Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Awarded value is exclusive of all the applicable cess, tax and contingency as the same will be added in the final bill after successful completion of assigned work. | |
| 2 | L2₹7.8 L+₹16,207.69 (2.13%)Rejected-AOC | L2 | Rejected-AOC Put as L2 in panel. | |
| 3 | L3₹7.8 L+₹21,754.09 (2.86%)Rejected-AOC VILL GIRIRCHAK P O NARGHAT L S DIST PURBA MEDINIPUR PIN 721633 | GIRIRCHAK | PURBA MEDINIPUR | WEST BENGAL | 721633 | L3 | Rejected-AOC Put as L3 in panel. |
Tender Value
₹9.6 L
EMD Value
₹19,290
Closing Date
4 Jan 2021, 5:00 pmClosed
Headmaster, Lakshya High School (H.S.)
Lakshya High School (H.S.) Lakshya, Purba Medinipur PIN - 721654 (W.B.)
Construction of CMDMP Dining Room of Lakshya High School H.S. under Mouza Lakshya, JL No. 161 Plot No. 700 at Vill. and P.O. Lakshya, Purba Medinipur from CSR fund of IOCL, Haldia.
2020_DSE_311395_1
WBHM/LHS/1/2020-21
Open Tender
CIVIL AND ELECTRICAL WORKS
Item Rate
90 days
Lakshya, Purba Medinipur
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
₹19,290
27 Jan 2021
29 Dec 2020
7 Jan 2021
29 Dec 2020
4 Jan 2021
29 Dec 2020
Amount
Civil Construction of Dining Room at Ground Floor
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. (Ref. Civil Work Estimate Sl. No. 1.1)
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. (Ref. Civil Work Estimate Sl. No. 1.2)
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. (Ref. Civil Work Estimate Sl. No. 2)
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Ref.Civil Work Estimate Sl. No. 3)
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (Ref. Civil Work Estimate Sl. No. 4)
ordinary cement concrete (mix 1:1.5:3)with graded stone chips(20 mm nominal size) excluding shuttering and reinforcement if any, Pakur variety. (Ref.Civil Work Estimate Sl. No. 5)
Reainforcement for reinfored concrete work in all sorts of structure including distribution bars, sttirups, binder, etc lintel starightening and removel of loose rust, cutting to rquistic length, hooking and bending to correct shape, placing in proper positon(tor steel/Mild steel). (Ref. Civil Work Estimate Sl. No. 6)
Hire & labour charge for shuttering with centering and necessary staging upto 4m using apporved stout props and thick hard wood planks of apporved thickness with required bracing for concrete slab, beams and columns lintel etc. (Ref. Civil Work Estimate Sl. No. 7.1)
Hire & labour charge for shuttering with centering and necessary staging upto 4m using apporved stout props and thick hard wood planks of apporved thickness with required bracing for concrete slab, beams and columns lintel etc. (Ref. Civil Work Estimate Sl. No. 7.2)
Brick work with 1st class bricks in cement mortar (1:6) In superstructure, ground floor. (Ref. Civil Work Estimate Sl. No. 8)
125 mm th B/W with 1st class bricks in cement morter (1:3) in superstucture. (Ref. Civil Work Estimate Sl. No. 9)
A.S.F in floor, dado, staircase etc with cement concrete(1:2:4) with stone chips laid in panels as directed with topping made with ordinary or white cement and marbel dusting in proprotion (1:2)including smooth finishing and rounding off corners including raking joint 25 mm thick. (Ref. Civil Work Estimate Sl. No. 10)
woodwork for frame of door and windows fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, iron butthinges and M.s clamp Sal : Local. (Ref. Civil Work Estimate Sl. No. 11)
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (iii) 35mm thick shutters with 19mm thick panel of size 30to 45 Cm. (Sishu, Gamar,). (Ref. Civil Work Estimate Sl. No. 12)
Plaster (to wall, floor, celling0 with sand and cement morter including rounding off or chamfering corner as directed and raking joints including thoarting, nosing and drip coarse, scaffolding/stagging where necessary. (Ref.Civil Work Estimate Sl. No. 13.1)
Plaster (to wall, floor, celling0 with sand and cement morter including rounding off or chamfering corner as directed and raking joints including thoarting, nosing and drip coarse, scaffolding/stagging where necessary. (Ref.Civil Work Estimate Sl. No. 13.2)
Plaster (to wall, floor, celling0 with sand and cement morter including rounding off or chamfering corner as directed and raking joints including thoarting, nosing and drip coarse, scaffolding/stagging where necessary. (Ref. Civil Work Estimate Sl. No. 13.3)
M.S round or square bar grating of windows etc fitted and fixed in holes of windows frame and with intermediate flat but stiffner. (Ref. Civil Work Estimate Sl. No. 14)
M.S clamp for fixing door & windows frames made of 40 mmx6 mm flat upto 25 cm long end bifurcated in cement concrete. (Ref. Civil Work Estimate Sl. No. 15)
Iron but higes supplied & fixed with steel screw and also with washer as is nessary (100mm. X 50mm. X 1.25mm.). (Ref. Civil Work Estimate Sl. No. 16)
supplying, fitting,and fixing anodised iron hosp bolt complete (250mm long.). (Ref. Civil Work Estimate Sl. No. 17)
White washing including cleaning and smoothening surface thoroughly.(Two coats). (Ref. Civil Work Estimate Sl. No. 18)
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly two coats. (Ref. Civil Work Estimate Sl. No. 19)
Electrical work at Dining Room
Supply & Fixing (2+6) way S.P MCB BOD consisting of 1 no 40 A.D.P Isolator & 06 Nos. 6A-25 A A S.P MCB as per GS. (For Quarter) Make:Standard . (Ref. Electrical Work Estimate Sl. No. 1)
Cutting Channel of size (40 MM X 40 MM) on masonry wall by electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick polythene pipe without earth continuity wire by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG mending good damages to original finish by using own tools and tackles. PWD/GS/Page :E3/Item -6a. (Ref. Electrical Work Estimate Sl. No. 2)
Supply & Fixing 20 mm dia PVC Rigid Conduit 'FR'(Precision Make) on wall, ceiling with saddles and other accessories as required and mending good damages to building works. PWD/GS/Page:E3/item-7a. (Ref. Electrical Work Estimate Sl. No. 3)
Supply & laying of cable 2 core 6 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Ref. Electrical Work Estimate Sl. No. 4)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following size in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. Make: Finolex / KEI / Polycab / Havells / Gioster/ RR/Plaza PWD/GS/Page:E9/Item-C1. 2X36/0.3 (2.5 sqmm) + 1X22/0.3 (1.5 sqmm) as ECC (15A power plug / Computer board) (Ref. Electrical Work Estimate Sl. No. 5)
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following size in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. Make: Finolex / KEI / Polycab / Havells / Gioster/ RR/Plaza PWD/GS/Page:E9/Item-C1. 3X22/0.3 (1.5 sqmm) [for separate plug] (Ref. Electrical Work Estimate Sl. No. 5)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 2.5 sqmm (Ref. Electrical Work Estimate Sl. No. 6)
Distn. Wiring in 3x1.5sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (make-KEI / Havells / Finolex / RR cables) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with piano key type switch (Anchor make) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 3 no. "Ph & N" & 'E' copper bar incl. bakelite / Perspex top cover 3mm thick and incl. 175X100X65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish (all portion concealed) (Avg. run 6 Mtr.). (Ref. Electrical Work Estimate Sl. No. 7)
Supply & Fixing 240 V, 2 nos. 6A, Piano key type switch, (Brand approved by EIC) on Sheet metal switch board embedded in wall incl. S & F suitable size MS (16 SWG) switch board and bakelite / perspex top cover of 3 mm thick by Brass screw after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. 240mmX200mmX65mm (Ref. Electrical Work Estimate Sl. No. 8)
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch, (Brand approved by EIC) on Sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16 SWG) switch board and bakelite / perspex top cover of 3 mm thick by Brass screw after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required. PWD/GS/Page:E6/Item-22. (Ref. Electrical Work Estimate Sl. No. 9)
Supplying & Fixing MS fan clam of two piece type for RC Ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting - (As per Drawing no. 475 of PWD Specification, Book- May 1991) PWD/GS/Page:D14/Item-29. (Ref. Electrical Work Estimate Sl. No. 10)
Supply & Fixing Socket type fan regulator (Step type ) (Brand approved by EIC ) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. Connections etc. PWD/GS/Page:E6/Item-18b. (Ref. Electrical Work Estimate Sl. No. 11)
S&F 1200 mm sweep A.C. ceiling fan complete with blades, canopy, fork, rubber, bush etc. including S&F connecting wire for down rod up to 30cm includeing painting the rod with approved paint and making necessary connection as required. (Ref. Electrical Work Estimate Sl. No. 12)
S & Fixing Single/Twin 4' LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with "L" type MS clamp whose one side fixed on ceiling with sutable size 4 nos fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit,"L" type (125mm x 125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5 Sqmm.)flexible copper wire of 1.10 mt. length. incl. S&F 1200mm 18W master LED tube. Single Fitting Make : Magik (Ref. Electrical Work Estimate Sl. No. 13)
S& F 9W LED light make Philips / Crompton) on existing Holder Point. (Ref. Electrical Work Estimate Sl. No. 14)
GOBINDA BHOWMIK
T ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .