| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.5 L+₹98,044 (2.76%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.9 L+₹1.4 L (4.03%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance L3 | |
| 4 | L4₹37.3 L+₹1.8 L (5.20%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹38.4 L+₹2.9 L (8.15%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
12 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-99/2023-2024 ADDN ALTN TO ROOM NO 41 TO 43 AND 62 TO 64 OF BLDG NO P-163 A AT CHANDIMANDIR
2024_MES_639217_2
GE/CHM-99/2023-2024
Open Tender
Civil Works
Item Rate
90 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹84,000
Yes
6 Nov 2024
24 Feb 2024
14 Mar 2024
24 Feb 2024
12 Mar 2024
5 Mar 2024
Amount
Powder coated aluminum sections as in frames/ shutter of doors/window/ventilators /partitions, (Sliding / openable) including joinging cleats, glazing clips, rubber neoprene beading, powder coated aluminim snap beading, screws etc. complete all as specified and directed Note : (i) Minimum thickness of power coating shall not be less than 50 micron. (ii) Weight of aluminum section only shall be measuerd and paid. (iii) Aluminum doors/windows /ventilators to be fixed to jambs with chromium plated screws . (iv) The rate shall be inclusive of neoprene beadings, snap beading, screws etc and in case of sliding shutters locking arrangement and rollers in sliding shutters. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section. (v) Glass /wooden panel/ACP sheet shall be measured and paid separately under respective items. (vi) Design as directed by Engineer in charge.
Supply only 5.5mm thick tinted sheet glass, fixed to aluminum frame work with and including standard anodized aluminum bead, rubber packing, aluminum screws etc, in panels exc 0.5 Square metre in each pane, complete all as specified & directed.
Supply only 3mm thick aluminium composite panel sheet (ACP) colour as approved by Engr In Charge all as specified and directed.
10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed.
200 mm size aluminium, barrel tower bolt of extruded section and fixed for PVC door complete all as specified and directed.
Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, all as specified and directed.
Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed.
Mortice lock, verticle type, mild steel, 4 levers, size 100mm, brass body, complete all as specified and directed
Door closer hydraulically regulated of aluminium extruded section, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg, fixed as in repair complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty , complete all as specified and directed.
D' type, 150mm aluminium powder coated handles for aluminium doors complete all as specified and directed.
Solid 14mm thick wood polymer composite louvers wall paneling (size 192mm x 2900mm x 14mm) fixed to walls with necessary clip, screw / adhesive complete all as specified and directed. NOTE : The wall paneling has to be in conformity with the existing wall paneling at site. Bidders ae requestd to visit the site before quoting their bid.
2mm thik PVC sheet fillet/ angle / beading of width 35mm for making frame for wall paneling inclusive of fixing on to wall , complete all as specified and directed at site.
Demolition of brick work, stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles all as specified & directed
Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
10mm thick rendering in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement including taking down existing plaster complete all as specified and directed
Preparation of old decorated wall surfaces and applying two coats of oil bound distemper complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer, over and including 2mm thick (average) wall care putty and sand papering, complete all as specified & directed by Engineer-in-charge.
Dismantling of boarding, any description, fixed in any position with nails or screws and providing & fixing hangers of 6 mm dia. G.I. (upto 1200mm length), adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat of 40 x 3 mm size, 60mm long and expansion hold fasteners of 12.5mm dia, 40mm long with and including anodised aluminium snap grid of size 605mm x 605mm, framed work for false ceiling with and including 4mm thick non asbestos fibre cement building boards fixed in aluminium framework with screws, complete all as specified and directed
Dismantling floor hearth or wall tilling including cement mortar bedding, complete as specified and directed.
Coloured vitrified ceramic tiles, light shade, 10mm thick (square ) , area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
All as per serial item No 21 hereinbefore but on vertical surface over 10mm rendering in cement mortar (1:4).
Taking down chowkhats or frame n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed.
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specified & directed.
Factory made 18mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg /cum of one side prelaminated / rigidlam with any colour and other side balancing laminate as in cup board/ kitchen cabinet shutter/ drawer, front shuters, fixed with screws, solvent / adhesive complete all as specified and directed.
18mm wide & 1mm thick PVC edge bending of WPC pasted on edges with suitable adhesive, compelte all as specified and directed.
Continuous (piano) hinges, mild steel bright finish, width of flap when open 40mm, fixed as in repair complete all as specified and directed.
PVC body magnetic shutter catcher for kitchen cup boards, fixed with standard steel screws, complete all as specified and directed.
100 mm aluminium handles fabricated type complete all as specified and directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
All as per serial item 31 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
All as per serial item 31 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 31 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
LED lamp 9 watts, B-22 type (invertor bulb) complete all as specified .
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 to 160Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed .
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp Complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp Complete all as specified and directed.
MCB, SPN , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
32Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB, SP, 240 volt, 40 Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Slim LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Slim LED lights fitting, 2 feet, 1x 10W, inverter rechargeable, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
LED pannel surface mounted o size 2'x2', 36 watts cool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Supply and fixing sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Supply and fixing sub main wiring with Four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of 2 single core size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 4 single core of 10 sqmm and two single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
32 to 40 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.
Exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, and frame and louvers complete all as specified and directed.
Wall mounted fan PVC body, 400mm sweep, 230 volt , AC, quick start torque motor with copper winding complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of 20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 25 x 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of 20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including copper strip 20 x 3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe of 20mm dia, GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note for serial item No 67, 68 & 69 :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
Earth continuity conductor coper strip 20x 3 mm with saddles and fixing screws etc in wall complete all as specified and directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying cables, poles, stay etc and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Removal of excavated material to distance not exceeding 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed.
Dry sand cushioning to underground cables with 8cm thick layer before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed.
Laying only burnt bricks in trenches, over underground cable for cable protections, width of brick along the length of the trenches complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core, laid in trenches , sleeving through pipes of fixed on poles & wall or laid under floors inlcuding jointing with suitable size of alumunium lugs as specified and directed.
100mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed
Supplying, installing and commissioning of split type air conditioner with cooling function EER 3.2 of capacity 2TR, 05 star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, 05 star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, PVC pipe medium duty 25 mm dia for draining out condensed water, all as required including necessary electric connections, complete all as specified and directed. Note :- (i) Quoted rates shall deem to includ the cost of drain pipe, copper tubing of requisite length and 4 sqmm multi standard copper cable , brackets, etc. (ii) Installation and commissioning to be done through OEM / its authorised service centre / agency.
Supply, install, testing and commissioning of diesel Engine driven generating set of min 62.5 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM conforming to relevant IS Codes, AC power supply with power factor 0.8 coupled directly to alternator mounted on a common MS base frame with sturdy design complete with AMF panel, integral acoustic enclosure-sound proof canopy (should have silent features as per latest CPCB norms), fuel tank with draw-out/drag-out facility for easy cleaning, SMPS power supply unit of relevant Amperage and Voltage for Battery Charging in case of non-operation for long periods, long life in all weather conditions & for outdoor application/installation, incl battery & standard accessories, and 5 Years Comprehensive Annual Maintenance Package by OEM/Manufacturer including consumables and unlimited visits by service engineer all as specified and as directed with following specification :- (A) ENGINE : Liquid Cooled, electric start, 4 Stroke, min 4 cylinders cold starting, TCI aspirated, compression ignition, totally enclosed diesel engine at 1500 RPM developing min 67 BHP capacity to match min 62.5 KVA alternator under NTP conditions as per ISO 8528 Part-I with provision of 10% over load for 1 hour in every 12 hours running confirming to IS: 10000/ISO 3046/ BS: 649/ BS: 554 amended up to date, the Engine shall consist of the following :- (i) Dynamically balanced fly wheel or as per manufacturer's standard. (ii) Coolant cooling system complete. (iii) Air cleaner as per manufacturer's standard. (iv) Fuel injectors and fuel pump as per manufacturer's standard. (v) Electronic/ mechanical governor as per manufacturer's standard to maintain engine speed at all conditions of load. (vi) Fuel service tank of minimum 185 Ltr capacity fabricated from MS sheet with draw-out/drag-out facility, inlet outlet connections air vent tap, level indiactor, MS fuel piping from tank to engine with valves, unions, reducers, flexible hose connections, mounting pedestals, fuel filters incl all as per manufacturer's design. (vii) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce noise level as per CPCB norms (viii) Battery charging alternator unit along-with SMPS PSU and voltage regulator, suitable for starting.
(ix) Gear driven oil pump for lubricating oil, priming of engine bearing, as well as fuel systems as per manufacturer's recommendation. (x) Natually aspirated/turbo charger as per manufacturer's standard. (xi) Lubricaton oil coolers and filters with replaceable elements as per manufacturer's standard (xii) Crank case heater with manufacturer's recommendation. (xiii) All moving parts of the engine shall be mechanically guarded in such a manner that a human finger cannot touch any moving part (xiv) Radiator as per manufacturer's standard. (xv) Engine control panel having digital display complete with :- (aa) Start/stop key switch (ab) Lubricating oil pressure indication (ac) Lubricating oil temperature indication (ad) Water temperature indication (ae) RPM indication (af) Engine hours indication (ag) Battery charging indication (ah) Low lub oil trip indication (aj) High water temp indication (ak) Over speed indication (xvi) Any other item not included/specified but is a standard design of the manufacturer. (B) ALTERNATOR (i) Alternator of capacity 62.5 KVA at 1500 RPM, 0.8 lagging power factor, 3Ph, 415 V, 50 Hz, H Class insulated winding, IP-23 protection, Close-direct-coupled, self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base frame, alternator shall be confirming to IS: 13364, IS: 4722, BS-5000, IEC: 34 and suitable for tropical condition.
(ii) Type : Self exited self regulated with automatic voltage regulator (electronic type) (iii) Rating : 62.5 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. (iv) Speed : 1500 RPM (v) System : 415 Volt +/- 5 % AC 3 phase 4 wire 50 Hz. (vi) Connection : 4 wire star connected. (vii) Enclosure : Screen protected drip proof. (viii) Ventilation : Self ventilated (ix) Anti friction bearings (x) AVR output voltage within +/- 1% (C) CONTROL PANEL The control panel is to be inside canopy and fabricated out of 1.6mm thick CRCA sheet cubicle type totally enclosed, powder coated, IP-53 protection, equipped with MCCB of suitable capacity, voltage metering & safety, frequency meter metering & safety, ampere metering & safety, fuel level gauge in % metering , Lub oil pressure metering, high water temp metering, engine RPM metering, Power metering, Power factor metering, set of suitable CTs, toggle switch, idicating LED lamps , incoming and outgoing terminals all as specified by manufacturer and directed by Engr-in-Charge. (D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Base frame of sturdy design and necessary reinforcement with built-in diesel tank as per manufacturer's standard. (i) Fuel tank of sheet metal complete with drain valve, air vent, inlet, outlet connections, and mechanical gauge. (ii) One No battery 12V charged with connecting leads of suitable capacity as per manufacturer's standard. (iii) Fuel tank should be of draw-out/drag-out facility for easy cleanout. (iv) SMPS PSU for battery charging in case of non-running of DG set for long periods. (v) 5 Years Comprehensive Annual Maintenance Package by OEM/Manufacturer including consumables and unlimited visits by service engineer. (vi) PCC work (1:2:4, M-20 grade) of suitable dimension for foundation of DG set as recommended by the Genset Manufacturer/OEM/OEA shall be deemed to be included in the quoted rate.
Supply and installed voltage stabilizer automatic digital display type, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 Volt with output voltage stabilized at 230 Volt +/- 2.5% of capacity 5 KVA complete all as specified and directed.
MS R G ENTERPRISES
R D Bansal
M/s Krishan Aggarwal
KUNDRA CONSTRUCTIONS
Vasudeva Trading Co.
S S CONSTRUCTION
M/S DEV RAJ
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .