Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹4.8 Cr
Closing Date
1 Jul 2026, 12:00 pm3d left
Similar tender results from the same govt authority in the past 3 years.
General Manager-ET
TCIL Bhawan, New Delhi
EOI Document for Selection of Consortium Partner for Design Supply Installation Testing Commissioning and Operation Maintenance of ATMS projects in Zone1 Delhi Region on EPC mode
2026_TCIL_281809_1
TCIL/ITTII/158/2026/ATMS
Open Tender
Electronic Components And Devices
2190 days
Delhi Region
As per EOI
3 documents required · 3 mandatory
₹11,800
Yes
Telecommunications Consultants India Limited
₹4.8 Cr
Yes
23 Jun 2026
23 Jun 2026
1 Jul 2026
23 Jun 2026
1 Jul 2026
23 Jun 2026
Video Surveillance System/Traffic Monitoring Camera System Equipment (TMCS)
PTZ Camera
Galvanized Iron (GI) Pole with cabinet for UPS & network equipment
LPU with all network equipment
Video Analytics for TMCS Module
Civil & Mechanical Works (Minimum M25 Grade and Fe500 grade steel reinforcement For Foundation, Chamber/Manhole, roadside equipment, PCC, digging, backfilling with sand, etc.)
Installation, Testing & Commissioning of TMCS Systems, including network cabling, power cabling from local source, MCB, Mounting arrangement & accessories for TMCS system, etc.
Power supplies for field equipment for 24*7 operation including renewable source, connections and UPS etc.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the TMCS system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
Video Incident Detection and Enforcement System (VIDES)
Overview Camera (including nightvision, covering all lanes including shoulders)
Side view camera (s) for ATCC
ANPR Camera with IR Flasher
LPU with all network equipment
Galvanised Iron (GI) Gantry with cabinet for UPS & network equipment
4 lanes
6 lanes
more than 6 lanes
Video Analytics for VIDES Module
Blinkers (Warning flashing light integrated with VIDES)
Civil & Mechanical Works (Minimum M25 Grade and Fe500 grade steel reinforcement For Foundation, Chamber/Manhole, roadside equipment, PCC, digging, backfilling with sand ,etc.)
Installation, Testing & Commissioning of VIDES Systems
Power supplies for field equipment for 24*7 operation including renewable source, connections and UPS etc.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the VIDES system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
Vehicle Actuated Speed Display (VASD)
Radar
Display
Galvanised Iron (GI) Gantry with cabinet for UPS & network equipment
4 lanes
6 lanes
more than 6 lanes
LPU with Networking equipment
Civil & Mechanical Works (Minimum M25 Grade and Fe500 grade steel reinforcement For Foundation, Chamber/Manhole, roadside equipment, PCC, digging, backfilling with sand ,etc.)
Installation, Testing & Commissioning of VASD Systems, Including network cabling, power cabling from local source, MCB, Mounting arrangement & accessories for VASD system, etc.
Power supplies for field equipment for 24*7 operation including renewable source, connections and UPS etc.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the VASD system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
Variable Message Sign (VMS)
VMS Fixed (M-Type)
Trolley Mounted Portable VMS
Galvanised Iron (GI) Gantry with cabinet for UPS & network equipment
4 lanes
6 lanes
more than 6 lanes
Networking equipment with interface card and accessories
Civil & Mechanical Works, Minimum M25 Grade and Fe500 grade steel reinforcement For Foundation, Chamber/Manhole, roadside equipment, PCC, digging, backfilling with sand ,etc.
Installation, Testing & Commissioning of VMS Systems Including network cabling, power cabling from local source, MCB, Mounting arrangement & accessories for VMS system, etc.
Power supplies for field equipment for 24*7 operation including renewable source, connections and UPS etc.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the VMS system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
OFC Backbone
OFC connectivity with 40 mm OD HDPE, with all necessary hardware, including 10% additional for the loops and spare.
Civil & Mechanical Works (including trenching, laying, backfilling, wherever applicable Manhole, Handhole etc. all complete)
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the OFC, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
TOTAL CAPEX PRICE (A)
O&M for 60 Months including Spares to cater the SLA requirement, Manpower, Electricity, vehicle, overhead etc
Comprehensive AMC of complete ATMS system, upgrade, Including Spare parts, repairing, warranties, replacing the components through the O&M period. SLA driven …......................
Recurring charges of Internet Connection
Recurring Electricity charges
Note 1: The cost of any other item not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s).
TOTAL O&M PRICE (B)
TOTAL (A + B)
Video Incident Detection and Enforcement System (VIDES)
Overview Camera (including nightvision, covering all lanes including shoulders)
Side view camera (s) for ATCC
ANPR Camera with IR Flasher
LPU with all network equipment
Galvanised Iron (GI) Gantry with cabinet for UPS & network equipment
4 lanes
6 lanes
14 lanes
Video Analytics for VIDES Module
Blinkers (Warning flashing light integrated with VIDES)
Civil & Mechanical Works (Minimum M25 Grade and Fe500 grade steel reinforcement For Foundation, Chamber/Manhole, roadside equipment, PCC, digging, backfilling with sand ,etc.)
Installation, Testing & Commissioning of VIDES Systems
Power supplies for field equipment for 24*7 operation including renewable source, connections and UPS etc.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the VIDES system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
OFC Backbone
OFC connectivity with 40 mm OD HDPE, with all necessary hardware, including 10% additional for the loops and spare.
Civil & Mechanical Works (including trenching, laying, backfilling, wherever applicable Manhole, Handhole etc. all complete)
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the OFC, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
TOTAL CAPEX PRICE (A)
O&M for 60 Months including Spares to cater the SLA requirement, Manpower, Electricity, overhead etc
Comprehensive AMC of VIDES system Including Spare parts, repairing, warranties, replacing the components through the O&M period.
Recurring charges of Internet Connection
Recurring Electricity charges
Note 1: The cost of any other item not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s).
TOTAL O&M PRICE (B)
TOTAL (A + B)
Local ATMS Control Centre (Local ATMS CC)
Video wall for TMCS
Video Wall for VIDES
Desktops including peripherals
Network Colour Printer
Servers/Cloud and Data Storage including peripherals (NVR / CAMERA SERVER with NAS/RAID Backup device) all complete as per the Standards & Specifications
Interior, Civil, Mechanical, Electrical and other allied works including CCTV cameras etc. as per Schedule B
Installation, Testing & Commissioning of ATMS Local Control Centers
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the Local ATMS Control Centre system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
Regional ATMS Command & Control Center (Regional ATMS CCC)
ATMS Central Processing Server, In Hot Standby Configuration (Primary + Secondary) with 21" Monitor, Operating System, Antivirus and Any Other required application/tools.
Database licensed Edition Latest version of Database as per requirement.
Video Wall 3x3 Dimension, 70-inch cubes along with outer Video Wall frame, Video Wall Controller, required Subcomponents & Accessories
Server for hosting third-party COTS Applications (NMS And Integrated Helpdesk) with Operating System, Antivirus and any Other required application
Network Management System (NMS) Solution Third-party Commercial Off-The-Shelf (COTS) Solution to monitor all network components of ATMS Projects
Helpdesk & Inventory Management Solution Third-party Commercial Off-The-Shelf (COTS) Solution
VoIP based IP Telephone Set for the ATMS Control Centre Building Premise
Network-Attached Storage (NAS) Minimum 32 TB redundant RAID storage and scalable as per project requirments
KVM Switch Rack mounted with Minimum 08 Ports
Operator Workstation (Multi-Screen) with 21-inch Dual Monitor, Wireless Keyboard, Mouse along with Windows Operating System (Latest available edition), Antivirus and any Other required application
Rack 42 U for Server Room
Rack 12 U For Network Components in Server Room
Fibre Optical Network Switch With 24 SFP port with loaded SFP modules to fulfil all requirements and two RJ 45 Gbe ports
Layer-3 manageable Network Switch with 24 Gbe ports with 4 SFP ports along with loaded module
Manageable Network Switch with 8 ports
LaserJet Colour A3 Printer ( MFP )
10 KVA UPS in hot standby mode with battery (Lithium-ion) backup of 4 Hours for control room
Firewall along with all required software license (IDS & IPS)
50 KVA Servo Stabilizer For Control Room
Biometric attendance system with door Access Control System including the Door Lock accessories, all software/hardware solution for minimum 05 doors.
NVR 48 channel for the Regional CCC building CCTV cameras along with 60 days recording storage at 25 FPS
CCTV Dome Camera for Control Centre building Surveillance
Cabling (Network and power cabling in the building), Power distribution boards ( MCB, switch, sockets, etc.), power cable connection from Servo Stabiliser and UPS to all components of ATMS Control Centre, Server Room & other rooms/cabins of the building.
Note 1: The cost of any other ancillary, incidental, or associated item(s) required for the complete supply, installation, testing, and commissioning of the Regional ATMS Command and Control Centre system, if not explicitly mentioned above, shall be deemed to be included in the respective applicable line item(s). Note 2: The entire sub-system shall be integrated to local, national and regional NMS and its health check valdiated. The integration with distant NMS can be exhibited on appropriate application/terminals.
Power supplies for ATMS Command & Control Centres (Local and Regional) for 24*7 operation including renewable source, connections and UPS etc.
TOTAL CAPEX PRICE (A)
O&M for 60 Months including Spares to cater the SLA requirement, Manpower, Electricity, overhead etc
Manpower cost
Comprehensive AMC of complete ATMS system, Including Spare parts, repairing, warranties, replacing the components through the O&M period.
Recurring charges of Internet Connection
Recurring Electricity charges
Any other item TO BE SPECIFIED here for completing the ATMS Control Centre mentioned in Schedule B as per standard and specification mentioned in Schedule C (Leave blank if nill)
TOTAL O&M PRICE (B)
TOTAL (A + B)
(Qualification Criteria and Experience as per RFP)
ATMS Incident Manager
OFC/Network Technician
Incident Operations Staff
ICCC Manager
IoT/ Network Engineer
AI Analytics & Applications Engineer
ICCC Operators
Capex
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.08 MB
EOIATMS23062026.pdf
Tender Documents • 1.06 MB
Financial Bid.xls
Tender Documents • 0.11 MB
Client RFP.pdf
Tender Documents • 8.73 MB
Download all tender documents and submit your bid