Contractors have to register themselves with GST authorities and to furnish the GST registration number in order to process the bills from 01.7.2017
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/WE also hereby agree to abide by the INDIAN RAILWAY GENERAL CONDITIONS OF CONTRACT- APRIL 2022, with all correction slips up to date and to carry out the works accordingly.
In the e-tendering process, it is mandatory that every tenderer/contractor/firm registered with WWW.IREPS.GOV.IN to submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number
Salem Division-Development of existing ballast depots at Uttukuli (UKL) & Mallur (MALR).
SA-SG-120-I-OT-13-2026~SR
SA-SG-120-I-OT-13-2026
Open
Works - General
12 Months
Salem, Tamil Nadu
₹0
₹2.1 L
13 Oct 2026
13 Oct 2026
22 Oct 2026
84 items across 2 schedules · ₹91,95,924.47 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | " Te s t i n g a n d commissioning t h e RRI/PI signalling installations jointly with the Railway representative at site at the stations/ LC gates c o v e r e d u n d e r various schedules of the Contract and ensuring that all t h e signalling gears a r e installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, b l o c k joints, route cancellation, r e l a y r o o m k e y entries, block instrument key , earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)." a)Testing and commissioning of stations (upto 5 roads) | Station 1.00 | — | 38,884.69 | 38,884.69 |
| 2 | " Te s t i n g a n d commissioning t h e RRI/PI signalling installations jointly with the Railway representative at site at the stations/ LC gates c o v e r e d u n d e r various schedules of the Contract and ensuring that all t h e signalling gears a r e installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, b l o c k joints, route cancellation, r e l a y r o o m k e y entries, block instrument key , earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule)."Testing and commissioning of stations (more than 5 roads) | Station 1.00 | — | 67,941.71 | 67,941.71 |
| 3 | "Submission of all relevent final 'As mades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. Onapproval 8 copies shall be made for As-made circuit diagrams also as mentioned above" | Sheet 250.00 | — | 382.12 | 95,530 |
| 4 | Wiring o f Relay Inputs t o Wa g o B l o c k and Wago block to Datalogger. Necessary Wagos required is included as per schedule | Per Unit 200.00 | — | 285.86 | 57,172 |
| 5 | Wiring of Analog Voltages from IPS Room to Datalogger. Necessary W a g o s r e q u i r e d is included as per schedule | Numbers 40.00 | — | 285.86 | 11,434.4 |
| 6 | Provision of earth electrodes as per drawing No.SG/CN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, M sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 40.00 | — | 1,707.55 | 68,302 |
| 7 | Supply of Low maintenance secondary cells of t h e f o l l o w i n g c a p a c i t i e s w i t h necessary inspection a s p e r specification/ drawing/ description enclosed in this document.b)Supply o f Secondary cells - 2V- 80AH capacity | Numbers 30.00 | — | 3,379.2 | 1,01,376 |
| 8 | Supply of track feed battery charger IRS:S 89- 2013 | Numbers 10.00 | — | 4,375.25 | 43,752.5 |
| 9 | Supply of 'B type choke IRS:S 65-83 | Numbers 20.00 | — | 2,855.6 | 57,112 |
| 10 | Supply a n d provision o f normal j o i n t using Thermo shrink jointing k i t ( R D S O s p e c s No TC/77/2012 ( Rev.3) with amendment No.1&2 o r latest.& jointing k i t t o be inspected by RDSO) f o r 4 / 6 qua d cable normal joint. The work includes excavation of joint p i t o f size 1mX1.5mX1.5m and closing t h e s a m e after completion of cable joint as per the instruction of Railway representative at site. | Numbers 20.00 | — | 4,628.91 | 92,578.2 |
| 11 | S u p p l y a n d installation o f 2 4 Fi b r e Joint enclosure f o r armoured optical fi b r e cable c o n f o r m i n g t o RDSO spec.RDSO/SPN/TC/68/2014 rev2.0 or latest | Numbers 8.00 | — | 13,647.37 | 1,09,178.96 |
| 12 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule) | Metre 3000.00 | — | 64.1 | 1,92,300 |
| 13 | Excavation of cable trench in all kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 0.5 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this schedule.) | Metre 750.00 | — | 32.05 | 24,037.5 |
| 14 | Removing/breaking of existing RCC slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating i t a s p e r t h e instructions of Railway Representatives a t s i t e . (Laying of cables is not included in this schedule). | Metre 100.00 | — | 314.41 | 31,441 |
| 15 | Excavation of trench to a depth of 1 Mtr. for track crossing of cables, refilling of trench by ramming a n d consolidating i t a s p e r the instructions of Railway representative at site a f t e r l a y i n g o f D W C / RC C p i p e s . During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall b e f r o m t h e b o t t o m o f sleepers for track crossings. Laying o f cables and DWC pipes is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre 240.00 | — | 385.45 | 92,508 |
| 16 | Excavation of trench to a depth of 1 Mtr. for road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench b y r a m m i n g a n d consolidating i t and resurfacing it to the original position. Laying of cables is not included in this schedule. (Supply of DWC/RCC pipes with couplers/collars is not included in this schedule). | Metre 30.00 | — | 501.03 | 15,030.9 |
| 17 | Provision of GI pipes (50/100mm dia) for cable laying with offset at both ends and with couplings over RCC bridges, drainage, culverts, and girder bridges. For RCC bridges, drainage, and culverts, the pipes shall be mounted on concrete masonry supports of size 300mm x 300mm x 300mm at an interval of 2 meters. For girder bridges, the pipes shall be fixed on suitable MS clamps at an interval of 2 meters. The ends of the pipes shall be closed with brick masonry abutments to ensure that no cable is exposed. The work shall be carried out as per the instructions of the Railway representative at the site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).Stone jelly (20/25mm size), bricks, sand, cement, MS angles, flats, bolts, nuts for manufacturing and fixing clamps, bricks, M sand, cement, and other miscellaneous materials for the work shall be supplied by the contractor. | Metre 300.00 | — | 208.54 | 62,562 |
| 18 | Provision of GI pipes (50/100mm dia) for cable laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with b r i c k masonry abutments work so that no cable is exposed, The work shall be carried out a s p e r the instructions of Railway representative at site.(Supply of GI pipes with couplings and laying of cables is not included in this schedule).[Stone jelly of size 20/25mm, bricks, sand, cement, a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Metre 250.00 | — | 182.87 | 45,717.5 |
| 19 | Laying o f signaling/power/ telecommunication cables a s p e r cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply o f cables i s n o t included in this schedule). | Metre 16500.00 | — | 18.18 | 2,99,970 |
| 20 | "Refilling of cable trench 1m depth by 0.3m width throughout, with earth after laying of c a b l e s , a n d consolidating t h e t r e n c h by ramming and levelling." | Metre 3000.00 | — | 15.4 | 46,200 |
| 21 | "Refilling of cable trench 0.5m depth by 0.3m width throughout, w ith earth after laying of cables, and consolidating the trench by ramming and leveling." | Metre 750.00 | — | 7.77 | 5,827.5 |
| 22 | "Digging of pit to a depth of 800mm of size 300mmX300mm, c a s t i n g o f concrete foundation o f s i z e 300mmX300mmX300mm and Placing of RCC cable markers on top of t h e foundation a n d r e fi l l i n g t h e p i t and consolidating i t b y r a m m i n g . T h e cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside statio n l i m i t s throughout t h e cable route, diversions a n d a l s o a t every track/road crossing." | Numbers 75.00 | — | 123.35 | 9,251.25 |
| 23 | " R o a d c r o s s i n g / Tr a c k C r o s s i n g through Horizontal Drilling at approximately depth of 1.5 to 2 m below t h e formation level of the earth including insertion of HDPE pipe/DWC pipe along with couplers, drawl of cable (or) direct drawl of cables etc. (Note: The pilot used for HDD should be of sufficient size to suit insertion o f HDPE /DWC pipe o f size 120mm (outer dia.) or direct drawl of three cables (Signalling/Power/Quad/OFC) or three nos.of 40mm dia HDPE pipe or any other combination a s directed b y t h e site engineer) ( Supply of HDPE pipe is not covered in this schedule)" | Metre 60.00 | — | 1,351.45 | 81,087 |
| 24 | B l o w i n g / D r a w i n g o f O F C cable/Power cable/Signalling cable inside permanently solid lubricated HDPE Pipe already laid. This work includes necessary duct integrity test for solid l u b r i c a t e d H D P E p i p e . ( This includes Transportation o f materials from nominated stores to site) | Metre 2000.00 | — | 23.43 | 46,860 |
| 25 | Supply of Main LED Signal Aspect - Yellow as per RDSO Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers 3.00 | — | 8,850 | 26,550 |
| 26 | Supply of Main LED Signal Aspect - Red as per R D S O Specifications RDSO/SPN/199/2010 Rev1.1 or latest | Numbers 3.00 | — | 9,233.5 | 27,700.5 |
| 27 | Supply of subsidiary Signal Aspect - Shunt LED as per RDSO Specification SPECIFICATION NO. RDSO/SPN/153/2023 Revision 5.0 or latest | Numbers 18.00 | — | 5,740.7 | 1,03,332.6 |
| 28 | Supply of Colour light Signal pole 140mm dia, 4.6m/ 3.6m tall with necessary inspection as p e r s p e c i fi c a t i o n / drawing/ description enclosed in this document. b)Supply o f colour light Signal pole 3 .6 m tall and 140 mm dia (Galvanised) | Numbers 3.00 | — | 4,737.7 | 14,213.1 |
| 29 | Supply of Ground type shunt signal - complete with surface base, signal pole, hood etc., with necessary inspection as per specification/ d r a w i n g / d e s c r i p t i o n enclosed in this document. | Numbers 6.00 | — | 7,463.5 | 44,781 |
| 30 | Supply of KLCR relays 24V, ACI (Supply of Key Lock Checking Relay (KLCR) with one number K-50 neutral Relay to work on 24V DC non AC immunized a s p e r specification No.RDSO/SPN/219/2016 Ver 1.0 with Amdt- 1 o r latest (with one extra ward plate and with case) contact configuration-4F/4B and as per IRS:S-23, IRS:S@58"44@ IRS:46 or latest. | Numbers 5.00 | — | 10,722.72 | 53,613.6 |
| 31 | Supply of lamp proving relays(QECX-61) for a)LED aspects w ith p l u g boards, connectors and retaining clips with necessary inspection as per specification/ | Numbers 12.00 | — | 5,901.5 | 70,818 |
| 32 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n t y p e a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm coppe r, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. a)Wiring of Signal/ point/ LC control circuit (up to 4 relays/Plug in type) | Set 4.00 | — | 4,945.51 | 19,782.04 |
| 33 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n t y p e a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm coppe r, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. b)Wiring o f Signal/ Point/ L C control circuit (up to 8 relays/plug in type) | Set 7.00 | — | 8,786.26 | 61,503.82 |
| 34 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n t y p e a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm coppe r, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. c)Wiring o f Signal/ Point/ L C control circuit (up to 12 relays/plug in type) | Set 5.00 | — | 11,355.02 | 56,775.1 |
| 35 | Manufacture and supply of M.S. relay frames of suitable size to hold up to 4/ 8/ 12/ 2 0 relays /plug i n t y p e a s required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.[Wire PVC copper, 3/0.75mm and 16/0.2mm coppe r, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, M S fl a t s 2 5 m m x 6 m m brass bolts a n d nuts, paints, soldering materials, resistors, condensers a n d a l l other miscellaneous materials required for the work shall be supplied by the contractor]. d)Wiring o f Signal/ Point/ L C control circuit (up to 20 relays/Plug in type) | Set 8.00 | — | 13,597.41 | 1,08,779.28 |
| 36 | Fabrication and Supply of box suitable for 4 Nos of KLCRs | Numbers 1.00 | — | 15,009.6 | 15,009.6 |
| 37 | Fixing o f PBT terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram b o a r d u s i n g plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rac k shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 6 0 m m centers a n d P B T Fu s e blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, o t h e r fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. a)Fixing of PBT terminal blocks (25mm/60mm centre) and termination (Per Unit = Per Terminal Block) | Per Unit 350.00 | — | 167.99 | 58,796.5 |
| 38 | Fixing o f PBT terminal block/ P B T fuse block, rubber grommets, clamping of cables using teakwood c a b l e c l a m p s a n d base planks, termination o f cables, provision of ND type f u s e s o f required capacities, provision of copper b u s b a r f o r supply terminals, wiring, provision o f termination particulars diagram b o a r d u s i n g plywood of thickness 1 2 m m - teakwood finish o f size 1800mm x 1200mm with Aluminium grooved channel frame i n the relay room. The blank spaces over the top of the cable termination rac k shall b e covered with phynolic s h e e t o f t h i c k n e s s 3mm wherever required. The termination and cable core particulars shall b e painted o n t h e PVC/ n y l o n s l e e v e s . T h e w o r k a l s o includes identification of cables using aluminium tags provided on each cable with letters punched neatly.(Supply of PBT terminal blocks 25mm & 6 0 m m centers a n d P B T Fu s e blocks i s not covered in the schedule) [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, o t h e r fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50mm for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel f r a m e , phynolic s h e e t 3 m m thick, paint a n d a l l other miscellaneous materials shall be supplied by the Contractor]. b)Termination using P B T fuse block i n cable termination rack (Per Unit = Per Fuse Block) | Per Unit 50.00 | — | 201.27 | 10,063.5 |
| 39 | Concreting and erection of Relay racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply o f relay rack is n o t covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, p a i n t a n d all other miscellaneous materials required for the work s h a l l b e s u p p l i e d b y the Contractor]. a)Concreting and erection of relay rack - 168 capacity | Numbers 1.00 | — | 6,818.18 | 6,818.18 |
| 40 | Concreting and erection of Relay racks- 168/56 relay capacity using 'J' type bolts and painting of relay rack as per the instructions of Railway representative at site.(Supply o f relay rack is n o t covered i n this schedule).['J' type bolts and nuts with washers, nylon bushes, concreting materials, p a i n t a n d all other miscellaneous materials required for the work s h a l l b e s u p p l i e d b y the Contractor]. b)Concreting a n d erection o f relay rack - 56 capacity | Numbers 1.00 | — | 3,015.04 | 3,015.04 |
| 41 | Fixing of plug boards, 5 0 way terminal blocks with 2BA terminals, and wiring of relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Suitable wire supporting tray with cover made of PVC shall be provided horizontally and vertically in the relay racks.. While running the wires on the aluminium ladder proper care shall be taken t o provide smooth materials like rubber beading in the openings on Phynolic sheets, to avoid damage to wires. The work also includes wiring of contacts for data logger and terminating them i n tag blocks, provision of relay index board. (Supply of relays, plug boards, connectors and retaining clips is not covered in this schedule). [Wire PVC 16/0.2mm copper, t a g blocks, 2BA terminals, hard wood plank o f size 600mmx 900mmx25mm with decolum finish, MS angles of size 25mmX25mmX6mm, relay fixing bolts and nuts, teakwood plank 25mm thick for fixing resistors and condensers, phynolic sheet 6 m m t h i c k o f s i z e 1200mmX1800mm with aluminium grooved channel frame f o r relay i n d e x b o a r d , p a i n t s , s o l d e r i n g materials, b u n c h i n g t h r e a d , w i r e w o u n d resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay 105.00 | — | 1,045.76 | 1,09,804.8 |
| 42 | Fixing o f additional p l u g boards, 5 0 ways terminal blocks and wiring of additional relays as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply o f r e l a y s , plug boards, connectors and retaining clips and 50 w a y terminal boards i s n o t covered i n this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood p l a n k 2 5 m m t h i c k for fi x i n g resistors a n d condensers, soldering m ateria ls, b u n c h i n g t h r e a d , w i r e wound resistance, condenser, w i r e supporting tray with cover of suitable size made of PVC, paint, varnish a n d a l l other miscellaneousmaterials required for the work shall be supplied by the Contractor ] | Per Relay 60.00 | — | 726.5 | 43,590 |
| 43 | Carrying out alterations t o the existing relays in the relay racks/apparatus cases as per the approved circuit diagram using wire PVC 16/0.2mm copper. The work includes painting alterations and releasing the unwanted wires c a r e f u l l y w i t h o u t disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering m ateria ls, b u n c h i n g t h r e a d s , condensers, resistances a n d teakwood p l a n k f o r fixing the m a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. | Per Relay 150.00 | — | 695.67 | 1,04,350.5 |
| 44 | Supply and laying of PVC Warning Tape colour Orange, width of 250mm (10") by printing with b l a c k l e t t e r s 'Indian RailwaySignal/Telecom/OFC Cable' on both sides | Metre 3750.00 | — | 46.15 | 1,73,062.5 |
| 45 | Supply of HDPE Pipe 40mm (outer dia)/33 mm (inner dia) with couplers | Metre 2000.00 | — | 60.93 | 1,21,860 |
| 46 | Supply of Track Feed Resistance | Numbers 10.00 | — | 287.77 | 2,877.7 |
| 47 | Excavation of pit, erection of cable termination boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long a t the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each p i p e for c a b l e e n t r y a n d o n e G I pipe 150mm long 32mm dia for drawl of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes i n s i d e and outside w ith o n e coa t of red-oxide a n d two coats of aluminium paints. | Numbers 13.00 | — | 5,029.69 | 65,385.97 |
| 48 | Installation of combined type point machine- I R S t y p e a n d c o n n e c t i n g a l l ground connections including wiring and termination i n p o i n t m a c h i n e a n d interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire a n d painting. This work includes provision of insulation to stretcher bars, throw b a r l u g a n d "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat w i r e P V C 7/1.4mm copper, P V C h o p e p i p e , paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 13.00 | — | 16,383.88 | 2,12,990.44 |
| 49 | Excavation o f pit,casting concrete foundation as per Drg.No.SG/CN/02/9 using metallic templates, for erection o f colour light signals up to 4 aspects.[Foundation bolts, cement, M sand, stone jelly o f size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 3.00 | — | 9,213.28 | 27,639.84 |
| 50 | " E r e c t i o n o f s u r f a c e b a s e , s i g n a l pole, mounting of colour light signal up to 4 aspects complete o n Signal pole/ Off-set bracket, (for LED / filament bulbs) with lenses, triple pole l a m p holder, filament switching u n i t s , CLS transformer, current regulators (whichever is applicable), fixing of ladder w i t h platform complete and concreting of ladder shoe, fixing o f number plates, marker board, lens guard, fi x i n g of speed l i m i t b o a r d wherever necessary, termination of tail cables, wiring of signal unit w ith P V C w ire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down.(Supply of surface base, Offset bracket, CLS pole, C L S aspects complete, ladder with shoes and platform, Speed limit board, LED aspects, current regulators, l a m p holders, lamps, filament switching u n i t a n d CLS transformer is not covered in this schedule).['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, M sand, Signal Collar Rings, wire P V C 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, E W S l o c k s , a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers 3.00 | — | 8,287.08 | 24,861.24 |
| 51 | "Excavation o f p i t a n d c a s t i n g concrete foundation a s per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal. [Foundation bolts and nuts, cement, M sand, stone j e l l y o f size 2 0 / 2 5 m m a n d a l l other miscellaneous materials for the work shall be supplied by the Contractor]." | Numbers 6.00 | — | 4,645.17 | 27,871.02 |
| 52 | " E r e c t i o n o f G r o u n d t y p e s h u n t signal complete including surface base, signal pole, L E D a s p e c t s / l e n s e s , b u l b s w i t h holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision o f E W S locks and painting o f one coat of red oxide and two coats of Aluminium/ enamel paint.(Supply o f Ground t y p e shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered i n t h i s schedule).[Wire PVC 3/0.75mm copper, l e n s guards, E W S locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor]." | Numbers 6.00 | — | 3,170.44 | 19,022.64 |
| 53 | Provision of DC Single/ Double rail track circuit to suit RE/ Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 No's for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, 'B' type choke' and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, 'B' type choke, track relays, un-charged secondary cells (2V - 80AH), TLD boxes with stumps,2cX2.5 sq.mm cable, is not covered in this schedule). a)Provision of track circuit in RE/Non RE area (point zone) | Numbers 10.00 | — | 8,914.5 | 89,145 |
| 54 | Alteration to existing DC Track Circuits to suit RE/Non RE standard as per approved signaling plan. This w ork includes provision of double bonding a n d parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable. a)Alteration to existing track circuits at feed end | Numbers 10.00 | — | 4,234.65 | 42,346.5 |
| 55 | Alteration to existing DC Track Circuits to suit RE/Non RE standard as per approved signaling plan. This w ork includes provision of double bonding a n d parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable b)Alteration to existing track circuits at relay end | Numbers 10.00 | — | 3,850.31 | 38,503.1 |
| 56 | Excavation of pit, casting concrete foundation and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & n u t s , 'E' type locks, cement, M sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required f o r thework shall be supplied by the Contractor.] | Numbers 15.00 | — | 11,333.1 | 1,69,996.5 |
| 57 | "Excavation of pit, casting concrete foundation and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for t h e front door and latching arrangement for the back door, and fixing o f o n e hardwood s h e l f p l a n k 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, M sand, stone jelly of size 20/25mm,37mm hard wood planks, latching ""arrangements, paints, varnish, fixing bolts & nuts a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]""" | Numbers 10.00 | — | 8,787.04 | 87,870.4 |
| 58 | Termination o f n e w main/tail cables o n the existing terminals/ fuse blocks in apparatus c a s e s / b a t t e r y b o x e s / C T b o x e s / cable termination r a c k s a s p e r approved circuit diagram. T h e terminal particulars a r e to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry o f n e w cables i n the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks w i t h cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, M sand and all other required miscellaneous materials shall be supplied by the contractor].(Per Unit = Per Terminal block) | Per Unit 850.00 | — | 73.59 | 62,551.5 |
| 59 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay r o o m . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level a n d t h e bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." a)Termination o n 25/60mm PBT terminals (new location)(Phynolic sheet)(Per Unit = Per Terminal block) | Per Unit 1500.00 | — | 172.14 | 2,58,210 |
| 60 | Termination of main, tail, Signaling and power cables a n d internal wiring on terminal/ fuse b l o c k s i n n e w apparatus cases, cable termination b o x e s a n d i n gate Lodges excluding c a b l e termination r a c k at relay r o o m . The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing o f Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks o n t h e terminal board, drilling of necessary h o l e s , termination of cables, wiring, identification o f cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting of particulars on sleeves andalso o n t h e inner side o f t h e doors of apparatus cases. After terminations are "over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level a n d t h e bottom surface shall b e sealed with sealing compound.(Supply of PBT terminals and Fuse blocks is not c o v e r e d i n this schedule)." b)Termination o n P B T fuse block (new location) (Phynolic sheet)(Per Unit = Per Fuse block) | Per Unit 50.00 | — | 209.93 | 10,496.5 |
| 61 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level a n d t h e bottom surface shall b e sealed with sealing compound. a)Termination of cables on 25/60mm PBT terminals (existing location)(Per Unit = Per Terminal block) | Per Unit 500.00 | — | 151.09 | 75,545 |
| 62 | Termination of main, tail, Signaling and power cables and internal wiring b y fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp o n teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, a s p e r approved circuit diagram a n d cable plan, painting o f particulars o n sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, t h e side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with M sand up to base level a n d t h e bottom surface shall b e sealed with sealing compound. b)Termination of cables on P B T fuse block (existing location)(Per Unit = Per Fuse block) | Per Unit 50.00 | — | 188.86 | 9,443 |
| 63 | Installation of charged secondary cells of the f o l l o w i n g c a p a c i t i e s i n a p p a r a t u s cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases.(Supply of secondary cells is not included in this schedule).[Wire PVC 3/0.75mm copper, connecting strips, paint a n d a l l other miscellaneous materials required for the work shall be supplied by the Contractor]. b)Installation of 2V-40/80AH cells in apparatus cases(Per Unit = Per Cell) | Per Unit 30.00 | — | 491.59 | 14,747.7 |
| 64 | Carrying out alterations to the existing SM's control panel. T h e w o r k includes drilling of holes o n t h e To p p l a t e wherever required, fixing and wiring o f knobs, buttons, counters, LEDs with holder, closing of unwanted holes, carrying out painting alterations on the panel, termination of additional cables and carrying out alteration to the existing wiring as per approved circuit diagram, releasing of unused wires, and painting of particulars as per the instructions of Railway representative at site. (Supply of knobs, buttons and counters is not included in the scope of this schedule). [LED lamps with holder, paint, soldering materials and all other miscellaneous materials required f o r t h e w o r k s h a l l be supplied by the Contractor]. | Lumpsum 2.00 | — | 15,967.35 | 31,934.7 |
| 65 | Provision of signaling arrangement during Non-Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site.(Supply of relay rack, relays, and SM slide instrument is not included in this schedule).[All other miscellaneous materials required for the work shall be supplied by the Contractor]. | Station 2.00 | — | 33,631.06 | 67,262.12 |
| 66 | Casting concrete foundation and erection and painting of boards with 'LEGEND' such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this schedule. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, M sand, cement, M.S.flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. | Numbers 2.00 | — | 3,972.14 | 7,944.28 |
| 67 | Provision of HDPE Pipe of dia 40/33 mm | Metre 2000.00 | — | 26.11 | 52,220 |
| 68 | L a y i n g o f DWC/Split D W C P i p e s f o r Track Crossing/Road Cutting/Trenches | Metre 3000.00 | — | 42.46 | 1,27,380 |
| 69 | "Breaking of concrete and releasing of STOP board/Warning board/ LEGEND boards along w i t h r a i l s , accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. Also the resultant pits s h a l l b e re-surfaced a n d consolidating by ramming and levelling" | Numbers 2.00 | — | 1,580.36 | 3,160.72 |
| 70 | Releasing of existing point lay-out with facing point lock,split stretchers, electrical detector, l o c k bars, point/trap indicators cranks, rods e t c . , carefully without D a m a g i n g the materials, accounting a n d s t a c k i n g them neatly a t a place as instructed by Railway representative at site. | Set 4.00 | — | 2,852.7 | 11,410.8 |
| 71 | Releasing o f existing apparatus cases (Full/ H a l f / Q u a r t e r s i z e ) w i t h o u t d a m a g e after releasing the shelf planks, Terminal blocks, Fu s e Blocks, Terminal Boards, Relays o f all t y p e s E K T s , S e c o n d a r y Cells, power equipments, 'E' type locks, etc., and breaking t h e concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials s h a l l b e accounted and stacked a t a place a s instructed by Railway representative at site. | Numbers 15.00 | — | 3,006.71 | 45,100.65 |
| 72 | Breaking of concrete and releasing the existing cable termination boxes, after releasing the b a s e p l a n k , Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing t h e resultant p i t s and consolidating i t by ramming and levelling. The released materials shall b e accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 8.00 | — | 2,004.94 | 16,039.52 |
| 73 | Dismantling and releasing of existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work i n c l u d e s b r e a k i n g t h e concrete foundation,closing t h e r e s u l t a n t p i t and resurfacing it by ramming and levelling. | Numbers 3.00 | — | 3,083.03 | 9,249.09 |
| 74 | Dismantling a n d releasing o f existing Point m a c h i n e s ( a l l t y p e s ) i n c l u d i n g ground connections a n d other accessories available complete without any damage to the gadgets, accounting a n d stacking them neatly a t a place a s instructed b y Railway representative at site. | Numbers 4.00 | — | 2,698.69 | 10,794.76 |
| 75 | "Releasing o f existing g r o u n d t y p e shunt signals along with surface base, signal post etc carefully without any damage, accounting a n d stacking t h e m n e a t l y a t a place as instructed b y Railway representative a t site. The work also includes breaking and removal o f concrete foundation a n d refilling o f the resultant pit by ramming and levelling." | Numbers 1.00 | — | 2,196.41 | 2,196.41 |
| 76 | Releasing of existing TLD boxes with stumps a n d terminals a f t e r releasing a l l t h e bond w i r e s . T h e r e l e a s e d m a t e r i a l s s h a l l be accounted and stacked neatly at a place as instructed by Railway representative at site. | Numbers 30.00 | — | 159.29 | 4,778.7 |
| 77 | Protection adjustments and re-instating of S&T gears by deputation of Helpers/Unskilled Labour for executing additional S&T portion of t h e w o r k s . The work can involve fixing, releasing, dismantling, replacement,excavation, clearing of vegetation, loading and unloadingof material and assisting skilled persons etc as per instruction of Railway representative. | Man- 60.00 Days | — | 847.59 | 50,855.4 |
| 78 | Protection, adjustment and reinstating of S&T g e a r s b y d e p u t a t i o n of Fitter/Wireman/Painter/Welder/ Mason/Cable Jointer (Skilled Labour or Technician ) etc., for executing additional S&T portion of works. The work can involve fixing, releasing, dismantling, replacement, painting or alteration o f various signallilng assets or parts, termination of cables, m i n o r patch work on damages at location box, Plastering, Concreting brick work, wiring alterations, cable jointing e t c as p e r instruction of Railway representatives at size. | Man- 30.00 Days | — | 1,073.45 | 32,203.5 |
| 79 | Transportation of Signalling materials by road a s p e r t h e i n s t r u c t i o n s o f Railway representative at site. The work also includes l o a d i n g a n d u n lo a d in g o f the materials a)Transportation o f Signalling materials upto 100kms | MT-Km 1000.00 | — | 22.75 | 22,750 |
| 80 | Transportation o f Signalling materials more than 100km | MT-Km 500.00 | — | 13.91 | 6,955 |
| 81 | Engaging mechanical excavators like JCB or other machineries for regarding and levelling t h e formation, dismantling a n y infringing structures, clearing and removing debris etc., with all leads and lifts etc., complete and as p e r t h e instruction o f Railway representative at site. | Hour 20.00 | — | 1,202.5 | 24,050 |
| Schedule total | ₹46,96,064.47 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-APRIL-2022.pdf
ATTACHMENT
GCCCorrectionSlip1to11_comp.pdf Correction slip
ATTACHMENT
LetterofCreditRBLr_1.pdf
ATTACHMENT
PoliceVerification1.pdf
ATTACHMENT
ModelformofBankGuarantee.pdf
ATTACHMENT
JPODETAILS.pdf
ATTACHMENT
Labourclause.pdf
ATTACHMENT
TenderDocumentfinal.pdf
ATTACHMENT
GCCCorrectionSlip1to11_comp.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .