| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L1 | Accepted-AOC Quoting lowest Ammount | |
| 2 | L2₹10.9 L+₹1.8 L (19.8%)Accepted-AOC | L2 | Accepted-AOC Quoting Lowesr Ammount | |
| 3 | L3₹13.3 L+₹4.2 L (46.1%)Rejected-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L3 | Rejected-Finance Quoting Higher Amount | |
| 4 | L4₹14.7 L+₹5.6 L (62.1%)Rejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance Quoting Higher Amount | |
| 5 | Rejected-Technical | - | Rejected-Technical Not found similar nature of work |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
10 Feb 2020, 3:00 pmClosed
Superintending Enginee
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Construction of new Youth Hostel, Bolpur, Birbhum- ----SITC of Fire detection system.
2020_WBPWD_267861_1
WBPWD/SEWEC /BRED /NIQ-47/2019-20_3rd Call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
60 days
Birbhum
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,000
Yes
Office of the Superintending Engineer, Western Ele
5 Oct 2020
22 Jan 2020
12 Feb 2020
22 Jan 2020
10 Feb 2020
25 Jan 2020
22 Jan 2020 - 24 Jan 2020
24 Jan 2020
Amount
Supply, Installation ,fixing ,testing and commissioning of Microprocessor based 3 loop capacity, Networkable analog addressable type fire alarm control panel with min 600 character LCD display integrated with Digital voice evacuation system. The panel should be equipped with sufficient numbers of loop with 20% spare capacity with each loop shall have a capacity of min 200 analog addressable devices in one loop. The panel should be fully field programmable using keypad. Panel should operate with 240 volts AC power supply automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 15min during an emergency conditions as required. The panel should have network card for panel networking & serial port to connect online printer.( UL 9th Edition Approved / VDS) ( Make: Honeywell / Notifier / Simplex / Siemens / Bosch )
Supply, Installation ,fixing ,testing and commissioning of Intelligent Addressable Microprocessor based Multicreteria smoke -heat detector with base with 360 degree viewing Alarm LEDs. The Detector should be intelligent automatic floating sensitivity adjustment type & can be programmed as heat mode. Code dail addressing( UL / VDS Listed) (Make: Honeywell / Notifier / Simplex / Siemens / Bosch )
Supply, Installation ,fixing ,testing and commissioning of Addressable very Intelligent early warning LASER detector with min 0.03% per foot obscuration level for server room, Liabrary & Control room. The detector should be intelligent to autometically self optimise its sensitivity & 360 degree viewing Alarm LEDs. Code dial addressing( UL / VDS Listed).( Make: Honeywell / Notifier / Simplex / Siemens / Bosch )
Supply, Installation, fixing, Testing and Commissioning of Fault Isolator module to isolate shorted desired and loose circuit between two successive fault isolators with automatic resetting arrangement. ( UL Listed ) ( Make: Honeywell/Notifier/Siplex/Siemens/Bosch )
Supply, Installation, fixing, Testing and Commissioning of addressable control module for the notification device. The module should monitor the cables for open and short circuit. ( UL Listed ) ( Make: Honeywell/Notifier/Siplex/Siemens/Bosch )
Supply, Installation ,fixing ,testing and commissioning of Intelligent Addressable PULL/Glass break type Manual call point with key arrangement to activate manual alarm. Code dial addressing( UL / VDS Listed)( Make: Honeywell / Notifier / Simplex / Siemens / Bosch )
Supply, Installation ,fixing ,testing and commissioning of Intelligent Addressable Indoor type directional sounders with strobe, shall be field programmable without the use of special tools, at a sound level of atleast 90 dBA measured at 10 feet from the devices per tender specifications, broad band directional sound with 20HZ to 20KHZ frequency band ( UL / VDS Listed).( Make: Honeywell / Notifier / Simplex / Siemens / Bosch / GE )
Supply & Laying of 2 Core 1.5 sq.mm shielded Cu Unarmoured cable through PVC regid pipe with all other accessories incl S & F of PVC pipe.(Make: As per choice of EIC)
Note: 1. The fire alarm system shall comply with latest requirments of--1. National Fire Protection Association (NFPA) standerds. 2. IS 2189. 3. NFPA 70 National Electric Code. 4. NFPA 72 National Fire Alarm code. 5. Manufacturer Recommendation
TESTS:1. The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturar of the fire alarm equipment to technically supervise and perticipate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuty, and insulation and other tests as per above standerds must be done.
SHANKAR BHATTACHARJEE
PERFECT IMAGE SOLUTIONS
ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .