Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 685 SONARPUR STATION ROAD GREEN PARK KOLKATA 700103 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700103 | L1 | Accepted-AOC Quoted rate found Lowest (L1). | |
| 2 | L2₹12.0 L+₹3.2 L (36.0%)Rejected-Finance | L2 | Rejected-Finance Quoted rate found 2nd Lowest (L2). | |
| 3 | L3₹13.2 L+₹4.3 L (49.1%)Rejected-Finance 26 1 BRINDABAN PAL LANE BAGBAZAR KOLKATA 700003 | KOLKATA | KOLKATA | WEST BENGAL | 700003 | L3 | Rejected-Finance Quoted rate found 3rd Lowest (L3). | |
| 4 | L4₹13.8 L+₹4.9 L (56.0%)Rejected-Finance VILL DAKSHIN SHIBGANJ P O AND P S PATHARPRATIMA DIST SOUTH 24 PARGANAS | SOUTH 24 PARGANAS | WEST BENGAL | L4 | Rejected-Finance Quoted rate found 4th Lowest (L4). |
Tender Value
Refer Docs
EMD Value
₹17,700
Closing Date
16 Dec 2024, 3:00 pmClosed
EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION
O/O THE EXECUTIVE ENGINEER PWD MALDA ELECTRICAL DIVISION Singatala Malda PIN 732101
Necessary replacement of Batteries of 3 x 30 KVA UPS installed at Radiotherapy Building in Malda Medical College and Hospital, Malda. (Electrical Work)
2024_WBPWD_778328_1
WBPWD/EE/MED/e-NIQ-42/2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Malda
Please refer Tender documents.
6 documents required · 6 mandatory
₹17,700
7 Mar 2025
3 Dec 2024
18 Dec 2024
4 Dec 2024
16 Dec 2024
10 Dec 2024
Amount
Supply, Installation, Testing & Commissioning of 30 KVA UPS 3 phase input & 3 phase out put on line UPS systems [Make: Avo / Scheinder / VERTIB / APC] -
Topology, IGBT BASED DSP CONTROLED
Rating of UPS(KVA/KW): 30KVA / 24 KW .
Input Voltage: 360 ---- 460 VAC
Input Frequency: 45 to 55 Hz
Isolation Transformer: Inbuilt Isolation Transformer with 1:1 ratio at UPS Output to be provided .
Back feed Protection: UPS should have back feed protection
DC Ripple: Residual ripple Voltage should be <1%
Charging: Autometic float cum Boots Charging Capability with setteble flote & boost charging voltages and current levels and boots charger timer
Output Voltage: 400 V AC
Output Voltage Regulation: Static Variation +/_ 1% and Dynamic variation +/-3%
Output Frequency: 50 Hz +/- 0.1%
Output Power Factor: 0.8
Crest Factor: 3:1
THDu: < 1% (linear load), < 5%(non linear load)
Waveform: Pure Sine Wave
Overload: 110% for 10 minutes, 125% for 3 minutes, 150% for 30 sec.
Static By Pass: 100 % rated static switches with fuse protection overload on Bypass: 100% for 10 ms
Overall Efficiency: >90%
Battary Cabine: With power coated MS angle with MS sheet suiteble dimention and gadge, well air ventilation to ensure the battery optimum life cycle.Useing Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress.
Battery : 12 V, Mono Block batteries
DC Bus : Minimum 360 V or above
Protections: Input & Output Over / Under Voltage, Single Phasing , DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recovery
Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
Metering: Graphical LCD display for Input & Output - Voltage, Current & Frequency, Battery - Voltage & Current
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
Switchgear: MCB / MCCB for Input, Battery, Output & Manual Bypass Switch
Termination: Input, Battery, Output & Bypass
Enclosure: IP 20
Operating Temp: 0 to 40 Deg C
Humidity: Upto 95% Rh (non-condensing)
Cooling: Forced Air
Noise: < 55 dB
Cold Start : Provided
Communication: RS 232, RS 485,
Monitoring Software: UPS Monitoring Software on Windows XP Platform
Certification : ISO 9001: 2015, ISO 14001: 2015, ISO 45001:2018,ISO 50001;2018 , ISO:20000-1:2011,ISO:27001:2013, ROHS
CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
Warranty: Minimum period of 2 Years
SITC of 12 Volt / 42 AH SMF Battery-Exide/Amaron Quanta using necessary dc connecting cables.Warranty: Minimum period of 2 Years.
Less cost of Lumpsum amount for old dismantled unserviceable UPS and Batteries.
TERMS & CONDITIONS
(i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST. (ii) All materials, equipments & accessories must conform to relevant IS / IEC specifications. (iii) Necessary manufacturer's warranty certificate will have to be submitted during delivery of the material.
Rajalakshmi Enterprise (BID ID -5847014)
Teknet Consultancy (BID ID -5844832)
B. ENGINEERING CO. (BID ID -5850872)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .