| 1 | L1₹14.2 LAccepted-AOC HARINAGAR BEHIND MAHESHWARY MARKET PO TATISILWAI DIST RANCHI PIN 835103 | RANCHI | JHARKHAND | 835103 | ₹14.2 L Quoted ₹14.5 L | L1 | Accepted-AOC Lowest and Reasonable |
| 2 | L2₹15.5 L+₹99,889 (6.89%)Rejected-Finance | ₹15.5 L+₹99,889 (6.89%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹15.9 L+₹1.4 L (9.44%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹15.9 L+₹1.4 L (9.44%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹17.8 L+₹3.3 L (23.1%)Rejected-Finance | ₹17.8 L+₹3.3 L (23.1%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹19.1 L+₹4.6 L (31.7%)Rejected-Finance KUSUM VATIKA SHIV SHAKTI NAGAR KOKAR RANCHI 834001 | RANCHI | JHARKHAND | 834001 | ₹19.1 L+₹4.6 L (31.7%) | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
1 Feb 2021, 6:00 pmClosed
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 835217
SPL REPAIR TO WOODEN UNSERVICEABLE WINDOWS AND VENTILATOR IN BLDG NO. P-40 P-41 JCOS OR MD ACCN OF 286 FD REGT SPL REPAIR TO ROOF TOP SURFACES OF P-17 ADM BLOCK OF 286 FD REGT AND SPL REPAIR TO WASTE WATER SEWAGE DISPOSAL SYSTEM IN BLDG NO. P
2020_MES_407360_1
8000/1644/E8
Open Tender
Civil Works
Item Rate
120 days
DIPATOLI
CLASS E CATEGORY a(i)
7 documents required · 7 mandatory
₹500
Yes
GE DIPATOLI
₹29,000
Yes
20 Apr 2021
4 Jan 2021
3 Feb 2021
4 Jan 2021
1 Feb 2021
18 Jan 2021
Amount
Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.50 Sqm each complete including removing from site complete all as specified and as directed.
Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 Sqm and n exc 4.0 sqm each complete including removing from site complete all as specified and as directed.
S&F powder coated three track aluminium window shutter sliding type with frame of powder coated aluminium channel section suitable for sliding aluminium shutters weighing 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium shop beading screws, with and including two shutters 5mm thick coloured glass and one shutter with stainless steel wire gauge including necessary locking arrangement and handle etc., as specified etc., complete all as specified and directed
S&F powder coated aluminium ventilator louver type with frame, aluminium section weighing 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc., complete all as specified and as directed.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as specified and as directed.
M&L for preparing the newly surface of any description not otherwise described over 10 cm width or girth on steel surface and applying two coats of synthetic enamel paint over one coat of zinc chromate primer complete all as specified and as directed.
Taking down cement plaster including racking out joints, hacking for key, scrubing down with water etc. complete all as specified and as directed.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work/concrete surface and finished the surface even and smooth without using extra cement complete all as specified and as directed.
M&L preparation of newly / old plastered surfaces of wall and applying a coat of wall care putty not less than 1mm thick to make the surfaces truly smooth complete all as specified and as directed.
M &L for applying two coats of distemper oil emulsion over a coat of primer white or tinted on already prepared wall surfaces (or necessary preparation if required ) complete all as specified and as directed.
M &L for preparation of newly plastered surface of wall and applying two coats of cement base paint over a coat of primar complete all as specified and directed.
Demolition of side wall and top of old RCC water tanks 1000/500 ltrs capacity excluding tank beam and tanks bottom slab after removing existing inlet and outlet connection with all fitting and reparing remaining structure with plastering and making the surface flat and level with CM (1:4) complete all as specified and as directed.
Dismantaling of existing water tanks and removing to store and S&F 1000 ltr capacity triple layered rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions complete all as specified in SSR Part-I, with and including 20 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe, GI overflow pipe, GI washout pipe, anti mosquito cap and fixed complete all as specified and as directed.
Taking up or down steel tubing and connection of 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connection of 20 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connection of 25 mm bore complete all as specified and as directed.
S&F 15 mm bore steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket, elbow, nipple, union etc complete all as specified and as directed.
S&F 20 mm bore steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket, elbow, nipple, union etc complete all as specified and as directed.
S&F 25 mm bore steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket, elbow, nipple, union etc complete all as specified and as directed.
Refixing only 15 mm bore steel tubing and connection in new or old position to walls, ceiling, floors etc with and including new GI fittings complete all as specified and as directed.
Refixing only 20 mm bore steel tubing and connection in new or old position to walls, ceiling, floors etc with and including new GI fittings complete all as specified and as directed.
Refixing only 25 mm bore steel tubing and connection in new or old position to walls, ceiling, floors etc with and including new GI fittings complete all as specified and as directed. Note for Srl item No. 20 to 22:- Old GI pipe shall be retrieved from srl item No. 17 to 19.
S&F in repair Gun-metal, globe or gate valves 20mm bore, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
M&L for roof treatment in repair by complete removal of existing old treatment and treated with following specifications :- (a) Brushing neat cement slurry @ 3Kg per Sqm on roof slab. (b) 15 mm thick cement plaster fair finished using cement mortar (1:4) with WPC on roof slab. (c) Applying oil based bitumen primer @ 0.30 ltr/Sqm on plastered surface. (d) Applying modified APP polymeric membrane 3mm thick and minimum weight 3.00 Kg / Sqm for water proofing of roof , sealing as directed at site with 100 mm over laps as per manufacture's instruction. (e) Applying two coat of aluminium paint @200 gm/Sqm over bituminous surface of membrane. Note:- Supply only WPC shall be measured and paid separately under relevant item.
Supply only integral water proofing compound. complete all as specified and as directed.
Excavation over area not exc. 1.5mtr deep and getting out in soft/loose soil completed as all specified and directed.
Excavation over area exc. 1.5mtr but n exc 3.0mtr deep and getting out in soft/loose soil complete as all specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil etc. including trimming bottom and sides of trenches, leveling/ grading and ramming bottom of excavation complete all as specified and directed.
Excavation in trenches n exceeding 1.5 m wide and exceeding 1.5 m in depth but not exceeding 3.mtr depth and getting out in soft/loose soil etc. including trimming bottom and sides of trenches, leveling/ grading and ramming bottom of excavation complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing surplus excavated soil to a distance exc 250m but n exc 500m and depositing where directed complete all as specified and directed.
Demolition and breaking up 150mm dia drain pipes (salt glazed, stoneware, AC or reinforced concrete) drain pipe, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
M&L for concrete bed for 150 mm bore pipe with PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M & L for salt glazed stoneware drain pipes of 150mm dia bore grade 'A', laid in trenches and jointed complete all as specified and as directed.
Taking down eaves, gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall) as fixed along the centre line over fittings and accessories complete all as specified and directed.
M&L for 110mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints fixed on walls excluding clamps fixed to wall properly including fixing of pipe with PCC (1:2:4) complete all as specified & directed.
M&L for stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
M&L for 75mm bore, PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, laid in trenches or in floors complete all as specified & as directed.
M&L PVC (SWR) bend any radius 110mm diacomplete all as specified and directed.
M&L PVC (SWR) bend any radius 75mm dia complete all as specified and directed.
M&L PVC(SWR) Tee any radius 110mm dia complete all as specified and directed.
M&L PVC(SWR) Vent cowl 110mm dia complete all as specified and directed.
S&F 100mm dia Branch piece, single (equal or unequal), ordinary or inverted, spigot or socket type or with parallel branches complete all as specified and as directed.
M&L for brick work with sub class "B" bricks straight or curved on plan exceeding 6 mtr mean radius and built in CM (1:4) complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs n. exc. 200mm thick in rough finished surfaces etc complete all as specified and directed.
M&L for RCC (1:1.5:3) type A-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns etc complete all as specified and directed.
M&L for RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in precast manhole / septic tanks covers with and including necessary form work and setting in CM (1:4) complete all as specified and directed.
M&L for mild steel deformed bars 6-8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
M&L for providing PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in coping of manholes and similar work complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation bed of manhole, mass concrete etc complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1(using 20 mm graded stone aggregate) as in channels, benching of manhole, laid to shape and slope, surfaces finished even and smooth using extra cement including necessary form work etc complete all as specified and directed.
Cutting into exisiting manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1, smooth finished and reforming benching as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey comb walling built in CM (1:4) complete all as specified and directed.
M&L for filling of brick bats in soak well laid dry complete all as specified and directed.
M/S AMOD KUMAR PANDEY
M/s Kamleshwar Singh
M/S SAI UDYOG
Delhi Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .