| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC | L1 | Accepted-AOC AOC issued | |
| 2 | L2₹2.3 L+₹2,400 (1.03%)Rejected-Finance NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L2 | Rejected-Finance That the Bid is not L1 | |
| 3 | L3₹2.4 L+₹9,450 (4.07%)Rejected-Finance 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance That the Bid is not L1 | |
| 4 | L4₹3.7 L+₹1.4 L (59.1%)Rejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | L4 | Rejected-Finance That the Bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹4,848
Closing Date
5 Feb 2025, 1:00 pmClosed
Assistant Engineer, KMC Electrical Sub-Division
Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Repairing and SITC of Lightning Conductor system in Super Speciality Block Building under Medical College and Hospital Kolkata.
2025_WBPWD_797890_1
WBPWD/AE/KMCESD/NIQ-130/24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,848
15 Oct 2025
9 Jan 2025
7 Feb 2025
15 Jan 2025
5 Feb 2025
15 Jan 2025
Amount
Dismantling the old installation with company's own tools and tackles and take away scrap materials from site and deposit the necessary materials in store of site as per instruction of EIC.
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1). Vide pg no. J-1 item no. 1
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works. Vide pg no. J-1 item no. 9
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work. Vide pg no. J-1 item no. 11(a)
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:(Length upto 0.5 Mtr), Vide pg no. J-1 item no. 4(a)
Making soldered joints between conductors, conductors and air terminals for GI (Hot Dip) strips 20 mm x 3 mm thick incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint,
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run .Vide pg no. J-1 item no. 7
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of overhead reservoir (vertical run), Vide pg no. J-1 item no. 8
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire or GI (Hot Dip) strips 20 mm x 3 mm thick of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required. Vide pg no. J-2 item no. 13
Excavation of soil for installation of Earth Electrode and filling & ramming. For soft soil Vide pg no. G-1 item no. 1(a)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below(ISI-M) . Vide pg no. G-1 item no. 2(a)
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. Vide pg no. G-2 item no. 3(a)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
MOON LIGHT (BID ID -6087396)
A.K.ENTERPRISE (BID ID -6085436)
MAA TARA ENTERPRISE (BID ID -6051419)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .