Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC CHEGELI POTHER P O JIADHAL CHARIALI P S DHEMAJI DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | ₹3.2 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹3.2 Cr+₹6.5 L (2.05%)Rejected-AOC | ₹3.2 Cr+₹6.5 L (2.05%) | L2 | Rejected-AOC L2 |
Tender Value
₹3.1 Cr
EMD Value
₹6.2 L
Closing Date
21 Nov 2019, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Upgradation of existing Degree colleges to Model Degree Colleges under RUSA, Assam. Murkong Selek College Dhemaji dist.
2019_PWBNH_14630_1
UDC_4 Murkong Selek College
Open Tender
Civil Works - Building
Item Rate
545 days
Dhemaji
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,000
Assam State Road Board Maintenance (Road) Fund
₹6.2 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
1 Oct 2020
1 Nov 2019
22 Nov 2019
1 Nov 2019
21 Nov 2019
1 Nov 2019
11 Nov 2019
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinary soil
Earth/sand filling in plinth in layers not more than 1.50mm thick including necessary carriage, watering, ramming etc. complete as directed ans specified including payment of land compensation, forst royalty, sales tax and other duties and taxes as may be necessary With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Plain cement concrete works with coarse aggregate of size 13mm to 32mm in foundation bed for for foting steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) a) In prop. 1cement:3 sand: 6 coarse aggregate by volume
Plain cement concrete works with coarse aggregate of size 13mm to 32mm in foundation bed for for foting steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (b) In prop 1cement: 4 sand :8 coarse aggregate by volume
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary and curing etc. complete 50mm thick
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary and curing etc. complete 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In substructure up to plinth level. Foundation, footing, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining walls walls of septic tank, inspection pit and the like and other works not less than 100mm thick Without using admixture, plasticiser M20 or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In superstructure from plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and suport, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staricase including preparing of top surfaces and furnishing and nosing. Without using admixture, plasticiser M20 or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement with coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) Using mixture machine In superstructure from plinth level up to 1st floor level. i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. Without using admixture, plasticiser M20 or Prop. 1:1.5:3
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1: - Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25 mm thick plank.
Sides of tie beam, plinth beams, grade beams etc. at or below plinth level. Using 25mm thick plank..
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, pillars, posts & strut Square, Rectungular, polygonal in plan or any shape like Tee/ L etc. having plane vertical face.
Sides and Soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. For depth not exceeding 1.0m
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
Providing brick soling in foundation and under floor with stone/best quality picked Jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete. a) Brick on flat soling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary In proportion 1:4.
Extra over item no. 4.1.5 above for brick work in each subsequent floor or part thereof above 1st floor level.
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure (I) In Sub-structure upto plinth level including dewatering if necessary (a). In proportion 1:3.
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure (II) In superstructure above plinth level up to 1st floor level. (a). In proportion 1:3.
Extra over item no. 4.1.6 (II) above for brick work in each subsequent floor or part thereof above 1st floor level.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) 112mm thick brick wall In cement mortar 1:4
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. 20 mm thick
40 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.
65 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.
Pre-cast cement concrete tiles 20 mm thick with aggregate of sizes up to 6 mm laid in floors, treads of steps and landing with 20 mm thick bed of cement mortar in prop. 1:6 (1cement : 6 coarse sand ) joined with neat cement slurry with pigment to match the floor. (a) Any shade or combination of shades using white cement.
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/ Johnson Make ii) Of size 600mmx600mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On fair side In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15 mm and finishing coat 5mm thick) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. ii) 15 mm thick plaster b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed. a) On Single coat plaster
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 15 mm thick
Providing wattle/spilt bamboo ceilling 15mm cement plastered at top in proportion 1:10 and markin cloth at bottom fitted with 38mm x12mm 1st class hollock/ bonsum/ sundi timber beading chamfered and finished with 2 coats of chalk washing to the markin cloth and 2 coats of enamel painting to timber beads complete (timber ceilling joists to be measured and paid separately).
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). 12.50 mm thk
Providing circular corrugated / trouhed Everlast Aluminium roofing sheet of Aluminium Alloy procured from primary aluminium producer (On submission of certificate of alloy purchasing from primary producer) including fitting and fixing necessary J or L hooks bolts and nuts 8 mm dia with bitumen / EPDM washer 25mm dia x 3mm thick and 1.6mm limplet washer complete excluding cost of truss, purlin etc. Everlast/ Paragon make or equivalent Quality as directed by the departement (b) 0.50mm thick
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement 0.60 mm thick
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (d) With Bola timber
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
Providing fitting and fixing 1/3 panelled 2/3 glazed wooden shutters for doors/windows including oxidised iron butt hinges (100mm x75 mm x3.55 mm) with necessay screws including glass panes (other fittings to be measured and paid separately) B) With 1st class local wood (Gamari/Hollock/Bonsum) (iii) 30 mm thick.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. Decorative type face panel and block board core. 35 mm thick
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (iii) 30 mm thick .
Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately). 1.60mm thick sheet of Size 105mm x 60mm (Single rebate)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. Plain grill Fixed to Brickwork/ P.C.C/ R.C.C.
Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 2 Track sliding window - 5 mm clear glass
Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 2 Track sliding window - 5 mm frosted glass
Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 3 Track sliding window - 5 mm frosted glass
(a) White washing with lime on wall surfaces (two coats) to give an even shade including throughly brooming the surface to remove all dirt, dust,mortar drops and other foreign matter.
c) Applying one coat of distemper primer of approved brand and manufacture on wall surface after throughly brushing the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Providing two coats of Birla white wall care putty (Water resistant white cement based putty for concrete/mortar walls and ceiling both internal & external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean wqater as specified and directed by the department.(Total thickness of two coats is maximum 1.5mm) Thickness = 1.0 mm
a) Removing dry or oil bound distemper by washing and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete.
Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give and even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth. Priming coat with distemper primer
Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give and even shade, over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth. Top coat
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. Surfaces over 100mm in width or girth - General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint).
Finishing old/new wall with waterproofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels. (two coats)
Supplying, fitting, fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete. (anodised to bright natural matt & stain finished) Sliding door bolts - 300mm x 16mm.
Supplying, fitting, fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete. (anodised to bright natural matt & stain finished) Tower bolts - 250mm x 12mm
Supplying, fitting, fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete. (anodised to bright natural matt & stain finished) Door handles - 150mm
Supplying, fitting, fixing anodized aluminium fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete. (anodised to bright natural matt & stain finished) t) Door stopper with rubber stopper
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
Providing welding, fitting, fixing, hoisting and fixing of roof trusses of TATA make with purlin, bottom runner etc. fabricated out of a combination of two or all of the following sections: (i) Square Hollow sections (ii) Rectangular Hollow section od specification RHS/SHS Grade YST 310 conforming to relevant I.S. code 4923:1997 and (iii) M.S. black-tubes of Grade YST 210 conforming to relevant I.S. code 1239 as per approved design and drawing including M.S. cleat, base plate, bolts and nuts which ever required, including that required for fixing the ceiling and one coat of red oxide Zinc Chromate primer to all steel surface etc. complete as directed as per specifications. Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing wood work in frame of ceiling partitions etc.sawn, wrought, framed hoisted and fixed in positon with spikes, nails, M.S flat,angle/ cleats with bolt and nuts complete including kiricide oiling two coats to unexposed surfaces of the timber (M.S flats, angle cleats, and bolt and nuts required for flat, angle cleats wherever necessary shall be measured and paid separately) With sal wood
Providing, fitting and fixing hard board sheet ceilling with approved quality with necessary nails, wood screws including 1st class local wood 50mm x 12mm ( hollock/ bonsum/ sundi ) beading including paining two coats to timber beads complete as directed ( ceilling joist to be measured and paid separately). 4.5 mm thick
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel/ RINL (ii) Super Ductile (SD) TMT reinforcement bars
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) Other ISI approved TMT reinforcement bar (SAI/ BISCON/ THERMAX) (For Assam Type Bldg., drain works, retaining wall & boundary wall etc.
Providing nad fixing MS fan clamp type I or II of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs or beams during laying including painting the exposed portion of loop all as per standard design complete
Providing plinth protection with brick flat laid in cement mortar 1: 4 and finished with 15 mm thick cement plaster in prop 1:2 with a floating coat of neat cement finish.
Providing drain with cement conc. (1:3:6) 100 mm thick sides and 100 mm thick bed over brick flat soling including 15 mm thick cement plaster in prop 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300 mm wide and average 250 mm deep with bed slope 1 in 150 with initial depth of 100 mm .
Extra for providing and mixing Integral waterproofing compounds like Master Proof IWP-1 of Choksey Chemicals /Dr. Sealkit No.1 (Asian Chemicals)/ RHEOMAC 707 of BASF @ 0.2% by weight of cement for waterproofing structures like roof slabs, basement, sunken slabs, chajjas, tunnels, water tank etc. as specified and directed by the Department complete at all levels. A. In concrete of proportion: (iii) 1 : 1 : 2 (1cement : 1coarse sand : 2aggregate) or M-25 grade.
Demolishing lime concrete without damaging the structure and disposal of debris as directed at all levels
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling of existing steel windows/ steel ventilators/ steel windows and steel ventilators without damaging the walls, removing to a safe place and necessary repairs to the edges of walls.
Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levels
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Construction of Sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth ). (Including cost of testing of materials at site and laboratory as directed by the deptt.) a) from Private land
Construction of Granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause 401 of MoRTH specifications (with an initial lead of 5 km) (including cost of testing of materials at site and laboratory as directed by the deptt.) (a)Using Grading I material
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
Supplying fitting and fixing P.V.C. pipes of 6 kg f/cm2 (Supreme /Prince) and other ISI approved including joining, fitting and fixing with clamps etc as necesary complete at all levels including below G.L as directed and specified In Exposed surfaces or in trenches - 110 mm dia,
Supplying fitting and fixing P.V.C. pipes of 6 kg f/cm2 (Supreme /Prince) and other ISI approved including joining, fitting and fixing with clamps etc as necesary complete at all levels including below G.L as directed and specified In Exposed surfaces or in trenches - 75mm dia.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls - 40 mm dia (Medium) - Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls - 25 mm dia (Medium) - Using Tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. Exposed on walls - 20mm dia (Medium) - Using Tata make
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) Parryware Make, - White Duke 660 x 495 (Cat. No.C8416/27) (white/ coloured)
Item No.1.2. - Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) White - Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) Parryware make - White - )Economy Single Flush (Cat No.C8090/C8055)
Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware Make - White (Cat. No. C0503)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware Make - White - New Magnum (Cat. No.C0575)
Supplying , fitting and fixing C.P. bib cock 15 mm dia of approved brand directed and specified. (G.I & C.P pipes will be measured separately) Jaquare make - Continental /Clarion - Standard
Supplying, fitting and fixing C.P. pillar cock 15 mm dia of approved brand as specified and directed Sona make - Heavy type
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar a) Continental/ Clarion) - 15mm dia (Angular stopcock)
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. Jaquar Make - Queen's (Cat.No.AQN-7731)
Providing, fitting and fixing CP towel rail complete as directed and specified. Sona make - Towel rail Diplomat 600mm long (Cat.No.TR-0605)
Providing fitting and fixing Decorative Mirror complete as directed and specified. Parryware Make - Size 600mm x 450mm
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately) Jaquar make - Continental - Overhead shower (ABS chrome plated) with rubit cleaning system
C.P. Grating - 110mm dia
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose etc. complete Short point up to 3.00 metre. length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 amp flush type 2 way switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Long point up to 10.00 metre. Length.
Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp
Supplying and fitting of 11/15 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way SPN single door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make) 4 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make) 8 way SPN double door
Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) single door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 63A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 160A
Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Standard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic - Power Flow 225 mm sweep (ORIENT make)
Supplying, fitting & fixing of Electronic Regulator as required complete
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 1-2 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 3 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 6 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department. 12 module type Metal
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) front plate of suitable colour as per direction of department. 3 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) front plate of suitable colour as per direction of department. 6 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE (MURANO) front plate of suitable colour as per direction of department. 12 module
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6 Amps 3 pin universal combine shuttered complete , MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of 10/16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
PrasantaGogoi
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .