Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹119.9 CrAccepted-AOC | ₹119.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹142.7 CrRejected-Finance RAM PLAZA NAVASHAKTI CHOWK BHABHA NAGAR NASHIK 422 011 | NASHIK | NASHIK | MAHARASHTRA | 422011 | ₹142.7 Cr | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| 5 | Rejected-Technical | - | - | Rejected-Technical technically not qualified |
Tender Value
₹114.2 Cr
EMD Value
₹57.1 L
Closing Date
4 Oct 2023, 6:30 pmClosed
EXECUTIVE ENGINEER INTEGRATED UNIT (M)P.W.NAGPUR
OFFICE OF THE EXECUTIVE ENGINEER INTEGRATED UNIT (M)P.W.NAGPUR, T.B. WARD PREMISES NAGPUR
CONSTRUCTION OF 500 BEDED HOSPITAL INCLUDING ELECTRIFICATION (MEDICAL COMPLEX) AT INDIRA GANDHI GOVT. MEDICAL COLLAGE AND HOSPITAL NAGPUR. (G PLUS 7)
2023_PWR_938785_1
pwc/ngp/IUM/20-1/2023-24
Open Tender
Civil Works - Buildings
900 days
MAYO HOSPITAL PREMISES NAGPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
₹57.1 L
Office of the C.E. P. W.Region, Civil Lines Nagpur
21 Mar 2024
25 Aug 2023
6 Oct 2023
25 Aug 2023
4 Oct 2023
25 Aug 2023
6 Sept 2023
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (A) Lift upto 1.50 m, including transportaion of excavated material
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete (B) Lift above 1.50 m to 3.00 m including dewatering & transportaion of excavated material
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.00m to 4.0m) By Mechanical Means
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
Prividing and fixing pressure relief pipes of 110 mm diametre of PVC as per drawing for R.C.C Raft, galaries returns, abutments, wing wall etc complete.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (A) FOR M30 CONCRETE
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
(A) GROUND FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and applying required coats of a water based Evercrete Deep Penetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reduce the curing period etc complete. - Note -- for item One Number 7 to 4 prior approval of Superintending Engineer will be necessary
(A) GROUND FLOOR
(A) FIRST FLOOR
(I) TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(H) TERRACE FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) (A) GROUND FLOOR
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Labour charges for providing groove in external plaster having width and spaced as directed by engineer incharge etc. complete.
(A) GROUND FLOOR
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
PRIVIDING AND FIXING ACOUSTICAL FALSE CEILING WITH 0.9 NRC: Sierra Mineral Fibre Acoustical Suspended Ceiling System with 15mm thick Sierra OP Tegular 15/90 Edge Tiles with Suprafine 15mm face exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.90 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 25db as per ASTM E1414, Light Reflectance ≥86% as per ASTM E-1477, Thermal Conductivity λ = 0.040 W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 15mm Tegular 15/90˚ edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable and classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 43% and VOC Emissions (French) class of A+. The tile shall have Environmental Product Declaration as per ISO 14025 and EN 15804+A2. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on Suprafine 38 with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a
(H) SEVENTH FLOOR
FALSE CEILING SYSTEM GI METAL BIOGUARD CLIP IN PLAIN TILE WITH CARRIER SYSTEM 600 X 600MM Providing & Fixing horizontal level suspended ceiling comprising of GI Bioguard Clip-in Plain Tile 600x600mm (Nominal Size) tiles of 120 gsm galvanized steel as per IS 277 (2003) suitable for architectural finishes in 0.5mm thickness as per in IS:513 (1994) in Global white color with concealed suspension system having a bevelled edge of 3x3mm and height of 33mm on one side and 18mm on the other side. Tiles shall be flattened by precision leveller to minimize sag to less than 1/400mm. The tiles shall have double round pip of ɸ 2mm and ɸ 6mm for secure engagement and levelling respectively, along with swing down feature and special tabs to allow removal of tile to enable plenum access. The coated surface of the tile shall exhibit anti-microbial properties (eradication and inhibition of growth) and shall achieve up to 99.99% reduction in bacterial activity as per ISO22196:2011. The tile shall be electrostatically polyester powder coated using RoHS compliant powder having coating thickness ranging from 60-80 microns. The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The tile shall have scratch, mar & abrasive resistance properties. The tile shall have a Light Reflectance of ≥ 63% in accordance to ASTM 1477-98 and Fire Performance of class 0/1 as per BS 476 Part 6 & 7 in module size of 600x600mm. SUSPENSION & INSTALLATION: Shall comprise of 3000mm long ‘C’ channels of 38H x 12W mm and 1mm thick spaced at 1200mm centre to centre securely fixed to the structural soffit using threaded rod (Approved make/Third Party Supply) connecting to C- channel hanger of 109x18.5x16.5mm at 1200mm C/C and anchor fastener (Approved make/Third Party Supply). The last hanger at the end of each C-channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector of 99.5x35x 9mm for splicing together two pieces of C-channels. 4000mm Clip-in bar of 16W x 40H mm
(A) GROUND FLOOR
(B) FIRST FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
PRIVIDING AND FIXING ANTIMICROBIAL ACOUSTICAL FALSE CEILING: Bioguard Mineral Fibre Acoustical Suspended Ceiling System with 19mm thick Acoustics Microlook 90 Edge Tiles with 15mm face exposed grid. The tiles shall have smooth bright laminated visual with Humidity Resistance (RH) of 99%, NRC 0.7 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 41db as per ASTM E1414, Light Reflectance ≥87% as per ASTM E-1477, Thermal Conductivity k = 0.052 - 0.057 W/mK, Colour Global White, Fire Performance of Class 0/1 as per BS 476 Part6/7 and Class A as per ASTM E 84 with 19mm Square Tegular/Microlook 90˚ edge and 8mm drop in module size of 600 x 600mm./ 600x1200mm. The scrim on the face of the tile shall be cleanable, washable up to 500 cycle as per ASTM D-4828 and resistant to disinfectants. The tile shall be treated with Anti Microbial coating on the face of the tile to achieve cleanroom classification of class 5 (Class 100) as per ISO 14644-1 and suitable for zone 4 area having partical emission under normal conditions of ISO 5, Decontamination Class of CP10 and Bacteriological Cleanliness Class B1 for specific strains as per NF S 90- 35:2003 The tile shall have a rating of 8 or above (face) for tests conducted for Resistance to growth of Mold in accordance to ASTM D3273. It shall be suitable for Green Building application, with Recycled content of 35% having VOC and Formaldehyde emission rate less than 0.1mg/m2/hr. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than
(C) SECOND FLOOR
CHANNELLED WALL PANELLING OF SIZE: 192X2400X15MM Providing and Fixing Channelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm or 21mm of visible pane (G-13/ G-21). The edges of the panel shall be “tongue-and- grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. for G-21 and 0.6 for G-13. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mOne Metric Tonnehe panels shall be mounted on special aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge.
(H) SEVENTH FLOOR
ACOUSTICAL WALL PANELLING – FABRIC WRAPPED OF SIZE: 600X600/1200X25MM Providing and Fixing of Acoustical Wall Panel with square edges made of fibre glass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as per the approved shade (Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) with 50mm airgap as per ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers (supplied by the manufacturer) or by using construction adhesives (as per the instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%.Installation:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4 nos. in case of 600x1200mm. Silica based construction adhesive (by others) to be dabbed on to the projecting elements (spikes) of the Impalers. Wall Panels shall be pierced through the spikes of the Impalers ensuring the line and level of the panels are maintained
(H) SEVENTH FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and applying impression 24 carrat Luxury paint of approved make & approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surface in two coats, including sub surface prparation by Acrylic putty and Acrylic primer coats including scaffolding, preparing the surface. etc. complete (Low VOC).
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.
(H) SEVENTH FLOOR
Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
(A) GROUND FLOOR
(H) SEVENTH FLOOR
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 125 mm
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
(A) GROUND FLOOR
Providing and fixing the Country cut teak wood second class fully glazed openable fanlight rectangular in shape as per detailed drawing excluding the frame,stainless steel fixtures and fastenings and finishing the wood work with 3 coats of oil painting.
(A) GROUND FLOOR
Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Solid Core Flush door Double leaf Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and Fixing 32 mm thick One piece single moulded puff ABSTRONE BUTADYNE STYRINE (ABS) Door shutter for internal use including toilets made up of outer ABS sheet of 1.2 mm thick having puff insulation of 35 to 40 Kilogram/One Cubic Metredensity and 10 mm dia.for steel bars 2 Nos., wooden block to receive fixtures, having M.S. hinges 100 mm length, M.S. handles 150 mm length and 10 mm dia sliding door bolt etc. complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I.section 1.5 mm, wherever required. uPVC window & door profile shall be made in India& shall conform to BS EN 12608 and other standards as mentioned below: S.No.Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 VicatSoftening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be fusion welded. After placing 5 mm Float Annealedglass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall beprovided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and DoorProfiles are warranted for a period of ten (10) years against non-uniform discoloration,wrapping and rotting under general use.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing inC.M. 1:3 curing and cleaning etc. complete.
(A) GROUND FLOOR
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(H) TERRACE FLOOR
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and laying vitrified rustic matt stone finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm to 8 to 10mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning. etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make (such as Master Seal 550/ brush bond / RoffSupercrete / Webercrete / Monobond /Perma shield / Hypercrate / Master Crete M 81) and Cement in 1 : 2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned and dust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, sprinkling coarse sand over it, followed by protective mechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compound of approved make and polypropylene fibres @ 125 gm per bag of cement making groovr 3 to 4 mm wide & 10 mm deep in concrete, in pannels of 3m/4m or as per site condition & filling the joints with poly sulphide sealant after curing including providing holler with drip moulds at the junction and finishing the concrete surface with neat cement slurry, as directed and ponding the surface as directed etc.complete ; covering 10 years guarantee against leakproofness on court Fee stamp paper of Rs 100/-
(A) GROUND FLOOR
(H) SEVENTH FLOOR
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing Exterior grade fabricated fibre reinforced heavy duty cement concrete tiles of approved colour and design, 22 '+- 2 mm thick, bayer colour pigmented as per IS:1237-1980 reaffirmed in 2006, having compressive strength more than 500 kg/sqm like ultra tiles or equivalent, in plain/designed pattern on a bed of 1:6 cement morter including cement float, filling joint with neat cement slurry, curing etc complete. For flooring
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre)
(A) GROUND FLOOR
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete or/B.B.masonry and or tying by binding wire etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and Fixing Sun Louvre panels roll formed, 0.6mm thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineer in Charge.
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat and smoke resistant composite Fire check Door Shutter complying with with fire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in vaccum pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to 810 Kilogram/cum) frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128 Kilogram/cum), vermaculite mix faced with 3mm Fire retardant High Density fibre board, internally lipped with hardwood beading and pasted in Hydraulic Press under 25 MPa, spray quoted with 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
c) Vision Panel:2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with U- glazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing of 2 Hour Rated Acoustic Fire Door to effectively control noise in conference rooms, broadcasting studios, theatres and music practice rooms. duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The accoustic fire doors are tested with NCBN technology ("Non Combustible by Nature") duly tested for sound insulation as per ISO 10140-2 / ASTM E 90 for sound transmission loss evaluation of 42db in reverberation chamber at ARAI.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self- drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.
(H) SEVENTH FLOOR
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete
(A) GROUND FLOOR
Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Spec.No.: As directed by Engineer- in-charge . CC ROAD
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader / Paver on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- By Mix in Place Method and Grading - I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means -Grading I (Using Screening Type B (11.2 mm) Aggregate)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate)
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not e
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etc. complete. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete.
Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm. .in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge.
Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (appraox. 25% larger than the initial 3 mOne Metric Tonneo 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer.
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer) with SCADA
Providing and laying in situ cement concrete of 1:4:8 proportion with trap/ granite/ quartzite/ gneiss metal in foundation including necessary form work, compacting and curing etc. complete. (with reversible drum type mixer with SCADA
Providing, cutting, bending, hooking, tying and laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete.
Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.
Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015).
Providing and fixing cautionary / warning sign board of size 60 cm. having shape of equilateral triangle with apex point upwards. prepared on 16 gauge M.S. sheet including painting with one coat of zinc cromate stoving primer and two coats each of white back ground, red border and backside gray stove enamelled, bonded with cut out of Retro reflective sheet Engineering grade, symbol / letters / numerals / border / arrow, coated with non pealable crystal clear protective transparent coat retaining 100% reflection including one One Number of M.S. Angle iron post of size 50 x 50 x 5 mm of 3.65 m. long inflated at bottom drilled on top in one piece without joint painted with white and black bands of 30 cm. fixing board and post with 2 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size etc.complete. 60 cm. equilateral triangle M.S. sheet with Engineering grade,
Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas, spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete.
Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete.
Removing cloth ceiling including frame work and stacking the materials as ditected with all leads, lifts etc. complete
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc.
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete.
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete.
Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Spec.No.: As directed by Engineer- in-charge .
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (160 Kilogram)
Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing Orissa type white glazed earthenware water closet pan of size 260mm x 440mm x 580mm with approved make Slim wall hung cistern with installation kit including S or P trap with cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc.complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate upto 6.0Litr/Minute, C.P .Angular stop cock long thread of Jaquar / Cera / Hindware / Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer incharge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer Incharge
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by In charge
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness1.5mm of the approved brand and make.
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 10.15 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floors, 100 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
Providing and fixing on walls/ceiling/floor 20 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 25 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 32 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete
(B) FIRST FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(C) SECOND FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
(I) TERRACE FLOOR
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
(H) SEVENTH FLOOR
Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
(H) SEVENTH FLOOR
Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
(H) SEVENTH FLOOR
Providing and fixing screw down for 65 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
(H) SEVENTH FLOOR
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete
(H) SEVENTH FLOOR
Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc.complete
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
(A) GROUND FLOOR
(B) FIRST FLOOR
(C) SECOND FLOOR
(D) THIRD FLOOR
(E) FOURTH FLOOR
(F) FIFTH FLOOR
(G) SIXTH FLOOR
(H) SEVENTH FLOOR
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete.
(A) GROUND FLOOR
(H) SEVENTH FLOOR
Providing and fixing 100mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangements and lock. [Without chamber].
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 600mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete.
RWH - Recharge PitProviding and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and laying in trenches 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 12.43 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti- corrosive oil paint , 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Drilling of Bore well by reverse rotary method in all types of strata 400 including all charges ---------- etc. complete.
Providing and fixing 150 mm dia M.S. casing pipe class B 4.80 mm thick as per IS 1239 (Blank)
Yeild test by Air lift Metod with 90 cone "V" notch.as directed
Testing Charges For Borewell Point
Royalty for Sand
Royalty for 80 mm metal
Royalty for Murum
GSB Mix Design./Cement Treated Sub Base ( CTSB)
Sieve Analysis.
Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness.
Concrete Mix Design (With all Tests on basic materials)
Compressive Strength OF C.C. Cube (Set of 3 cubes).
Stel Upto 16 mm (Set of 3 Bars)(Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Above 16 mm (Set of 3 Bars) (Set of 3 Bars)(Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
Fineness Modulus ( Sieve Analysis ),Silt & Clay Content
Chloride & Sulphate Content.
Silt Factor.
Water Absorption, Specific Gravity,Impact Value, Crushing Value.
Sieve Analysis.
Abrasion Value.
Flakiness Index & Elongation Index.
Stripping Value. (for Bituminous Work)
Soundness.
Compressive Strength , Water Absorption,(Set of 8 Blocks)
Crushing Value/Compressive Strength, Water Absorption & Specific Gravity,
MURUM Liquid limit & plastic Limit.
VETRIFIED TILESWater Absorption, Modulus of Rupture (Set of 6 Tiles)
BRICKS Compressive Strength
BRICKS Water Absorption
Water PH Value, Sulphate & Chloride Content
Teak wood Density, Moisture Content.
Flush door Knife Test, Adhesion Test, End Immersion Test
GI Pipe Weight per running meter,Diameter of pipe & wall thickness of pipe,
P.V.C. PIPES (NONPLASTISIZED)Weight per running meter,Diameter of pipe & wall thickness of pipe
NON -DESTRUCTIVE TESTRebound Hammer Test.
CONCRETE Flexural strength of Beam
Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 6 way outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 2 nos. feeder with 2 LBS and 4 nos. feeder with 4 VCB compliant to IEC 62271 -100, 200 and 102, as per specification no. SW-HTS/RMU SCADA
Supplying, erecting, testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by Power Supply Agency / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paint of required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, and provision for incoming and outgoing cables complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 1000 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound ,without gas cushioning ,hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2790 Watts at 50% load, 7700 Watts at 100% load as per IS:1180 (part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 500 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 81.90 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 690 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspector as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of Microprocessor based Generator Control Unit (Synchronization panel) panel suitable for diesel generating set of above 400 kVA up to 500 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features and safeties etc as per specification no. GEN-SYNC.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying, installing, testing and commissioning FR, XLPE armoured cable 4 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting & terminating FRLS XLPE armoured cable 3½core 400 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE armoured cable 3½core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE armoured cable 3½core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE armoured cable 3½core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE armoured cable 3½core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rate by 2 %
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 %
Supplying, erecting & terminating FRLS XLPE insulated unarmoured cable 1100 V. 1 core 120 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rate by 2 %
Supplying, erecting & terminating FRLS XLPE insulated unarmoured cable 1100 V. 1 core 150 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel /distribution boards / pipe as per specification no. CBLT/CU
Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU Note: For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rate by 2 %
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 having 2.5 mm thickness up to 11 Kv
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution,etc. (All above contents shall be of standard makes)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles ( except hollow core conductors). The residual openings shall be closed with filler, as per specification no FF-FRM.
Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544 duly tested, with necessary test certificate from manufacturer.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting square shaped 600x600mm 36W LED Clean Room Panel Light.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected,complete.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc.
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface.Design,fabrication,assembling,supply,installation,testing and commissioning of cubicle type LT panels suitable for 415 V 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentised design from CRCA sheet steel of 2 mm thick for frame work IP 52 and covers,3 mm thick for gland plates i/c cleaning and finishing complete 9 tank process for powder coating in approved shade RAL 7032, extendable type TPN aluminium alloy busbars of high conductivity,DMC/SMC busbar supports,with bottom base channel of MS section not less than 75mm X 50 mm X 5 mm thick,entire panel shall have a common copper earthbar of required size at the rear with 2 nos earth studs,solid connection from main busbar to switchgears with require size of aluminium busbar & control wiring with 2.5sqmm FRLS insulated copper conductor cable ,cable alleys ,cable gland plates i/c accessrories as per specification and providing switchgears, metering instruments etc. for follwing panels.
Main LT Panel - 1 & 2MAIN PANEL 1 & 2 (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 1600A FP EDO MP based ACB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter.,with standard accessories and thermal magnetic release on provided iron frame as per specification no. SW-SWR/ACB BUSBAR: 1600A, 50kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: (50kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter. 2 No : 1600 Amps FP MP EDO ACB, 50kA with E/F protection & RS 485 port
PCC Panel MAIN PANEL (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 2 No - 1600A FP EDO MP based ACB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 1600A, 50kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. BUSCOUPLER: 1600A FP EDO MP based ACB of fault breaking capacity 50 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. OUTGOING: (50kA Ics=Icu=100% upto 433V) with on/off/trip indication lamps & multifunction meter. 4 No : 800 Amps 4P EDO ACB, 50kA with E/F protection 1 No : 800 Amps 4P EDO ACB, 50kA with E/F protection 1 No : 800 Amps 4P TM MCCB, 36kA with E/F protection 2 No : 630 Amps 4P TM MCCB, 36kA with E/F protection 3 No : 400 Amps 4P TM MCCB , 36kA with E/F protection 1 No : 160 Amps 4P TM MCCB, 36kA with E/F protection 4 No : 63 Amps 4P TM MCCB, 36kA with E/F protection
Main UPS Panel Main UPS Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.)INCOMER: 1 No - 630 A FP TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 36 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter.BUSBAR: 630A, 36kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar.OUTGOING: with on/off/trip indication lamps & ammeter.2 No : 315 Amps FP TM based MCCB, 25kA 2 No : 200 Amps FP TM based MCCB, 25kA
UPS Panel - 1 (GROUND FLOOR)UPS Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 200 A FP TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 200A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 2 No : 100 Amps TPN MCB, 25kA 1 No : 63 Amps TPN MCB, 16kA 3 No : 32 Amps TPN MCB, 10kA
UPS Panel - 3 (SIXTH FLOOR)UPS Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Master SLD.) INCOMER: 1 No - 200 A FP TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 200A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 2 No : 100 Amps TPN MCB, 25kA 4 No : 32 Amps TPN MCB, 10kA
UPS Panel - 2 (THIRD FLOOR)UPS Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 315 A FP TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 315A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 5 No : 100 Amps TPN MCCB, 25kA 1 No : 63 Amps TPN MCB, 16kA
EQUIPMENT PANEL EQUIPMENT Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.)INCOMER: 1 No - 800 A FP TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 36 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter.BUSBAR: 800A, 36kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar.OUTGOING: with on/off/trip indication lamps & ammeter.10 No : 250 Amps FP TM based MCCB, 36kA
LIFT PANEL (Indoor Type)Lift Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 160 A TPN TM based MCCB with O/L, S/C, E/F & RS 485 port, of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 160A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 8 No : 63 Amps FP MCB, 10kA
APFC PANEL Supplying and erecting 400 kVAr, 3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP /APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
LIGHTING PANEL Lighting Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 100A FP TM based MCCB with O/C, S/C of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 100A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 6 No : 40 Amps TPN MCB, 25kA
POWER PANEL Power Panel (As Per IEC 61439 1 & 2 & Other Standards As Mentioned in Tender Specifications & Master SLD.) INCOMER: 1 No - 200 A FP TM based MCCB with O/C, S/C of fault breaking capacity 25 KA (Ics=Icu=100% upto 415 V) with R-Y-B & On/off/trip lamps, ammeter, voltmeter & multifunction meter. BUSBAR: 200A, 25kA FP Aluminium Busbar with heat shrinkable Sleeves with copper earth bus bar. OUTGOING: with on/off/trip indication lamps & ammeter. 6 No : 63 Amps TPN MCB, 10kA
Supplying, erecting ,Testing & commissioning Ceiling or wall Mounting type 800A Capacity at 400C ambient temperature Sandwich type Aluminium Conductor tin plated at joints /Aluminium conductor Silver flashed copper bimetal contact having purity not less than 99.6% with suitable for (3L+ N) 415V, 50 Hz A.C Supply with 100% Neutral+ enclosure as integral earth (PE) with IP 54/55 Protection,42/50KA short circuit rating for 1sec, Insulation Class F (155 C) , casing made of minimum 1.5mm hot / electro Galvanized /Epoxy powder coated steel sheet enclosure with required shade of paint having Mechanical strength certification up to IK10 overall cross sectional area not more than 0.0170 sq. Mtr., complete assembly must comply to seismic zone 4, with necessary accessories Like suspension bracket, wall bracket holder/ fixing accessories as per site requirement with Horizontal / Vertical G.I. Support at required interval with Double run External Double run 50x5mm Aluminium earthing strip or Internal Integral Earth complete confirming to IEC 61439-6 as per specification
Supplying, installing & Commissioning Vertical or Horizontal 90 Degree Elbow for Sandwich type Aluminium Compact bus trunking/ rising mains Suitable for 630A, 3 Phase 4 Wire 415 V, 50 Hz AC Supply, 36/40kA short circuit rating for 1 sec Made of minimum 1.5mm Thick Galvanised sheet metal enclosure (IP54/55) duly powder coated with all necessary accessories complete confirming to IEC 61439-6 as per specification
Supplying, installing, testing and commissioning of Flange end with Adaptor box, as per site requirement suitable for Aluminium 630A 3 phase 4 wire 415V, 50 Hz A.C ,36/40kA short circuit rating for 1 sec Sandwich type Aluminium BBT. with necessary accessories complete
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB 415V, 200A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 32A to 125A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying, installing, testing & commissioning of Tap off box with interlock arrangement on existing Air Insulated / Sandwich type bus trunking/ rising mains for 125A to 200A 3 phase 4 wire 415V, 50Hz AC Supply made with High Grade Plastic enclosure with provision of MCB/ MCCB without (MCB/MCCB) complete as required confirming to IEC 61439-6 as per specification
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways /phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW RCCB/RCCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting and marking four pole isolators only switch version of miniature circuit breakers of 63A in provided distribution board.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Providing & erecting 4 Pole MCCB, 415V, 400A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note:- 1) For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB.
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB complete. (For UPS incommer & outgoing)
Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB. (For UPS incommer & outgoing)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG PW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW
Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting H.M.S. P.V.C. conduit 20 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying, erecting & commissioning MDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete. Add Note No.1 &2 (1 No Each ) Note :- 1) Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX 2) Add Rs. 19032.00 for additional 8 extension card for digital (hybrid) type EPABX
Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete
Supplying, installing, testing & commissioning IP telephone instrument as per specification complete.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying & installing expansion cabinet for extension of digital hybrid EPABX to expand system by 32 ports with programming and configuration of extensions and Direct lines with required accessories complete.
Supplying & erecting 20 pair, 0.5 mm dia. jelly filled armoured telephone copper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed having laid in provided trench as per specification No. WG-TW
Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW
Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG11 as per specification No. WG-TW
Supplying and erecting modular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WGNWC/GBS
Supplying & fixing 24 port Patch Panel with tool less keystone jacks in provided U Rack complete as per specification no. WG- NAS/PP
Supplying and fixing 12U floor mount rack (Dimension-DxWxH – 800x600x954mm) as per specification No. WG-NAS/RAK
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing dual-band POE 3x3 Mesh Router, 802.11 n/ac, standalone/software based access point complete.
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 01 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 100 mm height comprising all required standard accessories.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.
Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX.
Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WGMA/ BOX .
Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Making trench in soft soil having 0.9m depth and minimum 0.3 m width as per IS for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 5.625 KW/7.5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 57 to 22 m and discharge from 120 to 900 litres. . per minute & pipe of Suction 75 mm/Delivery 65 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting 65 mm dia. ball type foot valve having CI body lined with FRP from inside and synthetic rubber coated reinforced, nitrile rubber 358ball, leaded fin bronze, FRP sheet, carbon steel fasteners, CI/MS strainer complete.
Supplying and erecting ISI mark GI pipe 65 mm. dia. ‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification no. APWCR/ WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supply, Installation, Testing & Commissioning of following Chillers:The water chilling machine shall consist of Rotary/Scroll compressors connected in tandem/trio, squirrel cage induction motor, star delta starter, electronic expansion valve, brazed plate heat exchanger- Evaporator, precharged with eco-friendly R410a Refrigerant Gas. Chillers must have BEE (Bureau of Energy Efficiency) star labelling. Refrigerant piping, wiring and automatic controls all mounted on a common steel frame, factory charged refrigerant gas and oil, anti vibration rubber pads and other accessories factory assembled and tested. Machine shall be designed for tropical climate & multiple start-ups. Refrigerant circuit mist include Refrigerant liquid flow indicator, Solid cartridge Freon filter drier, HP and LP safety pressure switch, Solenoid valve for shutting off the refrigerant liquid, Compressor suction and delivery valves, Shut-off valves, Charging valve, Safety valve - Pressure relief valve, Crankcase heaters for compressor, Pressure transducer for compressors, external temperature probe, Maximum and minimum voltage relay, RS 485 serial connection card for ModBus output - BMS connectivity, Set point compensation depending on external air temperature, Double set point from digital input. Unit should be complete with Condenser Coil with Copper Tubes & Aluminium fins, Axial fans with direct drive AC motor and Electronic Fan speed controller on condensing unit fans. Electrical panel should include main disconnecting switch - nob on door panel, Power Panel & starter for all drives, ------ for Detail Wording of Item Please Refer Tender Booklet and Specfication
Basic price - Ex Factory - Chiller Chiller must be certified with IGBC/USGBC/GRIHA standards.
CHILLER ACESSORIES Chilled Water Pumps Supply, Installation, Testing & Comissioning of centrifugal end suction pumps having cast iron casing, bronze impeller, mechanical seal with electric motor of suitable RPM TEFC squirrel cage induction motor confirming to EFF-1. All pumps shall be factory aligned as required & insulation. The pump motor shall be suitable for 415± 10% volts, 50 cycles/second, 3 phase AC power supply. Pump head to be verified based on final shop drawings. Capacity: 136 m3/hr, 6 kg/cm² , Operating Temp : 6.5 - 12.5 deg C ,Medium : chilled water (1W+1S)
Starter Panel Supply, installation, testing & commissioning of starter panel for Chilled water pump. Capacity: 136 m3/hr, 6 kg/cm² , Operating Temp : 6.5 - 12.5 deg C ,Medium : chilled water (1W+1S)
Supply, Installation, Testing & Commissioning of the following
Pressurised closed expansion tank of M.S construction with interchangeable EPDM/BUTYL bladder working on nitrogen pressure with following accessories Pressure gauge, Safety valve, conforming as per specification and of below capacity. The Pressure rating shall be as per system design pressure.Capacity: 750 Litres.
Pressurisation pumping skid, comprising of two multistage high pressure pumps (1 working +1 standby) with control panel with soft starters, valves, flow meter and other accessories as described in detailed specifications. The pumps shall be able to deliver at least 2 CMH flow at suitable pressure head.It shall be suitable for outdoor installation. The controller shall be suitable for IP 55 and BMS compatible for remote on/off, alarm.Capacity - 2 CMH @25 m
Combined Air and Dirt Separator of M.S construction as per specifications on the return water line located at the pump suction or a suitable location as suggested. The separator should be complete with high capacity air vent, service valve, water inlet, flanges, drain valve etc. of below sizes:-Connection Size - 300 mm
INDOOR UNIT Ceiling Suspended Air Handling Units AHU FOR OT Supply, Installation, Testing &Commissioning of AHU with Double Skin Polyurethane foam (PU) insulation panel with 0.8 mm high strength powder coated steel as external skin and 0.8 mm galvanized steel (GI) as internal skin. The thermal break profile shall be provided with 50mm PU foam insulation thickness with a density of 48 kg/m3, which provides an overall thermal conductivity, k = 0.017 W/(m•K). Unit shall be equipped with marine light & limit switch. Filter shall be EU 4 as pre filter & F8 for Fine filter.Cooling coil face velocity shall not exceed 2.5 m/s or 500 FPM. Coil shall be designed at 7 °C inlet water temperature and outlet water temperature at 12°C.Air-handling unit shall consist of DIDW forward/Backward curve, Energy-efficient AMCA certified fans centrifugal fan mounted on a common solid shaft, which shall be driven by a motor through pulley and belts arrangement. Motor shall be Belt drive package, VFD duty compatible IE-3 TEFC squirrel cage induction motor suitable for operation on 415±10% Volts, 50 Hz, 3 Phase AC power supply.
OT Module Plain Air ceiling constructed out of 1.6mm thick Aluminium sheet, with neoprene gasket to seal the gap between ceiling and plan air. Having HEPA filter. The HEPA filters having dust spot efficiency of 99.99% 0.3 Micron. Air and light diffuser made out of two layer of mono filaments precise woven polyster for the plan air ceiling to give a "LAMINAR AIR FLOW" of filtered air. Laminar Flow Plenum Desiged for Operation theater Size : 72" X 72" X 18" ( H ) and as per actual Approved make: METATECH / ACCUMAX /ASB
Supply, Installation, Testing &Commissioning of AHU with Double Skin Polyurethane foam (PU) insulation panel with 0.8 mm high strength powder coated steel as external skin and 0.8 mm galvanized steel (GI) as internal skin. The thermal break profile shall be provided with 50mm PU foam insulation thickness with a density of 48 kg/m3, which provides an overall thermal conductivity, k = 0.017 W/(m•K). Unit shall be equipped with marine light & limit switch. Filter shall be EU 4 as pre filter & F8 for Fine filter.Cooling coil face velocity shall not exceed 2.5 m/s or 500 FPM. Coil shall be designed at 7 °C inlet water temperature and outlet water temperature at 12°C.Air-handling unit shall consist of DIDW forward/Backward curve, Energy-efficient AMCA certified fans centrifugal fan mounted on a common solid shaft, which shall be driven by a motor through pulley and belts arrangement. Motor shall be Belt drive package, VFD duty compatible IE-3 TEFC squirrel cage induction motor suitable for operation on 415±10% Volts, 50 Hz, 3 Phase AC power supply. AHU Price shall include Valve package Valve package shall include - 1. Butterfly valve - 2 Nos. 2. Y-strainer - 1 Nos. 3. PICV valve - 1 Nos. 4. Pressure gauge - 2 Nos. 5. Temperature gauge - 2 Nos. 6. Air vent - 1 7. Drain valve - 1 Note:- Insulation shall be done on valves same as chilled water piping insulation. AHU Shall be supply as per tender specification & below mentioned capacities.
2000CFM / 4.4 TR / 25 mmwg ESP -
2500CFM /5.7TR / 25 mmwg ESP -
3000CFM / 6.7 TR / 25 mmwg ESP -
3500CFM / 7.7 / 25 mmwg ESP -
Chilled water Fan Coil unit Supply installation testing and commissioning of Chilled water factory fabricated standard FCU with inbuilt drain pump.cost shall be Inclusive of valve package.Valve package shall be provided with On-Off type control valve & Thermostat. Necessary cabling from electrical panel to unit socket will in the scope of Electrical contractor. THIRD FLOOR
Chilled water Hi Wall unit Supply, Installation, Testing & Commissioningof wall mounted type Indoor unit with compact water cooled cooling coil, electronic expansion valve and multispeed fan motor. The blower shall be dynamically balanced and design for silent operation, the filter shall be Plasma & Synthetic washable media type. All Hi-wall Unit shall be controlled with cordless remote control.
Supplying, laying/fixing testing & commisioning of following nominal size of chilled water piping inside the building ( with necessary clamps, vibration isolators and fitting but excluding valve, strainer , guage etc.) duly insulated with following clsed cell elastomatric nitrile rubber of minimum 45kg / cu.m density,thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class O insulation applied by suitable adhesive complete including repairing of damage to building etc.as per specification and as required complete in all respect . Note:- the pipe of size 150mm & and below shall be M.S. 'C' class as per IS : 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS 3589, from minimum 6.35mm thick ms sheet for pipe of 350 mm dia. And from minimum 7mm thick MS Sheet for pipe of 400mm dia and abov.
300 Dia. (32mm thick insulation)
250 Dia. (32mm thick insulation)
200 Dia. (32mm thick insulation)
150 Dia. (32mm thick insulation)
125 Dia.(32mm thick insulation)
100 Dia. (32mm thick insulation)
80 Dia. (32mm thick insulation)
65 Dia. (32mm thick insulation)
50 Dia. (32mm thick insulation)
40 Dia. (32mm thick insulation)
32 Dia. (25mm thick insulation)
25 Dia. (25mm thick insulation)
Supplying and erecting 25mm (ID/OD) Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 32mm (ID/OD) Chlorinated polyvinyl chloridepipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series) withnecessary CPVC fittings and solvent cement for Solar Water Heater System as perspecification No. ESD-HWP/CPVC
Supplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC
Supply installation & erection of supports Required pipe of MS material.
VALVE & FITTINGS Supply, Installation, testing & commissioning of cast iron body Butterfly valves, PN 16 rating with matching flanges.
300 mm dia
150 mm dia
125 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
Supply, installation, testing & commissioning of Brass/Carbon steel body Ball valve, The ball and the shaft shall be of stainless steel. The seat shall be of PTFE. The valve shall be complete with socket weld ends and with PN 16 rating.
32 mm dia
25 mm dia
Supply, installation, testing & commissioning of MS Y Strainers, PN 16 rating with matching flanges.
150 mm dia
Supply & Installation of Single arch expansion joints (Rubber Bellows) designed at PN16. Rubber compund shall meet flame resistance as per ASTM F1123 in accordance with 30 CFR
Supply, Installation, testing & commissioning of flow switch designed at PN16. Contact Point life shall be 1000K cycle. Operating temperature of fluid max 100 degC
Supply, installation, testing & commissioning of 150mm dia dial type pressure gauges with liquid filled and SS syphon & ball valve. Range: (0-16 kg/cm2)
Supply, installation, testing & commissioning of 150 mm dia dial type temperature gauges with liquid filled and Copper thermowell, 0-50 deg C
Supply, installation, testing & commissioning of Auto air vents with ball valve having brass body and Nylon float, PN 16.
25 mm dia
Supply, installation, testing & commissioning of test points with brass body, nitrile sealing bushes with facility to measure temp & pressure in water or non-corrosive fluids with max temp & pressure of 110 C & 20 bar respectively.
Supply, installation, testing & commissioning of NRV Valve connections with control rods & matching flanges, PN 16.
150mm dia
Supply, installation, testing & commissioning of Manual Balancing Valve connections with control rods & matching flanges, PN 16
150 mm dia
SHEET METAL WORKS:Supply , fabrication, erection, balancing and commissioning of factory fabricated Rectangular ducts (Supply air, Fresh air and exhaust, VAV connections ) using GI Sheets (IS 277 class 4). The price shall include TDF flanges, turning vanes, Necessary size Rod hangers with anchor fastner & supports Joints are properly sealed with transparent silicon. The duct to be manufactured as per SMACNA standards for class -500 Pascal's. Duct shall be provided with 120 GSM zinc coating.Joints to be air tight and tested for leaks as per SMACNA with certified leakage tester with printer.
0.8mm Ducting (22G)
0.63mm Ducting (24G)
Flexible Canvas Connector :At all connections between ducts & fans/ Ducted Units/TFA; fire-retardant, lint-free double canvass/rexin connections of heavy gauge shall be provided. One set of canvas connection include required quantity of canvas for one evaporator indoor unit / Exhaust Or Fresh Air Fan. Notes: The ducting support should be as per tender specification and additional supports to be provided as per consultants instructions. Muslin cloth cover for all air outlets during construction. Pressure testing of complete duct work as per DW/ SMACNA standard. Silicon sealant shall be applied for longitudinal & transverse joints as per specification.
THERMAL & ACOUSTIC INSULATION:Acoustic Insulation : Supply & fixing of Acoustic insulation for Supply air duct using 15 mm thick class 1 rating open cell nitrile rubber elastomeric insulation with density of 140-180 kg /m³. The insulation mamafactured as per BS 476 part & which should also meet UL 94 test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209) should not support microbial growth (ASTM 2180, G21,G22) and should not emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.04w/m k @ 20 degC as per DIN EN 12667. and water vapor permeance of 0.10. Adhesive shall be used additionally with VOC level not excedding 50 grms / litre 10 mm thick.
Supply & Installation of Thermal insulation (External) of ducting with Nitrile Rubber 19mm thick closed cell class O insulation with Density of the nitrile rubber shall be 40-60 Kg/m3.Thermal conductivity as per ASTM C 518 of the insulation material shall not exceed 0.03 W/moK at an average temperature of 10O C stuck to clean duct surface with synthetic rubber adhesive. (External Thermal insulation.)Self Adhesive should be a solvent based low voc, polychloroprene rubber contact adhesive, used for strong and flexible, full surface bonding of elastomeric rubber to elastomeric rubber and elastomeric rubber to various galvanized and non-galvanized metal. Insulation Material shall have zero ODP & GWP. Note: Insulation work to be coordinated with other agencies and repair to be included by contractor as per site requirement. Vendors to take care of the installation, if any damages takes place the vendor to repair or replace and hand over to clients in good and acceptable condition.
GRILL Supply, Installation and Balancing of powder coated Extruded aluminium Supply air & Return air grill. Sizes & technical details shall be in accordance with approved shop drawings and specifications.Supply air shall be provide with collar damper.
DIFFUSER Supplying & erecting tile type modular diffuser made from aluminium sheet complete with powder coated matching to the ceiling shade for provided suuply air.
600 x 600 mm Supply & Return - ( Neck Size 375 x 375 )
COWL PIECE WITH BIRD SCREEN
Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for fresh air fan of 450 mm as per specification no FG-FAS/MSC
VOLUME CONTROL DAMPER
Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction complete with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
Supply, Installation, Testing, Commissioning of Aluminium cladding with 22 gauge. (Thickness must be as per technical specifications)
FRESH AIR FAN Supply, Installation, Testing & Commissioning of Inline ducted fan with motor. Enclosed, single phase, 230V, 50/60Hz external rotor type, motors included sealed for life ball bearing assemblies and Class B, IP44 protection with an internal automatic reset safety thermal overload protection device as standard.
1000 CFM, Static Pressure: 15 mm of w.g.
600CFM, Static Pressure: 15 mm of w.g.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying and erecting ABC powder type fire extinguisher as per IS : 15683 of 9 kg capacity with necessary clamp for erection on wall.
Supplying and erecting Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 Kg capacity cartridge type con. to IS: 15683 complete erected with necessary clamp made from 50 mm x 6 mm M.S.flat with nut and bolts grouted in wall complete.
Providing floor mounting stand for keeping 4 Nos. of Fire Buckets 1500 mm in length, 900 mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Providing round bottom Fire bucket of 9 Litres capacity as per IS: 2546 made out of 24 guage G.I. sheet with extra handle at bottom duly painted white inside and red outside with Fire mark , on provided stand/wall hook .
Supplying, installation, testing and commissioning of main fire pump(MFP /EP) suitable for water discharge of 2850 LPM at 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 75kW or of suitable kW for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 LPM at 90 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2850 LPM at 90 m head driven by 110 HP or suitable HP capacity diesel engine at required working speed suitable for automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (2working) with necessary accessories, wiring & cabling along with allied accessories with following ----- For Detailed Wording of Item Please Refer Tender Booklet and Speciifcation
Supplying, erecting & terminating XLPE armoured cable 3 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating XLPE armoured cable 2 core 1.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting PVC armoured cable 12 core 1.5 sq mm Cu conductor with continuous G.I. earth wire complete erected with glands and lugs, on wall or laid in provided trench/ pipe /cable trey as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and installing G.I. pipe above ground of C class ERW of size 200 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 150 mm dia with with necessary fittings as per specification no. FF-PP
Providing coating of Bitumen Paint & 4mm thick Wrapping as per IS 10221 for underground 150 mm Ring Main of Fire Fighting System.
Excavating soft Murum/Soil roadby chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good.
Supplying and installing G.I. pipe above ground of C class ERW of size 100 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 80 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 65 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 50 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 40 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 32 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and installing G.I. pipe above ground of C class ERW of size 25 mm dia with with necessary fittings as per specification no. FF-PP
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 50 mm dia complete as per specification no. FF-VL/NRV
Supplying and installing cast iron double flange Butterfly Valve of size 150 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 100 mm dia as per specification no. FF-VL/BFV
Supplying and installing cast iron double flange Butterfly Valve of size 50 mm dia as per specification no. FF-VL/BFV
Supplying and erecting stainless steel Single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying SS Branch Pipes of 63 mm dia. fitted with 20 mm dia detachable hexagonal multipurpose nozzle as per specification FF-FFA/NEW
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying and erecting M.S./CRCA cabinet for housing Hydrant valve, hose pipe and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying and erecting 25 mm dia GM Air Release Cock with necessary GI coupling to be fitted on top of air vessel or on wet riser as per specification FF-FFA/ARV.
Supplying and installing Air Vessel of 300 mm dia 1.5 mtr in height M.S. tank installed inside pump house as per specification no. FF-FFA/ACT.
Supplying and installing Fire Brigade Header of 150 mm dia, for supplying water in fire tank as per specification no. FF-FFA/FBC
Supplying and installing Fire Brigade Header (Siamese Connection) of 150 mm dia, supplying water to wet riser system as per specification no. FF-FFA/SMC
Supplying and erecting 200 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and erecting 75/80 mm dia Cast Iron end line strainer of T-Pot type flanged end pattern, PN16 pressure rating, screen of SS and end connection with flanged, for positive suction complete as per specification no. FF-VL/ELS
Supplying and installing wall mounted swinging Hose Reel Drum fitted with 19 mm dia 30 mtr long high pressure polypropylene (polyhose) pipe fitted with necessary accessories complete as per specification no. FF-FFA/HRD
Supplying and erecting one no. Brass orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification No. FF-FFA/OP
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Supplying and installing gun metal gate valve of size 25 mm dia as per specification no. FF-VL/GV.
Supplying and erecting 15 mm (½") dia. NBCM Body chrome finished (pendent / Upright type) quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction as per specification No. FF-SPR
Supply, Installation, testing & commissioning of UL listed / FM approved S S Braided flexible drops 25 mm dia capable to with stand maximum working pressure of 175 psi with all fittings for making connection to sprinklers and with the branches 1.2 Mtrs in length
Supplying and erecting cast iron double flange sluice valve 200 mm dia. complete as per specification no. FF-VL/SV
Supplying and installing Cast iron double flange Sluice valve 100 mm dia as per specification
Supplying and installing Cast iron double flange Sluice valve 80 mm dia as per specification
Supply & Installation of Stainless steel finish rossette plate of dia 75 mm for below false ceiling application as per specification
Supply, Installation, testing & commissioning of Installation control (Alarm) valve of cast iron body and brass/ bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box ball valves, MS pipe of reqd. size, flanges, orifice plate, gasket etc. of size 150 mm dia as reqd.
Supply, Installation, testing & commissioning of flow switches in 80/100/150 mm dia pipe with all accessories as required
Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
Supplying and fixing of Signages-Exit (Nightglow with lamination, Self adhesive) 100 mm x 300 mm
Supplying and fixing of Signages-Staircase (Nightglow with lamination, Self adhesive) 100 mm x300mm
Supplying and fixing of Signages-Fire Alarm (Nightglow with lamination, Self adhesive) 200 mmx250 mm
Supplying and fixing of Signages-Fire Extinguisher (Nightglow with lamination, Self adhesive) 200 mm x200mm
Supplying and fixing of Signages-Hose reel (Nightglow with lamination, Self adhesive) 200 mm x250mm
Supplying and fixing of Signages-Assembly Point (ACP with MS, Grouted) 600 mm X600 mm
Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FF-AFAS/SD .
Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area's etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting and testing remote response indicators as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
Supplying, erecting, testing and commissioning amplifier 120 W for Public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply as per specification No. FF-PA/AFR
Supplying, erecting, testing and commissioning sound column 15 to 30 Watts complete as per specification No. FF-PA/ SOC
Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with • Rated capacity :- 20 Passenger/1360Kg • Floors :- Ground + 7th floor (8 Stops/8 Landings) • Travel :- 28 mtrs • Location of Lift Machine:- MR/MRL • Rated speed :- 1.5mps VS • Car/Landing door clear opening of 1200mm wide x 2000mm high • Clear Car size of 1300mm wide x 2400mm deep x 2250mm high • Lift shaft available having clear size of 2930mm wide x 2770mm deep, +/- 1800mm Pit depth, 4000mm Overhead. • Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). • Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. • COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.-------For Dteiled of Wording Refer Tender Booklet
SITC of Electric Traction Passenger cum Stretcher/Hospital Lift with • Rated capacity :- 26 Passenger/1768Kg • Floors :- Ground + 7th floor (8 Stops/8 Landings)• Travel :- 28 mtrs• Location of Lift Machine:- MR/MRL • Rated speed :- 1.5mps VS • Car/Landing door clear opening of 1200mm wide x 2000mm high• Clear Car size of 1400mm wide x 2550mm deep x 2250mm high• Lift shaft available having clear size of 3050mm wide x 2500mm deep, +/- 1800mm Pit depth, 4000mm Overhead. • Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).• Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.• LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. ------For Dteiled of Wording Refer Tender Booklet
2MP IR Indoor Dome Fixed Camera:-1/2.8" Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8mm Fixed lens, 0.01 Lux at F1.2, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, Alarm & Audio : 1 input & output, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, IK10, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face Detection, Audio exception detection, video tampering, UL, CE, FCC certified.Warranty for 01 Year .
2MP IR Bullet Fixed Camera:- 1/2.8" Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S, PROFILE G), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 128 GB (SD card not included), IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Face Detection, Video tampering, UL, CE, FCC certified.Warranty for 01 Year .
128ch Network Video Recorder:- Connect Up to 128 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI & Two VGA outputs, Atleast one HDMI output of 4K resolution, atleast 1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 8TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
Supply Installation Testing & commissioning of 3.5 inch Enterprise Hard Disks of 7200 RPM with a 6 TB Interface, 256Mb Cache,600000 load/ Unload cycles,2500000(MTBF), with 5 Year Manufacturers warranty,and with the following poweer management capacities7.1 Sequential read, 6.7- Sequential write, 6.8 -Random read/write, 5.0- Idle
42" LCD 24X7 Surveillance Monitor High performance High performance LCD monitor. Contrast ratio: 800:1. Picture-In-Picture (PIP) and Picture-And-Picture (PAP). Looping BNC output. RGB, DVI, and HDMI interface. Slim, space-saving design. Removable desk stand. 1366 x 786 TVL resoluiton
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954 mm) as per specification No. WG-NAS/RAK
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of 1/2 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and erecting 5m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying, installing and testing UTP connector (RJ-45) as per specification No.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367mm) as per specification No. WG-NAS/RAK
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying and fixing Power Distribution Unit for networking rack comprises of 6/16A (6 Nos. sockets), 25 A modular MCB, appropriate rating fuse and indicator lamp, enclosed in black powder coated metal with necessary arrangement for fixing as per specification No. WG-NAS/RAK
Pawar Patkar Constructions Pvt.Ltd.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid