Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹30.1 L+₹3.9 L (14.7%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹30.7 L+₹4.4 L (16.9%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹31.0 L+₹4.7 L (18.0%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹31.7 L+₹5.5 L (20.9%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
29 Sept 2020, 6:00 pmClosed
R S SHUKLA EE
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR TO HARDSTANDING SCOOTER CYCLE SHED GARAGES AND OTHER TRAINING AREAS OF AAD CENTRE AND MISC EM WORKS AT AAD CENTRE AND AAD RECORDS AT ZONE B AREA AT GMS
2020_MES_376110_1
8000/42/20-21/0943/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR MILITARY STATION
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹50,000
Yes
23 Oct 2020
9 Sept 2020
1 Oct 2020
9 Sept 2020
29 Sept 2020
23 Sept 2020
Amount
Dismantling of AC corrugated / semi corrugated sheet as in roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Excavation in any type of soil for post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connected plates of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S&F fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugation side lap fixed with L-type or J- type or cranked hook bolt in roof, wall etc complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in bond stone complete all as specified and directed.
M&L for walling of random rubble uncoursed stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
All as per ser item No 6 above but except stone
Hammer dressing to RR masonry wall (granite basalt/trap stone) uncoursed with maximum depresion of 40 mm from straight edge held against the surface complete (for area to be pointed)
M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L 100mm thick Cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggreates as in flooring finished even and fair complete all as specified and directed.
M&L for cement concrete tiles of size 250 mm x 250 mm x 20-22 mm thick machine pressed set jointed and pointed in neat cement slurry in floor and cut and polished with grey cement and pigment, including 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for sand cushioning including spreading in layers and rolled consolidated to thickness of 50mm (minimum) for receiving precast PCC interlocking blocks complete all as specified and directed
S&F machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 Type B-2 using 40mm graded stone aggregate in pavement/hard-standing laid in alternative panels, surface finished even and smooth without using extra cement, including necessary form work, complete all as specified and directed.
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick on other than fair face of brick works in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M & L for two coats of cement based paint on new plastered surface of walls including preparation of surface complete all as specified and directed.
Demolition of RCC as in bands, Linter and similar suspended work.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
M&L for RCC (nominal mix) 1:2:4 type B-O using 12.5 mm graded stone aggregate as in slab supported on wall,beam and column in floors, roofs, landings, balconies, canopies and in shelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
Mild Steel TMT bar 5mm dia and over upto and including 10mm dia as in stirrups, spacers & binders cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
M&L for taking down carefully old UNSV aluminium point wiring with wooden batten and all accessories of(light, fan, socket or power) such as switches socket ceiling rose, fan regulators, light fitting, main switches DB’s etc and making good disturb surface complete all as specified and directed.
M&L for point wiring with cable PVC insulated but unsheathed, 1.5 Sqmm, stranded copper conductor in and including PVC casing caping duly surface continuous earthing with cable PVC insulated 1.5 Sq mm copper conductor, MS box including laminated top sheet cover,washer & screw all as specified and directed for One light point controlled by one, one way switch.
All as per itme No 37 above but for One fan point controlled by one, one way switch.
All as per itme No 37 above but for One exhaust fan point controlled by one, one way switch.
All as per itme No 37 above but for One 5 Amp socket point controlled by one switch on independent board
All as per itme No 37 above but for One 5 Amp socket point controlled by one switch on same board
One light point controlled by two 2 - w a y s w i t c h e s , with cables 1.5 sq. mm
All as per item No.37 above but with cable PVC insulated 4.0 Sq mm (FR) in and including PVC casing caping incl continuous earthing with cable PVC insulated 2.5 Sq mm copper conductor for power socket 15Amps (Make : Anchor/ Standard/ Finolex/Havells/HPL)
S&F switch socket combination 2-in-1, 5 pin 5 Amp (Make : Anchor/ Standard/ C&S/Havells/HPL).
S&F switch socket outlet 5 pin 5 Amp (Make : Anchor/ Standard/ C&S/Havells/HPL).
S&F switch socket combination 2-in-1, 5 pin 5 and 15 Amp (Make : Anchor/ Standard/ C&S/Havells/HPL).
S&F switch piano (Flush type) 5 amps, 240 Volts, single pole one way.
S&F switch piano (Flush type) 5 amps, 240 Volts, single pole two way.
S&F ceiling rose, bakelite three terminal complete all as specified and as directed
S&F bell ding dong electric single phase 240 Volt. Make : .(Cable make Anchor/Havells / Finolex/RR Kabel)
S&F ceiling fan regulator electronic step type socket mounting type. (Make : Anchor/ Standard/ C&S/Havells/HPL)
S&F LED light fitting 18/ 20 Watt T5 batten type,PVC extruded batten with decorative end caps complete with polycarbonate /glass tube 4Ft White , internally pre-wired and including connecting up with suitable twisted flexible copper conductor cable with suitable size complete all as specified.
S&F of light fittings (2Ft) with wall mounted LED pattern with polycarbonate housing & integrated electronic driver of 9W cap T5(max lenght upto 600mm) complete all as specified and directed. Make :- (Make C&S /WIPRO/ CG / Phillips / Havells) (Note : Contractor shall submit warratny for 03 yrs)
S & F lamp holder PVC insulated body suitable for batten fitting straight/angle modular type with LED reterofit bulb 9 watts cap complete all as specified and directed Make-Anchor/leader/SSK and bulbs C&S, Havells, Crompton
S&F in replacement of bldg security light fitting LED type of 20 watt New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 luminaire with high power LEDs as light source and electronic driver. mounting bracket suitable to house the light fittinhg , with its Galvanised Flat Iron clamps conntected nuts bolts etc complete all as specified & directed (Make C&S /WIPRO/ CG / Phillips / Havells) (Note : must for warrenty of 3 yrs to 5 yrs)
M&L for replacement of 2 Runs of cable PVC insulated but unsheathed 4.0 Sq mm, stranded copper conductor in and including PVC conduit with continuous earthing cable PVC insulated 4.0 Sq mm, stranded copper conductor all as specified and directed.(Cable make Anchor/ Havells /Finolex)
M&L of 2 Runs of cable PVC insulated but unsheathed 6.0 Sq mm, stranded copper conductor in and including PVC conduit with surface wiring continuous earthing cable PVC insulated 10 Sq mm, stranded copper conductor complete all as specified and directed.(Cable make Anchor/Havells/Finolex) Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
M&L of 2 Runs of cable PVC insulated but unsheathed 10 Sq mm, stranded copper conductor in and including PVC conduit with conceiled wiring continuous earthing cable PVC insulated 6.0 Sq mm, stranded copper conductor complete all as specified and directed.(Cable make Anchor/Havells/Finolex) Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S & F in replacement sheet metal enclosure vertical DBs with provision for FP MCCB frame upto 100A in 16,KA, 25KA, as incomer 4 way double door made complete all as specified and directed Make Standard/ Indo asian/ Havells/Anchor
S & F sheet metal enclosure double door MCB DB, SPN 8way complete all as specified and directed.
S & F MCCB 100 Amps 4 Pole 25 KA 415Volts (Make : Anchor/ Standard/ C&S/Havells/HPL)
S & F MCCB 63 Amps 4 Pole 16 KA 415Volts (Make : Anchor/ Standard/ C&S/Havells/HPL)
S & F TPN 40 Amps 415Volts (Make : Anchor/ Standard/ C&S/Havells/HPL)
S & F MCB SPN 16 TO 32 Amp 10 KA 240 Volts (Make : Anchor/ Standard/ C&S/Havells/HPL)
S & F MCB, SP 6 to 30 Amp 240 Volts rating (Make : Anchor/ Standard/ C&S/Havells/HPL)
S&F exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver complete all as specified and as directed.
S & F in minor repairs to FTL fittings by replacing bi-pin holders, connections , tube rods of any type and capacity etc complete all as specified and direted (Note : Tube rods shall be issued under Sch B stores from MES Stores)
S & F PVC conduit pipe 20mm dia complete alongwith necessary fixing arrangement complete all as specified & directed
S & F PVC casing capping 25mm complete alongwith necessary fixing arrangement complete all as specified & directed
S&F in replacement of 3 pin 15 Amps plug top complete all as specified and directed. Make Anchor/SSK/Indo Asian
S& F in replacement of Electronic Ballast suitable for 36/40 watts FTL conventional light fittings complete all as specified and directed (Make Anchor, havells, Bajaj, CG, C&S)
S& F in replacement of Electronic Ballast suitable for 28 watts FTL conventional light fittings complete all as specified and directed (Make Anchor, havells, Bajaj, CG, C&S)
S&F in replcment of single pole and neutral enclosure with a two pin and earth plug socket 240 V with one MCB SP ‘C’ series rating 20 to 30 Amp complete all as specified and directed. Make: L&T/standard/CG/ C&S / Havells
M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level)with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers protected with & including 15 mm dia light grade GI pipe necessary excavation and earth works, charcoal and common salt filling, watering arrangement with 20 mm GI pipe light grade including PCC pit with Pre cast RCC (1:2:4) cover, GI funnel with mesh test point, testing & commissioning complete all as specified and directed.
M/s Bapujee Builders and Traders
M/s TECH TEAM
M/S SIWALIK AND CO
M/S. KISHAN ENGINEERING
S J ENTERPRISES
R J ENTERPRISES
M/s MAA BHAIRABI ENTERPRISES
M/S JAGANNATH SASMAL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .