Loading…
Loading…
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
29 Jul 2026, 6:00 pm
GE South Delhi Cantt-10
GE South Delhi Cantt-10
MAINT AND REPAIRS/REPLACEMENT OF UNSERVICEABLE WIRING, MCBs, MCCBs, DBs, LIGHTS, SUMMER AND WINTER APPLIANCES INCLUDING ATENDING DAY TO DAY COMPLAINTS AT BANA SINGH ENCLAVE, PHILLAURAH ENCLAVE AND KHYBER LINE UNDER AGE E/M OF GE (SOUTH) DELHI CANTT
2026_MES_777118_1
GE/TOKEN-21/2026-27
Open Tender
Civil Works
180 days
GE South Delhi Cantt
As per Tender Documents
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹40,000
Yes
8 Jul 2026
8 Jul 2026
31 Jul 2026
8 Jul 2026
29 Jul 2026
22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | (iv) In addition to the above, the contractor shall arrange and maintain all necessary T&P required for execution of the work, such as multimeter , necessary electrical tools bag, tape roll , washers and screws of all sizes, , drilling machine with bits, and the like, including necessary safety measures, complete all as specified and directed by the Engineer-in-Charge.
(v) The cost of all the above arrangements, obligations, T&P, consumables, labour, safety measures, and incidental requirements shall be deemed to be included in the quoted rates of the respective items and no extra payment whatsoever shall be admissible on this account. | - | - | - | - |
| 2 | Supply and fix in repair of LED surface mounted Batten light 20 W 4 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F. ≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). ManufacturesWord Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEMmust have its own in house NABL lab setup for all testing facilities forLED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab forall testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housingsuch that LED junction temperature shall not rise above 90°C). complete all as specified and as directed. | 700 | Each | - | - |
| 3 | Supply and fix in repair of LED surface mounted Batten light 10 W 2 feet of Powder coated die cast /Extruded aluminium Body (Thickness >1.20 mm) and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc.as required. System lumen efficacy ≥120 and <135 lm/Watt outputt . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shapesize and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 100 | Each | - | - |
| 4 | S&F in repair decorative wall-mounted light fitting, body made of die-cast aluminum with powder-coated finish and frosted/clear glass/acrylic diffuser, suitable for holding LED lamp up to 15 Watt (B22 base), IP20 or higher protection, complete with all accessories for mounting on wall surface including screws, plugs, etc. Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose/DB, complete all as specified and directed. | 150 | Each | - | - |
| 5 | S&F in repair 12 watt LED Recessed/ surface Down lighter (Round/ square/Rectangular) SMD type Powder coated die cast /Extruded aluminum Body including trim with Aluminum Reflector with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C), complete all as specified and as directed. | 150 | Each | - | - |
| 6 | S&F in repair LED bulkhead light fitting, 10 Watt, white colour, housing made of high-grade flame-retardant engineering plastic with clear prismatic diffuser, suitable for wall or ceiling surface mounting. The fitting will be provided with replaceable LED lamp (cool white) and include all required mounting accessories.Connected with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required from ceiling rose, complete all as specified and directed. | 100 | Each | - | - |
| 7 | Supply and fixing in repair of LED bulb 12 Watt B-22 Cap, AC 230V, 50 Hz suitable for Batten Holder/Bulk head/SK light fittings in replacement of old unsv lights any type complete all as specified and as directed. | 300 | Each | - | - |
| 8 | Supply and fixing in repair of switch piano flush type 5/6 Amps SP one way complete all as specified and as directed. | 450 | Each | - | - |
| 9 | Supply and fixing in repair of switch piano flush type 5/6 Amps SP two way complete all as specified and as directed. | 10 | Each | - | - |
| 10 | Supply and fixing in repair of bell push, flush type 5/6 Amps complete all as specified and as directed. | 55 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TenderpagesT21.pdf
Tender Documents • 0.91 MB
BOQ_870303.xls
BOQ • 0.37 MB
SchofCreditT21.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid